Home

CFOx61/x91/432 video links User manual

image

Contents

1. admin CRT861 Ethauto command Use the ethauto command to enable disable auto negotiation feature of network interface Entering help ethauto displays a list of options for ethauto command admin CRT861 help ethauto Usage ethauto PORT on off Display or enable disable auto negotiation on a network interface PORT Defines the network interface 1 Mgmt Ethernet 2 Bridge Ethernet onloff Enable or disable the auto negotiation admin CRT861 Ethduplex command Use the ethduplex command to set network interface to half or full duplex mode Entering help ethduplex displays a list of options for ethduplex command Note Ethauto command must be disabled before using the ethdu plex command If the ethauto command is enabled ethduplex command doesn t have an effect 21 admin CRT861 help ethduplex Usage ethduplex PORT half full Display or set the duplex on a network interface PORT Defines the network interface 1 Mgmt Ethernet 2 Bridge Ethernet half full Set the duplex on the interface admin CRT861 CFOx61 x91 CFO432 user manual Ethspeed command Use the ethspeed command to set network interface speed to 10 or 100 Mbps Entering help ethspeed displays a list of options for eth speed command Note Ethauto command must be disabled before using the eth speed command If the ethauto command is enabled ethspeed com
2. Ethernet bridge interface s indicator operation 9 CFOx61 x91 CFO432 user manual Video Source Alarm VSA The CCL output channel can be alternatively configured for Video Source Alarm VSA monitoring Instead of normal CCL use the CCL output can be used to provide a VSA signal if a loss of video signal occurs When VSA mode is enabled at transmitter and if video signal is missing e g a camera malfunction link otherwise operates normally the CCL output pins are closed Using VSA at just one end of the link enables the opposite path to be used for standard CCL operation simplex In case when VSA is enabled both at transmitter and receiver the CCL channel is no longer available for any other use When VSA is disabled the CCL channel is available for normal use in both directions The VSA mode can be set on off via management connection See page 28 for more information how to configure VSA operation Note Enabling VSA on any channel overrides normal contact closure functionality Led Colour Status i Green blinking Video OK Yellow blinking Video missing VSA active CCL indicator operation when VSA is enabled Link Source Alarm LSA The CCL output channel can be alternatively configured for Link Source Alarm LSA monitoring Instead of normal CCL use the CCL output can be used to provide a LSA signal if a loss of optic link occurs When LSA mode is enabled at transmitter and if optical communicatio
3. confget 10 9 96 1 dconfig tar gz Gets dconfig tar gz named configu ration from address 10 9 96 1 admin CRT861 help confget Usage confget SERVER IP FILENAME Get configuration from a tftp server NOTE This may affect on IP settings SERVER IP IP address of the tftp server FILENAME Name of the target file Defaults to dconfig tar gz admin CRT861 CFOx61 x91 CFO432 user manual 19 Confput command Use the confput command to upload the current configuration to a TFTP server Entering help confput displays a list of options for confput command Note TFTP server must be installed configured correctly and activated before using confput command See page 29 Example confput 10 9 96 1 dconfig tar gz Puts dconfig tar gz named configuration to address 10 9 96 1 admin CRT861 help confput Usage confput vdac eth all SERVER IP FILENAME Upload configuration to a tftp server NOTE Passwords and hostname will not be stored vdac Store video data channel audio and contact closure settings eth Store Ethernet and IP address settings all Store all settings SERVER IP IP address of the tftp server FILENAME Name of the target file Defaults to dconfig tar gz admin CRT861 Data command Use the data command to enable disable data channel Entering help data displays a list of options for data command
4. As with all CFO Platform products the units meet all standard EMC and environmental requirements All units are fully compatible with all CFO rack systems Stand alone options are available with the CMA module adapter and a separate mains adapter CFOx61 x91 CFO432 user manual Video Link Front Panel eq TELESTE OPTICAL TRANSMITTER g 0 A gt 0 95 2 j i i 3 a gt a Gina ta O voue i EN SHA E 6 NEL e An exampe view of 8 channel video modem CRT861 Except video channels this information is applicable to 1 channel and 4 channel units as well including CRR receivers 1 DATA 1 amp CCL connector RJ 45 female 2 DATA 2 amp 3 connector RJ 45 female 3 AUDIO 1 amp 2 connector RJ 45 female 4 Management connector RJ 45 female 5 Optical input output singelmode SC APC 8 multimode SC PC or LC UPC 6 Handle with unit information 7 Locking screw 4 pcs 8 Video input BNC female and video indicator led 9 ETHERNET BRIDGE connector RJ 45 female See further information on dedicated sections CAUTION CFO161 191 461 491 861 891 432 OPTICAL UNITS USES CLASS 1M LASER DIODE DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS APPLICABLE STANDARD IEC60825 1 2001 Frame installation The CFO unit is to be pushed along the guide rails into the installa
5. Example data 1 on Enables data channel 1 admin CRT861 help data Usage data PORT all on off Display or enable disable a data channel PORT all Defines the number of the data channel onloff Enable or disable the data channel admin CRT861 Databias command Use the databias command to change device data bias settings Entering help databias displays a list of options for databias command admin CRT861 help databias Usage databias port onloff Display or enable disable biasing on a data channel NOTE Termination is not effective while bias is disabled port Defines the number of the data channel on off Enable or disable biasing on the data channel admin CRT861 CFOx61 x91 CFO432 user manual Datadwell command Use the datadwell command to change device data port dwell time settings Entering help datadwell displays a list of options for datadwell command Valid only when selected data format is 2 wire RS 485 Unit in microseconds available 0 65 535us Example datadwell 1 50 Sets 50us dwelltime to data channel 1 20 admin CRT861 help datadwell Usage datadwell PORT DWELLTIME Display or set dwelltime on a sampled data channel PORT Defines the number of the data channel DWELLTIME Dwelltime in microseconds Valid range is 0 65535 admin CRT861 Dataterm command Use the dataterm command to change devi
