FC-7564 user manual - e

image

Contents

1. gt 51 33 Program Zone i LCD screen address 21 gt dispaly Type 2 a0 LCD screen dispaly Press return to standby interface Note if onlycheck the zonesiren type enterzone thenpress button the LCD willdisplay the sirentype 5 3 Wired zone loop type default resistor loop The options of wired zone loop type 0 gt N O loop zone open loop normal short cut loop alarm 1 gt N C loop zone short cut loop normal open loop alarm User manual Y Other options setting 2 2KQ NC gt 2 gt z no 2 2KQ roc re Eol resistor N G wiring Eol resistor N O wiring For example setthe protection areaNo 6 as N C loop 2 gt Press return to standby interface Note if onlysee the looptype in the wired protection area press to displaythe loop type afterinputting the protectionarea number 5 4 Theresponse speed of wireless protection area default is 500ms Configurable response speed of wireless protectionarea as below For example setthe response speed for protection areaNo 3 is 10ms Screen shows 53 3 Program Zone LCD screen address 1 gt i dispaly gt i me LCD screen dispaly Press return to standby interface Note If onlycan see theresponse speed of wireless areas afterinputting the protection areas No andpress_ itwill display theresponse speed The common
2. 1 thentrigger protection area2 within preset time itwill alarm firsttrigger protection area2 then areal it willnot alarm 2 gt The double direction One Shot mode triggerprotection area 1 protection area 1 alarm trigger protection area 2 firstthen protection area 1 within presettime then it will notalarm trigger protectionarea 1 behindthe preset time the protection area 2 willalarm 3 gt Twice trigger alarm mode one shottrigger protection are 1 or 2 it will notalarm trigger protection areal and 2in preset time separately then protection areal and 2 alarm GSM setting 012345 0 a 70 ua Press return to standby interface Note It canset 3 groupsof cross protectionareas Thecorresponding No is 70 72 6 5 Dial back specific No dial telephoneNo that connected with panel inputthe administrator s password afteroff hook Itwill be on hook automatically and the panelwill call thepreset the telephoneNo which canexecute the armand disarm operation ina long distance For example setthe dial backtelephone No is 12345678 61 12345678 Press return to standby interface VII GSM setting 7 1 GSM module set default is disable 0 gt Disable 1 gt Enable For example setenable GSM module Configurable GSM informationas below 012345 0 80 1 gt LCD screen en Press x A return to standby interface 7 2 GSM information setting defau
3. 1 gt ON User mana system options gt Example set thepanic alarm sound on 39 1 gt IV Code wireless device 4 1 Code wireless remote controller Example auto codenumber 5 remote 012345 ok d 0 40 5 gt Trigger remote dom is the firstnumber of controller remote is 9 digit address code Press return to standby interface 4 2 Auto code wireless detector Example auto codenumber 9 wireless detector gt 201i is the firstnumber of Trig gger wireless is 9 digit address code wirelers detector Press A return to standby interface 4 3 Manual code remote controller Example manual codethe first remotecontroller by enteraddress code ofremote 077230023 012345 0 42 1 gt Press return to standby interface User manual Y system zone setting 4 4 Manual code wireless detector Example manual codethe number 24 wireless detector by enter the address code 035126025 4 5 Deleteremote controller Example delete thenumber 8 remote controller 44 8 gt Program Address LCD screen address code dispaly LCD screen a Press A return to standby interface Note enter Oto delete allremote controller 4 6 Delete detectors Example delete number11 detector 45 11 gt Program Address LCD screen address code dispaly LCD screen Press x return to sta
