Owners manual Dock shelters
Contents
1. 1 1 1 2 1 3 1 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 General Use of the manual Operator Technician Guarantee csm pi After SaleS ooccooncooccconccoonconncoanonnnonanonns Regulative non regulative use Safety precautions with regard to the dock shelter Description of the dock shelter Description of the system Technical data une Assembly installation inspections Operation ee ee enegeer Troubleshooting u nisse Maintenance WOrks ccsssccseeeeeeeeees Alignment 6PPRRREREREEFMISEEREPEERNEIEEEEBEHEEEREESERERE Out of operation ccccccccsseceeeeeeeeees Disassembly removal and processing 1 1 Use of the manual This manual describes how Lindab dock shelters are to be operated which safety measures are to be ob served including a description of the dock shelter as well as how defects may be solved This description has been made for the use by the opera tor of the dock shelter and indicates that after reading the manual you shall be capable of operating the dock shelter however not authorised to solve dock shelter related defaults With regard to technical defaults you are to contact a qualified engineer Text layout Text in Italic information to which extra attention is to be given Text in bold important information Symbols used A Warning Should instructi
2. handling of the materials delivered may be proven 5 The dock shelter has been used for other purposes than for which it has been designed and constructed 1 4 After Sales Should defaults or problems occur or should you have any questions please contact Lindab 2 1 General 4 Notwithstanding all safety measures as ensured by Lindab the following aspects are to be taken into consi deration e During the operation of the dock shelter the surroundings are to be observed if possible e One is not to insert any objects between underneath or into the dock shelter or any moving parts of the dock shelter e Each person is to ensure a certain distance during the movement of the surface of the dock shelter e The direction of the movement of the surface of the dock shelter should not be blocked in order to ensure free movement The manufacturer cannot be held liable for any handling or works which have been performed by a non authorised non qualified or not sufficiently qualified user operator or technician 2 2 Regulative non regulative use 4 Safety precautions e Prior to operating the dock shelter for the first time the operator is to read the full contents of the pertai ning manual e The dock shelter is to be used in accordance with the instructions Any other use could result in unpredic table circumstances or occurrences and is therefore strictly forbidden e The instructions as stipu
3. lated in the manual are to be observed to the letter e Always disconnect the power regarding electrical operated dock shelters only prior to working on the system Always ensure that no unaut horised activation of the power can be performed e Special attention is to be given to ensure that the control unit is always closed during operation regarding electrical operated dock shelters only e Only a technician who has com pleted an electro technical course may open the control unit A Safety comes before Opera tion 2 3 Safety precautions with regard to the dock shelter 4 Safety precautions e The manufacturer has given utmost attention to the safety of the dock shelter and provided a vast array of safety precautions e Periodically 1x per month an inspection is to be carried out regarding whether or not the safety precautions are compromised and that they still perform e Always disconnect the power regarding electrical operated dock shelters only prior to working on the system Always ensure that no unaut horised activation of the power can be performed Moreover the working area is to be fenced off to clearly indicate the working area 3 1 Description of the system The dock shelter and the movable sections have been designed and constructed with regard to the opening and closing of openings in buildings during the loading and un loading process Depending on the model the mo
4. odern logistics systems For more information www lindab dk Lindab ff Lindab Profil A S Tlf 45 73 99 73 73 www lindab dk
5. ons be pre ceded by this symbol this indicates a warning regarding the possible risk of damaging the dock shelter or risk regarding occurring defaults should the instructions not be observed to the letter Should text be preceded by this sym bol this indicates a warning against the risk of physical injury should the instructions not be observed to the letter 1 2 Operator Technician User The user is each person handling the dock shelter in any way Operator The operator is each person who is under normal circumstances invol ved with handling the dock shelter The operator is to be familiar with all stipulations regarding safety as detailed in this manual The operator is not to perform any repair activities on or to the dock shelter Technician The technician is a technician qua lified to perform technical repairs on or to the dock shelter He she is qualified to perform mechanical and or electro technical repairs to the system s and or maintenance activities 1 3 Guarantee The guarantee conditions as inclu ded in the General Conditions of Sales and or Guarantee shall be deemed legally null and void should 1 Maintenance works and or repairs have been performed whilst not ob serving the instructions to the letter 2 Assembly repair works have not been performed by a qualified engi neer 3 Other than original spare parts have been used 4 Non judicially unjust and or negligent
