Home
USER MANUAL
Contents
1. Important This user manual does not explain how to operate your fan coil unit You can only operate your fan coil unit by means of a controller Therefore the operating instructions are included in the controller box Keep this user manual close to hand It may come in handy later The original documentation is written in English All other languages are translations of the original documentation User manual DAIKIN FWG Fan coil units 4PW65029 1A 05 2011 Before operating 1 3 1 Meaning of warnings and symbols An overview of the types that are available Warnings in this manual are classified according to their severity and Decoration panel Identification code Description probability of happening i Decoration panel BYCQ140CW1 Decoration panel for Danger Indicates an imminently hazardous situation standard the fan coil unit with A which if not avoided will result in death or serious injury normal sealing colour Decoration panel BYCQ140CW1W Decoration panel for Warning Indicates a potentially hazardous situation which white the fan coil unit with N if not avoided could result in death or serious injury white sealings Mandatory equipment Each fan coil unit must be connected to at Caution Indicates a potentially hazardous situation which least one of the listed controllers gt if not avoided may result in minor or moderate injury Controllers Identification code Description Electronic remote BRC7
2. company 5 Solve problems with your fan coil unit When your fan coil unit does not function well you can try to solve any problem with the corrective actions in this chapter If the problem persists or is not addressed in this chapter contact your installer or service company Your fan coil unit does not function If your fan coil unit does not function Check If yes Has the fan coil unit been Switch the fan coil unit ON switched OFF Is there a power failure Restore the power supply Has the circuit breaker fuse Contact your installer or service been tripped company Your fan coil unit does not cool or heat well If your fan coil unit does not cool or heat well Check If yes Is there an obstacle near the air Remove the obstacle inlet or air outlet Clean your fan coil unit 6 Dispose of your fan coil unit Your fan coil unit was designed to be environment friendly DAIKIN has complied with the standards for environmentally friendly disposal This means that you have to dispose of your fan coil unit in accordance with the applicable legislation By ensuring this product is disposed of correctly you help to prevent potential negative consequences for the environment and human health EE Fig 6 1 WEEE symbol Your fan coil unit is categorized as an electrical and electronic product It is marked with the symbol illustrated in figure WEEE symbol on page 4 This symbol means that your fan coil u
3. B V1 FW Water fan coil unit C Subclass Cassette C 3x3 06 Total cooling capacity kW B Major model change 7 Minor model change T Coil type T 2 pipe F 4 pipe V1 1 phase 50 Hz 220 240 V B Produced in Europe The following models are available B FWC06 07 08 09B7TV1B 2 pipe fan coil units have a single circuit heat exchanger The device can be used for either cooling or heating B FWC06 07 08 09B7FV1B 4 pipe fan coil units have a double circuit heat exchanger The units can be connected to both cooling and heating systems Use this type if you have a separate source for cooling and for heating 1 3 About this document This document is a user manual It is written for the person who owns or operates this fan coil unit It provides information on NW the product itself Introduction on page 1 B what you should do before you operating the fan coil unit Before operating on page 2 B what you should do for optimal operation of your fan coil unit Tips for optimal operation on page 3 B how you should clean your fan coil unit Clean your fan coil unit on page 4 B what you should do when there is a problem with your fan coil unit Solve problems with your fan coil unit on page 4 B how you should dispose of your fan coil unit Dispose of your fan coil unit on page 4 terms that have been used in this user manual that may need clarification Glossary on page 4
4. DAIKIN USER MANUAL FWC06B7TV1B FWCO7B7TV1B FWC08B7TV1B FWC09B7TV1B FWC06B7FV1B FWCO7B7FV1B FWC08B7FV1B FWC09B7FV1B Introduction Table of contents 1 Introduction 1 1 About fan coil units 1 2 About your fan coil unit 1 3 About this document 1 3 1 Meaning of warnings and symbols 2 Before operating 2 1 Check that you have all equipment and the corresponding documentation N gt gt mi ND N 2 2 Read the safety precautions Tips for optimal operation Clean your fan coil unit Solve problems with your fan coil unit Dispose of your fan coil unit Glossary N OU R O a A aA B WW w Annex Handover of the installation to 5 the user 1 Introduction Thank you for purchasing this DAIKIN fan coil unit 1 1 About fan coil units A fan coil unit provides heating and or cooling to individual spaces It creates a comfortable environment in both commercial and residential applications Fan coil units are widely used for the air conditioning of offices hotels and houses The main components of fan coil units are B afan B a heat exchanger The heat exchanger receives hot or cold water from a heating or cooling source DAIKIN offers a wide range of fan coil units for both concealed and exposed applications Contact your installer for a list of related products 1 2 About your fan coil unit You have purchased the FWC model fan coil unit The model identification code means FW C 06
