1. TRAL HK 7 Maintenance The following maintenance measures are recommended to ensure optimum performance of the modules e Under most weather conditions normal rainfall is sufficient to keep the glass surface of modules clean Clean the glass surface of the module as necessary Always use clean water and a soft sponge or cloth for cleaning If snow accumulates on top of the modules remove the excess snow gently from the surface of the modules using a brush or broom Check the electrical and mechanical connections periodically to make sure that all connections are tight secure intact and free of corrosion e Do not try to change the components of module Junction box bypass diode and connector e f any problem arises consult a professional for suggestions 8 Disclaimer of liability Because the use of this manual and the conditions or methods of installation operation use and maintenance of the product are beyond Amerisolar s control Amerisolar does not accept responsibility and expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Amerisolar for any infringement of patents or other rights of third parties which may result from use of the product No license is granted by implication or otherwise under any patent or patent rights The information included in this manual is based on Amerisol
2. afe handling of Amerisolar photovoltaic modules Installers should read this manual carefully and follow the instructions strictly prior to installing the modules Failure to follow these instructions may result in death bodily injury or damage to property The installation of modules requires specialized skills and should only be performed by qualified licensed professionals If you have any questions about installation please contact us for further information 2 Safety precautions e Amerisolar modules have passed all required safety tests according to the IEC 61730 and are rated with Application Class A and within this application class modules are considered to meet the requirements for Safety Class II e All installations must be performed in compliance with all local and national applicable standards codes and regulations e Installers should assume all risks of injury that might occur during installation including but not limited to the risk of electric shock e Do not use mirrors or other magnifiers to artificially concentrate sunlight on the modules e Do not attempt to disassemble the modules or remove any components from the modules e Do not install the module in the rain snow or in windy conditions e Use electrical insulated tools and appropriate protective equipment to reduce risk of electric shock e Cover the module with an opaque material during installation to keep electricity from being generated e Do not disco
3. ar s knowledge and experience and is believed to be reliable but such information including product specification without limitations and suggestions do not constitute a warranty expresses or implied Amerisolar reserves the right to change the manual
4. ed on long frames with screw mounting method b Clamp mounting e The modules can be installed in both landscape clamping on the short frame and portrait clamping on the long frame modes by clamp mounting e The module clamps should not come into contact with the front glass and must not deform the frame e Be sure to avoid shadowing effects from the module clamps e The module frame is not to be modified under any circumstances e When choosing this type of clamp mounting method please be sure to use at least four clamps on each module two clamps should be attached on each frame of the module Depending on the local wind and snow loads if the pressure load exceeds 2400Pa additional clamps or support would be required to ensure the module can bear the load For clamping mounting on the long or short frame of the module please refer to Fig 3 and Fig 4 200mm Clamping area gt 1 4 length Fig 3 The module installed on long frames with clamp mounting method Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 C1 NAN FUNG TOWER wae 173 DES VOEUX RD CENTRAL HK I Clamping area V Width 1 4 width 100mm 1 Fig 4 The module installed on short frames with clamp mounting method 6 Electrical installation 6 1 Module wiring Modules are supplied with cables and connectors to be used for s
5. les are attached to a permanent structure the modules should be tilted for optimum winter performance As a rule if the system power production is adequate in winter it will be satisfactory during the rest of the year Optimal tilting of the module is roughly the same as the latitude of installation location 5 4 Installation methods The modules can be installed on the frame using screw mounting and clamp mounting methods as shown in Fig 1 VAL T p J To a Screw mounting b Clamp mounting Fig 1 The module installed with a screw mounting b clamp mounting a Screw mounting The frame of each module has eight mounting holes used to secure the modules to the support structure If the wind or snow loads is less than 2400Pa you can use the four symmetry holes close to the inner side on module frame as shown in Fig 2 If the wind or snow load exceeds 2400Pa you must use all the eight mounting holes The module frame must be attached to a mounting rail using M8 corrosion proof screws together with spring washers and flat washers in eight symmetrical locations on the module Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 CI NAN FUNG TOWER wae 173 DES VOEUX RD CENTRAL HK Mounting hole p 1 i Fig 2 The module install
