Home

TECHNICAL DESCRIPTION, USER MANUAL AND

image

Contents

1. folding safety rails x bumpers oot lever to set castors oxygen bottle holder 2160 mm 2000 mm 90 mm 640 mm O 90 13 120 kg 690 mm lockable gas spring linear hydraulic pump waterproof mattress cover resistant to blood urine oil fat and disinfectants available in light grey and black 180 kg folding safety rails castors with central locking system personal storage basket and oxygen bottle holder integrated into the base SIF STR infusion stand LE6 fixation rail 4 USER MANUAL e height adjustment LIFTING To lift the table press the foot lever 1 on the left or right side of the table LOWERING To lower the table press on both foot levers at the same time 2 and 3 TRENDELENBURG AND ANTI TRANDELENBURG POSITION To lower the head section press foot lever 2 To lower the foot section press the foot lever 3 lever e head section adjustment Press the lever move the head section into desired position and release the lever e safety rails To place the rail into upright position simply lift it In the upper position safety pin gets stuck and prevents the rail from folding To fold the rail hold it and remove the pin then push the rail down e Castors with central locking system All four castors are blocked restrained in direction or freed by pressing the foot lever at any of the four castors Blocked castors do not turn Castors restrained
2. in direction do not rotate around their axes This function makes Stretcher S easy to manage Freed castors can rotate in all directions e Oxygen bottle holder Place the oxygen bottle and tighten it with an added band 5 OPTIONAL ACCESSORIES e Fixation rail LE6 Fixation rail is intended for attachment of optional accessories e Infusion stand SIF STR Infusion stand is attached and hidden on the head section Before use set the infusion stand into upright position where it gets stuck After use pull it lightly up and put it into horizontal position 1 Height is adjusted by means of a screw 2 or a patent for one hand height adjustment 3 6 DECLARATION OF CONFORMITY Manufacturer Novak M d o o Address Brezovce 7 1236 Trzin SLOVENIJA Product Miza stretcher S Model STRS Classification MDD annex IX class Hereby we declare that the stated products are in accordance with EC directives All according documents are archived at manufacturer MEDICAL DEVICE DIRECTIVE MDD 93 42 EGS Trzin 20 6 2008 Name Novak Miha Function direktor Signature ZA 7 GUARANTEE CERTIFICATE product Stretchers r r r4nrnr Llu model SIRS eee customer M I I LL LLLLLLLLITO address NAOVA NA YNOVvaAK M 775 EE producer s signature and stamp Pii als tam distributor s signature and stamp service Novak M d o o Guarantee conditi
3. Novak M d o o VV VV VL PLE A e mail info novak m si iicail equipment I 386 1 5620117 F 386 15620118 TECHNICAL DESCRIPTION USER MANUAL AND MAINTENANCE STRETCHER S Thank you for your trust You have chosen a good product CONTENT 1 Safety and maintenance 2 Short overview 3 Technical description 4 User manual 5 Optional accessories 6 Declaration of conformity OV WD OT KEP U WN 7 Guarantee certificate 1 SAFETY AND MAINTENANCE Before the first use Remove the wrapping foil from the table Do not use any sharp objects not to damage the upholstery Cut safety bands which disable height adjustment during transport at table base Safe use Trolley castors coated in rubber are not intended for transport outdoors Do not place hands or feet between the moving parts of the table Do not leave children unattended near the table as serious injuries can occur Upholstery and metal parts are to be cleaned by a mixture of detergent and water and wiped dry Use non abrasive Cleaners Lubrication of moving parts is unnecessary Product lifetime is 5 years Package handling Wrapping is made of environment friendly material that can be recycled Make sure all wrappings go to the right disposal 2 SHORT OVERVIEW STRETCHER S pin to fold safety rail personal storage basket foot lever to adjust height 3 TECHNICAL DESCRIPTION table length optional accessories
4. ons Novak M d o o offers a 48 months guarantee for its products commencing on the day of purchase Guarantee for upholstery material is 12 months Should guarantee repairs be necessary the customer must inform the producer or an authorized dealer The guarantee must be verified by purchase invoice The guarantee obligates Novak M d o o to carry the costs of repair of all parts or components which might fail during normal use inside the guarantee period Guarantee does not cover defects or poor performance fa customer does not follow the requirements and recommendations set out in the user manual Caused by unauthorized modification or attempted repair Caused by customer s misuse or neglect If some not genuine parts are build into the product Caused during transport after the product is handed to the customer Guarantee repairs should be done in 45 days otherwise the product is replaced Repair and spare parts are available for 5 years from the date of purchase

Download Pdf Manuals

image

Related Search

Related Contents

1 Indicações de segurança 2 Estrutura do aparelho  Kensington Comercio™ Soft Folio Case & Stand for Galaxy Tab® 3 10.1 - Plum  Bailey Birkett  4. Betrieb Schaltgerät  User Manual - Tangent Devices    Classic S127 Mode d`emploi  

Copyright © All rights reserved.
Failed to retrieve file