5. F532F Wireless remote Notice Indicates situations that may result in damage to controller wireless controller to control equipment or property cooling and heating each fan coil unit independently with cooling and heating Information This symbol identifies useful information but functionality no hazardous situation warnings Remark B Refer tothe VRV system in the Some types of danger are represented by special symbols operation manual Electric current The function auto fan speed is not available Electronic remote BRC7F533F Wireless remote Danger of burning or scalding controller wireless controller to control cooling only each fan coil unit independently with Other symbols cooling functionality only This part of the manual is intended for the installer of this Remark product B Refer tothe VRV system in the operation manual i The function Before operating auto fan speed is not available a gt gt 2 Electronic remote BRC315D7 Wired remote 2 1 Check that you have all equipment and the controller wired controller to control corresponding documentation each fan coil unit independently with Extra required equipment cooling and heating The fan coil unit must be used in combination with additional functionality equipment Central remote DCS302CA51 Remote controller for This equipment must be bought separately and is required to operate controller centralized control of the fan coil uni
6. he installation manual Please note that the installer can only install your fan coil unit NW inaconcealed ceiling B in perfect condition Precautions before operating Only operate your fan coil unit after it has been installed by a licensed installer Verify that the installation has been completed by checking that the Annex Handover of the installation to the user on page 5 has been filled in completely Precautions for operating Only operate a fan coil unit if you are fully alert and aware Fan coil units are not intended for use by persons with reduced physical sensory or mental capabilities or those who have not used the fan coil unit before including children When these persons want to use the fan coil unit the person responsible for their safety must supervise them or instruct them in the use of the fan coil unit Supervise children to ensure that they do not play with the fan coil unit If you feel unsure about operating the fan coil unit contact your installer for advice and information wo Tips for optimal operation Adjust the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using the timer setting options B Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds B Ventilate the room regularly Using the unit for long period
7. m 4PW65029 1A 05 2011
8. nit should be recycled and not disposed of in unsorted municipal waste To dispose of your fan coil unit contact your installer The installer and qualified instances will HW dismantle the fan coil unit B re use recycle and recover parts of the fan coil unit AN Warning Never dismantle the fan coil unit yourself DAIKIN and the environment thank you 7 Glossary Applicable All international European national and local legislation directives laws regulations and or codes which are relevant and applicable for a certain product or domain Circuit Safety device used in electrical installations to breaker fuse prevent electric shock Are any doors and windows Close doors and windows PA Installer Technical skilled person who is qualified to install fan coil units and other DAIKIN products Is the fan coil unit running at low Select medium speed or high speed speed Are the air filters dirty Contact your installer or service Service Qualified company which can perform or company company coordinate the required service to the fan coil unit Your fan coil unit leaks water Shut down the unit and contact your installer or service company FWC DAIKIN User manual Fan coil units 4PW65029 1A 05 2011 Annex Handover of the installation to the user Annex Handover of the installation to the user Tick Y when checked T Ensure that the user has a printed version of the user To be filled in by the installe
