USER GUIDE ILH

image

Contents

1. TE C gt T C Setpoint 21 5 C 10 10 5 pa i VOC ppm 0 VOC Setpoint 800 ppm e g 700 ppm e g 21 0 C N Control output V 10 VOC 6V Temperature 3 V Humidity 4 V 5 RH 0 t gt T RH Setpoint 55 e g 50 Potentiometer menu t POTENTIOMETER Y4 V Off Y3 Y4 lt Potentiometer output j y mm Control output 6 V Potentiometer menu is available if HD PU option is installed You can select the potentiometer output connector and disable the potentiometer through the menu The potentiometer is connected to the Y4 output as factory setting Produal Oy Keltakalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 Information is subject to change without prior notice info p ro dual fi www produal com Pd PRODUAL measure be sure USER GUIDE ILH 7 10 Relay menu QB Relay T Y o 1100 RELAY ic RelON VOC z Hysteresis VOC l M Relay set point 450 2000 ppm Hysteresis 0 100 from R Q Relay TEMPERATURE aA C eee C Relay set point Hysteresis 0 50 C 0 20 C Relay 50 8 8 HUMIDITY RelON RH RH D Relay set point Hysteresis 0 100 0 50 Relay 1100 23 0 8 ALL RelON VOC P VOC RelON C iu c Relay set point Hysteresis Relay set point Hysteresis 450
2. Q O O9 90999 O Q999 ime l A ML SER cable VOC measurement value shows on the ML SER tool display Produal Oy Kelta kalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 info produal fi www produal c om Information is subject to change without prior notice Pd PRODUAL measure be sure USER GUIDE ILH 3 10 ML SER menu ML SER menu opens by pressing the M button The values can be changed with the device specific and the content depends on the device and installed options so and buttons The menu is 900 m gt Measurement VOCppm V S B S Modbus f 96 n menu COMMUNICATIONS MODBUS ID Baud rate k Parity M Modbus address Modbus speed Parity bit OFF 1 247 9 6 19 2 38 4 None Even Odd lt Y 68 OR OR OR Calibration 0 menu CALIBRATION Offset VOCppm ee c F RH O VOC measurement Temperature measurement Humidity measurement p tuning 200 ppm tuning 3 0 C tuning 5 RH Cont OFF y OF OR Controller Cont PI 300 700 500 CONTROLLER voc Control mode Integr time s VOC Setpoint VOC Propor band O A Control method Int
3. _ il aN HABA APRA AR AAA TEE US EEEE Display mode Og a oS go Stop Scan 0000 o pd a OIOTS CTSISSIS CICISNCICIS Fi A S1 button NOTE In M models the shown measurement information can be selected also via Modbus Produal Oy Keltakalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 info produal fi www produal com Information is subject to change without prior notice USER GUIDE Pd PRODUAL hi measure be sure 2 10 ML SER TOOL With the ML SER tool you can change the device settings controller and Modbus settings for example Connecting ML SER tool to the device 1 Remove the display HD AL3 option 2 Connect the ML SER cable to the connector i j Ekel mo 10 gt r
4. 10 100 Control mode Cont gt f 700 500 MAXIMUM CTRL os trol mode gt ime s VOC Setpoint VOC Propor band Control method Integration time VOC set point VOC proportional band EN PI P R 50 5000 s 450 2000 ppm 100 2000 P Control mode 210 C Setpoint 7 Propor band Setpoint ai Propor band C set point C proportional band RH set point RH proportional band 18 26 C 1 0 32 0 0 100 10 100 ke ij Vv The control output can be controlled either according to a one measurement value or according to the maximum selection of all values Humidity related settings are only available in RH models The VOC values can be adjusted by 10 ppm steps The temperature values can be adjusted by 0 1 C steps The humidity values can be adjusted by 5 steps Produal Oy Keltakalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 Information is subject to change without prior notice info p ro dual fi www produal com Pd PRODUAL measure be sure USER GUIDE ILH 6 10 In the maximum selection control the control output signal is formed according to the measurement that causes the largest control signal value The following situation is in the example figure e VOC level is 800 ppm e Temperature is 21 5 C e Humidity is 55 A Control output V A Control output V
