User's manual and installation instruction Personal

image

Contents

1. Gas smoke alarm The Propane detector is best tested with a short squirt of gas from a cigarette lighter directly into the external low mounted sensor housing Motion detector test The outside mounted motion detectors are best tested by walking in the detector zone until the alarm sounds This should normally be approximately 30 seconds False alarms NX 4 will normally react on the propellant gas in spray cans and many other chemicals If the air quality gets poor because of insufficient ventilation or cigarette smoke the alarm can react If you desire to accept the poor air quality reduce the sensitivity settings to the desired level The Gas and Gas Smoke detectors are sensitive to alcohol and will normally react if alcohol is handled near the NX 4 If you are breading on the NX 4 after consuming alcohol it shall react Smokers may experience alarms even if they are not smoking at the moment This is because of the air quality is generally poorer than normal and a small added pollution could be enough to trigger the alarm If so a lower sensitivity setting or added ventilation may be required NX 4 is very sensible to car exhaust so if NX 4 is ON while driving you will experience alarms when driving in tunnels close behind other cars or in heavy traffic However this should not be a problem because NX 4 is normally OFF while driving It does not harm anything to have it ON but if motion detectors are installed the ala
2. NX 4 is normally used when you are sleeping Flip the power switch to ON position and the red Heating lamp will light After a heating period of 2 3 minutes the green lamp will light and NX 4 is ready but the CO2 detector will have a heating time of 30 minutes before it works The sensitivity of the three gas detectors must be adjusted before the NX 4 is ready for use When this is done the sensitivity is adjusted only when needed or if you are entering a new climate zone or season of the year Sensitivity adjustment Let the NX 4 be powered for an hour or more Turn the sensitivity knob for the Gas sensor up to the point the alarm triggers Then turn the knob down two scale marks or more from the point the alarm trigged Repeat this procedure for all three sensibility adjustments Readjust the sensitivity when entering a new climate zone or season of the year or if needed otherwise e When first installed or out of use for a long time readjust the sensitivity after a day or two Many people in a small space will normally require less sensitivity because of generally poorer air quality Too high sensitivity setting will increase the risk of unwanted alarm Very low sensitivity setting turned all the way down will not totally disable the alarm but a higher density of gas is required to trigger the alarm In general there is no need to set a very high sensitivity NX 4 will react very well to gas anyway Do your own exper
3. 5 p gt D aH Fuse sikring FU2 0 5A The table below shows all the connections and their functions Se the chapter Technical specifications for electrical data Terminal block J1 Propane CO2 sensor input Terminal block J3 Motion detector positive signal 1 5V DC out 1 12V ut 2 GND 2 GND 3 Signal input 3 Signal input active positive Terminal block J2 External outputs Terminal block J4 Motion detector negative signal 1 All gas detectors combined 1 5V out 2 Propane gas separate 2 GND 3 Motion delayed 3 Signal input active low 4 Extra alarm sounder Terminal block J6 Power supply in and lamp output 1 12 24V input Power supply 2 GND 3 12 24 V out to lamps NB The external signal outputs are unfused and will be destroyed if overloaded Users manual NX 4b Page 7 Basic wiring The illustration shows the power supply and propane CO2 detector connected to the unit The power line is shown with a 15 Amp fuse but smaller fuse can be sufficient if not outside mounted lamps are used and connected directly to NX 4 without relay More about this in the chapter Installation nd II Fuse sikring 15A Propane CO2 detector NX 4 main unit 12 24V Different types of wire can occur When there is referred to color Red brown it means one of the colors not both Wiring external motion detectors Connect motion detectors type NX M2 to