4. 7 LED display on Metal case sssr sennen 8 C7601 BUS zone expander o 9 Basic operation sss sssr nenn 10 Systemi setings ter dade o A ee E E E EE Er 11 Sei password aro da 12 1 1 Setadministrator password sr tte nenne nenne 12 1 2 Setuser password A A ate he een ra een 12 Ilse CMSnumber ees te Bebe ee a arena Bee ees 12 2 1 Set CMS numbers x as 20a na an da ade a ed 12 DO Set ser Id wate ees ae 24 ae Dan aa a a aa 13 2 3 Free arm telephone number Hr 22s eee ee eee eee 13 2 4 Free disarm telephone number rc tee eee ee 13 2 5 Settheuser telephone number ooo oo een 13 2 6 CMS dialing times Be ee re cas ie A rer OA 14 2 7 Theuser phone dialingtime BEE a a IE RE RER EEE RE BENDER SERIE 14 IIl System options a hth ia te back er 14 3 1 System time setting 224 eee eee ooo 14 3 2 Entry delay time setting eee ee 14 3 3 Setexit delay time lt s see sen eee KE nennen 15 3 4 Siren time e686 084 ann ann a a en 15 3 5 Set ring m s deri he ea ew ER PRE a a a 2G 15 3 6 Detector loss checks sss eee awe a We Wa La wee a as 15 3 7 Communication checking intervaltime gt gt sees ee eee ees 16 3 8 Arm disarm indicationsound e e reer eee eee 16 3 9 Arm disarm report E 16 3 10 Panicalrm sound sr 24a dra a raad EA Roe ad AGO RG 16 IV Code wireless devices ses bre una p un en nn Cee A 17 4 1 Code wireless remote controller e e eee
5. alarm DTMF dial frequency variation lt 1 5 Communication Protocol with CMS Ademco Contact ID Frequency 433MHz 868MHz E Signal transmit distance 100 to 120 meters open area Operation temperature range 32F to 120F 0 C to 45 C gt Storage temperature range 4F to140F 20 C to 60 C Relative humidity 85 at30 86F Maintenance and protection Regular test Design ofcomponents ofthe systemis toreduce maintenance cost butstill itis suggested that periodical check may be carried out The cleanliness of control main machine Main control panel maybe be stained by fingers or covered by dust afterusing fora while Use soft cotton cloth or sponge to clean it Don t use any lubricant liquor such as kerosene acetone and strong gel which will damage appearanceand the tran sparency oftop window ATTENTION Don tuse any lubricant liquor such as kerosene acetone and strong gel which will damage appearance and the top transparency of window User manual Y Limitation ofthe Products Limitation ofthe Products Although the products is a high standard products there is also some limitation of them such as false alarm or no alarm the reasons may be below Lack of Maintenance The system needs maintenance and test regularly test The sensitive of the detectors may decrease and the siren may not whistle Lack of power supply Ifno power input and the back up power is not enough the panel can not work normally Teleph
6. FC 7564 user manual P N 20120815 A FC 7564 WIRING DIAGRAM LED display on pd ESS GSM LED Flash e e e DON DON d a annnnrnn 000 DIT 000000 TUT Dnnanannn OANANANANANA DD D b O OOOO Oo odo Deco Beco Annan b CCCI Z1 GND Z2 Z3 GND Z4 Z5 GND Z6 Z7 GND Z8 AC Ac BELL KEY GND TX RX 12VGND A B IN FIN FIN FIN 13VAC 2A Aux power al 1 A output 2 2K 2 2K 2 2K 2 2K 22K 2 2K 2 2K 2 2K Sess BUS UM MOJA Power supply e Only can usel2V 7Asealed lead acid battery change battery every 3 5 years e With 1keypad power consumption 250mA supportfor 16 workinghrs e Total power consumption keypad auxiliary power siren can t exceed max power consumption of control panel e Max Rechargeable currentof battery 350MA Content Foreword te 1 Eesti rai isa aa a a CHEE a A ee en ER OW ach ee 2 Alarm procedure ee 3 1 Remote control by phone 05 ee tte eee eee 4 2 Follow me operation et rr RER 4 GSM remote operation e 6 GSM alarm receiving ee 6 GSM control via SMS 6 ng EEE WESEL TU ib oe
