Contents

1. 4mm that is conductive to reducing the line voltage drop Recommended 30A with 10mm cable Check weather the installation sites compliance with the relevant safety requirements Please avoid the damp dusty there is a place flammable explosive and corrosive gases use the controller to install e amp communication port the other end to connect to the host computer Demolition To prevent accidents please order the demolition of solar panels battery and load disconnect with controller Note Battery polarity will not damage the controller but you will have a load equipment security risk 9 Install the controller into a fixed vertical plane See section 5 of the pore size and pore spacing In order to ensure a good thermal control conditions please set aside each 10cm below the controller space As shown on the right connect the 1 Load 2 Battery and 3 Solar Panel to the controller according to the order of 1 2 3 Pay attention to the load battery solar panel and controller of same polarity Put into the external temperature sensor on the left of the controller probe port The temperature sensor should be similar space with battery Otherwise the controller will control the parameters of all wrong temperature compensation If you have remote monitoring and control function please insert one end of the included communication wire on the right of the controller JyskSolenerg CM30 12 24V 30A Ladereg
2. on the right shows the values for the HVD voltage When the battery voltage is reach to HVD voltage the controller will cut off the charging circuit to prevent over charging battery Battery voltage drops under the value the charging circuit will be re connected Long press the button gt 5seconds in this interface numbers start flashing that has entered the HVD setup interface you can use the key to adjust the parameter After long press the keyii gt 5seconds to exit parameter setting interface the controller will save the settings 3 11 View and set Load Working Mode As shown on the right is Load working mode interface different values represent different load working patterns 24h said Normal Mode in case of no fault state of the load is always in power saa eal orm 1h 23h said Light Control with Time Control Mode Load power after dark and close the load according A wu to the timer setting Oh said Light Control Mode Load power after dark turn off the load after drawn Long press the button gt 5seconds in this interface numbers start flashing that has entered the Load Working Mode setup interface you can use the key to adjust the parameter After long press the keyi gt 5seconds to exit parameter setting interface the controller will save the settings o JyskSolenergi CM30 12 24V 30A Laderegulator 4 Common Fault and Handling LVD Protection and Treatment Screen display as shown in t
3. value will back to zero 3 7 View the Accumulated discharging power Ah by Load and back to zero As shown on the right display the accumulated discharging power for loads Total ampere hour long press the button E more than 5 seconds the value will back to zero 3 8 View and set the Low Voltage Disconnection Protection As shown on the right shows the values for the LVD protection voltage When the battery voltage is lower than protection voltage the controller will disconnect the load circuit to prevent battery over discharge Long press the button gt 5seconds in this interface numbers start flashing that has entered the LVD setup interface you can use the key to adjust the parameter After long press the keyii gt 5seconds to exit parameter setting interface the controller will save the settings 3 9 View and set the Low Voltage Reconnection As shown on the right shows the values for the LVR voltage Under the LVD protection in the controller when the battery voltage is restored to the higher voltage than LVR voltage the controller will re connect the load circuit Long press the button gt 5seconds in this interface numbers start flashing that has entered the LVR setup interface you can use the key A to adjust the parameter After long press the keyi gt 5seconds to exit parameter setting interface the controller will save the settings 3 10 View and set the High Voltage Disconnection As shown
4. CM30 12 24V 30A Laderegulator Intelligent Solar Charge Controller User s Manual AW CM3024Z Please read this manual carefully before you use this product 1 Product Introduction 2 Installation 3 Operation 4 Common Fault and Handling 5 Technical Data Catalogue 3 4 5 10 11 on 4 JyskSolenergi CM30 12 24V 30A Laderegulator 1 Product Introduction CM series controller is a kind of intelligent multi purpose solar charge and discharge controller The family use the fixed LCD display with a very friendly interface various control parameters can be flexibly set fully meet your various application requirements CM series controller has following features Simple button operation Image of LCD graphic symbol Automatic Identification System Voltage level Intelligent PWM charge mode Automatic Temperature Compensation Adjustable charge discharge control parameters Settable Operating mode of Load Accumulated function of charge and discharge Ampere hours Remote monitoring and control function custom Battery reverse discharge protection Battery Low Voltage Disconnection LVD Battery reverse connection protection Overload Short Circuit Protection Install 2 Installation Solar Charge Remote Controller monitoring and control port Temperature sensor probe port DC Load Ready tools and cables Encourage you to matching the right cables Ensure that the current density lt