4. All the built in functions in the NX 4 will provide an added insurance against these hazards You might look at NX 4 as your electronic night watch Motion detectors are optional Users manual NX 4b Page 2 What functions does NX 4 have 1 Warning of narcosis gases Alarms many toxic gases with anesthetic or suffocative effect on humans The four sensors will together cover a very wide range of known and unknown gases Two of the sensors are located in the main unit to detect light gases and two are located low in the external unit to detect heavy gases like propane CO2 and other narcosis gases Many of these gases will in best case in medium concentrations make you sleep very heavy If you wake up you may act unconcerned to robbery In stronger concentrations gas is life threatening NX 4 will sound the alarm long before these gases reaches dangerous concentrations If outside lamps are connected to NX 4 they will flash when the Gas alarm is trigged This will help to attract attention from people near by 2 Warning of propane butane gas This sensor is located in the external sensor unit and is installed by the floor in order to detect the heavy propane gas as early as possible This sensor is also very sensitive for hydrogen from over charged batteries 3 Warning of fire The Gas smoke sensor detects smoke by sensing the CO gas generated from the fire It also detects many other pollutions ex
5. If the best location is too far from the bed to hear the alarm install an extra alarm sounder by the bedside A logical place to install NX 4 is beside the electrical distribution center often located above the door in motor homes or at the wardrobe locker in caravans At these locations you often get easy access to electricity To make the installation easy it is highly recommended to install NX 4 on a panel or locker that has access for the wiring from behind Also keep in mind tat the external Propane CO2 sensor also shall be installed near by In general the location of NX 4 is not critical in order to detect gas Attachment Remove the four screws retaining the front of the NX 4 enclosure Attach NX 4 to the wall with two screws trough the holes shown Drill holes for the wires trough the wall in the slots in the enclosure If the wires shall not go trough the wall drill holes in the side of the NX 4 enclosure When all wires are connected reinstall the front Be careful not to bend the red indicator lamps in _ the process attachment holes Install the external Propane CO2 sensor approximately 10 20 cm above the floor The location is not critical Attach it by removing the protective film on the double sided tape or put a screw through the lower part of the enclosure Route the wire to the NX 4 unit preferably behind a panel inside a locker or inside the door gasket Power supply If external outside lamps are no
6. detectors are used they have to be cleaned on regular basis Clean with a cloth and mild soap water Avoid flushing directly at the detectors Users manual NX 4b Page 10 Technical specifications NX 4 Operating voltage 11 30V DC Power requirements 2W approx 140mA at 12V and 70mA at 24V Relay output for external lamps J6 pin3 Max 10A load Operating temperature 10 30 C External alarm outputs All alarm outputs are active as long as NX 4 is alarming gt Combined output for all J2 pin 1 Active low Max load approx 0 4A each 47k pull up gas detectors resistor Low level lt 1V Separate output for the J2 pin2 Active low Max load approx 0 4A each 47k pull up propane detector resistor Low level lt 1V gt Output for delayed motion J2 pin3 Active low Max load approx 0 4A each 47k pull up resistor Low level lt 1V Output for extra alarm J2 pin4 12V approx 10 15mA max load Volume adjustable sounder Active low analog output Motion detector inputs 12V output in 12V systems J3 pin 10 12V max approx 200mA load 12V output in 24V systems J3 pin 12V max approx 50mA load SV output in J4 pin 1 5V max approx 50mA load Current limited by a 10 12 24Vsystems ohm resistor in series Signal input positive J3 pin3 3 5 30V positive signal Approx 20k input imp Signal input negative J4 pin3 Active below 1
7. 5V Approx 20k input imp Delay time at stage 2 for the motion Approx 6 30 sec provided the signal is constant from detector alarm detectors Adjustable with internal potentiometer Dimensions L W H 143x82x38mm Weight 210g With Propane CO2 detector connected but without any other external equipment NX M2 motion detectors power consumption can be neglected To visualize the power consumption of NX 4 a 12V 70 Ah battery will be emptied in 7 weeks if used only at night Connection terminals overview Connector J1 Propane sensor Connector J3 Motion detectors with positive signal 1 Red brown 5V 1 12V out 2 Green GND Ground 2 GND Ground 3 White Signal 3 Signal input active high positive Connector J2 External outputs Connector J4 Motion detectors with negative signal 1 All gas detectors combined 1 5V out 2 Propane gas separately 2 GND Ground 3 Motion delayed 3 Signal input active low negative 4 External alarm sounder Connector J6 Power input and lamp output 1 12 24V Power supply 2 GND Ground 3 12 24 V output to external lamps Users manual NX 4b Page 11 CE Approval NX 4 meets the following standards Immunity EN 50082 2 Emission EN 50081 1 Safety NX 4 is made as a safety aid device It can t guaranty safety If NX 4 shall be used in environments where NX 4 shall provide vital safety alone special requirements apply Consult the ma