7. Stay arm thesystem press seven Play the zoneaddress recording pressnine Hand up presszero gt User manual WY GSM remote operation GSM remote operation You can SIM card number then panel will off revised userpassword the default password is 1234 as press todisarm press 2 toarm press 3 tohome arm press 0 tohangup GSM alarm receiving When alarm occurs GSM will callthe preset voicenumber it will voice prompt system is alarm please process the alarm press one tocancel alarming press two tocheck alarm zone press three totrigger siren press five todisarm press six toarm press seven tohome arm GSM control via SMS Arm command PASSWORD 1234SYSTEM ARM Disarm command PASSWORD 1234SYSTEM DISARM Home arm command PASSWORD 1234SYSTEM HOME Status checking command PASSWORD 1234SYSTEM STATUS Cancel alarm command PASSWORD 1234SYSTEM CANCEL Note There is nospace in thecommand password 1234 There is aspace between system and arm enter system arm when operate successfully SMS auto reply Arm Successful Set GPRS accesscommand PASSWORD 1234APN aaaaaa Set GPRS access User name command PASSWORD 1234USER bbbbbb Set GPRS access User code command PASSWORD 1234PWD cccccc Remarks There is no space between APN User manual Rg Keypad Keypad
8. Timecalibration Set password I Set password 1 1 Setadministrator password For example setthe administrator password as 112233 the factory defaultpassword is 012345 012345 0 gt HEER 01 112233 Password LCD screen display 1 2 Setuser password the factory default password 1234 For example set the NO 3 user passwordas 5678 Press return to standby interface NOTE User can set 16 user passwords the program address 02 17 TI Set CMS number 2 1 Set CMS number For example set the CMS number as 9P80012345 012345 0 20 9 80012345 Program Telephone address number Press return to standby interface Note user canset 2 CMSnumbers the program address 20 21 when press LCD screen dispalyasP it means dialpause 2 seconds The dial pauseonly for connecting with extensions otherwise press 80012345 directly set CMS number 2 2 Setuser ID the factory default setting 0000 Example set theuser ID as6666 22 6666 Program User ID address LCD screen display LCD screen dispaly Press return to standby interface 2 3 Free arm telephone number Example set thefree arm telephonenumber as 84113252 62 84113252 2 4 Free disarm telephone number Example set thefree disarm telephonenumber as 84113268 63 84113268 2 5 Setthe usertelephone n
9. an Don t install the panel in the site which has oily fume water vapour muchpoudre eBe keep out ofthe sunand heat Don t install the panel near the heating stove etc high temperature equipment such as spotlight Keep out of the direct sunlight may cause color fading e When cleaning wipe withthe mull Toremove dirt need to use detergent don t use gasolineor paint thinneretc chemicals Or else may causedamage or thepaint scaled off the panel User manual ng Features Zones 8 wired 24wireless 32BUS zone Keypad and remote Support 8 pcs LCD keypad and 8remotes Password 1 installer code 1 duress code 15 user codes CMS 2 CMS follow me numbers 1 account number Voice number 4 voice numbers Voice prompting operation Event log 128 event logs Module expanded GSM GPRS module Recording 10 second automatic message Recording User manual Y Alarm procedure Alarm procedure Telephone telephone Cell phone E 2nd 3rd 4th N 3 The panel will dial 1 4 telephonenumbers as preset If morethan 4 numbers thepanel will start with second telephone number then 3 4 amp N ES gt i BUS AAA ee Alarm software _ Alarm situation found start to send message 3 A D 1 The detector activatedsend CMS alarm information toalarming center 110 alarmcenter hy 2 The panel use Ademco ContactID to send ees alarm information to alarming center If the panel got con
10. arm whenthe user disarmed the system after alarming please disarmthe system again then LCD display will resume lt System setting System setting 012345 amp 10J gt ee System setting display Programming address Set data Data bit System menu and programming address 01 Setadmin password 51 Setsirentype 02 17Setuser password 52 Wiredzone loop type 20 21 Set CMS 53 Wiredzone response time 22 Set userNo 60 Force arm 23 26 Set user phone number 61 Call backspecified number 27 Set CMS dialing times 62 Set freearm phone number 28 Set userphone dialing times 63 Set freedisarm phone number 30 Set systemtime 70 The first group cross zone 31 Setenterdelay time 71 Thesecond group cross zone 32 Set exitdelay time 72 Thethird group crosszone 33 Siren time taa 81 Set GPRS 34 Ring times 82 Alarmpriority 35 Check sensorloss bas ugs 83 Set GSMinfo 36 Communication testingtime i 84 Server IPaddress 37 Arm disarmtone 85 Server port 38 Arm disarmreport 86 Server register ID Sn Tame alarm rong 87 Server register password 40 Autoprogram remote 88 Server connection mode 41 Auto program sensor 89 DTMF outputsignal strength 42 Enter remote code 90 Handshake tone input signal 43 Enter sensorcode strength 44 Delete remote 91 SMS language 45 Delete sensor 98 ACoff delay report 50 Set zonetype 99