6. On the receiving end the minimum optical input level is typically 23 dBm Please note that due to different optical windows the maximum link budget in terms of kilometers is different on forward video and return paths The output level of CFO432 modems is typically 7 dBm However the optical levels have less significance when dealing with digital high speed data propagation in multimode fibre Typically the distance limitations are set by the cable type OM class fibre bandwidth vs wavelenght etc When testing a CFO link over a short fiber patch cable it is advised to use an additional optical attenuator to guarantee system safe operation Typically the maximum allowed input level for bi directional links is O dBm In most cases a suitable attenuator value for testing is 5 dB Please check also that attenuators are high quality doped fibre type with an excellent reflection loss value air gap attenuators may cause difficulties on link association due to poor reflection loss performance CFOx61 x91 CFO432 user manual Command Line Interface CLI General The CFO unit includes a command line interface CLI for configuration purposes CLI is accessed through any terminal program e g Hyper Terminal or Telnet over serial data or TCP IP connection The com mand structure is the same for both session types System requirements for CLI PC equipped terminal emulation program RS232 cable or any CAT5 Ethernet cable direct or cr
7. CRT861 Ipcfg command Use the ipcfg command to change device IP settings Entering help ipcfg displays a list of options for ipefg command Note Changing the IP address over TCP IP connection will terminate the communication A new connection must be created over a serial connection or with new IP address admin CRT861 help ipcfg Usage ipcfg IP ADDRESS NETMASK GATEWAY Display or change the ip settings IP ADDRESS IP address in dotted notation NETMASK Subnet mask GATEWAY Default gateway admin CRT861 Lsa command Use the Isa command to enable disable LSA monitoring on the device Entering help Isa displays a list of options for Isa command admin CRT861 help lsa Usage lsa on off Display or enable disable LSA monitoring on the device NOTE Enabling LSA overrides normal contact closure and VSA func tionality on off Enable or disable LSA monitoring admin CRT861 CFOx61 x91 CFO432 user manual Lsadelay command Use the Isadelay command to view or change the devices source alarm switching delay Entering help Isadelay displays a list of options for Isadelay command admin CRT861 help lsadelay Usage lsadelay DELAY Display or set the link source alarm switching delay Delay defines how long the device will wait for the optic link to get up before operating contact closure circuit NOTE Setting delay to 0 will cause contact closure circ
8. Vp p 75 ohm 10 bits 15 55 MHz 6 5 MHz 3 40 ns 2 2 67 dB 3 bi directional RS232 422 485 RS232 0 230 kbps 50 65500 us 2 bi directional 60 5 kHz 16 bits 600 10k ohm 10 ohm 0 dBm 20 dBm 0 02 20 KHz 70 dBqp 1 bi directional dry contact relay 5Hz forward return OM1 62 5 125 um OM2 50 125 um DC component 3 dB max max max unified weighted selectable fixed all channels RS485 2 wire unbalanced balanced selectable 3 dB ref 1 KHz CCIR weighted open close max loop R 120 ohm max 30 V 1A switching max Ethernet Bridge Number of ports Port type Compliant Management Command Line Interface SNMP General Supply voltage Current consumption max Dimensions H x W x D Weight Connectors Video 1 bi directional 10 100Base TX IEEE802 3 IEEE802 3U configurable RS 232 and or TCP IP terminal v2 MIB II remote via network Data audio cc mgmt Ethernet RJ 45 female Optical Operating temperature Storage temperature Humidity EMC compatibility Notes 1 Class 1M operation 10 5 14 V DC regulated 750 mA steady state 3U x 10HP x 190 mm without CMA 0 8 kg BNC female LC UPC 34 74 C 34 74 C 0 95 non condensing EN61000 6 4 EN50130 4 CE FCC CFR 47 Part 15 subpart B class A 2 Transmission distance may be limited by fibre type bandwidth and possible other physical variables on the cable infr
9. be installed for stand alone use by using a CMA025 installation for 10HP wide CFO series units or CMA035 installation for 15HP wide CFO series units module adapter The module should be mounted to a vertical surface The 12V DC supply voltage is supplied by the means of a separate mains adapter with a regulated output e g CPS251 Please refer to separate documention for module adapters and mains adapters Power supply connection CMA025 module adapter with CIK002 rear mounting kit 1 CMA025 module adapter 2 CIK002 rear mounting kit 4 CFOx61 x91 CFO432 user manual 199 VIva Led 1 CCL Led 2 Data 1 Led 3 Data 2 Data connections The CFO link contains three independent bi directional data channels TX lt gt RX The connector is type RJ 45 female Supported data modes for data channel 1 amp 2 are RS232 RS422 RS485 2w and RS485 4w Data channel 3 is fixed for RS232 mode only A recom mended cable for DATA connection is CIC603 RJ 45 open wires 2 meters The desired data mode for data channel 1 amp 2 can be set via management connection see page 13 The default factory settings are data ch1 RS485 2w dwell time 75us and data ch2 RS232 ee 3 Pin S
10. connection adapter CIC505 connection adapter Allowing simultaneous serial and TCP IP connection via MGMT connector Led Status Full duplex Colour Green 1 Green blinking Collisions in data No light Yellow Half duplex Mgmt link up 2 Yellow blinking No light Ethernet mgmt active Mgmt link down Mgmt connection s indicator operation PC PSION D9 female RJ 45 male CFO Receive data 2 8 Mgmt output Transmit data 3 5 Mgmt input System ground 5 Shield Ground Management cable CIC 505 pinout D9 female RJ 45 male CFOx61 x91 CFO432 user manual CCL output CCL input Led 1 CCL lt 4 gt E gt Q AS Q a m Led 2 Data 1 CCL connector CCL led indicates status of CCL input output signal Pin Colour White green stripe Green White orange stripe Blue White blue stripe Orange NIL OO MIRI NM gt White brown stripe 8 Brown CIC603 cable s pinout wire colors RJ 45 male open wires Contact closure loop CCL connection The CFO link contains one bi directional contact closure channel line TX lt gt RX The CCL input is a normal short circuit on off signal between connector s contact pins 4 and 5 max loop resistance approxi mately 120 Q The CCL output is a normal relay on off signal between connector s cont
