1. the keypad works in monostable mode the outputs activation time is 5s input 1 is associated to output 1 input 2 is associated to output 2 inputs are Normally Closed POWER LED stays lit JUMPERS SIGNIFICANCE JP1 Opened collector Closed The transistor outputs are at 12 V This case the current delivered on each output cannot exceed 200 250mA The transistor outputs are open JP2 Used to set the outputs either as relay outputs or as open collecor JP2 consists of 4 Jumpers of 2 pins each numbered on the board as 4 3 2 1 JP2 x x 1 2 3 4 Opened x output open collector Closed x output relay JP3 Used for set up to default See set up to default procedure 9 CONNECTORS SIGNIFICANCE nca a ca 8 peteua stast Noa Jie N j c3 Qe EARR J3 4 c3 Pie No3 Ais 2 RELEU2 nc2 iya c2 2e noz V s nc Zie c 2 e no1 Ale 14 V e 3 Ve spl JP2 12 e 1 Ae 4321 RELEU1 elelelelelelelejele NQININININININISINIS NI N2 GND12V Z Z1 22 22 TAMPER Pin NO4 relay 4 Pin C4 relay 4 Pin NC4 relay 4 Pin NO3 relay 3 Pin C3 relay 3 Pin NC3 relay 3 Pin NO2 relay 2 4 Pin C2 relay 2 Pin NC2 relay 2 Pin NO1 relay 1 Pin Ci relay 1 Pin NC1 relay 1 Pin T4 transistor 4 output Pin T3 tr
2. as open collector outputs They may work either in monostable mode or in bistable mode The activation time for each output is programmable The timing may be up to 1 99 s in monostable mode The value 0 means the output is in bistable mode 1 3 COMMAND INPUTS This are two NO NC programmable command inputs For both the activation time and the associated outpus may be programmed 1 4 PROGRAMMING While in programming mode one may set 1 master code 60 user codes codes corresponding outputs outputs activation times operating mode monostable bistable command inputs 2 DEFAULT PARAMETERS Master code 000000 Outputs activation time 5s Input 1 is associated to output 1 Input 2 is associated to output 4 Inputs are set as NC 3 LED S SIGNIFICANCE LED PosiTIoN SIGNIFICANCE red LED s left outputs state green LED right keypad powered ON red LED right alarm state yellow LED right programming mode The yellow LED witnesses the programming mode 4 AUDIBLE SIGNALS SIGNIFICANCE SIGNAL SIGNIFICANCE 1 short signal key pressed 3 short signals valid code 2 short signals enter into programming mode 1 long signal invalid code 5 OPERATING MODES 5 1 MONOSTABLE MODE Upon keying in a valid code or when a trigger input activates the output programmed as monostable will activate for the programmed period of time 1 99s While the output is still activated one may ke
3. value may be entered Upon pressing the key the last two entered digits will be considered The time should not always be entered as 2 digits Ex to set the time for 5 s one may press simply 5 If the activation time is set to 0 the output is set as bistable Any other value different from 0 sets the output as monostable 7 4 COMMAND INPUTS PROGRAMMING YELLOW LED 1 To ENTER THE PROGRAMMING MENU press master code blinks slowly 2 beeps the menu option is expected to be entered to exit programming mode press 2 To ENTER THE INPUTS ACTIVATION TIME PROGRAMMING press 3 blinks slowly input number is expected 1 2 to go back to step ipress 3 ENTER INPUT NUMBER TO PROGRAM THE ACTIVATION TIME FOR press input no blinks fast time in seconds is expected 1 99 to go back to step ipress 4 TIME ENTER press time blinks slowly input type is expected O NC 1 NO to go back to step ipress 5 ENTER INPUT TYPE NORMALLY CLOSED OR NORMALLY open O NC 1 NO press input type blinks slowly outputs commanded by input expected 1 2 3 4 to go back to step ipress 6 ENTER OUTPUTS COMMANDED BY INPUT 1 2 3 4 press outputs blinks slowly goes back to step 2 NOTE The time should not always be entered as 2 digits Ex to set the time for 5 s one may press simply 5 If the time is set to 0 the input is instantly activated The setting of the outputs commanded by the inp
4. ansistor 3 output Pin T2 transistor 2 output Pin T1 transistor 1 output Pin Ni not used Pin N2 not used Pin GND connected to GND Pin 12V connected to 12V DC Pin Z1 command input 1 Pin Z1 GND Pin Z2 command input 2 Pin Z2 GND TAMPER pins to be connected to the alarm system APENDIX PROGRAMMING OPTIONS SUMMARY 2K MASTER CODE 1 Appress New cope MopirY App CODE 2K MASTER CODE 2 Appress ERASE USER CODE 2K MASTER CODE 3 Output No Time PROGRAMMING OUTPUTS ACTIVATING TIME gt MASTER CODE 4 Input No Time Entry Type Actvatep Outputs PROGRAMMING INPUTS RESET USERS CODES 2K MASTER CODE 0 USER S MANUAL 1 FEATURES 60 users 4 independent outputs hardware setting as open collector or relay outputs software setting for trigger time 2 programmable trigger inputs 2 operating modes for outputs monostable bistable Programming and operation assisted by visible and audible signals 1 1 Copes KP2 can learn up to 60 user codes and 1 master code All the 61 codes may be programmed The default master code este 000000 Each code may have up to 1 6 digits between 0 9 and for the same code the same digit may occur more than once One or more outputs may be associated to acode Thus a code enter will activate one or more outputs 1 2 OurpuTs The keypad has 4 outputs which may be set either as relay or
