Contents

1. 10 for the year 2010 12 2 4 Pump assembly Important During mounting of the pump make sure that the coupling insert in the coupling is arranged between pump tube and motor e Place motor on the transition piece of the pump tube e Turn motor until the coupling is operative e By means of 4 screws fix motor to the pump tube 2 5 Pump installation Danger Liquid pumped under voltage Electric shocks can kill you mmerse the pump into the liquid to be pumped down to the outlet only Connect the pump with the selected screw connections or flanges with the piping system The piping system may not mechanically load the pump e The nominal diameters of the discharge side connection pipe and pump connection should at least be the same Use a foot strainer when pumping liquids containing large mechanical impurities see Fig 1 Fibrous materials which may cause rotating parts to seize up must be kept away from the delivery element of the pump tube If following the disconnection of the pump there is a greater backflow volume or higher pressure potential on the discharge side install a check valve in the discharge line Agitators or turbulent flows in the container endanger the pump stability Pumps having a nominal length of over 1 5 m should be additionally fixed at the pump foot see Fig 2 The fixing must allow the pump to expand lengthwise 2 6 Checking the pipeline Prior to starting up t
2. stoffe die zum Festsetzen drehender Teile neigen m ssen vom F rderelement der Pumpe ferngehalten werden e Liegt nach Abschalten der Pumpe druckseitig ein gr eres R ckstromvolumen oder ein h heres Druckpotential vor dann ontieren Sie ein R ckschlagventil in die Druckleitung hrwerke oder wirbelnde Str mungen im Beh lter gef hr en die Stabilit t der Pumpe Befestigen Sie Pumpen mit ner Nennl nge ber 1 5 Meter zus tzlich am Pumpenfu siehe Bild 2 Die Befestigung muss der Pumpe eine L n genausdehnung erm glichen 3 20 2 6 berpr fung der Rohrleitung Vor der Inbetriebnahme m ssen Sie die Rohrleitungen von Verunreinigungen s ubern auf Dichtigkeit pr fen entsprechend den Sicherheitsvorschriften abdr cken 2 7 Elektrischer Anschluss Gefahr Unter Spannung stehender Netzanschluss Elektrischer Schlag kann Sie t ten Elektrischer Anschluss darf nur von einer geschulten Fachkraft Elektriker durchgef hrt werden Sorgen Sie vor dem Anschluss der Tauchkreiselpumpe Typ B6 daf r dass die Werte f r Spannung Frequenz auf dem Typenschild mit den Betriebsnetzwerten bereinstimmen der Stromanschluss gem dem Nennstrom des Motors abgesichert ist e bei festem Anschluss der Pumpe der Schalter ausgeschaltet ist 2 8 Drehrichtungskontrolle Die Drehrichtung des Motors muss mit dem Drehrichtungspfeil bereinstimmen siehe Bild 3 Andernfalls muss ein Ele
3. 3 8 Lutz Die Fluid Manager Originalbetriebsanleitung 37 TAUCHKREISELPUMPE Operating Instructions 9 13 SUBMERSIBLE CENTRIFUGAL PUMPS Typ Type B6 PP B6 Niro Vor Inbetriebnahme Betriebsanleitung lesen Read this operating instructions before start up F r k nftige Verwendung aufbewahren To be retained for future reference Bild Fig 3 P Bild Fig 2 Bild Fig 1 Bild Fig 5 Bild Fig 4 Inhaltsverzeichnis Allgemeine Sicherheitshinweise 4 4 1 1 Gef hrlichkeit dieser Maschine 4 1 2 Sicherheitshinweise und Tipps 1 3 Bestimmungsgem e Verwendung EM 155 Geralnremque lentes end 6 en 6 2 1 Transport Lagarde 6 O 6 DO sen 6 2 4 Zusammenbau der Pumpe ccccecccesesessssscssssscssssssessssssscsescessssssssscasasacsceeseerers 6 2 5 Installation 6 2 6 berpr fung der Rohrleitung 7 2 7 ElekbrischerAmSchluss o oi 7 2 8 A AN NO 7 earr 7 A 7 AO A 7 4 1 Reinigen 4 2 Austri 5 ROPAraturen ccccscscscssssscssssssssssssssssssesessesessssssssssseaesseceseesesssssaeacasesessesesesssaeacaseeesenees 7 EG Konformit tserkl rung une 15 Allgemeine Sicherheitshinweise Die Betriebsanleitung ist vor Inbetriebnahme vom Be diener der Pumpe zu l