11. in the permitted range or Red a hardware failure MODULE indicator operation lt _X__ Video is received ok return link is down LINK STATUS SY vink status O YELLOW BLINKING GREEN No reception Status received from TX gt Video is not received ok return link is up DATA CCL DATA DATA CCL DATA AUDIO AUDIO LINK STATUS LINK STATUS BLINKING GREEN YELLOW Status received from TX No reception MGMT MGMT Y 6 VIDEO 4 O X der O LINKSTATUS O LINKSTATUS 3 fa O MODULE z O MODULE m u Z u o lu Video is not received ok both directions AN are down If MODULE is not showing alarm fault is on fibre LINK STATUS LINK STATUS YELLOW YELLOW No reception No reception O ETHERNET BRIDGE O LINK STATUS indicator operation example CFOx61 x91 CFO432 user manual front view AS El The optical connector type for singlemode is SCIAPC CFO1x1 4x1 8x1 The optical connector type for multimode is LC UPC CFO432 Optical Interface In units operating over single mode fibre the optical connector type is SC APC 8 angle polished whereas the units for multimode fibre transmission CFO432 have duplex LC UPC optical connectors Some generic notes f
12. list of commands by using help CFOx61 x91 CFO432 user manual All command Use the all command to enable disable all audio data and video ports on the device Entering help all displays a list of options for all command Example all on Enables all audio data and video ports admin CRT861 help all Usage all on off Enable or disable all audio data and video ports on the device Enable or disable all ports on off admin CRT861 Audio command Use the audio command to enable disable the audio channel Entering help audio displays a list of options for audio command Example audio 1 on Enables audio channel 1 admin CRT861 help audio Usage audio PORT all on off Display or enable disable an audio channel Defines the number of the audio channel Enable or disable the audio channel PORT all onloff admin CRT861 Audiobal command Use the audiobal command to enable disable balanced interface on the audio channel Entering help audiobal displays a list of options for audiobal command Example audiobal 1 on Enables balanced interface for audio channel 1 admin CRT861 help audiobal Usage audiobal PORT onloff Display or enable disable balanced input on an audio channel PORT Defines the number of the audio channel onloff Enable or disable the balanced input admin CRT861 CFOx61 x91 CFO432 us
13. our web site www teleste com CFOx61 x91 CFO432 user manual Notes 33 CFOx61 x91 CFO432 user manual 34 CFOx61 x91 CFO432 user manual TELESTE www teleste com
14. 47 Part 15 subpart B class A Number of channels 2 bi directional unbalanced balanced Sampling frequency 60 5 kHz Notes Sampling resolution 16 bits Class 1M Laser Product Input impedance 600 10k ohm selectable without CMA Output impedance 10 ohm Nominal level 0 dBm Typical values unless otherwise stated Clipping level 20 dBm Frequency response 0 02 20 kHz 3 dB ref 1 kHz S N ratio 70 dBqp CCIR weighted video e one singlemode video x 8 data x 3 gt gt fibre data x 3 De CRT861 CRR861 FRR eth x 1 gt 1519 2 ton eth x 1 mgmt 50 km mgmt one singlemode fibre video x 8 gt data x 3 gt t gt data x 3 i gt audio x 2 ee CRT891 CRR891 u a 1550 1310nm a mgmt 60 km mgmt 30 CFOx61 x91 CFO432 user manual Technical specifications CFO432 Optical Wavelength Range 2 Video Number of channels Standard 1310 nm 1310 nm 1 5 km 2 5 km 4 uni directional CVBS or Y C Input and output signal levels 1 Vp p Input overload level Impedance Sampling Bandwidth C L gain inequality C L delay inequality Differential gain Differential phase S N ratio Data Number of channels Data 1 amp 2 format Data 3 format Data rate Dwelltime setting Audio Number of channels Sampling frequency Sampling resolution Input impedance Output impedance Nominal level Clipping level Frequency response S N ratio Contact Closure Number of channels Input Output Data rate 1 5
15. RT861 help termsize Usage termsize LINES Display or set the terminal window s size Setting zero defaults to 24 lines LINES Define the height of the terminal window admin CRT861 Uptime command Use the uptime command to display the time since the last boot Entering help uptime displays a list of options for uptime command admin CRT861 help uptime Usage uptime Display the time since the last power up and the load averages of past 1 5 and 15 minutes admin CRT861 CFOx61 x91 CFO432 user manual Version command Use the version command to display version and hardware information of the device Entering help version displays a list of options for version command admin CRT861 help version Usage version Display version and hardware information of the device admin CRT861 Video command Use the video command to display or enable disable a video channel Entering help video displays a list of options for video command admin CRT861 help video Usage video PORT all on off Display or enable disable a video channel PORT all Defines the number of the video channel on off Enable or disable the video channel admin CRT861 Vsa command Use the vsa command to VSA monitoring on video channel s Entering help vsa displays a list of options for vsa command admin CRT861 help vsa Usage vsa PORT all on off Displ