8. Nor Tronix User s manual and installation instruction NX 4b x NX 4 Motion Vol Personal Safety System os Gas smoke and motion Oia Delayed Instant detection alarm Gas O Alarm ready Heating Propane CO2 3 Sens ON Nor Tronix Norway vl Sens rN vi Gas Smoke Sens oN i OFF via t CE Personal Safety System for mobile homes Alarm for gas smoke and motion Motion detectors optional Rev 13b Page 1 Users manual NX 4b Introduction Thank you for purchasing a NX 4 security system Since your and others safety may relay on proper function of this product we ask you to carefully read this manual so you can fully understand how to use it how it works and how to install it It is not very complicated Table of contents Whatis NX intended forn nemenin a ated lees oe E E E Pause wasnt 2 1 Warning Of narCOSiS BASES racapein ape reaa E A EAER AEE ETERA EARE 3 2 Warning Of PropAane Dutan Qas pene eciiieri iia aAa A AEE aAA aS EAA EAEri AE ri aaa 3 Bs Warmingof fire necndoni s e a a e a A AA 3 4o Warning Of perons nearDy ieser ia A T AA AA a EN E AE Aaa 3 What eases do s th NX A d tect assitir te e eie e a a eii 3 How to use the NXA nncs iacent e a EER A EE E REEE EES 4 How to test the NX Arrien a N E T E dy E E TEE 5 False alarms soseri E A E a Janeen es asa went 5 Tnstall tioNesns ine a a ATE E E ETEA E AAE O ERNE 6 Connec ton arnee r gaea e kame a r
9. er Adjusting the sensitivity for the Motion Detectors Users manual NX 4b Page 4 How to test the NX 4 Test shall be performer regularly and always after a long period of storage Turn up the sensitivity adjustment knobs just until the alarm sounds and back again At this time also note how much you have to turn up the sensitivity up to trigger the alarm This shall normally be 2 3 scale marks Repeat this procedure for all three sensitivity adjustment knobs The CO2 detector located in the external low mounted sensor housing is tested by blowing directly at the sensor with a few deep breaths You can use a flexible straw or tube to make it easier for the breath to hit the sensor The CO2 content in your breath is just enough to trigger the alarm Remember that the CO2 detector has 30 minutes warm up time before it can be tested The CO2 detector has automatic sensitivity adjustment and will not be tested or affected by the Propane CO2 sensitivity adjustment knob Propane and CO2 alarm is indicated with the same lamp on NX 4 but you can distinguish the two by different sound and flash pattern CO2 gives an uneven pulsating tone and a flashing lamp all other gases gives even pulsating tone and constant light in the indicator lamp on NX 4 A more reliable test is to apply real gas When NX 4 has been powered for a while hold an open bottle of alcohol in front of NX 4 and blow over the bottle against NX 4 This should give Gas and
10. haust and bad air quality in general This detector may alarm even if no smoke is evident This is in most cases because of poor ventilation 4 Warning of persons nearby NX 4 can be equipped with outside mounted motion detectors option to detect persons close to the vehicle Occasional by passers will not create an alarm but if motion persists in the alarm zone for certain amount of time the indoor alarm will sound One detector on each side will alarm if a person walks around the vehicle but not if someone just passes by Connection of external equipment NX 4 has several external alarm outputs for connection of equipment like additional alarm sounder forwarding of alarm signals to a cellular phone alarm sender external flood lights propane gas shut off valve and so on What gases does the NX 4 detect NX 4 has four different gas detectors Each detector has a specific target gas but they all will also overlap each other to a certain extent Together they will detect most gases that are toxic anesthetic explosive or suffocative Two of the sensors are located in the external low mounted Propane CO2 sensor housing NX 4 Main unit Eksterne Propan CO2 sensor Gas sensor Gas smoke sensor Propane sensor CO2 sensor Toluene Hydrogen Propane butane CO2 Ethanol Ethanol Hydrogen Hydrogen sulfide Propane butane Ethanol Amonia CO Hydrogen Methane Users manual NX 4b Page 3 How to use the NX 4
