Home

Operating Instructions PTB 03 ATEX 1030 X

image

Contents

1. fran ais PTB 03 ATEX 1030 X Caract ristiques techniques fonctionnement en toute s curit burkert FLUID CONTROL SYSTEMS 6 3 5 Protection e La composition des signes distinctifs de protection allumage s oriente sur les modes de protection allumage des composants respectivement utilis s Il 2 G Ex d e IIC T4 resp T5 ll 2 D Ex tD A21 IP 65 T135 C resp T100 C Il 2 G Ex d e mb IIC T4 Il 2 D Ex tD A21 IP65 T135 C Electro aimant avec ou sans coffret bornes Electro aimant avec coffret bornes et fusible Electro aimant sans coffret bornes avec d tecteur de proximit Il 2 G Ex d e ia IIC T4 resp T5 ll 2 D Ex tD A21 IP65 T135 C resp T100 C Il 2 G Ex d e ia mb IIC T4 II 2 D Ex tD A21 IP65 T135 C Electro aimant avec coffret bornes fusible et d tecteur de proximit 6 4 Caract ristiques techniques g n rales 6 4 1 Caract ristiques lectriques Type TI VR un Classe de temp rature T4 T5 Type de courant tous courants tous courants Tension nominale 24 240 V 24 240 V Tol rance de tension 10 10 10 10 Courant de calcul 0 085 0 014 A 0 085 0 014 A Courant 01 66 0 166 A 01 66 0 166 A d actionnement Puissance d attraction 40 W 40 W Puissance de maintien 3 W 3W en r gime tabli R gime de charge max 20 min 10 min env
2. Warning notices Type label coil Type label IEC Ex IEC Ex PTB 05 0026X Ex de IIC T5 lex tD A21 IP65 T100 C Protection class Temperature class IEC EX Approval number Fig 1 Location of the type label Type and design Protection class Temperature class PTB approval PTB 03 ATEX 1030X I26 ExXdeIICTS Dan Ex tO Al IP65 UL 780 PD30 220 240V AC DC40 3W S N 6917 CE0 102 _ 00627696 W37uA Ld burkert D 74653 Ingelfingen Id number of the coil Date of manufacture Serial number of the coil Inspection body Voltage 10 Current type Power consumption Fig 2 Description of the type label 6 3 4 Dimensions Connection type Length Width Height mm mm mm Molded in cable 96 32 56 Terminal box with 123 60 113 without safety fuse PTB 03 ATEX 1030 X Technical data Safe operation burkert FLUID CONTROL SYSTEMS 6 3 5 Type of explosion protection The composition of the explosion protection code follows the explosion protection types of the components used in each case Solenoid with or without terminal box Il 2 G Ex d e IIC T4 resp T5 Il 2 D Ex tD A21 IP 65 T135 C resp T100 C 6 4 General Technical Data 6 4 1 Electrical Data Type 7 E Temperature class T4 T5 Type of current Universal Universal Rated voltage 24 240 V 24
3. la charge lectrostatique Il y a risque d explosion en cas de d charge soudaine d appareils ou de personnes charg s d lectricit statique dans des zones pr sentant des risques d explosion Par des mesures appropri es assurez vous qu il ne peut y avoir de charges lectrostatiques dans de telles zones Nettoyez la surface de la soupape languette uniquement en essuyant l g rement avec un chiffon ou antistatique humide Situations dangereuses d ordre g n ral Pour pr venir les blessures respectez ce qui suit L actionnement par inadvertance de l installation ne doit pas tre possible Aucune modification non autoris e ne doit tre apport e au syst me Les travaux sur le syst me doivent tre ex cut s uniquement par du personnel qualifi et form disposant de l outillage appropri L appareil doit tre utilis uniquement en parfait tat et en res pectant le manuel d utilisation Les r gles g n rales de la technique sont d application pour planifier l utilisation et utiliser l appareil 4 INDICATIONS G N RALES 4 1 Adresses Allemagne B rkert Fluid Control Systems Sales Center Chr B rkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com International Les adresses se trouvent aux derni res pages de ces instructions de service imprim es Egalement sur internet sous www burkert com
4. 240 V Solenoid with terminal box and fuse Il 2 G Ex d e mb IIC T4 Il 2 D Ex tD A21 IP65 T135 C Solenoid without terminal box with proximity switch Il 2 G Ex d e ia IIC T4 resp T5 ll 2 D Ex tD A21 IP65 T135 C resp T100 C Solenoid with terminal box fuse and proximity switch Il 2 G Ex d e ia mb IIC T4 Il 2 D Ex tD A21 IP65 T135 C Voltage tolerance 10 10 10 10 Rated current 0 085 0 014 A 0 085 0 014 A Pick up current 01 66 0 166 A 01 66 0 166 A Pick up power 40 W 40 W Power consumption for 3 W 3W holding in equilibrium Max number of 20 min 10 min switching actuations ca 6 4 2 Electrical connection Version Execution Internal code Code PD30 Permanently installed rubber sheathed JWxx cable of Type HO5 RN F3G0 75 Care Lie 11 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Assembly and disassembly Version Execution Internal code Code Terminal box with cable bushing M20 JAO2 x 1 5 without fuse Terminal box with threaded nipple M20 x JA08 1 5 without fuse PD30 Terminal box with threaded nipple NPT JA09 1 2 without fuse Terminal box with threaded nipple G 1 2 JA10 without fuse Terminal box with cable bushing M20 x JAO1 1 5 and fuse Terminal box with threaded nipple M20 x JA05 1 5 and fuse PD29 Termina
5. 0 200 A 153731 0 315 A 153733 0 400 A 153734 0 500 A 153735 0 630 A 153736 0 800 A 153737 A deutsch 29 burkert FLUID CONTROL SYSTEMS PTB O3 ATEX 1030 X Transport Lagerung Entsorgung Sicherung Bestellnummer Typ 1058 1 000 A 153738 1 250 A 153739 1 600A 153746 2 000 A 153740 3 150 A 153742 deutsch 11 TRANSPORT LAGERUNG ENTSORGUNG HINWEIS Transportschaden Unzureichend gesch tzte Ger te k nnen durch den Transport besch digt werden Ger t vor N sse und Schmutz gesch tzt in einer sto festen Verpackung transportieren e Eine ber bzw Unterschreitung der zul ssigen Lagertempe ratur vermeiden Falsche Lagerung kann Sch den am Ger t verursachen Ger t trocken und staubfrei lagern Lagertemperatur 40 60 C Umweltsch den durch von Medien kontaminierte Ger teteile Ger t und Verpackung umweltgerecht entsorgen Geltende Entsorgungsvorschriften und Umweltbestimmungen einhalten PTB 03 ATEX 1030 X burkert FLUID CONTROL SYSTEMS 6 Appareils avec mode de protection Il 2G D Ex PROPOS DE CE MANUEL 11 SYMbOlGS eegene UTILISATION CONFORNE seenen 33 2 1 Din E TE 33 2 2 Homologation E eege ea 33 2 3 Remarques particuli res dans une zone pr sentant des risqu s d exploSion 2u seinen 34 CONSIGNES DE S CURIT FONDAMENTALES 34 INDICATIONS G N RALES
6. 6 4 2 Raccordement lectrique Code Version Code interne d ex cution PD30 Conduite flexible en caoutchouc FX WA Xx mont e fixe du type HO5 RN F3G0 75 39 burkert FLUID CONTROL SYSTEMS PTB O3 ATEX 1030 X Montage et D montage Code Version Interner d ex cution Code Bo te de connexions avec passe JA02 c ble vis M20 x 1 5 sans fusible Bo te de connexions avec raccord JA08 filet M20 x 1 5 sans fusible PD30 Bo te de connexions avec raccord JAO9 filet NPT 1 2 sans fusible Bo te de connexions avec raccord JA10 filet G 1 2 sans fusible Bo te de connexions avec passe JAO1 cable a vis M20 x 1 5 et fusible Bo te de connexions avec raccord JAO5 filet M20 x 1 5 et fusible PD29 Bo te de connexions avec raccord JAO6 filet NPT 1 2 et fusible Bo te de connexions avec raccord JAO7 filete G 1 2 et fusible At La ligne de raccordement de I lectro aimant Type 7 doit tre pos e fixe et de mani re ce qu elle soit suffisamment l abri de d t riorations m caniques Passe c ble vis selon certificat d essai de type s par 7 Fusible PD29 selon le certificat d essai de mod le type CE s par Diff rentes longueurs de c ble 7 MONTAGE ET D MONTAGE 7 1 Consignes de s curit DANGER Danger d explosion L appareil est un syst me ferm L appareil ne doit pas tre d mont fau
7. A deutsch 17 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Bedienungsanleitung 1 BEDIENUNGSANLEITUNG Die Bedienungsanleitung beschreibt den gesamten Lebenszyklus des Ger ts Bewahren Sie diese Anleitung so auf dass sie f r jeden Benutzer gut zuganglich ist und jedem neuen Eigent mer des Ger ts wieder zur Verf gung steht Die Bedienungsanleitung enthalt wichtige Informationen zur Sicherheit Das Nichtbeachten dieser Hinweise kann zu gefahrlichen Situationen f hren Die Anleitung muss gelesen und verstanden werden Lesen Sie die Bedienungsanleitung vor dem Einsatz des Ger ts sorgfaltig durch Beachten Sie vor allem die Kapitel Bestimmungsgem e Verwendung und Allgemeine Sicherheitshinweise sowie das Kapitel Einsatzbedingungen deutsch 1 1 Darstellungsmittel Fur die Kennzeichnung wichtiger Informationen werden in der Anleitung folgende Darstellungsmittel verwendet GEFAHR Warnt vor einer unmittelbaren Gefahr Bei Nichtbeachtung sind Tod oder schwere Verletzungen die Folge WARNUNG Warnt vor einer m glicherweise gef hrlichen Situation Bei Nichtbeachtung drohen schwere Verletzungen oder Tod VORSICHT Warnt vor einer m glichen Gef hrdung Nichtbeachtung kann mittelschwere oder leichte Verletzungen zur Folge haben HINWEIS Warnt vor Sachsch den Bei Nichtbeachtung kann Ger t oder Anlage besch digt werden Bezeichnet