16. User manual One four and eight channel video links CFO First Mile series consist of fibre optic modems which provide a high quality and losless video transmission for variety of CCTV applications CFO432 4 channel MM video link CFO161 1 channel SM video link CFO191 1 channel SM video link CFO461 4 channel SM video link CFO491 4 channel SM video link CFO861 8 channel SM video link CFO891 8 channel SM video link 1 DATA CCL DATA 2 3 Q o 3 N amp LINK STATUS de MODULE ETHERNET BRIDGE 310nm Tx 1dBm Rx 21 dBm Video Networks CFOx61 x91 CF0432 user manual 59300288 rev007 Contents Optical Transmitter amp Receiver u naeh id aia 2 Introduction a led eedes 2 Video Link Front Panel 22 ce cecceccee cee cette cece eee EL EL LEE ERE EL EEN 3 Frame Installation siii ia 3 Video connections and indicator leds esserne reen reen ener erne 3 CSX Multiplexer Operation en a ia 3 S Video OPIO it di A ADE AA A AA AAA Aaaa ie 3 Stand alone installation en ea indias 4 Data COMMECIONS iia iO id aii de Kun ern naar Trennen 5 AUdIO COMEeCtON tiara A nee A a 6 Management mgmt data connection 0000 eee cette erent enter er ete cnn rare 7 Contact closure loop CCL Connection ee ic 8 Ethernet Bridge CONNECTION cc etree ett en conan nn c cnn rc rre rene rra 9 Video Source Alarm VSA sun ES DE EDER sen bene 10 Link Source Alarm LS A oncicccnnnnicicnnnnoccccconnconccccn cn
17. act pins 7 and 8 maximum switching 30 V DC V AC 1A The connector type is a RJ 45 female The recommended cable for CCL use is CIC603 RJ 45 open wires The CCL output channel can be alternatively configured for VSA video source alarm or LSA link source alarm usage via management connection see page 10 Pin Signal RS232 RS422 RS485 2w RS485 4w CC1 in 5 Ground CCL VSA LSA out A CCL VSA LSA out B DATA 3 amp CCL connector s pinout Led Colour Status Green CCL output is closed pin 4 to ground Yellow CCL output is open CCL indicator operation CFOx61 x91 CFO432 user manual Led 1 status Ethernet Bridge connection The ETHERNET BRIDGE interface provides one Ethernet 10 100Base Tx port for any IP device requiring Ethernet connectivity The connector type is a RJ 45 female Default port configuration is with autonego tion feature enabled Led 2 mode Ethernet Bridge connector i Note It is also possible to disable ETHERNET BRIDGE via management a 5 Signal Tx Rx Tx Rx Rx Tx Rx Tx D NX O TD B O N Ethernet Bridge connector s pinout Led Colour Status Yellow Link up 1 Yellow blinking Link active and traffic detected No light Link down or disabled Green Full Duplex 2 Green blinking Collision activity No light Half Duplex
18. astructure Typical values unless otherwise stated two multimode fibres CRT432 CRR432 cc x 1 lt gt cc x 1 athe 1310 1310nm ethx 1 mgmt 1 5 km OM1 mgmt 2 0 km OM2 31 CFOx61 x91 CFO432 user manual 32 Copyright acknowledgements Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation Copyright O Teleste Corporation All Rights Reserved No part of this document may be reproduced transmitted stored in a retrieval system or translated into any other language without the express permission of Teleste Corporation Teleste Corporation Video Networks P O Box 323 FIN 20101 Turku FINLAND www teleste com WEEE directive Directive 2002 96 EC of the European Parliament and of the Council on waste electrical and electronic equipment WEEE obliges that producers appropri ately mark electrical and electronic equipment with the symbol indicating separate collection This obligation applies to the equipment put on the market in EU after 13 August 2005 Teleste devices which belong to the scope of the directive have been marked with the separate collection symbol shown below The marking is according to the standard EN 50419 The symbol indicates that the device has to be collected and treated separately from unsorted municipal waste User manual revision history note The latest version is always available in pdf format on
19. ay or enable disable VSA monitoring on video channel s NOTE Enabling VSA on any channel overrides normal contact closure functionality PORT all Defines the number of the video channel on off Enable or disable VSA monitoring admin CRT861 CFOx61 x91 CFO432 user manual Vsahold command Use the vsahold command to display or set the video source alarm holdtime Holdtime defines how long will a missing video signal be tolerated before enabling the alarm Entering help vsahold displays a list of options for vsahold command Holdtime in seconds range 0 4294967295 sec admin CRT861 help vsahold Usage vsahold HOLDTIME Display or set the video source alarm holdtime Holdtime defines how long will a missing video signal be tolerated before enabling the alarm HOLDT IME Holdtime in seconds admin CRT861 TFTP Trivial File Transfer Protocol TFTP is a simple protocol used for updating the software on network devices This server application can be used in the same PC which is used for the CFO management Suitable TFTP application softwares are freely available from verious internet sources CFOx61 x91 CFO432 user manual Technical specifications CFO161 191 461 491 861 891 Optical Contact Closure Wavelength 1310 1310 nm CFOx61 Number of channels 1 bi directional 1550 1310 nm CFOx91 Input dry contact open close max Output power 1 dBm CFOx61 loop R 120 ohm 1 dBm CFOx91 Outp
20. ce data port termination settings Entering help dataterm displays a list of options for dataterm command Required only when several devices are sharing tha same data bus i e line termination admin CRT861 help dataterm Usage dataterm PORT on off Display or enable disable termination on a data channel NOTE Termination is not effective while bias is disabled PORT Defines the number of the data channel on off Enable or disable termination on the data channel admin CRT861 Datatype command Use the datatype command to change device data interface settings Entering help datatype displays a list of options for datatype command admin CRT861 help datatype Usage datatype PORT rs 232 rs 422 rs 485 rs 485 4wire Display or set physical interface type on a data channel NOTE Data channel 3 is fixed to rs 232 PORT Defines the number of the data channel rs TYPE Set physical interface type on the data channel admin CRT861 CFOx61 x91 CFO432 user manual Use the eth command to enable disable device network interface Entering help eth displays a list of options for eth command Example eth 1 on Enables Management Ethernet port admin CRT861 help eth Usage eth PORT on off Display or enable disable a network interface PORT Defines the network interface 1 Mgmt Ethernet 2 Bridge Ethernet on off Enable or disable the network interface
