Home
Shine series Solar controller User Manual-En Ver
Contents
1. the wire length between battery and controller is as short as possible E Recommended minimum wire size Shine06 1 5 mm Shine10 2 5mmz2 E Be aware that the positive terminal of Shine are connected together and therefore have the same electrical potential If any grounding is reguired always do this on the positive wires E Connecting capacitive load may trigger short circuit protection P battery negative on the chassis loads connected to the controller must not have an electric connection to the car body otherwise the Low Voltage disconnect and electronic fuse functions of the controller are short circuited Remark If the device is used in a vehicle which has the Page 1 of 3 pages Solar Charge Controller Shine06 10 User Manual 5 Starting up the controller 5 1Self Test As soon as the controller is supplied with battery it starts a self test routine Then the display changes to normal operation 5 2System Voltage The controller adjusts itself automatically to 12V or 24V system voltage As soon as the battery voltage at the time of start up is within 10V to 16V the controller implies a 12V system elseif the battery voltage is within 20V to 30V the controller implies a 24V system If the battery voltage is not within the normal operating rang ca 10 to 16V or ca 20 to 30V at start up a stat
2. Lumiax Shine series Solar charge controller 6A 10A User Manual Lumiax Oingdao www Lumiax com ISO9001 2008 CE RoHS Solar Charge Controller Shine06 10 User Manual Solar charge controller Dear Clients Thanks for selecting the Shine series solar controller Please take the time to read this user manual this will help you to make full use of many advantages the controller can provide your solar system This manual gives important recommendations for installing and using and so on Read it carefully in your own interest please 1 Description of Function Shine series solar controller is specifically designed to meet the needs of solar home systems It provides the best cost effective It comes with a number of outstanding features such as Low cost and high reliability design 12V 24V automatic recognition e Clear readable display of charge discharge and error description Temperature compensation e Four stage charge way fast boost equalization float Full automatic electronic protect function 2 Safety instructions and waiver of liabilit 2 1 Safety The solar charge controller may only be used in PV systems in accordance with this user manual and the specifications of other modules manufacturers No energy source other than a solar generator may be connected to the solar charge controller Batteries store a large amount of energy never short circuit a battery under all circumstances We stron
3. connect at 11 0V 22 0V A Note 1 If the controller goes into low voltage protection it will restore only when the battery being recharged and the voltage reaching the reconnect voltage 2 Around obligue line value separately on behalf of 12V and 24V system s value 9 Technical Data UAN Y System voltage 12V 24V automatic recognition Max solar current or load current Fast voltage 14 0V 28 0V 25 C Boost voltage 14 5V 29 0V 25 C Egualization voltage 14 8V 29 6V 25 C Liquid Float voltage 13 7V 27 4V 25 C Load disconnect voltage 11 0V 22 0V Load reconnect voltage 12 5V 25 0V Battery type Liquid Gel Temperature compensation 4 17mV K per cell boost equalization 3 33mV K per cell float Max solar voltage 55V Max battery voltage 40V Over voltage protection 15 5V 31 0V Dimensions Weight 150x72x35mm 130g Wire size 06A 1 5 mm 10A 2 5mm Own consumption 4mA Ambient temperature 40 C 460 C Degree of protection IP22 Subject to change without notice Version DC27 Page 3 of 3 pages
4. gly recommend connecting a fuse directly to the battery to protect any short circuit at the battery wiring Batteries can produce flammable gases Avoid making sparks using fire or any naked flame Make sure that the battery room is ventilated Avoid touching or short circuiting wires or terminals Be aware that the voltages on special terminals or wires can be as much as twice the battery voltage Use isolated tools stand on dry ground and keep your hands dry Keep children away from batteries and the charge controller 2 2 Liability Exclusion The manufacturer shall not be liable for damages especially on the battery caused by use other than as intended or as mentioned in this manual or if the recommendations of the battery manufacturer are neglected The manufacturer shall not be liable if there has been service or repair carried out by any unauthorized person unusual use wrong installation or bad system design 3 Dimensions 150 3 5 10 o CE Oss nl 8 5 9 l 0 es 535 58 ry 10 3 5 a T T IL T fail 35 mja mjn o a 4 Installation The following diagrams provide an overview of the connections and the proper order ol Ore ile OE Lumiax nei oer wA O 0 66 28 leo 0 E To avoid any voltage on the wires first connect the wire to the controller then to the battery panel or load E Make sure
5. protected by fuse or battery will be permanently damaged 4 The solar panel voltage should not exceed this limit for a long time as voltage protection is done by a varistor Warning The combination of different error conditions may cause damage to the controller Always remove the error before you continue connecting the controller 7 2 Error description Red Load will reconnect els NS Battery is low as soon as battery Red LED is recharged B Switch off all loads Red LED short circuit Remove short is flashing of loads circuit Battery has Change battery Red LED low capacity empty after Battery is Re as Green not being INFO Solar array faulty Remove faulty charged connection aang reverse polarity Check if other sources overcharge the battery If not controller It age is damaged protection and Green Bat Battery wires or LED are battery fuse Check battery lighted damaged battery WTes fuse and has high resistance battery The battery voltage is not within the normal Does not recognize the system voltage Charge or discharge the battery to make the voltage within the normal range All LED Lighted operating rang at start up Page 2 of 3 pages Solar Charge Controller Shine06 10 User Manual 8 Low Voltage Disconnect Function The controller uses state of charge to protect the battery form being deeply discharged Shine series controller is dis
6. us display according to the section 7 2 Error description occur 5 3Battery Type The Shine series controller applies to Liguid and Gel battery the factory default setting is suitable for liguid battery 6 Display Functions The controller is eguipped with 5 LEDS In normal operation the controller shows charge or discharge status battery capacity and load status s 6 1 Battery Capacity display Yellow Red CE7 Green Y BATTERY Red On Energy of Battery lt 25 Yellow On Energy of Battery 25 75 Green On Energy of Battery gt 75 The percentage corresponds to the available energy until low voltage disconnect in relation to a fully charged battery 6 2 Charge amp Error display INFO INFO Green On is charging else is discharge INFO Red On is Error Status according to the section 7 2 Error description 7 Safety Features and Error description 7 1 Safety features Solar terminal Battery terminal Load terminal Protected 1 Protected 1 Protected 2 Switches off Protected 3 immediately Protected Switches off with delay Reverse Current Protected Max 55V 4 Max 40V Switches off switches off the load if the temperature reaches the set value 1 Controller can not protect itself in a 24V system when polarity of battery or solar is reversed 2 Controller can protect itself but loads might be damaged 3 Battery must be
Download Pdf Manuals
Related Search
Related Contents
AUSSCHNITT Portal User Guide Archive Module September 2009 Operating and Service Manual Copyright © All rights reserved.
Failed to retrieve file