5. 1100 RelON VOC fe teresis VOC Relay set point Hysteresis Relay Relay menu RELAY voc GR 2 Pa T p Bg 450 2000 ppm 0 100 from range y J 6R TEMPERATURE ReION c Hysteresis C A Relay set point Hysteresis 0 50 C 0 20 C y R OR Relay 50 5 HUMIDITY RelON RH Hysteresis RH Gh Relay set point Hysteresis 0 100 0 50 Y 0 T Relay 1100 gt i 23 0 B ALL RelON VOC Fi ees VOC RelON C ie C Relay set point Hysteresis Relay set point Hysteresis 450 2000 ppm 0 100 from range 0 50 C 0 20 C an RH a Hysteresis RH Relay set point Hysteresis 0 100 10 50 lt Y AL3 750 1250 menu AL3 YELLOW RED M Yellow indicator light illumination Red indicator light illumination point 450 2000 ppm point 450 2000 ppm lt Info y i 100 mene je gt VERSION gt nET O OR Software Reset to factory settings version no yes Modbus menu 1 96 n COMMUNIC ATIONS MODBUS ID Baud rate k Parity M Modbus address Modbus speed Parity bit OFF 1 247 9 6 19 2 38 4 None Even Odd lt Modbus menu is available in M models The bus settings can be changed through the menu Calibration menu w S S 0 00 0 i re gt Offset VOCppm Hli fe Offset ARH O VOC tuning Temperature measure
6. 2000 ppm 0 100 from E 0 50 C 0 20 C gt re z pre Ri P Relay set point 0 100 Hysteresis 0 50 lt y Relay menu is available if HD R option is installed The relay switching point and hysteresis can be changed through the menu The relay output can be controlled either according to a one measurement value or according to the all values Humidity related settings are only available in RH models e The VOC values can be adjusted by 10 ppm steps e The temperature values can be adjusted by 0 1 C steps e The humidity values can be adjusted by 1 steps When the output is controlled according to the all values the relay activates when one measured value exceeds the set point AL3 menu YELLOW Yellow indicator light illumination point 450 2000 ppm Red indicator light illumination point 450 2000 ppm AL3 menu is available if HD AL3 option is installed The indicator light limits can be changed through the menu The hysteresis is 50 ppm Info menu 1 4 0 VERSION M Software version You can check the device software version and reset the device to factory settings through the Info menu RESET Reset to factory settings no yes Produal Oy Kelta kalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 Information is subject to change without prior notice info p ro dual fi www pr
7. 30007 Y4 output voltage Unsigned 16 0 1000 0 00 10 00 V 30008 Active potentiometer value Unsigned 16 0 1000 0 0 100 0 Holding registers Register Parameter description Data type Values REWI Default 40001 Y1 output overdrive Signed 16 0 1000 0 10 00 V 0 40002 Y2 output overdrive Signed 16 0 1000 0 10 00 V 0 40003 Y3 output overdrive Signed 16 0 1000 0 10 00 V 0 40004 Y4 output overdrive Signed 16 0 1000 0 10 00 V 0 40005 VOC measurement tuning offset Signed 16 200 200 200 200 ppm 0 40006 Temperature measurement tuning offset Signed 16 30 30 3 0 3 0 C 0 40007 Humidity measurement tuning offset Signed 16 5 5 5 5 0 40008 Control method Signed 16 0 1 i a 1 0 not in use 1 VOC 40009 Controller output Signed 16 0 1 2 3 4 2 temperature 1 3 humidity 4 maximum selection 40010 Set point VOC Signed 16 450 2000 450 2000 ppm 700 40011 Set point temperature Signed 16 180 260 18 0 26 0 C 210 40012 Set point humidity Signed 16 0 100 0 100 50 40013 Proportional band VOC Signed 16 100 2000 100 2000 ppm 500 Produal Oy Kelta kalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 info produal fi www produal c om Information is subject to change without prior notice Pd PRODUAL USER GUIDE b ILH measure bDe sure 10 10 Register Parameter description Data type Values Ra