6. nnect under load 3 Storage and unpacking e Store modules in a dry and ventilated room e Unpack module pallets with care and follow the unpacking steps Be careful when unpacking transporting and storing the modules e Do not lift the module by grasping the module s junction box or electrical leads e Do not place modules on top of each other e Do not stand or step on the module Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 C1 NAN FUNG TOWER wae 173 DES VOEUX RD CENTRAL HK Do not drop the module or allow objects to fall on the module Do not leave the module unsupported or unsecured Keep all electrical contacts clean and dry 4 Product identification Each Amerisolar module has two identical barcodes with 15 digits for its unique identification one is in the laminate and the second is on the backsheet A nameplate is affixed on the backside of the module This nameplate describes main characteristics of the module which include the product type maximum power open circuit voltage short circuit current maximum power voltage maximum power current all as measured under standard test conditions maximum system voltage weight dimensions etc Do not remove any labels from the module If the label was moved out the module will void the warranty 5 Mechanical installation 5 1 Climate condition Amerisolar modules should be installed in the following conditions e Ambient tempera
7. orldwide Energy and Manufacturing USA Co LIMITED Add RM 1708 CI NAN FUNG TOWER 173 DES VOEUX RD CENTRAL HK Installation Manual Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 CI NAN FUNG TOWER wae 173 DES VOEUX RD CENTRAL HK Content 1 General Informatlbi uLissaraaqsvaesvaraudrme Gees areeeentoen 1 2 Safety precaUlons uv44 444400mmtm uante pnisnebnte 1 3 Storage and unpacking 2 versesmnensmmmnemsmemnjeanaeidaendedadddkne 1 4 Product identification scsi oie caste dasedsheelaces ote cereeeussacedtedse est etanbetas kanne 2 5 Mechanical installation rorannnononnnnnonnerrrrnnnnnnnrnnnnnnnnnnrrnrnnnnnnnnnnnennenn 2 5 1 Climate condition 2 vrede areas 2 5 2 Site selection sakke 2 5 3 Module tilt angle 0 eee cece cece ee ee eee eeteee ee eeee ee eeaeaaaaanneeeeeeees 3 5 4 Installation methods 0 0ccceceee cece cece ee eeeeeeeeeeeeeeeeeeaeaaaaeeeeeeeeees 3 6 Electrical installation s siscscccencssdeescresinnncetctsetnenscxanasannsmennneitaiemnsanemmnte 5 6 1 Module wiring sssrnnrnnnnvnonnnrrnrnnnnnnornnnnonnnnnrrnnnnnnsnnnnnenennennnrnnnnnnenene 5 6 2 Gro di g RE EE 5 GMT eN 6 8 Disclaimer of liability veranda ee 6 Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 C1 NAN FUNG TOWER wae 173 DES VOEUX RD CENTRAL HK 1 General information This manual contains information regarding the installation and s
8. ture 20 C to 40 C e Operating temperature 40 C to 85 C e Storage temperature 40 C to 40 C e Humidity below 85RH e Wind load below 2400Pa e Snow load below 5400Pa 5 2 Site selection Amerisolar modules should be installed in a location where they will receive maximum sunlight throughout the year In the northern hemisphere the module should typically face south and in the southern hemisphere the modules should typically face north When choosing a site avoid trees buildings or obstructions which could cast shadows on the modules especially during the winter months when the arc of the sun is lowest over the horizon Shading causes loss of output even though bypass diodes have been fitted in the junction box of the module to minimize any such loss Do not install the module near naked flame or flammable materials Do not install the module in a location where it would be immersed in water or continually 2 Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 C1 NAN FUNG TOWER wae 173 DES VOEUX RD CENTRAL HK exposed to water from a sprinkler or fountain etc 5 3 Module tilt angle Modules connected in series should be installed at same orientation and angle Different orientation or angle may cause loss of output power due to difference of amount of sunlight exposed to the module Modules produce the most power when they are pointed directly at the sun For installations where the modu
9. ystem electrical connections It is not recommended to use modules with different configurations and electrical characteristics in the same system Modules can be connected in series to obtain a high operating voltage The system voltage is equal to the sum of the voltage of each module Modules can also be connected in parallel to obtain a high operating currents The system current is equal to the sum of the current of each string of modules The maximum number of series connected modules depends on system design the type of inverter used and environmental conditions It should be noted that modules must not be connected together to create a voltage higher than the permitted system voltage There is no limitation on the number of modules that can be connected in parallel the number of modules is determined by system design parameters such as current or power output 6 2 Grouding Grouding modules is necessary to reduce or eliminate shock and fire hazards All module frames and mounting racks must be properly grounded in accordance with local and national electrical codes Proper grounding is achieved by connecting the module frames and mounting racks continuously using a suitable grounding conductor The grounding conductor or strap may be copper copper alloy or other material acceptable for use as an electrical conductor Worldwide Energy and Manufacturing USA Co LIMITED Sen Add RM 1708 C1 NAN FUNG TOWER wae 173 DES VOEUX RD CEN