8. Arbeiten am elektrischen System d rfen nur von ausgebildeten Elektrofachkr ften durchgef hrt werden Vor Beginn der Arbeiten in jedem Fall die Spannung abschalten und diese vor Wiedereinschalten sichern Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten Vorgehensweise Elektrische Verbindung trennen gt Ventilgeh use von der Rohrleitung trennen HINWEIS Funktionsst rungen durch Verschmutzung Bei Neuinstallation altes PTFE Band an den Anschl ssen ent fernen Reste oder Teile des Bandes d rfen nicht in die Rohrleitung gelangen en 8 INBETRIEBNAHME WARNUNG Verletzungsgefahr bei unsachgem em Betrieb Nicht sachgem er Betrieb kann zu Verletzungen sowie Sch den am Ger t und seiner Umgebung f hren Vor der Inbetriebnahme muss gew hrleistet sein dass der Inhalt der Bedienungsanleitung dem Bedienungspersonal bekannt ist und vollst ndig verstanden wurde Die Sicherheitshinweise und die bestimmungsgem e Verwen dung m ssen beachtet werden Nur ausreichend geschultes Personal darf die Anlage das Ger t in Betrieb nehmen Stellen Sie vor Inbetriebnahme sicher dass das Ger t vorschriftm ig installiert wurde der Anschluss ordnungsgem ausgef hrt wurde das Ger t nicht besch digt ist alle Schrauben fest angezogen sind PTB 03 ATEX 1030 X Wartung Reparatur Fehlerbehebung burkert FLUID
9. DANGER Risk of injury due to electrical shock Before reaching into the system switch off the electrical power supply and secure to prevent reactivation Observe applicable accident prevention and safety regulations for electrical equipment If the protective conductor contact between coil and body is missing there is danger of electrical shock Always connect protective conductor Check electrical continuity between coil and body 13 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Start up The connection cable is encapsulated with the coil and cannot be removed gt Attach the electrical connection 7 4 Disassembly DANGER Risk of electric shock There is a serious risk of injury when reaching into the equipment Only trained electrical engineers may work on the electrical system Before starting work always switch off the power supply and safeguard to prevent re activation Observe applicable accident prevention and safety regulations for electrical equipment Procedure Disconnect the power connection Disconnect the valve body from the pipeline NOTE Malfunctions as a result of contamination Incase of new installation remove old PTFE tape from the connec tions Residues or parts of the tape must not get into the pipeline 8 START UP 8 1 Safety Instructions WARNING Danger due to improper operation Improper operation may
10. PTB 03 ATEX 1030 X Assembly and disassembly burkert FLUID CONTROL SYSTEMS DANGER Danger of high voltage Acute risk of injury from hazardous structure borne voltage Risk of damage to the device due to short circuit Before starting work switch off the power supply and secure to prevent it being switched on again Live terminals in the terminal box can cause electric shock short circuit or explosion Switch off the power supply before open ing the terminal box The connecting cables to the electromagnets must be secure and be laid so that they are adequately protected from mechani cal damage Observe the applicable accident prevention and safety regula tions for electrical devices WARNING Danger high pressure Interventions in the pneumatic system represent an acute risk of injury First switch off pressure before disconnecting lines and valves Observe the flow direction during installation Observe the applicable accident prevention and safety regula tions for pneumatic systems 7 2 Installation of valve Q The solenoid valve can be mounted in any position Preferably with solenoid system mounted at the top Procedure Clean pipelines Connect a dirt trap upstream gt Seal pipeline connections with PTFE tape gt Screws in pipelines Q Make certain the direction of flow is correct Check valve for leakage 7 3 Electrical connection
11. bornes Avant de commencer une intervention couper la tension et assurer une protection contre la remise en marche de l appareil Les lignes de raccordement des lectro aimants doivent solides et pos es de mani re tre suffisamment prot g es contre des dommages d origine m canique Respecter les r gles de pr vention des accidents et de s curit en vigueur pour les appareils lectriques DANGER Danger d la haute pression ll y a risque important de blessures lors d interventions sur le syst me Les interventions sur le syst me pneumatique ne peuvent tre r alis es que par un personnel sp cialis et form cet effet et l aide des outils appropri s Couper d abord la pression puis d tacher les c bles et les vannes Respecter les r gles de pr vention des accidents et de s curit en vigueur pour les appareils pneumatiques 7 2 Installation de la vanne Q La position de montage de l lectrovanne est indiff rente De pr f rence avec le syst me magn tique en haut Proc dure suivre Nettoyer les tuyauteries Monter le panier en amont Etancher les raccords de la tuyauterie avec une bande PTFE gt Visser les tuyauteries Q Respecter le sens du d bit Contr ler l tanch it de la vanne 7 3 Raccordement lectrique DANGER Risque de choc lectrique Avant d intervenir dans le syst me couper la tension et
12. burkert Allgemeine Sicherheitshinweise 2 3 Besondere Hinweise im Ex Bereich 3 ALLGEMEINE WARNUNG SICHERHEITSHINWEISE Diese Sicherheitshinweise berticksichtigen keine i Getahrdureniclektrestatsche Aufladung Zuf lligkeiten und Ereignisse die bei Montage Betrieb und Wartung Bei pl tzlicher Entladung elektrostatisch aufgeladener Ger te oder der Ger te auftreten k nnen Perenen besten n Ex Bersichiexplosion gelalr ortsbezogenen Sicherheitsbestimmungen f r deren Einhaltung Durch geeignete Ma nahmen sicherstellen dass es im Ex auch in Bezug auf Montagepersonal der Betreiber verantwortlich ist Bereich zu keinen elektrostatischen Aufladungen kommen kann Die Ger teoberfl che nur durch leichtes Abwischen mit einem A feuchten oder antistatischen Tuch reinigen Explosionsgefahr Das Ger t ist Teil eines geschlossenen Systems und darf nicht an Weitere Besondere Bedingungen finden Sie unter 5 1 in w hrend des Betriebs demontiert werden dieser Bedienungsanleitung Gefahr durch elektrische Spannung Akute Verletzungsgefahr durch gef hrliche Korperspannung Gefahr der Besch digung des Ger ts durch Kurzschluss Vor Eingriffen in das Ger t oder die Anlage Spannung abschal ten und vor Wiedereinschalten sichern Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten Gefahr durch hohen Druck Bei Eingriffen in das System besteht akute Verletzungsgef
13. burkert com english 5 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X General Safety Instructions 2 3 Special instructions in explosion risk areas WARNING Danger caused by electrostatic charge If there is a sudden discharge from electrostatically charged devices or persons there is a danger of explosion in the explosion risk area Take appropriate measures to prevent electrostatic charges in explosion risk areas Clean the device surface by gently wiping it with a damp or antistatic cloth only AN Additional special conditions can be found under 5 1 of LE these operating instructions 3 GENERAL SAFETY INSTRUCTIONS These safety instructions do not take into account any contingencies or events which may occur during the installation operation and maintenance of the devices local safety regulations the observance of which is the responsibility of the operator also with respect to the installation personnel A Danger of explosion The device is a sealed system It must not be opened Danger of electrostatic charge Acute risk of injury from hazardous structure borne voltage Risk of damage to the device due to short circuit Before starting work switch off the power supply and secure to prevent it being switched on again Observe the applicable accident prevention and safety regula tions for electrical devices Danger high pressure There is a seri