8. Pd PRODUAL USER GUIDE ILH measure be sure V1 0 0 20 02 2015 1 10 MOUNTING The device can be installed in dry surroundings IP20 by screws on the wall surface or on the standard flush mounting box The recommended installation height is 150 180 cm The device position should be selected carefully All the error factors that can affect to the measurements should be eliminated as well as possible The following list defines the typical measurement error factors e direct sun light occupant proximity e air flow coming from windows or doors air flow coming from ventilation nozzles air flow coming from the flush mounting box e differential temperature caused by external wall Wiring Device wiring and commissioning can only be carried out by qualified professionals Always make the wirings while the power is switched off Caution 24 Vac de 0 Vac 0 10 V VOC 0 10 V temperature 0 10 V humidity RH models potentiometer HD PU 0 10 V controller output potentiometer HD PU AAAA Y Modbus RS 485 M models 24 Vac 1 A relay HD R A R3k Passive potentiometer A Ri HD P not in M models 21 SELECTING THE MEASUREMENT INFORMATION TO BE VIEWED ON THE DISPLAY The measurement values scroll on the N model display The wanted value can be locked to view continuously by pressing the S1 button You resume to the scrolling view by pressing the S1 button again
9. egration time VOC set point VOC proportional band gt PI P R 50 5000 s 450 2000 ppm 100 2000 P Control mode Y GR OR 6R Cont PI 300 21 0 TEMPERATURE Control mode Integr time s C Setpoint a Propor band A Control method Integration time C set point C proportional band GN PI P 50 5000 s 18 26 C 1 0 32 0 P Control mode AA D o OR 6R 6R HUMIDITY Control mode Integr time s a Setpoint Ge Propor band A Control method Integration time RH set point RH proportional band G PI P 50 5000 s 0 100 10 100 P Control mode Y Cont PI __ 300 700 500 MAXIMUM CTRL Control mode iniegr time s VOC Setpoint VOC Propor band Control method Integration time VOC set point VOC proportional ial EN PI P R 50 5000 s 450 2000 ppm 100 2000 P Control mode 21 0 20 50 50 C Setpoint C Propor band ARH Setpoint 4RH Propor band C set point C proportional band RH set point RH proportional band 18 26 C 1 0 32 0 0 100 10 100 e Yy Potentiometer 63 63 mana POTENTIOMETER gt v4 Potentiometer output M OFF Y3 Y4 lt v The diagram continues on the next page Produal Oy Keltakalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 Information is subject to change without prior notice info p ro dual fi www produal com PdPRODUAL USER GUIDE ILH measure be sure 4 10 B
10. ment Humidity measurement 200 ppm tuning 3 0 C tuning 5 RH All the measurements can be tuned through the calibration menu The humidity tuning is available only in RH models e The VOC value can be adjusted by 10 ppm steps e The temperature value can be adjusted by 0 1 C steps e The humidity value can be adjusted by 1 steps ML SER tool display shows how much the current value is tuned Produal Oy Keltakalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 info produal fi www produal com Information is subject to change without prior notice 5d PRODUAL USER GUIDE measure be sure re Controller menu Cont OFF Y R OR CR l Cont fw 70 at CONTROLLER voc ne mode rT Integr times VOC Setpoint al Propor band M A Control method Integration time VOC set point VOC proportional band G PI P 50 5000 s 450 2000 ppm 100 2000 P Control mode Pi Cont ee ea Qt Pf Po 300 21 0 Control mode Integr time s C Setpoint fi Propor band Control method Integration time C set point C proportional J PI P 50 5000 s 18 26 C 1 0 32 0 f Control mode ty A Setpoint A Propor band P C8 Cont Pi 300 HUMIDITY Control mode Integr time s A Control method Integration time RH set point RH proportional band o PI P 50 5000 s 0 100