4. 6 45 B6 60 PP PP PP PP Niro Niro Niro Niro Viskosit t Nna 4000 3000 2000 1000 4000 3000 2000 1000 Mediumstemperatur Trax 50 50 50 50 100 100 100 100 7 ermittelt mit l Eigenm chtige Umbauten und Ver nderungen der Pumpe sind aus Sicherheitsgr nden verboten Ar Gefahr SS Brand und Explosionsgefahr durch F rderfl ssigkeit Verbrennungsgefahr Druckwelle wegfliegende Teile k nnen Sie t ten F rdern Sie keine brennbaren oder explosiven Fl ssigkeiten Setzen Sie die Pumpe nicht in explosionsgef hrdeter Umgebung ein 1 4 Emissionen Der A bewertete quivalente Dauerschalldruckpegel der Tauch kreiselpumpe Typ liegt unter 70 dB A 1 5 Gefahrenquellen Die Tauchkreiselpumpe Typ arbeitet mit einem rotierenden F rderrad Hineingreifen in die Saug ffnung der Pumpe w hrend des Betriebs kann Finger und Handbr che verursachen Undichtigkeiten im Leitungssystem k nnen je nach gef rderter Fl ssigkeit zu Ver tzungen Vergiftungen usw f hren Die Pumpe kann nach Spannungsausfall Netzunterbrechung defekte Sicherung unkontrolliert anlaufen wenn Sie einge schaltet bleibt Vor Wartungs und Reinigungsarbeiten Motor ausschalten und Spannungsversorgung unterbrechen Netzstecker ziehen Si cherung ausschalten 2 Inbetriebnahme 2 1 Transport Lagerung Die Tauchkreiselpumpe Typ B6 wird in einer Transportkiste verpackt angeliefert F r die Lagerung der verpackten Tauchkreiselpumpe Typ
5. B6 gibt es keine besonderen Anforderungen 2 2 Auspacken Den mit Oben gekennzeichneten Deckel der Transportkiste ffnen Die Halteschieber aus der Kiste ziehen Pumpwerk und Motor entnehmen Die Verpackung kann ebenfalls bestellte Zubeh rteile enthalten Pr fen Sie deshalb die Lieferung mit Hilfe der Bestellung auf Vollst ndigkeit 2 3 Baujahr Das Baujahr des Ger tes ist aus dem Feld f r die Seriennummer ersichtlich Dort sind mit einem Bindestrich die letzten beiden Stellen des Baujahrs an die Seriennummer angeh ngt z B 10 f r das Jahr 2010 2 4 Zusammenbau der Pumpe Wichtig Beachten Sie bei der Montage der Pumpe dass der Kupplungseinsatz in der Kupplung zwischen Pumpwerk und Motor liegt e Motor auf Zwischenst ck des Pumpwerks setzen e Motor drehen bis die Kupplung greift e Motor mit 4 Schrauben an Pumpwerk befestigen 2 5 Installation der Pumpe Gefahr Unter Spannung stehende F rderfl ssigkeit Elektrischer Schlag kann Sie t ten Die Pumpe nur bis zum Auslaufstutzen in die F rder fl ssigkeit tauchen Schlie en Sie die Pumpe mit den gew hlten Verschrau bungen oder Flanschen an das Leitungssystem an Die Rohrleitung darf die Pumpe nicht mechanisch belasten e Die Nennweite von druckseitigem Anschlussrohr und Pum penanschluss soll gleich gro sein e Bei Fl ssigkeiten mit groben mechanischen Verunreinigungen m ssen Sie ein Fu sieb verwenden siehe Bild 1 Faser
6. esen und die Hinweise sind w h rend des Betriebs einzuhalten 1 Die bestimmungsgerechte Gebrauchslage des Pump werks ist senkrecht 2 Der Bediener hat beim F rdern gef hrlicher Fl ssigkeiten z B tzend hei giftig usw passende Schutzkleidung zu tragen Gesichtsmaske oder Schutzbrille Sch rze und Handschuhe 3 Beachten Sie dass alle Anschl sse und Verbindungen richtig befestigt sind 4 Beachten Sie die Grenzwerte f r Temperatur Viskosit t und Dichte der F rderfl ssigkeit 5 Nicht in die Ansaug ffnung der Pumpe fassen 6 Die Pumpe darf nicht trockenlaufen 7 Beachten Sie dass die Pumpe nach Spannungsausfall unkontrolliert wieder anlaufen kann 8 Pumpe darf nicht in explosionsgef hrdeter Umgebung verwendet werden 9 Es d rfen keine brennbaren Fl ssigkeiten gef rdert wer den Instandsetzung nur durch den Hersteller oder autorisierte Vertragswerkst tten 1 o Die Unfallverh tungsvorschriften des jeweiligen Landes sind unbedingt einzuhalten 1 Sicherheit 1 1 Gef hrlichkeit dieser Maschine Die Tauchkreiselpumpe Typ B6 wurde vor der Auslieferung einer Funktionspr fung unterzogen Bei Fehlbedienung oder Missbrauch drohen Gefahren f r Leib und Leben des Bedieners die Pumpe und andere Sachwerte des Betreibers die effiziente Arbeit der Maschine Alle Personen die mit der Aufstellung Inbetriebnahme Be dienung Wartung und Instandhaltung der Maschine zu tun
