INSTALLATION INSTRUCTIONS AND USER GUIDE
Contents
1. D eco fluic 4 ER e c oO SS 3044 C CB SCHEME E INTERTIA ELECTRIC RADIATOR RKS4Hi RKS4L RKS6Hi RKS6L RKS8Hi RKS8L RKS10Hi RKS10OL RKS12Hi RKS12L RKS14Hi RKS14L SS es Please read these instructions before installing or using this appliance for the first time 1 WARNING The warranty of the heater will not cover any damage caused by non observance of any of these instructions This guide must be kept and given to any new owner This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be made by children without supervision Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance Children of less than 3 years should be kept away unless continuously supervised CAUTION Some parts of th
2. Press the key to select different operation modes or to set the system time Time Settings To perform correct programming it is necessary to set the system time days of the week To set the system time the unit should be in OFF position with a symbol C on the display Press the mod key Week days indication will start blinking ae iT 7J i 7J With or keys select present day and press OK to store Proceed to time settings JJ 6 3 6 73 7J Set the hour with or keysand press OK to store Repeat the operation to set minutes Cn 6 7J Press the ON OFF key to exit ON OFF The heater may operate only in one of two conditions ON or OFF OFF When the unit is in OFF symbol is displayed together with premises temperature value O ON To switch on the unit to ON mode press the key CA Last operation mode before the unit had been switched off will be displayed Press the same key to switch off the unit and pass to OFF Apply preferably this form to switch off the unit instead of the main switch in order to avoid setting the system time constantly Different operation modes may be applied To switch from one mode to another press the mod key after no less than two seconds between each change AUTOMATIC INTERNAL PROGRAMMER MODE PET TT ELLE PL TTT LEE EEL ELLE LLL Oh 2 4 6 810 12 14 16 1820 22 24 PERMANENT a I FROST PROTECTION 2 x a MODE PERMANENT ECO
3. Contact the after sale service displayed d2 or d3 message is displayed Sensor wrong connection Contact the after sale service dEF message is displayed CPL connection trouble Contact the after sale service Time settings are lost There was electric supply shortage or the unit had been disconnected by the main switch The keyboard does not respond If the bloc message is displayed the thermal radiator keyboard is locked Hold two central keys for several seconds to unlock the keyboard 10 SPECIFICATIONS Models Hi L RKS4Hi RKS6Hi RKS8HIi RKS10Hi RKS12Hi RKS1I4Hi RKS4L RKS6L RKS8L RKS10L RKS12L RKS14L ELEMENTS 4 6 8 10 12 14 4 6 8 10 12 14 LENGTH cm 41 5 57 5 73 5 89 5 105 5 121 5 41 5 57 5 73 5 89 5 105 5 121 5 WIDTH cm 10 plus 2 5 cm separation from the wall HEIGHT cm 58 WEIGHT 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg POWER 500W 750W 1000W 1250W 1600W 2000W 500w 750W 1000W 1250W 1600W 2000W ISOLATION CLASS II VOLTAGE 220 240V 2 PILOT WIRE BLACK THERMAL LIMITER THERMOSTAT PCB DIGITAL CONTROL RKS L DISPLAY HEATING ELEMENT TEMPERATURE SENSOR 4 MAIN SWITCH NEUTRAL BLUE LIVE BROWN 220 240V LIVE BROWN THERMOSTAT PCB NEUTRAL BLUE 2 THERMAL LIMITER PILOTE WIRE BLACK RKS Hi WN TEMPERATURE SENSOR MAIN SWITCH CABLE A NEUTRAL BLUE LIVE BROWN S PILOT WIRE BLACK
4. LIVE BROWN 220 240V Connect the black wire marked Fil Pilote to the signal wire when available Do not connect this wire to any EARTH lead Connect L and N wires to a fix wall socket or to an appropriate plug WITHOUT EARTH 11 WARNING In order to avoid overheating do not cover the heater The symbol on the product or in its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product These instructions are only valid in the EU member states ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk Manufactured by ELNUR S A Madrid Spain www elnur global com export elnur global com Management System International Certifications 7 Net J SSS E kk B Fai ESAI h T feit C ISO 9001 ISO 14001 As a part of the policy of continuous pr
5. NOMICAL MODE AUTOMATIC REMOTE PROGRAMMER MODE PERMANENT COMFORT MODE PERMANENT COMFORT MODE In permanent comfort mode the unit maintains constantly the set point temperature It is possible to modify COMFORT set point temperature in 0 5 C steps by pressing the 6 3 6 7J keys T or Temperature range is from 5 to 30 C When the heater consumes power ON message is displayed cory Pressing the will momentarily display the premises temperature PERMANENT ECONOMICAL MODE In economical mode the unit maintains all the time the ECONOMICAL set point temperature Originally the economical set point temperature is the comfort set point temperature reduced by 3 5 C See menu 1 of CONFIGURATION paragraph to modify the reduction or even to select economic set point temperature cory Pressing the key displays momentarily the premises temperature PERMANENT FROST PROTECTION MODE In permanent frost protection mode the unit will operate when the premises temperature decreases lower than 7 C FELI In this mode pressing the i key displays momentarily the premises temperature AUTOMATIC INTERNAL PROGRAMMER MODE In this mode the unit performs commands of the internal programmer Programming By default the program Comfort fro 8h to 22h is applied for all days of the week To modify the program press the PROG key in this mode or in OFF mode Select the temperature level for the first time interv