11. nge Default 40014 Proportional band temperature Signed 16 10 320 1 0 32 0 C 20 40015 Proportional band humidity Signed 16 10 100 10 100 50 40016 Integration time Signed 16 50 5000 50 5000 s 300 0 OFF 40017 Active potentiometer output Signed 16 0 1 2 1 Y3 2 2 Y4 40018 Relay set point VOC Signed 16 450 2000 450 2000 ppm 1100 40019 Relay set point hysteresis VOC Signed 16 0 100 0 100 5 40020 Yellow AL3 indicator light illumination limit Signed 16 450 2000 450 2000 ppm 750 40021 Red AL3 indicator light illumination limit Signed 16 450 2000 450 2000 ppm 1250 0 VOC 1 temperature 40022 Value shown on the display Signed 16 0 1 2 3 2 humidity 3 3 scrolling 40023 Not in use Signed 16 1 40024 Not in use Signed 16 0 40025 Relay set point temperature Signed 16 0 500 0 0 50 0 C 230 40026 Relay set point hysteresis temperature Signed 16 0 200 0 0 20 0 C 20 40027 Relay set point humidity Signed 16 0 100 0 100 50 40028 Relay set point hysteresis humidity Signed 16 0 50 0 50 5 0 not in use 1 VOC 40029 Relay function Signed 16 0 1 2 3 4 2 temperature 1 3 humidity 4 all Produal Oy Kelta kalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 info produal fi www produal c om Information is subject to change without prior notice
12. odual com Pd PRODUAL USER GUIDE b ILH measure be sure 8 10 MODBUS Bus properties Protocol RS 485 Modbus RTU Bus speed 9600 19200 38400 bps Data bits 8 Parity none odd even Stop bits 1 Network size up to 128 devices per segment The parameter memory durability allows at least 1 million writing cycles Bus termination The Modbus can be terminated by placing the MBUS TERM jumper D I O anonnonnnnnnnannnnnnn Q Q Q EPRPEPEEERREREEEERE O Q Display mode 000 z Q H ml o D Ex Q 2 Stop Scan ad S Z O SITERM o 4k 3 Q o ei t A MBUS TERM jumper Modbus function codes The device supports the following Modbus function codes 0x01 Read Coils 0x02 Read Discrete Inputs 0x03 Read Holding Registers 0x04 Read Input Registers 0x05 Write Single Coil 0x06 Write Single Register 0x0F Write Multiple Coils 0x10 Write Multiple Registers 0x17 Read Write Multiple Registers Produal Oy Kelta kalliontie 18 48770 Kotka FINLAND Tel 358 10 219 9100 Fax 358 5 230 9210 info produal fi www produal c om Information is s
13. ubject to change without prior notice Pd PRODUAL measure be sure USER GUIDE ILH 9 10 Modbus registers NOTE If you try to write a parameter value that is beyond the parameter value range the value will be replaced by the nearest acceptable value For example if you write 270 to the register 40011 the value will be replaced by 260 Coils Register Parameter description Data type Values REWI Default 1 Y1 output overdrive activation Bit 0 1 0 Off 1 On 0 2 Y2 output overdrive activation Bit 0 1 0 Off 1 On 0 3 Y3 output overdrive activation Bit 0 1 0 Off 1 On 0 4 Y4 output overdrive activation Bit 0 1 0 Off 1 On 0 5 Relay overdrive activation Bit 0 1 0 Off 1 On 0 6 Relay overdrive Bit 0 1 0 Off 1 On 0 Discrete inputs Register Parameter description Data type Values 10001 Relay status Bit 0 1 0 Off 1 On Input registers Register Parameter description Data type Values REWI 30001 VOC measurement CO equivalent Signed 16 0 10000 0 10000 ppm 30002 Temperature measurement Signed 16 0 500 0 0 50 0 C 30003 Humidity measurement Signed 16 0 1000 0 0 100 0 30004 Y1 output voltage Unsigned 16 0 1000 0 00 10 00 V 30005 Y2 output voltage Unsigned 16 0 1000 0 00 10 00 V 30006 Y3 output voltage Unsigned 16 0 1000 0 00 10 00 V

Download Pdf Manuals

image

Related Search

Related Contents

MOEN TS6205BN Installation Guide  Rockford Fosgate bd1000P/bd1500P User's Manual    J:COM千葉セントラル サポートサービス利用規約 1 J:COM1504  Supermicro X7DA8-B motherboard  RCA 32v432T CRT Television User Manual  AutoDome 600 Series Analog PTZ Camera  Nilfisk-Advance America MX 307 H User's Manual  Warranty Template Structual Adhesion Latin America    