7. haben m ssen e entsprechend qualifiziert sein diese Betriebsanleitung genau beachten Es geht um Ihre Sicherheit 1 2 Sicherheitshinweise und Tipps In dieser Betriebsanleitung werden folgende Symbole ver wendet Gefahr Bezeichnet eine unmittelbar drohende Gefahr Bei Nichtbeachten des Hinweises drohen Tod oder schwerste Verletzungen i Wichtig Bezeichnet Anwendungstipps und andere n tzliche Informationen 1 3 Bestimmungsgem e Verwendung sigkeit geeignet ist Die Tauchkreiselpumpe Typ eignet sich ausschlie lich zum F rdern von reinen getr bten nicht brennbaren aggressiven und nicht aggressiven Medien wobei jedoch die benetzten Pumpenmaterialien gegen ber dem F rdermedium best ndig sein m ssen Pr fen Sie anhand einer Best ndigkeitstabelle und der nachfolgenden Werkstoffauflistung ob das Pumpwerk f r die F rderfl s Pumpwerk B6 15 B6 30 B6 45 B6 60 B6 15 B6 30 B6 45 B6 60 Benetzte PP PP PP PP Niro Niro Niro Niro Werkstoffe PP Niro 1 4571 Hastelloy Viton Oxidkeramik e s Viton ist ein eingetragenes Warenzeichen von DuPont Performance Elastomers Die Viskosit t und die Temperatur der F rderfl ssigkeit m ssen unter den nachfolgend genannten Werten liegen Pumpwerk B6 15 B6 30 B6 45 B6 60 B6 15 B6 30 B
8. he pipelines must be cleaned from impurities be checked for tightness be pressure tested according to the safety regulations 2 7 Electrical connection Danger Live mains connection Electric shocks can kill you The electrical connections may only be carried out by qualified personnel a trained electrician Make sure before connecting the submersible centrifugal pump type B6 that The values for voltage and frequency given on the nameplate agree with the data for the mains the power connection is fuse protected according to the nominal current of the motor in case of fixed pump connection the switch is off 2 8 Checking the direction of rotation The motor must rotate in the direction indicated by the arrow see Fig 3 Otherwise an electrician has to reverse the motor connections 3 Operation 3 1 Dry running The pump is said to run dry if it continues to operate without pumping any liquid whatsoever The submersible centrifugal pump type B6 is not allowed to run dry Dry running must be prevented by supervision or technical means such as level or flow monitoring devices 4 Maintenance Servicing Protect the environment Make sure that polluting liquids do not get into the environment sewage system ground etc For more detailed information pleae contact the responsible administrative authority 4 1 Cleaning Flush and clean the pump after pumping aggressive tacky crystall
9. im Tel 0 93 42 8 79 0 Fax 0 93 42 87 94 04 e mail info lutz pumpen de http www lutz pumpen de Technische nderungen vorbehalten 07 10 Subject to technical changes Best Nr 0698 190 Printed in Germany Dru
10. izing or contaminated liquids The constant readiness for operation of the pump is thus assured 4 2 Leakage of liquid Provided above the outlet is a port through which liquid can leak in case of defective seals see Fig 5 If a leakage is detected at this point the pump must by all means be turned in for repair 5 Repairs Repairs should only be made by the manufacturer or authorized Lutz dealers Only use original Lutz spare parts Before sending back the appliance following must be observed e Residuals in the appliance can cause danger to the environment and human health The appliance must be completely emptied rinsed and cleaned Please advise which liquid has been pumped A respective safety data sheet must be attached to the return consignment Lutz Pumpen GmbH Erlenstra e 5 7 D 97877 Wertheim Die Fluid Manager EG Konformit tserkl rung im Sinne der EG Maschinenrichtlinie 2006 42 EG Anhang Il A Hiermit erkl ren wir dass die nachfolgend bezeichnete Maschine aufgrund ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Si cherheits und Gesundheitsanforderungen den aufgef hrten EG Richtlinien entspricht Bei einer nicht mit uns abgestimmten nderung der Maschine verliert diese Erkl rung ihre G ltigkeit Ger teart Tauchkreiselpumpe Typ B6 EG Richtlinien EG Maschinenrichtlinie 2006 42 EG EG Niederspannungsricht