6. RIER In AUTOMATIC mode it is possible to control the heater operation from a programmer with PLC Power Line Carrier or from a load controler with PLC TO ASSOCIATE the heater switch the PLC programmer or the PLC load controller to the association mode see corresponding manual Press the mod button for more than five seconds and after that press the mod button twice the display will show CP Keep the mod button pressed The message CP will start blinking Release the mod button and press it again The display will show En To store press the mod key TO DISASSOCIATE the heater press the mod button for more than five seconds and after that press the mod button twice the display will show CP Keep the mod button pressed for 60 seconds until the display will show An To store press the mod key MODELS RKSL CONNECT DISCONNECT Main switch All the models are equipped with the switch on the back surface for general heater disconnection After a long term disconnection it is necessary to reset the unit system time These four keys perform different operations depending on the message of the LCD display Press two central buttons at a time for several seconds to lock unlock the keyboard ON OFF key Press the key to switch from OFF to OPERATION Operation mode key Gabarrom
7. al of the day 1 by pressing one of the following keys si Pressing displays two segments indicating COMFORT temperature Pressing display one segment indicating ECONOMICAL temperature Pressing Ke does not display any segment indicating FROST PROTECTION temperature After programming all 24 intervals for the DAY 1 press OK to pass to the DAY 2 of the week and repeat the procedure Fast Programming To copy the complete program from one day to another hold the OK key for 3 seconds agge ANE ERaRer CANNAE Oh 2 4 6 8 10 12 14 16 1820 22 24 X PROG C 1 2 3 4 5 6 7 I I I I l L I I Oh 2 4 6 8 10 12 14 16 1820 22 24 OOK PROG KEY Press the key to modify the program SAND GLASS KEY Press the key to adjust the specified temperature for certain determined time 7 7J 7 7J By keys or adjust the set point 1 3 temperature and store by pressing the OK 6 7J 74 3 Adjust the time required by keys or and 11 7J press OK tostore 1 7J To go back to the previous settings press again the OK key AUTOMATIC REMOTE PROGRAMMER MODE 8 10 12 14 16 1820 22 24 x PROG TD INFO KEY Press the key to see the premises temperature or set point temperature according to configurations of MENU 5 ABSENCE KEY Press the key to switch on the Frost Protection mode from 1 day to 365 days iT 3 Adjust the amount of absence days by keys t6 7J
8. authorize ECO value modification press and hold the key until it displays the tt 7 message and store pressing OK In such a way when selecting the permanent economical mode it 6 7J iT 3 will be possible to assign any temperature with or _ key displayed at selection of permanent economical mode Selection range will start from 4 5 C to the comfort set point temperature Menu 2 Correction of temperature measures If there is a difference between an external thermometer indication and the temperature displayed by the unit in menu 2 it is possible to influence on the sensor in order to balance the difference 5 C to 5 C in 0 1 C steps 7 7J 6 7J 73 7J To modify press the keys or afterpress the OK key and proceed with the next setting O O OGO O hey gt 10 sec Pir LILIC I ok NORWOOD NO oh WN numero de menu Menu 3 Configuration of CPL This menu allows associating the unit to the remote CPL programmer connected to the same power grid 7 3 In menu 3 press the for 5 seconds CPL message will start blinking Switch the CPL programmer remote control desk to the association mode see 7 7J corresponding manual Press shortly the key EnrE message displays on the screen and then CPL message confirming the association 74 7J Press OK key to proceed with the following setting Menu 4 Backlight time settings Adjustable backlight is availab
9. cal regulations The heater is fitted with a flexible cable size 3 x 1 00 mm for electrical connection It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater This appliance must be earthed The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm If the flexible supply cord is damaged it must be replaced by a repair workshop recognised by the manufacturer in order to avoid hazard All models are supplied with an electrical interrupt cut out This will switch off the heater if for any reason it overheats Should the cut out operate turn the heater off and remove the cause for the overheating The cut out will be reset automatically The presence in the air of particles of smoke dust and other pollutants could in time discolour the walls and surfaces around the heater 2 INSTALLATION INSTRUCTIONS Shelf Open the package and check that it is the correct model and it is in good condition To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material as furniture curtains etc The rest of clearances required to maintain are indicated on the following figure Minimum 15cm Closest object to the left a Closest end object to the right end Pos