14. emp cher toute remise sous tension par inadvertance Veuillez respecter les r glementations en vigueur pour les appareils lectriques en mati re de pr vention des accidents ainsi qu en mati re de s curit Il y a risque de choc lectrique en l absence d un contact du conducteur de protection entre la bobine et le corps Toujours raccorder le conducteur de protection Contr ler le passage du courant entre la bobine et le corps 41 burkert FLUID CONTROL SYSTEMS PTB O3 ATEX 1030 X Mise en service Le c ble de raccordement est surmoul avec la bobine et ne peut pas tre d mont R aliser le raccordement lectrique 7 4 D montage DANGER Danger pr sent par la tension lectrique ll y a risque important de blessures lors d interventions sur l installation Les travaux sur le syst me lectrique doivent tre effectu s uni quement par des lectriciens qualifi s Avant d effectuer des travaux coupez toujours la tension et emp chez toute remise sous tension par inadvertance Veuillez respecter les r glementations en vigueur pour les appareils lectriques en mati re de pr vention des accidents ainsi qu en mati re de s curit Proc dure suivre gt Couper la connexion lectrique gt S parer le corps de vanne de la tuyauterie REMARQUE Dysfonctionnements dus l encrassement Lors d une nouvelle installation enl
15. l lectro aimant le fusible est mont dans la bo te de connexions de l appareil a Vous trouverez une description plus d taill e des versions au chapitre 6 Caract ristiques techniques fonctionnement en toute s curit Fusible A 5 1 2 Fonctionnement avec corps de soupape s y rattachant Les bobines magn tiques des type 77 78 ne doivent tre mise en uvre qu avec le corps de vanne s y rattachant On peut utiliser comme corps de vanne les mati res suivantes m tal p ex laiton acier sp cial ou mati re plastique e ex polyamide PVC PTFE Commande manuelle d tecteur de proximit 5 1 3 Linduit de l aimant peut tre manoeuvre a la main par le bouton poussoir En pressant et tournant de 90 le bouton poussoir est bloqu Alternativement la commande manuelle l lectro aimant peut tre quip d un d tecteur de proximit Le code interne pour cette version est CF 15 fran ais PTB 03 ATEX 1030 X Caract ristiques techniques fonctionnement en toute s curit burkert FLUID CONTROL SYSTEMS Ex cution avec bo te bornes DANGER 5 1 4 Risque d explosion Uniquement des c bles et des lignes d termin s doivent tre introduits L exploitant doit assurer une d charge de traction correspondante e Des lignes ayant un diam tre ext rieur de 6 mm 13 mm peuvent tre utilis es Tenir compte de la char
16. les limitations ventuelles existantes 2 2 Homologation Ex L homologation Ex n est valable que si vous utilisez les modules et composants homologu s par B rkert tel que cela est d crit dans ces instructions de service La soupape languette peut tre utilis e uniquement avec les com posants suppl mentaires autoris s par Burkert sinon l homologation Ex devient caduque L homologation Ex devient galement caduque si vous apportez des modifications non autoris es l appareil aux modules o aux composants Le certificat d examen CE de type PTB 03 ATEX 1030 X et le certi ficat de conformit IECEx PTB 05 0026X ont t tablis par PTB Physikalisch Technische Bundesanstalt Bundesallee 100 38116 Braunschweig qui effectue galement l audit de production CE 0102 Vous trouverez le certificat d essai de mod le type CE sur Internet sous www burkert fr 33 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Consignes de s curit fondamentales 2 3 Remarques particuli res dans une zone pr sentant des risques d explosion AVERTISSEMENT Risque d la charge lectrostatique ll y a risque d explosion en cas de d charge soudaine d appareils ou de personnes charg s d lectricit statique dans des zones pr sentant des risques d explosion Par des mesures appropri es assurez vous qu il ne peut y avoir de charges lectrostatiques dans de telles zones Nettoyer
17. maximale thermische Belastung der eingef hrten Kabel bzw Leitungen beachten Die eingelegte ausbrechbare Dichtung muss dem Durchmesser des Kabel Leitung angepasst werden Der Bemessungsquerschnitt der Kabel Leitungsadern muss min destens 0 75 mm betragen und darf 2 5 mm nicht berschreiten Die Schrauben zur Befestigung des Deckels des Klemmenkas tens m ssen mit einem Anziehdrehmoment von 1 Nm 5 angezogen werden Die Magnetspulen d rfen auch mit einem Klemmenkasten wahlweise mit ohne Sicherung ausgef hrt werden Sicherung nach getrennter Baumusterpr fbescheinigung Als Schutz gegen unbeabsichtiges ffnen des Deckels tr gt dieser die Aufschrift Nur spannungsfrei ffnen 6 TECHNISCHE DATEN SICHERER BETRIEB 6 1 Konformit t Die Magnetspule Typ 0770 0780 ist konform zu den EG Richtlinien entsprechend der EG Konformit tserkl rung 6 2 Normen Die angewandten Normen mit denen die Konformit t mit den EG Richt linien nachgewiesen wird sind in der EG Baumusterpr fbescheinigung und oder der EG Konformit tserkl rung nachzulesen 6 3 Betriebsbedingungen GEFAHR Explosionsgefahr durch berschreitung technischen Daten berschreitung der auf dem Typschild angegebenen technischen Daten f hrt zu hohem Risiko Auf dem Typschild angegebenen technischen Daten keinesfalls berschreiten 6 3 1 Maximal zul ssiger Umgebungstemperaturbereich Bitte beachten Sie f
18. ndschutzarten der jeweils verwendeten Komponenten Voraussetzungen f r den sicheren und einwandfreien Betrieb sind sachgem er Transport sachgem e Lagerung und Installation sowie sorgf ltige Bedienung und Instanthaltung Eine andere oder dar ber hinausgehende Benutzung gilt als nicht bestimmungsgem F r hieraus resultierende Sch den haftet B rkert nicht Das Risiko tr gt allein der Anwender Das Ger t nur bestimmungsgem einsetzen 2 1 Beschr nkungen Beachten Sie bei der Ausfuhr des Systems Ger ts gegebenenfalls bestehende Beschr nkungen 2 2 Ex Zulassung Die Ex Zulassung ist nur g ltig wenn Sie die von B rkert zugelassenen Module und Komponenten so verwenden wie es in dieser Bedienungs anleitung beschrieben ist Die Magnetspule Typ 0770 0780 darf nur in Kombination mit den von B rkert freigegebenen Zusatzkomponenten eingesetzt werden andernfalls erlischt die Ex Zulassung Nehmen Sie unzul ssige Ver nderungen am Ger t den Modulen oder Komponenten vor erlischt die Ex Zulassung ebenfalls Die EG Baumusterpr fbescheinigung PTB 03 ATEX 1030 und das IECEx Certificate of Conformity IECEx PTB 05 0026X wurde von der PTB Physikalisch Technische Bundesanstalt Bundesallee 100 38116 Braunschweig ausgestellt die auch die Fertigung auditiert CE 102 Die EG Baumusterpr fbescheinigung finden Sie im Internet unter www buerkert de A deutsch 19 Kee PTB 03 ATEX 1030 X
19. result in injuries as well as damage to the device and the area around it Before start up ensure that the operating personnel are familiar with and completely understand the contents of the operating instructions In particular observe the safety instructions and intended use The device may be started by adequately trained personnel only Before commissioning ensure that The device has been correctly installed The connections have been correctly made The device is not damaged All bolts are securely tightened PTB 03 ATEX 1030 X Maintenance Repair Troubleshooting burkert FLUID CONTROL SYSTEMS 9 MAINTENANCE REPAIR TROUBLESHOOTING Maintenance and repair DANGER Danger due to improper maintenance repair and inspection work The maintenance and inspection work on the device may be carried out by authorized technicians only and with the appropriate tools Repairs on the device may only be carried out by the manufacturer When performing repair or maintenance work on the system the valve may not be opened and the protective conductor connection may not be disconnected 9 2 Troubleshooting In the event of faults make sure that the device has been installed according to the specifications the connection has been established properly the device is not damaged e all screws have been tightened the voltage and pressure have been switched on the pipe