11. ia e ea en a ea date et S 7 Basie WHN ig a paisa eaa a a neta a a a a gan So a a E a 8 Wiring external motion detectors 4 3 doxcatscacciuds dpacseataus tesuosdatagouzeced sees cueeceta ean Bebe 8 Adjusting the sensitivity for the motion detectors 2 0 eee eeeseeceeneeceseeeceeneeceeeeecssneeeeneeeeeaeeeenae 9 Connection of external outside Lights o scsccccciveccecdacassiausageacaasncecasa se deacdaawnsatennedeadeanvenaseebedeeedenes 9 Connecting external lamps with extra relay ccciiiscc Seccdecasscesdkcesonsecdenweddacosecsdndsecessacstocsetanscensss 9 Connecting extraalarmi soundet nan ee Saisie vases i onda Bante a ins 10 Connection of extra outputs with relay eee ceesscecssncecssececeeccecssecececeecseeeecseeeeeseeeeseeeenaeeees 10 IAIN ATIC Cvs cae hidinen ies ostesd ea a heat cans coed fuse ae cee seta al cea E wi Meas cat te oe 10 Technical specifications NXA eenia nae Ea eae a ens eas 11 COnMECHOM pO CV V W ooo os ccc e aaea kas E aoa acouses a EEEa N E aes 11 CE Approval isrener e a ea a e e o na nay aE oisg 12 Safety enn E n O E E a a a a a anG 12 Ma a n E 12 LVS acs sa hace a A a pestene an ea gas Uma cheeses aoe a sane goes 12 What is NX 4 intended for NX 4 is a personal safety alarm system primarily intended for use in mobile homes where health and life can be endangered if you are attacked with narcosis gas by robbers gas leakage from your own gas apparatus fire or unknown persons which may be robbers close to the vehicle
12. iments to see how sensitive you want the alarm to be The CO2 detector has fixed sensitivity and is not affected by the Propane CO2 sensitivity knob The COz sensor is connected to the Propane sensor input so high CO2 concentrations will flash the Propane CO2 lamp and alarm with an uneven pulsating tone Any other gas will give constant light in even pulsating tone and light the respective lamp This way there will always be possible to determine witch sensor that triggered the alarm If outside mounted motion detectors are connected The motion detectors have two stages The first stage is triggered immediately when motion is detected No alarm will sound but the Instant lamp and outside light will light if outside lamp is connected The next stage is delayed and gives an audible inside alarm if motion persists in the detection zone If you are at a safe place where people normally pas by you don t want an audible alarm when outside motion is detected Turn down the volume knob for Motion all the way or something in between if you want a discreet alarm if motion is detected outside If outside lamp is connected it is useful to leave the NX 4 powered in order to make a welcome light for your selves when coming home in the dark Automatic outside lamps also have a frightening effect on burglars The delay or sensitivity is adjustable with the Motion detector sensitivity adjustment knob inside the NX 4 see the chapt
13. nder can be desired if the NX 4 is located far away from the bed or if you have a hearing damage Almost any 12V type of sounder consuming no more than 10 15mA will work also use 12V types in 24V circuits When you are adjusting the volume at the outside detector alarm the volume at the extra sounder also is adjusted Buzer lydgiver Connection of external outputs with relay The external outputs are signal outputs with limited current capacity Extra relay must in most cases be used This example shows how to connect a powerful siren The same circuit can be used for all outputs at terminal block J2 The outputs can be combined by directly connecting them together at J2 Se the chapter Technical specifications for more information about the electrical characteristics in Alarm horn Fuse sikring 15A Maintenance No particularly maintenance is required but regularly readjusting of the gas detector sensitivity is recommended This will ensure proper function and avoid false alarms Regularly do a full function test as described in the chapter How to test NX 4 If NX 4 is used constantly we recommend sending the unit for service and possible sensor replacement after approximately 6 years If NX 4 has been exposed to high air humidity or left OFF for a longer period of time it may be required to leave it ON for a day or two before you readjust the sensitivity and doing a quick function test If outside motion
14. nufacturer for information Warranty 1 year from the date of purchase The warranty cover faults related to manufacturing The warranty does not cover damages by incorrect connection use or normal wear Service If your NX 4 needs service consult your dealer Remember to provide an exact fault description Manufacturer Nor Tronix Norway www nor tronix no Your dealer Nor Tronix Users manual NX 4b Page 12
15. oid false alarms from animals sunlight warm winds occasional by passers and so on Connection of external outside lights You can connect this output to an already existing outside lamp with a wire directly from NX 4 to the lamp without any fuse or switch in between The lamp will automatically be turned on by NX 4 when powered or manually with the existing light switch NX 4 is not damaged if you supply current in to the lamp output You can also connect this output to the hazard lights or parking lights if desired Maximum load is approximately 100W if extra relay is not used Suitable lamps can be outdoor lamps for motor homes or caravans working lights for tractors extra lights for cars backing lamps and so on See more about wire gauge and fuse size requirements in the chapter Installation power supply Jord Gnd II Fuse sikring 15A 12 24V Connecting external lamps with extra relay If you want to connect more lamps requiring more current than NX 4 can deliver directly approx 100W an extra relay can be used With an extra relay you also take load away from NX 4 so you can supply NX 4 from a low capacity circuit This can in many cases simplify the installation if NX 4 is already connected to a circuit Fuse sikring without the capacity to 15A supply the lamps Jord Gnd Fuse sikring Users manual NX 4b Page 9 Connecting additional alarm sounder Extra alarm sou