21. er manual 18 Audioimp command Use the audioimp command to set 600 W input impedance to both audio channels 1 amp 2 the default factory setting is 10 kQ This setting requires balanced wiring for both channels Entering help audioimp displays a list of options for audioimp command Example audioimp on Sets 600 Q input impedance to audio channels 1 amp 2 admin CRT861 help audioimp Usage audioimp on off Display or enable disable 600 ohm input impedance on audio channels on off Enable or disable the input impedance admin CRT861 Ccaction command Use the ccaction command to display or set the contact closure action on alarm Entering help ccaction displays a list of options for ccaction command admin CRT861 help ccaction Usage ccaction open close Display or set the contact closure action on alarm NOTE If LSA fires the alarm and LSA delay is greater than 0 the contact closure circuit will not stay in the assigned position but keeps strolling until link up is detected open CC contact is opened on alarm close CC contact is closed on alarm admin CRT861 Confget command Use the confget command to download the stored configuration from a TFTP server Entering help confget displays a list of options for confget command Note TFTP server must be installed configured correctly and activated before using confget command See page 28 Example
22. ice s settings Entering help r displays a list of options for r command admin CRT861 help r Usage r COMMAND PARAMS Execute COMMAND on link partner device Remote commands except status do not work on an uni directional link admin CRT861 Reboot command Use the reboot command to reboot the device Entering help reboot displays a list of options for reboot command admin CRT861 help reboot Usage reboot Reboot the device admin CRT861 CFOx61 x91 CFO432 user manual 26 Status command Use the status command to view device settings Use the status r command to view remote device settings admin CRT861 help status Usage status Display module status information NOTE Exclamation mark next to data channel termination indicates that the termination is ineffective while the channel s bias is disabled admin CRT861 admin CRT861 status UNE so tert kata ent CRIGEL Temperature 48 0C 118 4F Running on Partition 0 Optical link Local rx down Mgmt Ethernet Up Autoneg 100HDX Bridge Ethernet Down Autoneg Video channel 1 Enabled No video Video channel 2 Enabled No video Video channel 3 Enabled No video Video channel 4 Enabled No video Video channel 5 Enabled No video Video channel 6 Enabled No video Video channel 7 Enabled No video Video channel 8 E
23. ignal RS232 RS422 RS485 2w RS485 4w DATA CCL and DATA connectors and Data 1 in in out in indicator LEDs 2 Data1 in in in out in Bin Bcaiser Data 1 out out out 1 White green stripe 2 Green 3 White orange stripe 6 bata ous ous 4 Blue 5 White blue stripe 6 Orange DATA CCL connector s pinout 7 White brown stripe 8 Brown Pin Signal RS232 RS422 RS485 2w RS485 4w ARE i 1 Data 2 in in out in a oo RE 2 Data 2 in in in out in 3 Data 2 out out out Led Colour Status 4 NC Green CCLis on 5 Ground TYeliow CCL is off 6 Data 2 out out Green Channel input active 7 Data 3 in 2 Yellow Channel input passive 8 Data3 out No light Channel disabled DATA connector s pinout Green Channel input active 3 Yellow Channel input passive Data mode Input termination options No light Channel disabled RS232 None Green Channel input active RS422 No term with failsafe 10 kQ line biasing 4 Yellow Channel input passive Line termination 120 Q No light Channel disabled No term with failsafe 10 kQ line biasing DATA CCL and DATA connection s RS485 2w Dwell time adjustable 0 65535us indicator operation Hard bias forced 680 line biasing Line termination 120 Q No term with failsafe 10 kQ line biasing RS485 4w Hard bias forced 680 line biasing Line termination 120 Q Data input termination options for data channels 1 8 2 See CLI description for c
24. ld lsareset passwd r reboot status swupdate termsize uptime version video vsa vsahold admin CRT861 help admin CRT861 Enable or disable all ports Display or enable disable an audio channel Balanced input on an audio channel 600 ohm input impedance on audio channels Contact closure action on alarm Get configuration from a tftp server Upload configuration to a tftp server Display or enable disable a data channel Biasing on a data channel Dwelltime on a sampled data channel Termination on a data channel Physical interface type on a data channel Display or enable disable a network interface Auto negotiation on a network interface Duplex on a network interface The speed on a network interface Log out from command line interface Set factory defaults Display list of commands or usage of a single command Hostname of the device IP settings Display or enable disable link source alarm Link source alarm delay Link source alarm hold time Reset link source alarm to the initial state Change user s password Execute a command on link partner device remote end Reboot the device Display module status information Update software image from a tftp server Size of the terminal window Display the time since the last power up Display version and hardware information of the device Display or enable disable a video channel Display or enable disable video source alarm Sideo source alarm hold time A short
25. mand doesn t have an effect 22 admin CRT861 help ethspeed Usage ethspeed PORT 10 100 Display or set the speed on a network interface PORT Defines the network interface 1 Mgmt Ethernet 2 Bridge Ethernet 101100 Set the speed of the interface admin CRT861 Use the exit command to log out from CLI Entering help exit displays a list of options for exit command admin CRT861 help exit Usage exit Log out from command line interface admin CRT861 Factory command Use the factory command to set factory defaults Entering help factory displays a list of options for factory command admin CRT861 help factory Usage factory Set the factory defaults NOTE This will affect on IP settings admin CRT861 Help command Use the help command to view a list of CLI commands Entering help help displays a list of options for help command Entering help com mand displays options for command admin CRT861 help help Usage help COMMAND Display list of commands or view the usage of given COMMAND admin CRT861 CFOx61 x91 CFO432 user manual Hostname command Use the hostname command to view or change the device hostname Entering help hostname displays a list of options for hostname command admin CRT861 help hostname Usage hostname NAME Display or change the hostname NAME The new hostname admin