20. ssc sscsasintiscsiiuiisisniainiaindassisin tinca 35 K 35 AH Garantie galoni 35 4 8 Informations sur Internet 35 CONDITIONS D EMPLOI DES APPAREILS nuneoeeemmns 36 5 1 Conditions particuli res CARACT RISTIQUES TECHNIQUES FONCTIONNEMENT Giele 37 6 1 COM ONI s same 37 6 2 Normes SR 6 3 Conditions d exploitation 37 6 4 Caract ristiques techniques g n rales ENEE 39 7 MONTAGE ET DEMONTAGE mms 40 7 1 Consignes de s curit sinus 40 7 2 Installation de la Man user dere 41 7 3 Raccordement lectrique 41 1 4 DEMONTAGE ER ue els 42 8 MISE EN SERVICE tennis 42 9 ENTRETIEN R PARATION D PANNAGE 43 9 1 Entretien et r paration ea 43 9 2 DE DANN AGS eege 43 10 ACCESSOIRES res aient tente auaieants 10 1 Pi ces de rechange 11 TRANSPORT STOCKAGE LIMINATION mms 44 31 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X A propos de ce manuel 1 PROPOS DE CE MANUEL Ce manuel d crit le cycle de vie complet de l appareil Conservez ce manuel de sorte qu il soit accessible a tout utilisateur et a disposition de tout nouveau propri taire Les instructions de service contiennent des informations importantes sur la s curit Le non respect de ces consignes peut entra ner des situations dangereuses Les instructions de service doivent tre lues et comprises Lisez attentivement les instructions de service avant d utiliser l appareil F
21. 0 A 153742 11 TRANSPORT STOCKAGE ELIMINATION REMARQUE Dommages dus au transport Les appareils insuffisamment prot g s peuvent tre endommag s pendant le transport Transportez l appareil l abri de l humidit et des impuret s et dans un emballage r sistant aux chocs vitez le d passement vers le haut ou le bas de la temp rature de stockage admissible Un mauvais stockage peut endommager l appareil Stockez l appareil au sec et l abri des poussi res Temp rature de stockage 40 60 C Dommages l environnement caus s par des pi ces d ap pareil contamin es par des fluides Eliminez l appareil et l emballage dans le respect de l environ nement Respectez les prescriptions en mati re d limination des d chets et de protection de l environnement en vigueur MAN 1000010145 ML Version O Status RL released freigegeben printed 20 01 2015 burkert FLUID CONTROL SYSTEMS www burkert com MAN 1000010145 ML Version O Status RL released freigegeben printed 20 01 2015
22. 4 2 Garantie l gale La condition pour b n ficier de la garantie est l utilisation conforme de l appareil dans le respect des conditions d utilisation sp cifi e 4 3 Informations sur Internet Vous trouverez les instructions de service et la fiche technique sur Internet l adresse www buerkert fr 35 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Conditions d emploi des appareils 5 CONDITIONS D EMPLOI DES APPAREILS 5 1 Conditions particuli res 5 1 1 Protection contre les courts circuits Un fusible correspondant au courant d actionnement max 3 x ere selon CEI 60127 2 1 ou un disjoncteur de court circuit et thermique d clenchement rapide r glage sur courant de d marrage doit tre mont en amont de chaque aimant e Selon la norme CEI cit e le fusible au valeur de courant le plus faible suffit lorsque les courants valu s de l aimant sont tr s faibles Ce fusible peut tre plac dans l appareil d alimentation s y rattachant ou doit tre branch s par ment en amont La tension de calcul du fusible doit tre gale ou sup rieure la tension nominale indiqu e de l aiment Le pouvoir de coupure de la cartouche doit tre gal ou sup rieur au courant de court circuit suppos au lieu de montage habituelle ment 1500 A Dans les versions PD30 de l lectro aimant la protection contre les courts circuits doit tre assur e par l exploitant e Dans la version PD29 de
23. 53 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com International Die Kontaktadressen finden Sie auf den letzten Seiten der gedruckten Bedienungsanleitung Au erdem im Internet unter www burkert com 4 2 Gew hrleistung Voraussetzung f r die Gew hrleistung ist der bestimmungs gem e Gebrauch des Ger ts unter Beachtung der spezifizierten Einsatzbedingungen 4 3 Informationen im Internet Bedienungsanleitungen und Datenbl tter finden Sie im Internet unter www buerkert de A deutsch 21 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Einsatzbedingungen 5 EINSATZBEDINGUNGEN 5 1 Besondere Bedingungen 5 1 1 Kurzschlussschutz Jedem Magneten muss als Kurzschlussschutz eine seinem Anzugsstrom entsprechende Sicherung max 3 x I nach IEC 60127 2 1 bzw ein Motorschutzschalter mit Kurzschluss und thermischer Schnellaus l sung Einstellung auf Anzugsstrom vorgeschaltet werden Bei sehr kleinen Anzugsstr men des Magneten ist die Sicherung mit dem kleinsten Stromwert nach der genannten IEC Norm aus reichend Diese Sicherung darf im zugeh rigen Versorgungsger t untergebracht sein oder muss separat vorgeschaltet werden Die Sicherungs Bemessungsspannung muss gleich oder gr er als die angegebene Nennspannung des Magneten sein Das Ausschaltverm gen des Sicherungseinsatzes muss gleich oder gr er als der maximal anzunehmende Kurzschl
24. And also on the Internet under www burkert com 4 2 Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions 4 3 Information on the Internet The operating manual and the data sheets can be found on the Internet under www burkert com english 7 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Application Conditions 5 APPLICATION CONDITIONS 5 1 Special conditions 5 1 1 Short circuit protection Each electromagnet shall be provided on the line with a short circuit protection in the form of a fuse designed to meet the magnet starting current max 3 x Nas in accordance with IEC 60127 2 1 ora motor overload trip instantaneous short circuit and thermal release Adjustment to match the pull in current At very low pull in currents of the solenoid the fuse with the lowest current value is adequate according to the stated IEC standard This fuse may be mounted in the associated supply unit or must be connected in series separately The rated voltage of the fuse must be equal to or larger than the quoted nominal voltage of the magnet The switch off capability of the fuse cartridge must be equal to or greater than the maximum theoretical short circuit current at the installation location normally 1500 A In the case of versions PD30 of the solenoid short circuit pro tection must be assured by the operator In the case of version
25. CONTROL SYSTEMS 9 WARTUNG REPARATUR FEHLERBEHEBUNG Wartung und Reparatur GEFAHR Gefahr durch unsachgem e Wartungs Reparatur und Instandhaltungsarbeiten e Die Wartungs und Instandhaltungsarbeiten am Ger t d rfen nur autorisiertes Fachpersonal mit geeignetem Werkzeug durchf hren Reparaturen am Ger t d rfen nur vom Hersteller durchge f hrt werden Bei Repatatur oder Wartungsarbeiten an der Anlage darf das Ventil nicht ge ffnet und die Schutzleiterverbindung nicht getrennt werden 9 2 Fehlerbehebung Stellen Sie bei St rungen sicher dass das Ger t vorschriftm ig installiert wurde der Anschluss ordnungsgem ausgef hrt wurde das Ger t nicht besch digt ist e alle Schrauben fest angezogen sind Spannung und Druck anliegen die Rohrleitungen frei sind 10 ERSATZTEILE VORSICHT Verletzungsgefahr Sachsch den durch falsche Teile Falsches Zubeh r und ungeeignete Ersatzteile k nnen Verletzungen und Sch den am Ger t und dessen Umgebung verursachen Nur Originalzubeh r sowie Originalersatzteile der Firma Burkert verwenden 10 1 Zubeh r Bei Ausf hrung der Ger te mit Klemmenkasten kann in Temperatur klasse T4 die Sicherung des Typs 1058 mit Zulassung PTB 01 ATEX 2064 U eingesetzt werden Sicherung Bestellnummer Typ 1058 0 063 A 153717 0 080 A 153745 0 100 A 153718 0 125 A 153719 0 160 A 153720
26. GENERAL INFORMATION smsen 7 10 1 Spare E 15 4 1 Contact Address 11 TRANSPORT STORAGE DISPOSAL ann 16 4 2 Warranty 4 3 Information on the Internet 5 APPLICATION CONDITIONS mme 8 5 1 Special Conditions eegene EENG 8 6 TECHNICAL DATA SAFE OPERATION 6 1 el sen 6 2 Standards EEN 6 3 Operating Conditions sr mis 6 4 General Technical Data 7 ASSEMBLY AND DISASSEMBLY ramener 12 7 1 Safety instructions anna ans 12 7 2 Installation of Valve semestres 13 71 3 Electrical conne tom issues nn 13 Care Ie 3 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X The Operating Instructions 1 THE OPERATING INSTRUCTIONS The operating instructions describe the entire life cycle of the device Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device The operating instructions contain important safety information Failure to observe these instructions may result in hazardous situa tions The operating instructions must be read and understood Carefully read the operating instructions before using the device In particular observe the chapter entitled Intended Use and General Safety Instructions as well as the chapter entitled Application Conditions 1 1 Symbols In the instructions the following symbols are used to identify important information DANGER Warns of an immediate dange