5. a Daa ose a ii Da toa nese iii A Operating 5 Rated Voltage 12V 24V 48 10 C 60 C Temperature Open Circuit Storage g Voltage of solar lt 50V lt 100V 30 C 70 C temperature panel Installation cable a Rated Current 20A 30A 20 30A lt 16mm area V Humidit Float Voltage 13 8V 27 6V 55 2V lt 90 no condensation requirements Low Voltage Disconnection LVD 10 7V 21 4V 42 8V 90 mmx188 mmx48 mm Low Voltage Mounting hole 12 5V 25 0V 50 0V 60 mmx178 mm 5 Reconnection LVR spacing ross some lat g v sivmy charging mode PM mode o G o Compensation Notes Model suffix Z represent automatic identify system voltage level T represent controller with remote monitoring e JyskSolenerg
6. he figure that the battery drops below the LVD protection voltage The controller has entered the LCD protection state load circuit has been disconnected Use the solar panels recharge the battery or charger when the battery voltage reaches LVR voltage the controller will resume on the load power supply into the normal working state Overload Protection and Treatment Screen display see the figure and flashing expressed load loop circuit current sustained 6Oseconds than 1 5times rated current the controller has entered into overload protection state After reduce the load press the button to restore power to the load Short Circuit Protection and Treatment Screen display see the figure on the right and flashing expressed there is short circuit on the load loop circuit The controller has enter into Short Circuit Protection state Check the load if there is damage or not if there is cable short circuit or not after trouble shooting short press the button Y for restoration Solar Panel Fault and Treatment Symbol flashing represent the controller was not detected solar panels within 24hours Check if there is a connection from solar panel check if there is an open circuit between solar panels with controller Load Shock Fault Open load if the flashing that indicate the load impulse current is more than twice rated current of the controller The controller is restarting the load in action many timers do 5 Technical Dat
7. n This is the main interface Use the button could in turn visit the following parameters interface If that interface could be set long press the button gt 5seconds numbers start flashing To enter the parameter setting interface set out the parameter interface after long press the button again The numbers stops flashing 3 1 Battery Voltage of View As shown on the right displays the value for current battery voltage This interface based interface displays charge status discharge status battery capacity and battery voltage 3 2 The load on off control View the interface in the battery voltage could be used key We On off the load In other interface the key there is no such feature e JyskSolenergi CM30 12 24V 30A Laderegulator 3 3 Environment Temperature of View As shown on the right displays the ambient temperature of the controller the value used for temperature compensation on LVD function The sensor must be plug in before using the controller 3 4 Solar Panel charging current of View As shown on the right display the value of charging current from solar panel 3 5 Load discharging current of View As shown on the right display the value of discharging current for Loads 3 6 View the Accumulated charging power Ah by solar panel and back to zero As shown on the right display the accumulated charging power from solar panel Total ampere hour long press the button E more than 5 seconds the
8. ulator 3 Operation 1 Description of LCD graphic symbol Stop powered Status for Loads Stop the battery charging gt Power to the load status the load circuit without current Bulk charging the battery gt The load circuit with current za Float charging the battery gt 4 gt A Load The system is working correctly Mf Solar Panel mn rN mn rN wo The system is not working properly C Load sensor control Cekal Battery charge capacity instruction Load timer control Battery 2 Description of Button Function E Interface loop switch button use the button to cycle between pages in each switch cycle sequence shown in figure 1 A Adjustment of parameters plus buttons In addition at the state in the parameter view long press the button more than 5 seconds all parameter to restore factory setting Y Adjustment of parameters minus button In addition in the main interface click this button to switch the load g TD lt Battery Voltage Battery Solar Panel Load Accumulated main interface temperature charge current discharge current charging power Ah LOAD ON LOAD ON 53 V 5 r Aa Load working High Voltage Low voltage Low Voltage Accumulated Mode Disconnection HVD Reconnection LVR Disconnection LVD Discharging power Ah Figure 1 3 View and set the parameters The controller will default entry battery voltage interface after correct power o