11. default Userpassword 1234 Arm User password 1234 Arm Home User password 1234 Home Disarm User password 1234 Disarm Bypass User password 1234 Bypass zone number CH User manual WN LED display on Metal case gt Enter system setting Adminpassword 012345 0 A Exit system setting Password reset Youcan enter installer code 000000 toenter setup only during the first 1 minute when the alarmis powered on LED display on Metal case POWER LED it will normal ON when AC and battery without any trouble It will off when both AC and battery with trouble It will slow flash when battery with trouble itwill quick flash when AC with trouble FAULT LED It will ON when zone troubles ARM LED Itwill ON whenarmed slow flash when stay in DISARM LED Itwill ON when disarmed COMM LED Itwill flash whencommunication trouble ALARM LED Itwill flash whenalarm Zone trouble indication A 08 it means that8 zone alarm F 08 it means that8 zone trouble P 08 it means that8 zone bypass Note if the LCD also display zone alarm whenthe user disarmedthe system after alarming please disarmthe system again then LCD display will resume User manual Y FC 7601 BUS zone expander FC 7601 BUS zone expander Fig 1 1 1 16 18 y y ON 64 32 16 8 4 2 1 1 2 3 4 5 6 7 8 1 FC 7601 is single zone module via dip switch ad
12. description Arm LED Fault LED Power Power LED gt Disarm LED gt Disarm t lt lt Speech indication gt D DD m O O amp Numeric keyboard E Power LED itwill normal ON when ACand battery withoutany trouble Itwill off when both AC and battery with trouble Itwill slow flash when battery with trouble itwill quick flashwhen ACwith trouble Fault LED Itwill slow flash when communication withtrouble it will off when without any troubles Arm LED Itwill ON whenarmed slow flash when stay in quick flash when alarm Disarm LED Itwill ON when disarmed it will OFF when zonetrouble Fire The panel will send out alarm Check Press CHECK key to checkthe signal when pressFIRE key 3 for alarm events it used as Confirme seconds it usedas UP key when key when programming programming When you entering numbers Panic The panel will sendout alarm signal when press PANIC key for 3 seconds it usedas DOWN key when programming press the LCDscreen will display P means 2s pause when dialing forother settings Medica Th twill dass press means EXIT Medical epanel w ll sendout alarm i i signal when press HELP keyfor3 When enter errors press can seconds it usedas DELETE key delete the errors it used as when programming Confirm key whenprogramming Basic operation Factory default Admin password 012345 Factory
13. detector s response speedis 500ms 10msfor High speed detectors and vibration sensors V1 Other options setting 6 1 AC power fault report delay when there is AC powerfault occurs the delay time forreporting to the alarm receiving centre default for 30 minutes For example setthe delay timeof ACpower fault reportis 5 minutes Press A return to standby interface User manual Y Other options setting Note if the delayed time settingis 0 minutes it means thatit will notreport the power fault information 6 2 Timecalibration For example Ifthe panel timeevery 24 hours fast 20 seconds take the formula 20x100 24 83 to calibrate then set this value is 083 If slows 20seconds then it is 183 to calibrate the time 99 083 Press A return to standby interface 6 3 Force arming Allow users toarm when protectionarea faults Inthe state of the arming the protection areas andrecovery information will report to alarm receiving centre Defaultis disable 0 gt Disable force arming 1 gt Enable force arming For example setenable force arming 012345 0 60 1 Press return to standby interface 6 4 Cross protection areas protection area 1 protectionarea 2 time mode Configurable cross protectionarea mode asbelow 0 gt Cancel cross model 1 gt Thedouble direction twice triggermode singletrigger protection areal 2 it will notalarm trigger firstprotection
