Home
Description of CO2-Neutral ISPA Water Filter FS200 USER MANUAL
Contents
1. Independent Solar Power Agency Aps Description of CO2 Neutral ISPA Water Filter FS200 USER MANUAL This ISPA FS200 water filter cleans contaminated pre filtered fresh water transforming it into clean drinking water in a short period of time The cleaning process takes place by the water passing through a series of treatment processes in terms of filters and activated carbon being UV treated by the sun through the hardened glas The ISPA water filter is developed designed and produced in Denmark The ISPA water filter complies with described Danish safety provisions INPROPER USE MAY CAUSE DAMAGE TO PERSONS AND PROPERTY The specifications in this manual may change without notice In order to avoid damage to persons and or device please read this manual carefully before putting the FS200 into operation We recommend you keep the manual for future use Warning and Safety Instructions The FS200 is only supposed to be used for purification of contaminated fresh water The manufacturer is not responsible for errors arising from wrong handling or because the device was used for other purposes than specified In order to avoid accidents and injuries please pay attention to the following The F200 cannot work properly when placed flat on the ground It must be installed for instance on the side of a wall in a somehow upwards position with respect to catching the rays of the sun in the most efficient way FS200 must be ins
2. NCE INSTALLATION TRANSPORT Preventive Maintenance The FS200 will work satisfactory when the following preventive procedures are followed FS200 may only use activated carbonated charcoal delivered from the distributor Please contact bn ispa dk To ensure quality and efficiency of cleaning process please replace activated coal every 3 years F200 micron filters to be replaced every 3 months or when necessary Please from bn ispa dk FS200 is delivered with 1 set of replacement filters for continuos drinking water flow for 6 months You replace micron filters by gently placing the FS200 in horizontal position with the front down You then gently unscrew the filters and replace them with new ones External cleaning of FS200 is done weekly by using a brush or damp cloth No chemicals shall be used So called BACKWASHING is to take place every week 7 days or when necessary The backwashing process is when you let clean water run into FS200 reversely from the normal process meaning you let clean water run into the outtake and out through the intake In case of doubts related to this place ask ISPA or distributor for advice Transport FS200 must be protected against shock moisture and frost during transportation Damaged packages must be opened in the presence of staff from the delivery company which on the consignment note must witness the damage Only photos will be accepted as evidence When transportin
3. g the device after having put into service please empty the device for water before transport This is done by turning the device upside down for minimum one hour after disconnection of the water Device may be moved around without emptying for water as long as you keep it in vertical position TECHNICAL DATA Dimensions Width 500 mm Depth 85 mm Height 400 mm Weight 18 kilo Maintenance and Repairs Maintenance and replacement of parts and repairs must be performed only by qualified technical personnel ISPA signs a service contract that covers maintenance and repairs with local distributors in order to ensure a continuous and optimum service of the device Questions about the product can always be addressed to Director of Production Bent Nyholm bn ispa dk or phone 45 22 81 74 16
4. talled outside facing the sun on a firm level surface Preferable on a wall or individual grid Distance vertical from reservoir to water intake must be some 70 cms to ensure required water pressure for the cleaning process Max 70 cm is essential as the water needs a certain time processing the activated charcoal and Uvlight from sun inside the core The FS200 may only be sold and maintained through authorized dealers and technicians Avoid that people who are not qualified have read this manual operate the device Accessories for FS200 Only use external filters and or fittings recommended by ISPA By Receipt of FS200 Check device for obvious damage before installation An obviously damaged device shall never be used USE OF THE FS200 Installation Check that all packaging material around the device is removed Place the FS200 on a solid surface or install it on a wall Connect the hose with dirty water from reservoir to intake and put a container under the hose with clean water from the outtake Preparation for use When installing a new FS200 it is required to let the water run for minimum 1 hour in order to ensure a fresh flow of fresh clean water When FS200 has been idle for a week or more please repeat this procedure for 10 15 min Always connect the hose with dirty fresh water to the STAGE 1 filter and to place a container for clean drinking water under STAGE 2 filter Always stop flow by STAGE 1 filter MAINTENA
Download Pdf Manuals
Related Search
Related Contents
Dosssier pour la DDT obligatoires Voir le feuillet d`information G DATA Roberts Radio SRC955 User's Manual SDX-400C/RS Manual de Instalação DEISSOFF ASUS E6536 User's Manual Tuirel S777 User Manual Copyright © All rights reserved.
Failed to retrieve file