27. PD29 of the solenoid the fuse is installed in the terminal box of the device an More detailed descriptions are to be found in the section 6 Technical data Safe operation 5 1 2 The solenoid coils Type 77 78 may only be operated with a valve body satisfying the following requirements Operation with associated valve body For the valve body the following materials may be used metal brass aluminium stainless steel or plastics eg polyamide PA 6 GV 5 1 3 Manual operation approximity switch The solenoid armature can be manually operated via the push button The push button may be locked by depressing and turning by 90 As an alternative to manual operation the solenoid can be equipped with a proximity switch The internal code for this version is CF 15 PTB 03 ATEX 1030 X Technical data Safe operation burkert FLUID CONTROL SYSTEMS Model with a terminal box DANGER 5 1 4 Risk of explosion Only permanently laid cables and wiring may be inserted The operator must provide suitable stress relief Wires with an outside diameter of 6 to 13 mm may be used Observe the maximum thermal loading of the cables or wires to be inserted The inserted break off seal must be matched to the diameter of the cable or wire The rated cross section of the cable or wire strands must be at least 0 75 mm and may not exceed 2 5 mm The screws for fixing the co
28. ahr Vor dem L sen von Leitungen und Ventilen den Druck abschalten und die Leitungen entl ften Beim Einbau die Durchflussrichtung beachten Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r druckbeaufschlagte Ger te einhalten deutsch PTB 03 ATEX 1030 X Allgemeine Hinweise burkert FLUID CONTROL SYSTEMS A Explosionsgefahr durch elektrostatische Aufladung Bei pl tzlicher Entladung elektrostatisch aufgeladener Ger te oder Personen besteht im Ex Bereich Explosionsgefahr Durch geeignete Ma nahmen sicherstellen dass es im Ex Bereich zu keinen elektrostatischen Aufladungen kommen kann Ger teoberfl che nur durch leichtes Abwischen mit einem feuchten oder antistatischen Tuch reinigen Allgemeine Gefahrensituationen Zum Schutz vor Verletzungen ist zu beachten Dass die Anlage nicht unbeabsichtigt bet tigt werden kann Am System d rfen keine unerlaubten nderungen vorgenommen werden Arbeiten am System d rfen nur durch fachkundiges und unter wiesenes Personal mit geeignetem Werkzeug ausgef hrt werden Das Ger t darf nur in einwandfreiem Zustand und unter Beachtung der Bedienungsanleitung betrieben werden e F r die Einsatzplanung und den Betrieb m ssen die allgemeinen Regeln der Technik eingehalten werden 4 ALLGEMEINE HINWEISE 4 1 Kontaktadressen Deutschland B rkert Fluid Control Systems Sales Center Chr B rkert Str 13 17 D 746
29. aites particuli rement attention aux chapitres Utilisation conforme et Consignes de s curit fondamentales ainsi que les Conditions d emploi des appareils 1 1 Symboles Les moyens de repr sentation suivants sont utilis s dans le manuel pour identifier les informations importantes DANGER Met en garde contre un danger imminent Le non respect peut entra ner la mort ou de graves blessures AVERTISSEMENT Met en garde contre une situation ventuellement dangereuse Risque de blessures graves voire la mort en cas de non respect ATTENTION Met en garde contre un risque possible Le non respect peut entra ner des blessures l g res ou de moyenne gravit REMARQUE Met en garde contre des dommages mat riels Q Conseils et recommandations importants EES A 4 VW o d fi A AR Renvoie des informations dans ces instructions de service ou dans d autres documentations identifie une op ration que vous devez effectuer PTB O3 ATEX 1030 X Utilisation conforme burkert FLUID CONTROL SYSTEMS 2 UTILISATION CONFORME Lutilisation non conforme peut pr senter des dangers pour les personnes les installations proches et l environnement e L appareil sert exclusivement d lectrovanne pour les fluides auto ris s d apr s la fiche technique et pour l emploi dans un groupe d flagrant IIC cat gorie 2G et classe de temp rature T4
30. burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Device with Il 2G D Ex approval Ger te mit Il 2G D Ex Zulassung Appareils avec mode de protection 2G D Ex Example Beispiel Exemple Coil type 0780 with valve body type 0330 Spule Typ 0780 mit Geh use Typ 0330 Bobine type 0780 avec le corps type 0330 Operating Instructions Bedienungsanleitung Manuel d utilisation MAN 1000010145 ML Version O Status RL released freigegeben printed 20 01 2015 We reserve the right to make technical changes without notice Technische Anderungen vorbehalten Sous res rve de modification techniques 2008 2013 Burkert Werke GmbH Operating Instructions 1309 12_EU ML_00804717 Original DE MAN 1000010145 ML Version O Status RL released freigegeben printed 20 01 2015 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Device with II 2G D Ex certification 1 THE OPERATING INSTRUCTIONS u2ua2e02nunnensneonnunnennennnennnnnnennnnnn 4 7 4 DISASSEMADIY vis ccecassancsnccaceszesesvuacanesvdssesstpusecsnecieesstesseaatiastaatschuadianesd 14 ee SE E et eet ehe Ag 14 2 INTENDED USE eege eege 5 8 1 Safety NSURE aiiis aaaea eiaa 14 me e Geer Eegeregie 9 MAINTENANCE REPAIR TROUBLESHOOTING cm 15 2 Ex ovalen oa Special instructions in explosion risk areas anna 6 9 1 Maintenance and repair sn 15 9 2 Troubleshooting sr 15 3 GENERAL SAFETY INSTRUCTIONS mme 6 10 ACCESSORIES a 16 4
31. dschutzarten 6 4 Allgemeine Technische Daten Die Zusammensetzung des Z ndschutzartenkennzeichens richtet sich 6 4 1 Elektrische Daten nach den Z ndschutzarten der jeweils verwendeten Komponenten se T PTE a it KE Elektromagnet 12 G Ex d e IIC T4 bzw T5 yE mit oder ohne 112 D ExtD A21 IP 65 T135 C bzw Temperaturklanse le Klemmenkasten T100 C Stromart Allstrom Allstrom Elektromagnet mit II 2 G Ex de mb IIC T4 Nennspannung 24 240 V 24 240 V SH Il 2 D Ex tD A21 IP65 T135 C Spannungstoleranz 10 10 10 10 und Sicherun gt Bemessungsstrom 0 085 0 014 A 0 085 0 014 A Elektromagnet Il 2 G Ex d e ia IIC T4 bzw T5 A PET 66 A ohne Klem II 2 D Ex tD A21 IP65 T135 C bzw T100 C diel bball ae eats menkasten mit Anzugsleistung 40 W 40 W Naherungsschalter Grenzleistung im 8 W 3 W Elektromagnet Il 2 G Ex d e ia mb IIC T4 Beharrungszustand mit Hemmen Il 2 D Ex tD A21 IP65 T135 C Max Schalth u 20 min 10 min kasten und fi keit ca Sicherung sowie g e Naherungsschalter 6 4 2 Elektrischer Anschluss Ausf h Ausf hrung Interner rungscode Code PD30 Fest eingebaute Gummischlauch IW xx leitung des Typs HOS RN F3G0 75 A deutsch 25 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Montage und Demontage Ausf h Ausf hrung Interner rungscode Code Klemmenkasten mit Kabelver JAO2 schraubung M20 x 1 5 o
32. edia Ensure the device and packaging are disposed of in an environ mentally sound manner Observe applicable regulations relating to refuse disposal and the environment burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Ger te mit Il 2G D Ex Zulassung 1 BEDIENUNGSANLEITUNG 74 DEMONA JE cninn anaa naa Ti 28 ET eene 18 o INBETRIEBNAHME 28 2 BESIIMMUNGSSEMASSE VERWENDUNG csccssssssssssssssseeess 19 9 WARTUNG REPARATUR FEHLERBEHEBUNG anna 29 2 1 Beschr nkungen ni 19 9 1 Wartung und Reparatur 2 2 EX ZUA SUN Oi ee er 19 9 9 Fehlerbeheb 54 Basonden Hinweise WCBS IR mana mans 20 2 Felhlerbe he bung sssitscessisecrseesesrncsessanccensncdacaiesscsattanriateearaciensinties 3 ALLGEMEINE SICHERHEITSHINWEISE 20 10 ERSATZTEILE u 29 Wa DN EE 29 4 ALLGEMEINE HINWEISE cc sssssssssssssssesssssessssesssssesssseesssseessseesssseesss 11 TRANSPORT LAGERUNG ENTSORGUNG anna 30 4 1 Kontaktadressen 4 2 Gew hrleistung 4 3 Informationen im Internet 5 EINSATZBEDINGUNGEN mm 22 5 1 Besondere Bedingungen nnusnennensennnennennnunnennssnennenanunnenanennenane 22 6 TECHNISCHE DATEN SICHERER BETRIEB 23 6 1 Konformit t 293 6 2 N ten ee rn ne ne en a ut 23 6 3 Betriebsbeding ngen s s 23 6 4 Allgemeine Technische Daten ENEE 25 7 MONTAGE UND DEMONTAGE 7 1 Gicherbetebinwese Se 7 2 nstallation GES TE 7 3 Elektrischer Anschluss