14. dress EOL 10k 2 Zone expanded NO 1 128 3 Wire red DC Brown DC Yellow A White B Green zone inspection Brown also GND 4 Working voltage DC8 5 24V 5 DIP 1 tamper inspection switch ON to enable tamper OFF to disable tamper 2 8 address digit OFF enable ON disable Binary address To set zone 18 user should be put DIP 4 and DIP 8 to be OFF See fig 1 allmodule address should be plus one 6 The zone number in BUS module module address number 32 Eg Zone 50 module address 18 40 7 Zone 33 64 is disable by factory default user should enable firstly before use V V COM NC V V COM NC TMP TMP y i A Ta B B wog wo HEFE EREE 295 350508 FC 7601 FC 7601 SINGLE ZONE SINGLE ZONE NO TAMPER TAMPER User mana a Basic operation gt Basic operation qe Disarm eble y MOID O n O IR User code 1234 Arm or the away User code 1234 Disarm or the ARM button in the keyfob JA DISARM button on the keyfob J x Emergency E Stay arm edle y m m ia NT LI UL Emergency help press key in thekeyfob User code Stay or press thehome or press Panic andhold for 3s ARM key in the keyfob gt A Note IftheLCD also displayzone al
15. e eee MEET LINE ee 24 7 10 Serverregistered A ee ee ee ee 25 7 11 Serverregistered passwordh eet tree ee ee eee 25 7 12 Server Connection ss aaa iek aa ran ces 25 Technical specification A A A A IS da 26 Maintenance and protection A AS a dere A ee 26 Limitation of the Products saa aus a e688 ee hee cia dann 27 User manner ng ae Foreword FC 7564 isa intelligent alarm control system which in tegrated with burglarproof fireproof gas leak proof It is compatible with wired and wireless alarm mode FC 7564 refers to the most advanced coding techniques of BUS zone and multi bit random code hopping techniques in security amp reliability to avoid false alarm and interference effectively 1 64 zones 8 wired 24 wireless and 32 BUS zone 2 6 way to arm and disarm the system User code Keyfob Phone SMS Auto timer CMS 3 Alarm notification When alarm occurs user can have alarm notification by phone call SMS GPRS TCP IP optional Smart feature of FC 7564 1 Multi zones combination alarm special design for the places suchas watchroom bedromm and etc 2 Can use without keypad 3 LED display on metal case easier for user to check system info Warning eDon t disassemble or modify or else may be lead to danger and the damage ofpanel e Be sure not to cause to break by falling or throwing down or strong impacting Notinstall near themagnetic field may because instability e Keep dry andcle
16. eee eee moroso 17 4 2 Auto code wireless detector teeter ee eee eee ee d7 4 3 Manual code remote controller see ooo eee ed 17 4 4 Manual code wireless detector lt lt lt lt o mo 18 4 5 Delete remotecontroller ee srra iat mat e mie eee 18 4 6 Delete detectors mar re Taani EAn a ae a E Nee 18 VS ystem Zone setting 2 phd haette 18 5 1 Zone typesetting isre como un Saud an oe he an we 19 5 2 Zone siren typesetting seati 2222 vee eae ran age 19 5 3 Wired Zone loop type se conocia e nen 19 5 4 Theresponse speed of wireless ee eee eee eee eee 20 V1 Other optionssetting 2448224 aaa aut au os Bar ee oe 20 6 1 AC powerfaultreportdelay e sere ee eee eee eee 20 6 2 Time calibration 2 3 dre roads wa ae e os 21 6 3 Force arming E dh bh Aas ee dap cae Sion 21 6 4 Cross protection areas lt lt ee nn 21 6 5 Dial back specific Number errimen 208 asa caw a ea ea 92 VILGSM setting E e is ee E id sar cde Ao gdh Gs ae ee shy else dee sey cie de 22 TIGSM moduleset 2 sn He A ene 22 7 2 GSM information setting 655 s ss bee eee ee eee eee 22 7 3 Alarm priorities sense nenn 23 7 4 GSM message language e eee ees 23 7 5 DTMF output signal strength lt lt lt o andorra sa 23 7 6 Handshake voice input signal strength rer rennen 24 7 7 GPRS setting 2 e oooomomorsnsn ee 24 7 Server IP ddress s coronas Ble awa a A 24 CCC Meee o