11. ktriker den Motor umklemmen 3 Bedienung 3 1 Trockenlauf Man spricht von Trockenlauf wenn die Pumpe absolut keine Fl ssigkeit f rdert Die Tauchkreiselpumpe ist nicht f r Trockenlauf geeignet Sie m ssen Trockenlauf durch Beauf sichtigung oder technische Hilfsmittel wie z B Niveau oder Str mungsw chter verhindern 4 Wartung Instandhaltung Sch tzen Sie die Umwelt Sorgen Sie daf r dass keine belastenden Fl ssigkeiten in die Umwelt Kanalisation Erdreich usw gelangen Genauere Informationen gibt die zust ndige Verwaltungsbeh rde Was serwirtschafts oder Gewerbeaufsichtsamt 4 1 Reinigen Sp len und reinigen Sie die Pumpe nach dem F rdern ag gressiver klebender auskristallisierender oder verschmutzter Fl ssigkeiten siehe Bild 4 Dadurch stellen Sie die st ndige Einsatzbereitschaft der Pumpe sicher 4 2 Austritt von Leckfl ssigkeit Oberhalb des Auslaufstutzens befindet sich eine ffnung durch die bei defekten Dichtungen Leckfl ssigkeit austritt siehe Bild 5 Wenn Sie hier Leckage feststellen muss die Pumpe umgehend zur Instandsetzung 5 Reparaturen Sie d rfen Reparaturen nur vom Hersteller oder autorisierten Vertragswerkst tten ausf hren lassen Es d rfen nur Original Ersatzteile von Lutz Pumpen verwendet werden Vor der R cksendung des Ger tes m ssen Sie folgendes be achten R ckst nde im Ger t k nnen die Umwelt und die mensch liche Gesundheit gef h
12. linie 2006 95 EG EG Richtlinie ber Elektromagnetische Vertr glichkeit 2004 108 EG Angewandte harmonisierte Normen insbesondere EN ISO 12100 1 EN ISO 12100 2 EN 809 EN 55014 Dokumentationsbevollm chtigter Herr Volker Fertig Lutz Pumpen GmbH Erlenstra e 5 7 D 97877 Wertheim J rgen Lutz Gesch ftsf hrer Wertheim 29 07 2010 Lutz Pumpen GmbH Erlenstra e 5 7 D 97877 Wertheim Declaration of Conformity in accordance with EC Directive on machinery safety 2006 42 EC Annex II A We herewith declare that the design and construction of the following machine in the versions mar keted by us fully comply with the relevant basic safety and health requirements specified by the EC Directives listed This declaration ceases to be valid if the machine is modified in any way without prior consultation with us Type of device Submersible Centrifugal Pump Type B6 EC Directives EC Directive on machinery safety 2006 42 EC EC Directive of low voltage equipment 2006 95 EC EC Directive on electromagnetic compatibility 2004 108 EC Applicable harmonized standards in particular EN ISO 12100 1 EN ISO 12100 2 EN 809 EN 55014 Person authorised to compile the technical file Mr Volker Fertig Lutz Pumpen GmbH Erlenstra e 5 7 D 97877 Wertheim Wertheim 29 07 2010 J rgen Lutz Managing Director 15 Lutz Die Fluid Manager Lutz Pumpen GmbH Erlenstra e 5 7 D 97877 Werthe
13. nts for application and other useful information 1 3 Proper use The submersible centrifugal pump type B6 is exclusively designed for handling pure turbid non flammable aggressive and non aggressive liquids however the wetted pump materials must be resistant to The compatibility of the pump tube for the medium he liquid being pumped n question must be checked with the aid of a resistance table and the table of materials Pump tube B6 15 B6 30 B6 45 B6 60 B6 15 B6 30 B6 45 B6 60 PP PP PP PP 55 55 55 55 Wetted material PP Stainless steel 1 4571 Hastelloy Viton o Oxide ceramics Viton is registered Trademark of DuPont Performance Elastomers Viscosity and temperature of the liquid being pumped must be below the following values listed Pump tube B6 15 B6 30 B6 45 B6 60 B6 15 B6 30 B6 45 B6 60 PP PP PP PP 55 55 55 55 Viscosity Npa MPas 4000 3000 2000 1000 4000 3000 2000 1000 of the medium To 50 50 50 50 100 100 100 100 7 determined with oil Danger Fire and explosion hazard due to delivered liquid Combustion hazard Blast wave Flying parts can kill you Do not pump flammable or explosive liquids Do not operate the pump in explosion hazard area For safety reasons the pump must n