16. rm will sound constantly and outside lamps light if installed The motion detectors reacts on everything hotter than the background as long as it moves That includes animals sunlight behind a branch moving in the wind warm gusts and humans This will cause the light to come on if equipped but no alarm will sound at this point If the motion in the detection zone persists for a while the alarm will sound This delay will in most cases eliminate false alarms but if false alarms still occur you can reduce the sensitivity More detectors create more false detections and often requires lower sensitivity setting False detections lights the outside light but that is not considered a problem Also see the chapter Adjusting the sensitivity for the motion detectors Users manual NX 4b Page 5 Installation Location Install the NX 4 main unit approximately in the height of your head in a free and open place in the living area where it is easy to reach Do not install it inside a locker NX 4 will react on alcohol so avoid placing NX 4 close to a cellaret if possible NX 4 will react on spent air human breath with alcohol perfume and human wind so if the ventilation is poor this may create false alarms Therefore install NX 4 at an open location where such gases are thinned out before they reach NX 4 It is not recommended to install NX 4 too close to a bed and absolutely not in a small closed sleeping compartment
17. t used NX 4 can be powered from any circuit without any noticeable power capacity because NX 4 consumes very little power 2W If outside lamps are connected directly to NX 4 the power must be taken from a circuit with larger capacity than the already existing load and the extra lamps together Alternatively install a relay for the lamps in order to reduce the power requirement to the NX 4 unit An alternative to heavy gauge wires to NX 4 If Outside lamps are connected the fuse inside NX 4 for external lamps must be smaller than the fuse on the circuit it is powered from This way the NX 4 will keep on working as a gas alarm even if the outside lamps are short circuited and the fuse blows Change the existing 10A fuse with a smaller one if the power of the lamps are considerable less than this In motor homes preferably power NX 4 from a circuit that is turned off when the main switch is off Two Propane sensors Some motor homes has double deck floor If desired NX 4 can be equipped with two propane sensors connected in parallel One in the living area and one below the floor Users manual NX 4b Page 6 Connection All wire terminal blocks are referred to as J1 J2 J3 and so on Each J block has numbered pins The illustration below shows the NX 4 internals when the front is removed Also note the location of the internal fuses Fuse sikring Motion bevegelse J1 9 FU1 10A Sensitivity f lsomhet H r LEP ey
18. terminal block J3 Many detectors can be connected in parallel Terminal block J4 is for detectors with active high positive signal Se the chapter Technical specifications for more information I you want to totally disable the motion detector function not only the alarm sound that you can turn off on the NX 4 main unit Yellow you can install an Green Blue external switch on the power cable to the motion detectors J4 pin 1 Different types of wire can occur When there is referred to color Red brown it means one of the colors not both Bevegelse folsomhet Motion sensitivity Users manual NX 4b Page 8 Adjusting the sensitivity for the motion detectors The sensitivity for the motion detectors can be adjusted to your needs Normally the mid position of the adjustment wheel is a good starting point if you have one or two detectors The adjustment wheel is yellow and located inside the NX 4 unit If more than two detectors are used lower sensitivity may be desired If you are experiencing false alarms turn down the sensitivity More info in chapter False alarms Maximum sensitivity is when the knob is turned fully clockwise and the opposite Do your own test of the sensitivity by walking into the detection area and see how long it takes before the alarm reacts A good starting pint is about 30 seconds If you are standing still you are invisible to the detectors Do not set it too sensitive to av