26. n is disturbed seriously link fail alarm due to e g a cable break or dam age a laser fail etc the CCL output pins are closed Using LSA at just one end of the link enables the opposite path to be used for standard CCL operation simplex In case when LSA is enabled both at trans mitter and receiver the CCL channel is no longer available for any other use When LSA is disabled the CCL channel is available for normal use in both directions The LSA mode can be set on off via management connection See page 23 for more information how to configure LSA operation For a practical use the LSA CCL operation can be also used to control an optical switch in fibre redundant applications Note Enabling LSA overrides normal contact closure and VSA functionality Led Colour Status 1 Green blinking Link OK Yellow blinking Link missing LSA active CCL indicator operation when LSA is enabled CFOx61 x91 CFO432 user manual Link status and module indicator leds The CFO contains LINK STATUS and MODULE indicators which inform generic status of unit Colour Status Optical signal level is adequate and syncronization on link Green level is achieved Blinking Green Link alarm from remote end No optical signal received Yellow Optical signal is missing or input level is too low LINK STATUS indicator operation Colour Status Green Normal operation Supply voltage is not
27. n cccn naar cnn cnn rre rr r rra nene rr ran SE ATASE RR Ren 10 Eink status and module indicator le ds ceca na in leisen 11 Optical Interface ici tienda iio 12 Optical signal levels A A A 12 Command Line Interface Cl reinen ann anne ernennen 13 General natu A dad iii 13 System requirements for Clica A AAA 13 USE MU a 13 Connection methods Serial CONNECTION 4444444444444n04nHanennnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnennnnnnnnnnnnnnnenn 14 Connection methods TCP IP ceccecececeece eee ee eee eeecceacaaeaeeeeeeceeeececaaaaaeaaeeeeeeeeeeeeesecsaeaaeeeeeeeeeesesecesacieeaeeeeeees 15 Detailed descriptions of commands c ccccccecceceee eee ceeeeee eee ee eee ee ee renere rr ELLE Een ener 16 29 Commands in Diles ado n 16 How to use the CLI commandS aiiiar annat aser RR RR nn nn nn rr a aaa naaa AE iae 16 Technical specifications CFO161 191 461 491 861 891 oooooooocononicicccoccccccccccccconnnanaonnonnnnnnnnnnnncnanan nn n no nnnnnnnnnnnns 30 Technical specifications CFO432 nio ii na a ed ariba 31 Copyright acknowledgements 42522222 ccc tee EIDE IEEE EGE SEDDEL ran nr rr rra DL 32 WEEE directive cios a A teta iaa 32 CFOx61 x91 CFO432 user manual Optical Transmitter amp Receiver Single multimode 1 4 and 8 channel video link for uni directional video and bi directional audio data contact closure amp Ethernet transmission In band management CFO161 191 singlemode Welcome a
28. nabled No video CC state Input open Output open CC output source Remote CC input LSA hold delay 20 5 seconds LSA status Disabled VSA hold time 5 seconds VSA status Disabled Audio channel 1 Enabled Balanced 6000hm on Audio channel 2 Enabled Balanced 6000hm on Audio levels 1 no signal 2 no signal Data channel 1 Enabled rs 485 75 usec Bias off Term off Data channel 2 Enabled rs 232 Data channel 3 Enabled fixed rs 232 admin CRT861 CRT861 status info example view settings CFOx61 x91 CFO432 user manual Swupdate command Use the swupdate command to update the firmware image from a tftp server Entering help swupdate displays a list of options for swupdate command Note TFTP server must be installed configured correctly and activated before using swupdate command See page 29 Example swupdate 1 1 7 10 9 96 1 Updates the firmware image version number 1 1 7 from address 10 9 96 1 27 admin CRT861 help swupdate Usage swupdate VERSION SERVER IP Update software image from a tftp server VERSION Version number of the software image file SERVER IP IP address of the tftp server admin CRT861 Termsize command Use the termsize command to display or set the terminal window s size Entering help termsize displays a list of options for termsize command admin C
29. nd thank you for purchasing Teleste s CFO Products Introduction The CFO161 191 461 491 861 891 432 are a basic building block for multi channel video transmission system providing uni directional transmission of 1 4 8 uncompressed video channels with three bi directional data two audio one contact closure and one Fast Ether net signals over single multimode fibre PAL NTSC and SECAM video formats are supported to provide a trans parent video transmission With 4 ch and 8 ch models it is also possible to transmit 2 4 S video channels that comprises of separate luminance Y and chrominance C signals Video interface is also compatible with CSX series multiplexers All common data protocols are supported as well and are easily configurable by terminal software interface Optical transmission is based on class 1M laser operation The multi plexed data stream of 1 2 1 9 Gbps enables a full quality and a zero delay latency free video transmission in one singlemode fiber over dis tances of tens of kilometres and in multimode fiber up to 1 2 kilometers approximately depends highly on fibre type Management connection between CFO units and e g laptop or PSION is based either on a serial data or a TCP IP communication by means of any terminal type program Management user interface follows the general guidelines of a Command Line Interface type operation CLI and it is meant for configuration and controlling of CFO units
30. o management the device The Telnet display is identical of local CLI view and as well the command structure follows the same rules as local CLI connection The Telnet connection can be termi nated by entering command exit Setting Transmitter Receiver IP address 10 9 96 40 10 9 96 50 Netmask 255 255 255 0 255 255 255 0 Gateway 10 9 96 1 10 9 96 1 Factory default settings for TCP IP connection CFOx61 x91 CFO432 user manual Detailed descriptions of commands Commands in brief This chapter guides how to use the command line interface CLI to configure the settings of CFO devices The CLI is a screen interface that allows the user to interact with the operating system by entering commands and optional arguments How to use the CLI commands CLI consists of several commands To execute the command press enter after typing command Entering help displays all valid commands Entering help and a command displays further options of command The remote device s settings can be changed with entering r command value Inband communication over fibre connection Ctrl c is the interrupt key sequency and returns user to the prompt Ctrl u wipe out a line of text Note All letters must be typed as lowercase all audio audiobal audioimp ccaction confget confput data databias datadwell dataterm datatype eth ethauto ethduplex ethspeed exit factory help hostname ipcfg lsa lsadelay lsaho