5. enter programming mode press master code 9 To exit programming mode press 7 PROGRAMMING The programming menu has the following options 1 key 1 followed by modify add new codes By 2 key 2 followed by erase user codes 3 key 3 followed by set outputs activating time 4 key 4 followed by set inputs 5 key 0 followed by In the following the items to be set are in bold reset all user codes the procedure is written in normal type style the effect is in talics 7 1 CODES PROGRAMMING YELLOW LED 1 To ENTER THE PROGRAMMING MENU press master code blinks slowly 2 beeps se a teapta oppiunea de meniu se iese din modul de programare tastind the menu option is expected to be entered to exit programming mode press 2 To ADD CODES press 1 blinks fast codes address is expected 0 60 to go back to step ipress 3 ADDRESS ENTER press address blinks slowly new code is expected to be entered to go back to step ipress NOTE If the entered address is wrong and the key was not yet pressed the correct address may be entered Upon pressing the key the last two entered digits will be considered 4 KEY IN THE NEW CODE press new code blinks fast waits for for the outputs commanded by code 1 2 3 4 NOTE If the entered code is wrong and the key was not yet pressed the new code may be entered subsequently to go back to step ipr
6. ess 5 KEY IN THE OUTPUTS COMMANDED BY THE CODE 1 2 3 4 press outputs goes back to step 2 blinks slowly The set up of the outputs commanded by code is seen ON LINE 7 2 ERASING USER CODES YELLOW LED 1 To ENTER THE PROGRAMMING MENU press master code blinks slowly 2 beeps the menu option is expected to be entered to exit programming mode press 2 ERASING CODES OPTION press 2 codes address is expected 0 60 to go back to step ipress NOTE the address 0 is ignored 3 ADDRESS ENTER press address blinks fast blinks slowly goes back to previous step NOTE If the entered address is wrong and the key was not yet pressed the correct address may be entered Upon pressing the key the last two entered digits will be considered 7 3 PROGRAMMING THE OUTPUTS ACTIVATION TIME YELLOW LED 1 To ENTER THE PROGRAMMING MENU press master code blinks slowly 2 beeps the menu option is expected to be entered to exit programming mode press 2 OUTPUTS ACTIVATION TIME PROGRAMMING ENTER press 3 output number is expected 1 4 to go back to step ipress blinks slowly 3 ENTER OUTPUT NUMBER TO PROGRAM THE ACTIVATION TIME FOR press output no blinks fast time in seconds is expected 1 99 to go back to step ipress 4 TIME ENTER press time blinks slowly goes back to step 2 NOTE If the entered value is wrong and the key was not yet pressed the correct
7. ut are seen ON LINE 7 5 USERS CODES RESET YELLOW LED 1 To ENTER THE PROGRAMMING MENU press master code blinks slowly 2 beeps the menu option is expected to be entered to exit programming mode press 2 ERASING CODES OPTION press 0 goes back to previous step blinks slowly 8 SYSTEM SET UP TO DEFAULT When the master code is forgotten or it doesn t seem to work the keypad may be set up to default as follows 1 power off the keypad 2 open the case 3 short cut close JP3 jumper 4 power on the keypad all the LED s will be lit 5 press the key subseqently five times Any other key pressed cancel the set up to default procedure 6 open the JP3 jumper The default values set up will be master code becomes 000000
8. y in another code Thus the output timing will be extended to the double of the programmed period 5 2 BISTABLE MODE Upon keying in a valid code or when a trigger input activates the output will activate and will maintain this state until a valid code is entered 6 CODES ENTER A code may have 1 6 digits 0 9 The code enter should always be followed by the key So to enter a code do the following digit digit digit digit digit digit Pressing K key while entering a code is cancelling the digit pressed previously it is the same effect as Esc key on a PC keyboard The entered codes may be classified as master code and users codes The master code comparing to the users codes may program the keypad The master code is always the code with the address 0 and may be modified but not erased A valid code entry is signalized by three short beeps An invalid code entry is signalized by a long beep aproximately 1s NOTES 1 The default master code is 000000 2 The master code is always the code with the address 0 3 The master code allows the access to the programming mode 4 All codes entries must be followed by key 5 Codes have 1 6 digits into the same code the digits may repeat 6 In case the master code is forgotten or doesn t seem to work the keypad may be set to default see chapter SYSTEM SET UP TO DEFAULT 7 2 short beeps confirm the enter in programming mode 8 To