33. ever l ancienne bande PTFE des raccords Des restes ou des morceaux de bande ne doivent pas entrer dans la tuyauterie 8 MISE EN SERVICE AVERTISSEMENT Danger d une utilisation non conforme Une utilisation non conforme peut entra ner des blessures et endommager l appareil et son environnement Avant la mise en service il faut s assurer que le contenu des instructions de service est connu et parfaitement compris par les op rateurs Respectez en particulier les consignes de s curit et l utilisation conforme e l appareil doit tre mis en service uniquement par un personnel suffisamment form Avant la mise en service assurez vous que l appareil a t install de mani re conforme le branchement a t r alis comme il convient l appareil n est pas endommag toutes les vis sont convenablement serr es PTB 03 ATEX 1030 X Entretien r paration d pannage burkert FLUID CONTROL SYSTEMS 9 ENTRETIEN R PARATION D PANNAGE Entretien et r paration DANGER Risques dus des travaux d entretien de r paration et de maintenance non conformes Les travaux d entretien et de maintenance sur l appareil doivent tre effectu s uniquement par un personnel qualifi et habilit disposant de l outillage appropri Les travaux de r paration sur l appareil doivent tre effec tu s uniquement par le fabricant Lors des travaux de r paration o
34. ge thermique maximale es c bles ou des lignes introduits Le joint qui peut s arracher doit tre adapt au diam tre du cable de la ligne La section de r f rence des conducteurs du c ble de la ligne doit mesurer au moins 0 75 mm et ne doit pas d passer 2 5 mm Les vis pour fixer le couvercle de la bo te de connexions doivent tre serr es un couple de 1 Nm 5 Les bobines magn tiques peuvent tre aussi r alis es avec une bo te de connexions au choix avec ou sans fusible fusible conforme au certificat d essai de type s par Comme protection contre toute ouverture involontaire du couvercle ce dernier porte l inscription n ouvrir qu en absence de tension 6 CARACT RISTIQUES TECHNIQUES FONCTIONNEMENT EN TOUTE S CURIT 6 1 Conformit Les bobines magn tiques des type 0770 0780 est conforme aux directives CE sur la base de la d claration de conformit CE 6 2 Normes Les normes utilis es avec lesquelles la conformit avec les directives CE sont prouv es figurent dans l attestation CE de type et ou la d claration de conformit CE 6 3 Conditions d exploitation AVERTISSEMENT Risque d explosion Le non respect des caract ristiques techniques vis es sur la plaque signal tique induit des risques graves Toujours respecter les caract ristiques techniques figurant sur la plaque signal tique 6 3 1 Plage de temp rature de service Tenir c
35. hne Sicherung Klemmenkasten mit Gewindenippel JA08 M20 x 1 5 ohne Sicherung PD30 Klemmenkasten mit Gewindenippel JAO9 NPT 1 2 ohne Sicherung Klemmenkasten mit Gewindenippel G JA10 1 2 ohne Sicherung Klemmenkasten mit Kabelver JAO1 schraubung M20 x 1 5 und Sicherung Klemmenkasten mit Gewindenippel JA05 M20 x 1 5 und Sicherung PD29 Klemmenkasten mit Gewindenippel JA06 NPT 1 2 und Sicherung Klemmenkasten mit Gewindenippel G JA07 1 2 und Sicherung Die Anschlussleitung des Elektromagneten Typ 07xx muss fest und so verlegt werden dass sie vor mechanischen Besch digungen hinreichend gesch tzt ist Kabelverschraubung nach getrennter Baumusterpr fbescheinigung 7 Sicherung PD29 nach getrennter Baumusterpr fbescheinigung 7 Unterschiedliche Kabellangen deutsch 7 MONTAGE UND DEMONTAGE 7 1 Sicherheitshinweise GEFAHR Explosionsgefahr Das Ger t ist ein geschlossenes System Es darf nicht demontiert werden Folgende Sicherheitsfestlegungen sind einzuhalten Die Oberfl che des Ger ts kann sich elektrostatisch aufladen In explosionsgef hrdeten Bereichen darf die Oberfl che der Ger te nur mit einem feuchten oder antistatischen Tuch gereinigt werden Nur festgelegte Kabel und Leitungen d rfen eingef hrt werden Der Betreiber muss eine entsprechende Zugentlastung gew hrleisten Leitungen mit AuBendurchmesser von 6 mm 13 mm k nnen verwendet werden Die maximale thermische Belastu
36. l box with threaded nipple NPT JA06 1 2 and fuse Terminal box with threaded nipple G 1 2 JA07 and fuse At Cable bushing to separate Design Inspection Certificate The connecting cable of solenoid Type 07xx must be laid permanently such that it is adequately protected from mechanical damage Fuse protection PD29 to separate type approval test certificate Different cable lengths 7 ASSEMBLY AND DISASSEMBLY 7 1 Safety Instructions DANGER Danger of explosion The device is a sealed system The unit must not be dismantled The following safety regulations must be observed The surface of the device may develop an electrostatic charge In areas with an explosion hazard the surface of the units may only be cleaned with a damp cloth Only permanently laid cables and wiring may be inserted The operator must provide suitable stress relief Wires with an outside diameter of 6 to 13 mm may be used Observe the maximum thermal loading of the cables or wires to be inserted The inserted break off seal must be matched to the diameter of the cable or wire The rated cross section of the cable or wire strands must be at least 0 75 mm and may not exceed 2 5 mm The screws for fixing the cover of the terminal box must be tight ened with a torque of 1 Nm 5 The connection nut clamping nut of the cable gland on the ter minal box must be tightened with a torque of 1 5 Nm 5
37. la surface de l appareil uniquement en l essuyant l g rement avec un chiffon humide ou antistatique Vous trouverez d autres conditions particuli res au chapitre 5 1 de ce manuel d utilisation 3 CONSIGNES DE S CURIT FONDAMENTALES Ces consignes de s curit ne tiennent pas compte des hasards et des v nements pouvant survenir lors du montage de l exploitation et de l entretien des appareils des prescriptions de s curit locales que l exploitant est tenu de faire respecter par le personnel charg du montage EE Risque d explosion La soupape languette fait partie d un syst me ferm et ne peut pas tre d mont e pendant l exploitation Danger par tension lectrique Risque de blessure grave en raison d une tension corporelle dangereuse Avant de commencer une intervention couper la tension et assurer une protection contre la remise en marche de l appareil Respecter les r gles de pr vention des accidents et de s curit en vigueur pour les appareils lectriques Danger d la haute pression Il y a risque important de blessures lors d interventions sur le syst me Couper d abord la pression puis d tacher les c bles et les vannes Respecter les r gles de pr vention des accidents et de s curit en vigueur pour les appareils pneumatiques PTB 03 ATEX 1030 X Indications g n rales burkert FLUID CONTROL SYSTEMS A Risque d explosion d
38. lation m The proximity switch which can be optionally incorporated in all versions is executed in ignition protection type intrinsic safety ia The composition of the ignition protection code follows the igni tion protection types of the components used in each case Correct transportation correct storage and installation and careful use and maintenance are essential for reliable and problem free operation Any other use is considered improper use B rkert is not liable for any resulting damage The user alone bears the risk Use the device only as intended 2 1 Restrictions If exporting the device observe any existing restrictions 2 2 Ex Approval The Ex approval is only valid if you use the modules and components authorised by Biirkets in such a way as described in this operating manual The coil type 0770 0780 may only be used in combination with addi tional components that have been approved by B rkert Otherwise the Ex approval will expire If you make any unauthorized changes to the device the modules or the components the Ex approval will also expire The EC Qualification Test Certificate PTB 03 ATEX 1030 X and the IECEx Certificate of Conformity IECEx PTB 05 0026X has been drawn up by the PTB Physikalisch Technische Bundesanstalt Bundesallee 100 38116 Braunschweig who also audited the manufacture CE0102 The EC type approval test certificate can be found on the Internet at www