14. ot be converted or modified in any way without authorization 1 4 Emissions The A valued equivalent continuous sound pressure level ofthe submersible centrifugal pump type is below 70 dB A 1 5 Sources of danger The submersible centrifugal pump type B6 operates with a rotating impeller Reaching into the suction port of the pump during operation may cause fractures of fingers and hands Depending on the liquid being pumped leakage in the piping system may cause cauterizations poisoning etc Note that the pump may uncontrolled restart after voltage breakdown power failure defective fuse after remaining switched on Prior to maintenance and cleaning works switch motor off and interrupt voltage supply withdraw mains plug cut out fuse 2 Starting up 2 1 Transport Storage The submersible centrifugal pump type B6 is delivered packed in a case There are no special requirements for the storage ofthe packed submersible centrifugal pump type B6 2 2 Unpacking e Open the cover of the case marked e Pull the holding slides out of the case e Remove pump tube and motor The packaging may also contain any accessories ordered It is therefore important to check that the consignment is complete as ordered 2 3 Year of construction The year of construction of the appliance can be seen on the field for the serial number Here are attached to the serial number the both last digits of the year of construction e g
15. rden Entleeren Sie das Ger t voll st ndig sp len und reinigen Sie es danach e Teilen Sie uns mit welche Fl ssigkeit gef rdert wurde F gen Sie der Lieferung ein entsprechendes Sicherheitsdatenblatt bei Table of Contents General safety 1 1 1 Danger associated with this machine 1 2 Safety information and 1 1 3 Proper use 1 1 5 Sources 1 2 Starting 2 1 TO nai 2 2 1 2 3 Year Of 1 2 4 PUMP ASSOMDIY 2 5 Pump installation 1 2 6 CNecking Me PIDOIMO cmrcomaaan asno mia 1 2 7 vaa 1 2 8 Checking the direction of rotation AB ODEN AMON Frese T 1 4 1 Cleaning 4 2 Leakage of liquid 5 Repairs Declaration Of Conformity 1 General safety information The operator must read the operating instructions before starting the pump and follow these instructions during operation 1 The pump tube may only be operated in an upright osition 2 The operator must wear suitable protective clothing face mask or goggles apron and gloves when transferring azardous liquids e g caustic hot poisono
16. us etc h 3 Ensure that all connections and fittings are properly tightened 4 Note the limit values for temperature viscosity and ensity of the liquid being pumped 5 Do not reach into the intake port of the pump he pump must not be allowed to run dry 7 Note that the pump may uncontrolled restart after voltage eakdown he pump is not allowed to be operated in explosion azard areas bi T h 9 The motor must not be used to pump flammable liquids d 10 The pump may only be repaired by the manufacturer uly authorized repair shop The national accident prevention regulations must be observed without fail 10 1 Safety 1 1 Danger associated with this machine The submersible centrifugal pump type is tested prior to delivery In case of maloperation or improper use there is danger for life and health of the user the pump and other material assets of the user the efficiency of the machine All persons who are dealing with the installation assembly starting operation servicing and maintenance of the machine have to be accordingly qualified e to exactly follow these operating instructions It is your safety 1 2 Safety information and tips In these operating instructions the following symbols are used Danger Refers to a direct danger Non observance of the precaution will cause death or extremely serious injury Important Defines hi