6. pon reaching the end positions the motor shall be deactivated Should after a certain pulse the dock shelter not activate a certain function it could be that one of the described safety precautions has been activated In this case please check Should the latter not be ap plicable please refer to Chapter 3 5 Troubleshooting 3 5 Troubleshooting Should the dock shelter not react immediately upon the activation of the control unit or should the dock shelter for some reason halt the fol lowing procedure is to be observed e Check if optional security devices wheel chock safety fence etc function properly Due to the se quence control the functioning of the dock shelter could be influenced by a disfunctioning security device e Check if an obstacle is present within the direction of moment which prevents the freedom of movement of the dock shelter Remove the object if So required e Check if the plug applicable for electrical operated doors only is connected to the wall socket If not insert the plug Should the defects not be solved please contact Lindab Technical Service and inform them accor dingly The user may never perform overriding the set safety precauti ons Other works may not be per formed by the user for this could mean termination of the guarantee 3 Description of the dock shelter 3 6 Maintenance works Complicated maintenance works require qualified knowledge For your own
7. rded against unintended and unauthorised use 3 9 Disassembly removal and processing The manufacture of the dock shelter has been as such that the disas sembly shall need to be performed by qualified personnel The manu facturer cannot be held liable and or responsible for any unjust or incorrect disassembly as performed by third parties With regard to the materials as used for the production of the system no specific circumstan ces or procedures need to be taken into consideration with regard to removal and processing All parts are to be removed in accordance with the at that time valid environmental regulations Lindab Ovners manual Dock shelters Lindab Coverline for roof and facades is the best solution for agricultural and industrial buildings The sheets are available in many types of profiles and colours which can easily be combined and offer a great number of possibilities A strong and durable solution A complete range of strong reliable sectional over head doors which are ideal in meeting the tough demands to industrial and farm buildings There is a wide selection of colours and attractive combina tion options so you have great freedom of design Bu using Lindab loading docks shelters and industrial overhead doors you achieve the ultimate system to ensure a good working environment and efficient logistics Efficient unloading and loading of goods onto vehicles is an important parameter in m
8. safety we strongly advise you to contact your supplier if complicated maintenance works are required Skilled personnel within the own organisation can perform the following maintenance What to do How to do Fasten if required Exchange damaged rubber springs Check top flaps side flaps cushion Contact your supplier should dama on damages ges be detected Figure 1 Bolt connection back Figure 2 Bolt connection back portal in order portal too loose tighten Figure 3 Bolt connection front Figure 4 Bolt connection front portal in order portal too loose tighten 3 7 Alignment Upon assembly the dock shelter system shall be aligned as such that the settings comply with the agreed upon requirements The user is not to initiate any modifications to the settings Should any modifications be applicable at a later stage the supplier is to be contacted after which these shall be modified by the supplier Should any modifications be per formed with regard to the settings as set by the manufacturer either by the user or by any third party termination of the guarantee could be a result of unauthorised modifi cations 3 8 Out of operation 4 In order to be able to perform main tenance works by a technician or should the dock shelter be out of order for a longer period of time the power is to be disconnected applicable for electrical operated dock shelters only and it should subsequently be safegua
9. vements opening and closing are manually operated or activated by an electrical signal 3 2 Technical data Frame Steel and aluminium Motor 230V 0 25 kW if applicable Frequency 50 Hz Control panel 230V 50 Hz 3 3 Assembly installation inspections A The dock shelter is to be assembled by a technician approved by Lindab Prior to the initial use of the dock shelter the appointed technician has inspected the safety and the ope ration of the dock shelter and has released it for use to the appropriate user or operator 3 4 Operation The dock shelter s operational sy stem is set to the options as agreed upon with the user operator The functions as detailed below could therefore based on the control tech nology be available Mechanical operation e Resulting in the docking of the vehicle the closing off sealing shall be initiated Electrical operation e The push button on the control pa nel with regard to manual control has been positioned as such that the risk area can be viewed from the control position e The control panel has been provi ded with 2 control functions Open and Closed As long as the control function is activated the top cushion series 400 shall move e The dock shelter functions by means of pulse control and has one button for Open and Close The end switches as integrated in the dock shelter monitor the end posi tions of the top cushion and u
Download Pdf Manuals
Related Search
Related Contents
Monarch Specialties I 2555 Instructions / Assembly 87780Manual mantenimiento ventiladores Mach Samsung 34'' ukrivljen monitor S34E790C Uporabniški priročnik Class 66/77 - Train Service Danckaert 取扱説明書 温水洗浄一体型便器 AXUシリーズ - Oriental Motor Benutzerhandbuch für die Dateiverwaltung in BR 60/95 RS Bp BR 60/95 RS Bp Pack BD 60/95 RS Bp BD 60/95 product user guide Copyright © All rights reserved.