39. lines are free 10 ACCESSORIES CAUTION Risk of injury and or damage by the use of incorrect parts Incorrect accessories and unsuitable parts may cause injuries and damage the device and the surrounding area Use only original accessories and original spare supplied by B rkert 10 1 Spare parts For electromagnet models with terminal boxes fuses of the Type 1058 with approval PTB 01 ATEX 2064 U can be used in Temperature Class T4 Fuse Order Type 1058 No 0 063 A 153717 0 080 A 153745 0 100 A 153718 0 125 A 153719 0 160 A 153720 0 200 A 153731 0 315 A 153733 0 400 A 153734 0 500 A 153735 0 630 A 153736 0 800 A 153737 english 15 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030X Transport Storage Disposal Fuse Order Type 1058 No 1 000 A 153738 1 250A 153739 1 600A 153746 2 000 A 153740 3 150A 153742 11 TRANSPORT STORAGE DISPOSAL NOTE Transport damages Inadequately protected equipment may be damaged during transport e During transportation protect the device against wet and dirt in shock resistant packaging Avoid exceeding or dropping below the allowable storage temperature Incorrect storage may damage the device Store the device in a dry and dust free location e Storage temperature 40 60 C Damage to the environment caused by device components contaminated with m
40. ng der eingef hrten Kabel bzw Leitungen beachten e Die eingelegte ausbrechbare Dichtung muss dem Durchmesser des Kabels Leitung angepasst werden Der Bemessungsquerschnitt der Kabel Leitungsadern muss min destens 0 75 mm betragen und darf 2 5 mm nicht berschreiten Die Schrauben zur Befestigung des Deckels des Klemmenkas tens m ssen mit einem Anziehdrehmoment von 1 Nm 5 angezogen werden Die berwurfmutter Druckschraube der Kabelverschraubung am Klemmenkasten muss mit einem Anzugsdrehmoment von 1 5 Nm 5 angezogen werden PTB O3 ATEX 1030 X Montage und Demontage burkert FLUID CONTROL SYSTEMS GEFAHR Gefahr durch elektrische Spannung Akute Verletzungsgefahr durch gef hrliche Korperspannung Gefahr der Besch digung des Ger tes durch Kurzschluss Vor Eingriffen in das Ger t oder die Anlage Spannung abschal ten und vor Wiedereinschalten sichern Spannungsf hrende Klemmen im Klemmenkasten k nnen Strom schlag Kurzschluss oder Explosion verursachen Spannung abschalten Erst dann den Klemmkasten ffnen Die Anschlussleitungen der Elektromagneten m ssen fest und so verlegt werden dass sie vor mechanischen Besch digungen hinreichend gesch tzt sind Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten WARNUNG Gefahr durch hohen Druck Bei Eingriffen in das System besteht akute Verletzungsgefahr V
41. ompte pour chaque type de la plage de temp rature de service figurant dans les conditions d emploi des appareils Version Plage de temp rature ambiante maximale admissible O7xx 30 C 55 C 37 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Caract ristiques techniques fonctionnement en toute s curit 6 3 2 Mode de protection IP65 selon EN 60529 DIN VDE 0470 partie 1 6 3 3 Emplacement et la description de la plaque signal tique Mise en garde Plaque signal tique bobine Plaque signal tique IEC Ex IEC Ex PTB 05 0026X 2 N d homologation IEC Ex Fusible Fuse A Ex d e IIC T5 Ex tD A21 IP65 T100 C Type de protection classe de temp rature Fig 1 Emplacement de la plaque signal tique Type de protection Classe de temp rature N de s rie de la bobine Organisme de surveillance Tension 10 Type de courant Puissance Type et version N d homologation 7 PTB 03 ATEX 1030X eG Ex de ICTs II2D Ex tO Al IP65 IOC 780 PD30 L 220 240V AC DC40 3W S N 6917 CU 10e amp 00627696 MAMA N ID de la bobine Date fabricant urkert 53 Ingelfingen Fig 2 Description de la plaque signal tique 6 3 4 Dimensions Mode de Longueur Largeur Hauteur raccordement mm mm mm C ble serti 96 32 56 Bo te bornes 123 60 113 avec sans fusible
42. or dem L sen von Leitungen und Ventilen den Druck abschalten und die Leitungen entl ften Beim Einbau die Durchflussrichtung beachten Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r druckbeaufschlagte Ger te einhalten 7 2 Installation des Ventils Die Einbaulage des Magnetventils ist beliebig Vorzugsweise mit Magnetsystem oben Vorgehensweise Rohrleitungen reinigen gt Schmutzf nger vorschalten gt Anschl sse der Rohrleitung mit PTFE Band abdichten Rohrleitungen einschrauben Q Durchflussrichtung beachten Ventil auf Dichtheit pr fen 7 3 Elektrischer Anschluss GEFAHR Verletzungsgefahr durch Stromschlag Vor Eingriffen in das System die elektrische Spannung abschal ten und vor Wiedereinschalten sichern Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten Bei fehlendem Schutzleiterkontakt zwischen Spule und Geh use besteht die Gefahr des Stromschlags e Schutzleiter immer anschlie en e Elektrischer Durchgang zwischen Spule und Geh use pr fen A deutsch 27 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Inbetriebnahme Das Anschlusskabel ist mit der Spule vergossen und kann nicht demontiert werden gt Elektrischer Anschluss anbringen 7 4 Demontage GEFAHR Gefahr durch elektrische Spannung Bei Eingriffen in die Anlage besteht akute Verletzungsgefahr
43. ou T5 voir indications sur la plaque d homologation L appareil doit tre utilis uniquement en cat gorie 2D aux tem p ratures T135 C resp 100 C ainsi que dans les cas pr vus au chapitre 5 Conditions d emploi des appareils et en association avec des appareils et composants d autres marques recommand s et homologu s par B rkert Les types de protection l allumage utilis s sont le coffret blind antid flagrant d avec s curit accrue e La s curit instal l e dans la version PD29 est du type de protection l allumage par encapsulage m Le d tecteur de proximit pouvant tre mont en option sur toutes les versions est du type de protection l allumage s curit intrins que ia L identification du type de protection l allumage est bas e sur les types de protection l allumage des composants utilis s Les conditions pour l utilisation s re et parfaite sont un transport un stockage et une installation dans les r gles ainsi qu une utilisation et maintenance parfaites Toute autre utilisation ou toute utilisation allant au del est consid r e comme non conforme B rkert d cline toute responsabilit pour les dommages qui en r sultent L utilisateur est seul en supporter le risque Veillez ce que l utilisation de l appareil soit toujours conforme 2 1 Limitations Lors de l exportation du syst me de l appareil veuillez respecter
44. ous risk of injury when reaching into the equipment e Before loosening the lines and valves turn off the pressure and vent the lines Observe the currently valid accident prevention and safety regulations PTB 03 ATEX 1030 X General Information burkert FLUID CONTROL SYSTEMS A Danger of explosion caused by electrostatic charge If there is a sudden discharge from electrostatically charged devices or persons there is a danger of explosion in the Ex area Take appropriate measures to prevent electrostatic charges in the Ex area Clean the device surface by gently wiping it with a damp or antistatic cloth General hazardous situations To prevent injury ensure that That the system cannot be activated unintentionally That no unauthorized changes are performed on the system Only expert and instructed personnel with appropriate tools carry out any work on the system The device may be operated only when in perfect condition and in consideration of the operating instructions The general rules of technology apply to application planning and operation 4 GENERAL INFORMATION 4 1 Contact Address Germany B rkert Fluid Control Systems Sales Center Chr B rkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com International Contact addresses can be found on the final pages of the printed operating instructions
45. r Failure to observe the warning may result in a fatal or serious injury WARNING Warns of a potentially dangerous situation Failure to observe the warning may result in serious injuries or death CAUTION Warns of a possible danger Failure to observe the warning may result in moderately serious or minor injuries NOTE Warns of damage to property Q Important tips and recommendations an Refers to information in these operating instructions or in other documentation designates a procedure which you must carry out PTB 03 ATEX 1030 X Intended Use burkert FLUID CONTROL SYSTEMS 2 INTENDED USE Incorrect use may be a hazard to people nearby equipment and the environment The device serves exclusively as a solenoid valve for the media stated in the data sheet and for use in Explosion Group IIC Category 2G and Temperature Class T4 or T5 see data on the Ex approval plate The device may be used only in category 2D with the temperatures T135 C and or 100 C as well as for the designated application cases specified in chapter 5 Application Conditions and in con junction with third party devices and components recommended and authorized by B rkert The applied ignition protection types are the pressure resistant casing d with increased safety e The safety fuse incorpo rated in version PD29 is executed in ignition protection type encapsu