31. onfiguration settings dataterm and databias CFOx61 x91 CFO432 user manual Led 1 Audio 1 Led 2 Audio 2 AUDIO connector Pin Colour White green stripe Green White orange stripe Blue White blue stripe Orange NIL OO Oa AJOIN White brown stripe 8 Brown CIC603 cable s pinout wire colors RJ 45 male open wires Audio connection The CFO link contains two bi directional audio channels TX lt gt RX which can be used for one stereo audio or two mono audio purposes The AUDIO interface supports both balanced both channels sepa rately and unbalanced wiring The default audio input impedance is set to high impedance gt 10 kQ Alternatively the audio input imped ance can be set to 600 Q this setting requires balanced wiring for both channels The audio output impedance is set to 10 QO The connector type is a RJ 45 female A recommended AUDIO cable is CIC603 RJ 45 open wires The audio channels operates independently i e despite the absence of all video signals Pin Balanced signal Unbalanced signal 1 Audio 1 out GND 2 Audio 1 out Audio 1 out 3 Audio 2 out GND 4 Audio 2 in Audio 2 in 5 Audio 2 in GND 6 Audio 2 out Audio 2 out 7 Audio 1 in GND 8 Audio 1 in Audio 1 in AUDIO connector s pinout Note RJ45 connector shield is grounded Led Colour Status Green Audio 1
32. or successfull optical connections Ensure that the fiber patch cord is damage free fiber condition can be easily checked by a visible laser tester Do not exceed the minimum bending radius of the fibre Avoid sharp corners on cable shelves and in cable management in overall Ensure that correct optical connectors are used e g never use SC PC against SC APC Open connectors are always secured by dustcaps during maintenance Always before mating clean all connectors wet cleaning by high purity alcohol amp drying or dry cleaning with reel based lint free wipes fiber adapters may require special ferrule end face cleaning tools Before making any visual inspections ensure that system has been shutdown or no optical power is present For fault finding at least a optical power meter is required a complex fiber cable environment may require use of an OTDR equipment Optical connection meets class 1M laser safety requirements of IEC 60825 1 2001 and US department of health services 21 CFR 1040 10 and 1040 11 1990 Optical signal levels The optical output level are constant and dependant on the model type The typical optical output level for basic bidirectional 1310 1310 nm link CFOx61 series is 1 dBm less than 1 mW Respectively the mini mum typical optical input level at receiving end is 21 dBm In WDM operated links over 1550 1310 nm wavelenghts CFOx91 series the typical output level is 1 dBm approx 1 2 mW
33. ossover CIC505 connection adapter together with CAT5 Ethernet cable and null modem cable D9 female D9 female allowing simultaneous connection of both methods if required User groups There are two different user levels which are determined by the user name and password The Admin password can be changed with a command passwd User group Default Default Authority username password Read and write access to all Administrator admin cfoopx pages and all settings Guest guest press enter Read only access User groups for CLI 13 CFOx61 x91 CFO432 user manual Connection Description 2 x wy New Connection Enter a name and choose an icon for the connection Name CFO Managemen Naming a terminal connection Connect To xl B CFO Management Enter details for the phone number that you want to dial Country region Fraas 7 Area code er Phone number Connect using v omea Selecting COM port COM4 Properties ET xl Port Settings Bits per second no Data bits fe Parity Nore l Stop bits h y Flow control Restore Defaults Cancel Apply Settings for COM port 14 Connection methods Serial connection 1 Start the Windows Hyper Terminal program in Windows by choosing gt Start Programs Accessories Communications Hyper Terminal Wait until the following Connection Description window ap
34. pears on the screen 2 Enter a name for connection e g CFO Management and click button to continue The following Connect To window appears on the screen 3 Choose COM port where the management RS232 cable is con nected e g COM4 port and click button to continue The following COM4 Properties window appears on the screen Set here the values as described in table below Click button to continue The CFO Management window appears on the screen 4 To activate the terminal connection first press Enter gt login as appears on the screen Enter the required user name and the pass word see section user groups page 12 The Hyper Terminal window appears on the screen The terminal connection to CFO device is now completed and you can now use the CLI commands to manage the device The Hyper Terminal connection can be terminated by selecting File Exit Alt F4 or clicking X on the right upper corner of Hyper Terminal window Setting Value Emulation VT100 VT102 or ANSI Protocol RS232 serial Baud rate 115 200 kbps Data bits 8 Parity None Stop bits 1 Flow control None Port settings to terminal connection CFO HyperTerminal File Edit View Call Transfer Help Djs 218 sie 8 login as admin Password admineCRT8611 _ Type help for CLI commands When the CLI is activated admin CRT861 text appears on the sc