17. ered IDis 75640001 012345 01 gt 86 75640001 Program User ID address j 1 LCD screen dispaly LCD screen a Press return to standby interface 7 11 Serverregistered password For example setServer registered passwordis 12345678 012345 EN 0 87 12345678 Press A return to standby interface 7 12 Serverconnection defaultis long connection Configurable comection methodmode as below 0 gt Long connection 1 gt Short connection For example setconnection is shortone 88 1 gt Press return to standby interface Note Enable GPRS function need toenable GSM module Long connection donot deal with SMS voice callingand Server via GPRS long connection Short connection whenit have voicecalling and SMS the system will cut off connection with GPRS and deal with the voice calling and SMS priority When this isdone GPRS will connect with Server automatically Server registered ID and password GPRS can registered musthave the correctID and password that registeredin the Server it mustbe 8 digitals for the ID and passwords Technical specification gt Technical specification General data External AC power supply vdtage Input 185 230VAC Output 13 VAC 2A Backup power supply duration 16 hours Backup battey optiond 12V 7AH The method of alarming dial Telephonealarm GSM alarm and GPRS
18. erface 3 6 Detector loss check the default setting is00 as Disable Example set the detectorloss check timeas 4hours 012345 0 35 04 gt I A Press return to standby interface User manual system options Note wireless detectorsend status reportabout every 3 hours The panel check ifreceiver the status reportsignal or alarmsignal from detectorat programed time If not receive the singal will judge detectorloss We suggest setthe neterval timeof detector inspection longerthan 4 hours 3 7 Communication checking interval time It is checking of communication betweenalarm panel andCMS To check ifthe communication is normal defaultis 00 notchecking Example set the communication checking intervaltime as 15 hours 36 015 gt 3 8 Arm disarmindication sound Toset if thesiren sound whenuser use remote controller to arm disarmthe panel default not sound 0 gt not sound 1 gt sound Example set the arm disarm indication sound on 37 1 gt 3 9 Arm disarm report default not report to CMS 0 gt not report 1 gt report Example set arm disarmreport CMS 38 1 gt Program LCD screen address l gt Report dispaly LCD screen dispaly Press l A return to standby interface 3 10 Panicalrm sound Toset ifthesiren sound whentrigger the panicbutton on remotecontroller or emergency buttonon keypad default OFF 0 gt OFF
19. firmation from center then alarm successfully Otherwise the panel will repeat alarm The alarm information will be display andreslove by the alarm center computer software User manual Y Remote control by phone 1 Remote control by phone IS When useranswer the call the panel User to call landlines phone whichiconnectto thepanel pick up phone after preset rinings ig oog Welcometo your security Enter the usercode as pervoice system Enteryour usercode prompting factory default code 1234 System disarm pressone 4 System arm presstwo gt System home arm press three Play the zoneaddress recording pressnine Hang up presszero 2 Follow me operation When the detectoris triggered thepanel will soundalarm and displaythe triggered zone number andalarm type onthe LCD screen The panel will give aalarm and dial the preset voicenumbers ifthepanel received thealarm The user canhear indication after he took the phone The useroperate follow the voice indication to disarm arm inquire and mornitor y O y gt K Panel receivealarm Send thealarm signal and dialvoice number E E Follow me operation User answerthe call 4 Cancel the alarm press one Check alarm zone press two Activate the hoot press three To disable the siren press four Disarm system press five Arm the system press six