9. r once the test run is finished and the fan manual and the installation manual and ask him her to coil unit s operate s properly keep it for future reference ick Y Hes hiaten se Explain the user how to properly operate the system and Explain to the user what system is installed on site what he she has to do in case of problems Complete the ID cards below for each installed fan coil unit This information may be useful for the user in future servicing Fill in the place of installation room the model I Show the user what maintenance jobs he she has to do in name see nameplate of the fan coil unit and list the relation to cleaning the unit optional equipment which is installed Date Signature Fan coil unit 1 Fan coil unit 2 Place of Place of installation installation De ee PE 7 Optional equipment Optional eguipment Fan coil unit 3 Fan coil unit 4 Place of Place of installation installation Optional equipment Optional equipment Fan coil unit 5 Fan coil unit 6 Place of Place of installation installation Modalname Modelname Optional equipment Optional equipment Fan coil unit 7 Fan coil unit 8 Place of Place of installation installation Modalname Modelname Optional equipment Optional equipment User manual DAIKIN FWC 5 Fan coil units 4PW65029 1A 05 2011 Copyright 2010 Daikin DAIKIN EUROPE N V Zandvoordestraat 300 B 8400 Oostende Belgiu
10. s of time requires attentive ventilation of the room B Keep doors and windows closed when the unit is in operation If the doors and windows remain open air will flow out and decrease the effect of cooling and heating B Never place objects near the air inlet and the air outlet of the unit It may reduce the effectiveness or cause the unit to stop Turn off the main power supply switch when not using the fan coil unit for long periods of time Electricity is consumed so long as the switch is on Turn off the main power supply switch in order to save energy Fully use the function of air flow direction adjustment if available As cold air gathers on the floor and warm air gathers against the ceiling it is recommended to set the air flow direction during cooling operation parallel to the ceiling and to set it downwards during heating operation Be sure that you do not direct air flow on to the inhabitants of the room User manual 3 DAIKIN FWG Fan coil units 4PW65029 1A 05 2011 4 Clean your fan coil unit To clean the outside of your fan coil unit 1 Switch off the fan coil unit 2 Clean the outside of the fan coil unit with a soft cloth Notice O Do not pour any liquid on the fan coil unit This could damage the components inside it Never clean your fan coil unit with NW any aggressive chemical solvent HW water hotter than 50 C For maintenance of your fan coil unit contact your installer or service
11. t safely and comfortably all connected units Overview of additional equipment required Intelligent touch DCS601C51C Advanced remote m decoration panel controller controller for B controller centralized control of all connected units Unified ON OFF DCS301BA51 Remote controller to controller switch all connected units ON or OFF FWO DAIKIN User manual Fan coil units 4PW65029 1A 05 2011 Before operating Extra optional equipment Optionally you can buy additional equipment for your fan coil unit to extend the life of your product increase the level of automation and improve its ease of use Overview of the optional additional equipment for your fan coil unit An overview of the types that are available NW air handling options sensor timer valves electronic circuits PCB Air handling options Identification code KDBHQ55C140 Blocking parts to close one or more air outlets of the fan coil unit Long life KAFP551K160 High quality filter replacement filter KDDQ55C 140 Kit which can be connected to the ventilation system in order to supply fresh air to the fan coil unit Description Sealing member of air discharge outlet Fresh air intake kit Sensor Identification code Description Remote temperature KRCS01 4 sensor Replacement sensor to measure temperature remotely from a location other than that in which the controller is installed Identification code Descrip
12. tion DST301BA51 Controller with schedule timing functionality Identification code Description EKMV2C09B7 Electronic 2 way valve to control the water supply EKRP1C11 EKMV3C09B7 Electronic 3 way valve to control the water supply EKRP1C11 Description Schedule timer Valves 2 way valve ON OFF type 3 way valve ON OFF type Identification code EKRP1C11 Electronic circuits Valve control PCB Mandatory electronic circuit when 2 way or 3 way valve is used Optional PCB for EKFCMBCB7 Electronic circuit with Modbus connection Modbus interface connections Wiring adaptor for KRP4A A 53 Electronic circuit with electrical appendices KRP2A52 additional connections for external input output signals 2 2 Read the safety precautions Your fan coil unit is built to meet all recognized technical requirements Operate your fan coil unit according to the instructions in the included documentation and the manuals of the additional equipment e g controller Any other usage is considered as improper and may result in property damage serious physical injuries or death Resulting damage caused by improper use is the sole responsibility of the user and the user alone To prevent any risk B carefully read the safety precautions NW operate your fan coil unit according to the documentation Precautions for installation The installer should install and connect your fan coil unit as described in t