46. r jeden Typ den unter Einsatzbedingungen der Spule angegeben maximal zul ssigen Umgebungstemperaturbereich Ausf hrung Maximal zul ssiger Umgebungstemperaturbereich O7xx 30 C 55 C A deutsch 23 burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Technische Daten Sicherer Betrieb 6 3 2 Schutzart IP65 nach EN 60529 DIN VDE 0470 Teil 1 6 3 3 Lage und Beschreibung des Typschildes A Sicherungswert Fuse Warnhinweis Typschild Spule Typschild IEC Ex IEC Ex PTB 05 0026X PERDAR Exd e IIC T5 Ex tD A21 IP65 T100 C Schutzart Temperaturklasse IEC EX Zulassungsnummer Bild 1 Lage des Typschildes deutsch Typ und Ausf hrung Schutzart Temperaturklasse PTB PTB 03 ATEX 1030X I26 ExXdeIICTS II2D Ex tO Al IP65 UTC 780 PD30 220 240V AC DC40 3W S N 6917 C 0102 00627696 Vi burkert D 74653 Ingelfingen Identnummer der Spule Herstellerdatum Seriennummer der Spule berwachungsstelle Spannung 10 Stromart Leistung Bild 2 Beschreibung des Typschildes 6 3 4 Abmessungen Anschlussart L nge Breite H he mm mm mm Eingepresstes 96 32 56 Kabel Klemmenkasten 123 60 113 mit ohne Sicherung PTB 03 ATEX 1030 X RES Technische Daten Sicherer Betrieb burkert 6 3 5 Z n
47. t respecter les prescriptions de s curit suivantes La surface de l appareil peut emmagasiner une charge lectros tatique Dans les zones risques de d flagration la surface des appareils ne doit tre nettoy e qu avec un linge humide Uniquement des c bles et des lignes d termin s doivent tre introduits L exploitant doit assurer une d charge de traction correspondante Des lignes ayant un diam tre ext rieur de 6 mm 13 mm peuvent tre utilis es Tenir compte de la charge thermique maximale es c bles ou des lignes introduits Le joint qui peut s arracher doit tre adapt au diam tre du c ble de la ligne La section de r f rence des conducteurs du c ble de la ligne doit mesurer au moins 0 75 mm et ne doit pas d passer 2 5 mm2 Les vis pour fixer le couvercle de la bo te de connexions doivent tre serr es un couple de 1 Nm 5 L amp crou raccord vis de pression du passe c bles sur le coffret bornes doit tre serr un couple de 1 5 Nm 5 PTB 03 ATEX 1030 X Montage et D montage burkert FLUID CONTROL SYSTEMS DANGER Danger par tension lectrique Risque de blessure grave en raison d une tension corporelle dangereuse Les bornes conductrices de tension de la bo te de bornes peuvent causer des d charges lectriques des courts circuits ou des explosions Il convient de toujours couper la tension avant d ouvrir la bo te de
48. u d entretien sur l installation la vanne ne doit pas tre ouverte et le contact avec le conducteur de protection ne doit pas tre interrompu 9 2 D pannage En cas de d rangement assurez vous que l appareil a t install dans les r gles le raccordement a t correctement effectu l appareil n est pas endommag toutes les vis sont bien serr es la tension et la pression sont disponibles les tuyauteries ne sont pas obstru es 10 ACCESSOIRES ATTENTION Risque de blessures de dommages mat riels dus des mauvaises pi ces Les mauvais accessoires peuvent causer des blessures et endom mager l appareil et son environnement Utilisez uniquement des accessoires d origine de la soci t Burkert 10 1 Pi ces de rechange Dans la version des lectro aimants avec bo te de bornes le fusible de type 1058 avec homologation PTB 01 ATEX 2064 U peut tre utilis en classe de temp rature T4 Type de fusible N 1058 de commande 0 063 A 153717 0 080 A 153745 0 100 A 153718 0 125 A 153719 0 160 A 153720 0 200 A 153731 0 315 A 153733 0 400 A 153734 0 500 A 153735 43 burkert FLUID CONTROL SYSTEMS PTB O3 ATEX 1030 X Transport Stockage Elimination Type de fusible N 1058 de commande 0 630 A 153736 0 800 A 153737 1 000 A 153738 1 250A 153739 1 600 A 153746 2 000 A 153740 3 15
49. ussstrom am Einbauort blicherweise 1500 A sein Bei der Ausf hrung PD30 des Elektromagneten muss der Kurz schlussschutz durch den Betreiber gew hrleistet werden Bei Ausf hrung PD29 des Elektromagneten ist die Sicherung im Klemmkasten des Ger ts eingebaut CA N here Beschreibung der Ausf hrungen finden Sie im Kapitel 6 Technische Daten Sicherer Betrieb deutsch Sicherung A 5 1 2 Betrieb nur mit zugeh rigem Ventil Die Magnetspulen Typ 77 78 d rfen nur mit zugeh rigem Ventil k rper betrieben werden Als Ventilk rper k nnen folgende Werkstoffe verwendet werden Metall Messing Aluminium Edelstahl Kunststoff z B Polyamid PA 6 GV 5 1 3 Handbet tigung N herungsschalter Der Magnetanker kann ber den Tastknopf manuell bet tigt werden Durch Eindr cken und Verdrehen um 90 wird der Tastknopf arretiert Alternativ zur Handbet tigung kann der Elektromagnet mit einem N herungsschalter ausger stet werden Der interne Code f r diese Ausf hrung ist CF 15 PTB O3 ATEX 1030 X Technische Daten Sicherer Betrieb burkert FLUID CONTROL SYSTEMS 5 1 4 Ausf hrung mit einem Klemmenkasten A GEFAHR Explosionsgefahr Nur festgelegte Kabel und Leitungen d rfen eingef hrt werden Der Betreiber muss eine entsprechende Zugentlastung gew hrleisten Es k nnen Leitungen mit Au endurchmesser von 6 mm bis 13 mm verwendet werden Die
50. ver of the terminal box must be tight ened with a torque of 1 Nm 5 The solenoid coils may also be executed with a terminal box with or without fuse contactor to separate Design Type Inspection Cer tificate as desired For protection against inadvertent opening of the cover the latter bears the marking Open only when the voltage is switched off 6 TECHNICAL DATA SAFE OPERATION 6 1 Conformity The coil type 0770 0780 is compliant with the EC Directives according to the EC Declaration of Conformity 6 2 Standards Refer to the EC type approval test certificate and or the EC Declaration of conformity for the applicable standards verifying conformity with the EC directives 6 3 Operating Conditions DANGER Risk of explosion by excedance technical data Exceeding the technical data indicated on the type label increases the explosion risk Never exceed the technical data indicated on the type label 6 3 1 Maximum permissible ambient temperature range Please observe the maximum permissible ambient temperature range given under Operating conditions of the coils for each type Version Maximum permissible ambient temperature range O7xx 30 C 55 C english burkert FLUID CONTROL SYSTEMS PTB 03 ATEX 1030 X Technical data Safe operation 6 3 2 Type of protection IP65 to EN 60529 DIN VDE 0470 Part 1 6 3 3 Location and description of the type label
51. wichtige Zusatzinformationen Tipps und Empfehlungen an Verweist auf Informationen in dieser Bedienungsanleitung oder in anderen Dokumentationen gt markiert einen Arbeitsschritt den Sie ausf hren m ssen PTB O3 ATEX 1030 X Bestimmungsgem e Verwendung burkert FLUID CONTROL SYSTEMS 2 BESTIMMUNGSGEMASSE VERWENDUNG Bei nicht bestimmungsgem em Einsatz k nnen Gefahren f r Personen Anlagen in der Umgebung und die Umwelt entstehen Das Ger t dient ausschlie lich als Magnetventil f r die laut Daten blatt zul ssigen Medien und f r den Einsatz in Explosionsgruppe IIC Kategorie 2G und Temperaturklasse T4 oder T5 siehe Anga ben auf dem X Zulassungsschild e Das Ger t darf nur f r den Einsatz in Kategorie 2D mit den Tem peraturen T135 C bzw 100 C sowie f r die im Kapitel 5 Ein satzbedingungen vorgesehenen Einsatzf llen und in Verbindung mit von B rkert empfohlenen bzw zugelassenen Fremdger ten und komponenten verwendet werden Die angewendeten Z ndschutzarten sind die Druckfeste Kap selung d mit Erh hter Sicherheit e Die Sicherung die bei Ausf hrung PD29 eingebaut ist ist in Z ndschutzart Vergusskap selung m ausgef hrt Der N herungsschalter der optional bei allen Ausf hrungen eingebaut werden kann ist in Z ndschutzart Eigensicherheit ia ausgef hrt Die Zusammensetzung des Z nd schutzartenkennzeichens richtet sich nach den Z