20. lt is SMS voice calling 0 gt SMS voice calling 1 gt SMS 2 gt Voice calling For example setonly can dialvoice calling GSM setting 83 2 Program Type LCD screen address 2 dispaly LCD screen ved Press x return to standby interface 7 3 Alarm priorities default is GSM priority 0 gt GSM priority 1 gt PSTN priority For example settelephone line is priority 82 1 Press return to standby interface 7 4 GSM message language default is Chinese Configurable SMS languageas below 0 gt Chinese 1 gt English For example setmessage as English 012345 0 91 1 7 5 DTMF output signal strength default is 04 For example setDTMF output signalstrength is 05 012345 0 89 05 Program Signal LCD screen address stregth re dispaly LCD screen A Press return to standby interface GSM setting 7 6 Hand skake voice input signal strength defaultis 60 For example sethandshake voice inputsignal strength is 70 90 70 7 7 GPRS setting defaultis disable 0 gt Disable 1 gt Enable For example setenable GPRS function 012345 0 81 1 7 8 Server IP address For example setServer IP address is 202 101 78 2 7 9 Server port For example setServer port 1503467 85 03467 GSM setting 7 10 Serverregistered ID For example setserver regist
21. ndby interface Note enter 00to delete alldetectors V System zone setting 5 1 Zone type setting Options of zonetype as below 0 gt disable 1 gt delay 2 gt perimeter 3 gt burglar 4 gt 24 hours 5 gt emergency 6 gt fire alarm For example set protection area 7and 8 asone group ofthe double direction one shot mode cross protectionarea Preset timeis 50 seconds User manual Y system zone setting Burglar alarm zone only triggerunder system armstatus delay and perimeter zone trigger under stay or arm status 24 hours emergency and fire alarm zone will trigger under any system status Factory default Wired zone 1 8 enable wireless zone 9 32 enable bus zone 33 64 disable 00 is system zone Pls connect resistor 2 2k to wired zone before power on the alarm panel otherwiset he alarm panel will make alarm or cause zone trouble When need use bus zone 7601 one zone expand module is required Example set the number 59 zone as fire alarm zone 012345 0 gt 50 59 Program Zone LCD screen address dispaly 6 gt Type Press return to standby interface Note If onlycheck the zonetype then enterzone number then press button The LCD will display the zone type 5 2 Zone sirentype setting default continious sound The options ofsiren type 0 gt mute 1 gt continious sound 1 gt pulse tone Example set zone 33siren type aspulse tone 012345 01
22. one Line False If the telephone line is cut the panel could not send alarm signals Limitation of Smoke Detectors ifthe smoke is far from the smoke detector the detector could not alarm If the intruder break in through some door or window not monitored or some one knows hot to make the system not work
23. umber Example set the NO 3 user telephonenumber as 93872105 25 93872105 Press x d A return to standby interface Note user can set4 user telephone numbers the program address 23 26 system options 2 6 CMS dialing times The default settingis 5 times Example set the dialingtime as 4times 27 04 2 7 The user phone dialing time the default setting is 5 times Example set the dialing time as3 times 28 03 III System options 3 1 System time setting Example set thesystem time and date as 10 01 July 11 2012 YM D HM YearMonth a Hour Minute Press return to standby interface 3 2 Entry delay time setting after triggerd the delay zone panel start alarming the default setting is 10 seconds Example set the entry delay timeas 15 seconds 012345 ok d 0 31 015 Program Time LCD screen address dispaly LCD screen dispaly Press return to standby interface system options 3 3 Set exit delay time the default setting is 10seconds Example set theexit delay timeas 15 seconds 32 015 gt 3 4 Sirentime the default setting is 5mins Example set thesiren time as 10 mins 33 10 gt 3 5 Setring time the default time is 7times Example set thering time as5 times 34 05 Program Time LCD screen address dispaly LCD screen Press A return to standby int