35. reen CRT861 is user definable hostname for the unit The Windows Hyper terminal program s window view CFOx61 x91 CFO432 user manual E Type the name of a program folder document or Internet resource and Windows will open it for you Open y Cancel Browse Run utility program view Note Assign a free IP address which is on the same subnet as the PC i e the first three sets of numbers of computer s IP address should match the first three sets of numbers of CFO s IP address 15 Connection methods TCP IP 1 Start the Run utility program in Windows by choosing gt Start Run Wait until the following Run window appears on the screen 2 Write Telnet and click button to continue The following Telnet exe window appears on the screen a C WINNT system32 telnet exe Welcome to Microsoft Telnet Client Escape Character is CTRL Microsoft Telnet gt Telnet program view Windows XP 3 Enter the following command to the Telnet prompt open IP address where the IP address is the CFO device s IP address e g 10 9 96 40 Telnet 10 9 96 40 al TES Type help for CLI commands admin CRT861 Telnet program view 4 Enter the user name and the password The following Telnet 10 9 96 40 window appears on the screen The Telnet connection to CFO device is now established and you can now use the CLI com mands t
36. signal level is good Yellow Audio 2 signal level is too low Green Yellow blinking Audio 1 signal level is too high No light Audio 1 channel is disabled Green Audio 2 signal level is good Yellow Audio 2 signal level is too low Green Yellow blinking Audio 2 signal level is too high No light Audio 2 channel is disabled Audio input connection s indicator operation CFOx61 x91 CFO432 user manual Led 1 E mode Led 2 status Mgmt connector RJ 45 D9 RJ 45 male male female 1 1 2 2 3 3 4 2 2 5 2 6 6 7 7 2 8 3 Shield 5 CIC505 connector pinout RJ 45 male D9 male RJ 45 female Management mgmt data connection Access to the device management is provided either with serial data RS 232 or with TCP IP connection The management connector type is a RJ 45 female When using TCP IP connection any type of CAT5 Ethernet cable can be used interface has auto feature Connection type is 10 100Base TX with autonegotiation enabled default Signal Ethernet mgmt Tx Rx Ethernet mgmt Tx Rx 1 2 3 Ethernet mgmt Rx Tx 4 Not used 5 6 7 Serial mgmt RS232 in Ethernet mgmt Rx Tx Not used 8 Serial mgmt RS232 out Shield Ground Mgmt connector s pinout A simultaneous management session using both connection types can be done by means of CIC505
37. tion frame e g CSR216 or 316 series and secured with the four locking screws The unit can be freely positioned in any slot in the frame Alarm card slot excluded The empty positions in the frame should be blanked off with cover plates The supply voltage is to be provided by a CPS384 or CPS390 power supply unit Video connections and indicator leds The impedance of the video connection BNC female is 75 Q The nominal input output level is 1 Vpp Video connection is equipped with the dual colour VIDEO led on the front panel See table below for explanation of VIDEO indicator led s lights CSX Multiplexer operation Alternatively the video channel can be used for CSX series multiplexer operation gt multiplexed audio data contact closure transmission No extra adjustments are needed S video operation It is also possible to transmit either two or four S video signals that comprises of separate luminance Y and chrominance C signals except CFO161 Connect Y and C signals to any of video inputs Make sure that the Y and C connections are corresponding both at transmitter and receiver No extra adjustments are needed Colour Status Green A signal is present and in nominal level Yellow No video signal or the video level is too low No light Video input output is disabled via management VIDEO indicator operation CFOx61 x91 CFO432 user manual Stand alone installation The CFO unit can
38. uit to stay in the original alarm state DELAY Delay in seconds admin CRT861 Lsahold command Use the Isahold command to view or change the devices source alarm hold time Entering help Isahold displays a list of options for Isahold command admin CRT861 help lsahold Usage lsahold HOLDTIME Display or set the link source alarm hold time Holdtime defines how long will a missing optic link be tolerated befor nabling the alarm HOLDT IME Hold time in seconds admin CRT861 Lsareset command Use the Isareset command to reset device source alarm to its initial state Entering help Isareset displays a list of options for Isareset command admin CRT861 help lsareset Usage lsareset Reset link source alarm to its initial state All the timers are cleared and contact closure circuit set to the resting state admin CRT861 CFOx61 x91 CFO432 user manual Passwd command Use the passwd command to change password for current user Enter the new password minimum of 5 characters Please use a combination of upper and lower case letters and numbers Entering help passwd displays a list of options for passwd command admin CRT861 help passwd Usage passwd OLD PASS NEW PASS Change the password for user admin OLD PASS Admin s current password NEW PASS The new password for admin admin CRT861 R command Use the r command to change remote dev
39. ut relay max 30 V 1A switching Received power 21 dBm CFOx61 min Data rate 5 Hz max Received power 23 dBm CFOx91 min Ethernet Bridge Video Number of ports 1 bi directional Number of channels 1 uni directional CFO161 191 4 uni directional CFO461 491 Port type 10 100Base TX configurable 8 uni directional CFO861 891 Compliant IEEE802 3 IEEE802 3U Standard CVBS CFO161 191 Management CVBS or Y C CFO461 491 861 891 Input and output signal levels 1 Vp p Command Line Interface RS 232 and or TCP IP terminal Input overload level 1 5 Vp p DC component SNMP v2 MIB II remote via network Impedance 75 ohm General Sampling 10 bits 15 55 MHz Supply volt 10 5 14 V DC lated Bandwidth 6 5 MHz 3dB Me rege ren 3 Current consumption max 750 mA steady state i i Dimensions H x W x D 3U 10HP 190 mm CFO161 191 461 491 C L delay inequality 40 ns max 3U 15HP 190 mm CFO861 891 Biicrenel ein 2 Divs Weight 0 8 kg CF0161 191 Differential phase 25 max 0 9 kg CFO461 491 861 891 S N ratio 67 dB unified weighted Connectors Data Video BNC female Sent Data audio cc mgmt Ethernet RJ 45 female Number of channels 3 bi directional Optical SCIAPC 8 Selec Data 1 amp 2 format RS232 422 485 selectable F Environmental Balas format Ree ikea Operating temperature 34 74 C Data as l 0 230 kbps all eee re 34 74 C Dwelltime setting 50 10000 us RS485 2 wire Humidity 0 95 non condensing Audio EMC compatibility EN61000 6 4 EN50130 4 CE AAA FCC CFR