10. ing ON output condition ADJUSTMENT OF THE SET POINT TEMPERATURE COMFORT set point temperature may be adjusted from 7 C to 30 C in 0 5 C steps decrease COMFORT Gc barron set point temperature iT 3 7 7J Pressing the keys or the set point temperature is increased reduced respectively After three seconds if no other key is pushed the selected value is stored in memory The set point temperature in ECONOMIC mode is the COMFORT setting temperature reduced by 3 5 C The setting temperature in FROST PROTECTION mode is 7 C and it is constant CORRECTION OF TEMPERATURE MEASURES If there is a difference between temperature values on an external thermometer and the temperature displayed by the unit it is possible to change the sensor settings in order to balance the difference 5 C to 5 C in 0 5 C steps 13 7 In order to make changes hold the mod key for more than five seconds and after that with buttons 66 7J or increase or decrease the correction to 0 5 C respectively Press the mod key to store the correction in memory and proceed with the next setting BLUE BACKLIGHT Pressing any key the display will illuminate with a soft blue color After certain time if no other keys are pushed the display backlight will turn off It is also possible to adjust the display backlight time Hold the mod key during five seconds After the correction if required
11. is product can become very hot and cause burns Particular attention has to be given where children and vulnerable people are present Should the heater be moved and reinstalled it is essential that the work is carried out by a competent electrician The use of these heaters is forbidden in any area where there is a presence of gases explosives or inflammable objects Neither the connecting cable nor any other object must come into contact with the hot unit Check that the voltage shown on the rating plate on the heater is the same as the voltage of the supply to which connection is to be made WARNING In order to avoid overheating do not cover the heater Do not use this heater to dry clothes The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the appliance They also protect the heater from overheating therefore it is essential that at no time are they covered This heater should be switched off at the isolating switch before any repair work is carried out This action should also be taken during the times of the year when heat is not required The thermal radiator should not be installed just below an electrical socket or in front of a socket outlet The appliance must be installed in such a way that switches and other control devices cannot be touched by a person using a bath or shower The installation must be carried out in accordance with the current electri
12. ition and fix the brackets at the correct Minimum distance from the floor It is possible to use 15cm the radiator as measuring unit by positioning it on two polyester package elements and placing two supports above as indicated on the figure Minimum 10cm Minimum 25cm Control panel side N il be Mark the fixing points on ee Cie s o the wall using a pencil The studs and screws to attach the supports through the two fixing holes are in the accessories bag in the square brackets and Hang the unit on the hooks of the brackets perform corresponding By turning the screw the metallic square will bores go downwards retaining the heater Repeat this on the other bracket F3 3 USING THE THERMAL RADIATOR MODELS RKSHi Main switch All models are equipped with one switch on the back surface allowing the heater disconnection ON OFF key Push the button to switch on off the heater Also you may lock unlock the keyboard by maintaining it for several seconds OPERATION MODE KEY Press the key to select operation mode permanent COMFORT Key a i A Press the key to increase the aeit E COMFORT set point AUTOMATIC modes temperature cG JJ Key Press the key to LCD DISPLAY LCD display shows the information related to the heater operation Example of the heater permanent COMFORT mode 1 Neater is OFF Set point temperature is 20 5 C show
13. le from 0 to 225 seconds in 15 seconds steps 90 seconds by default rT 7J 7 7J i 7J To modify press T or keys then press the OK to store and proceed with the next setting Menu 5 Selection of temperature display in AUTO operation mode 1 Permanent display of the premises temperature 0 Permanent display of the set point temperature 6 3 6 7J i 7J To modify press or keys then press the OK to store and exit the configuration mode 4 CLEANING AND MAINTENANCE gt 5 sec The radiators do not precise any special maintenance providing thermal comfort during large periods Clean dust with a dry soft cloth only when the unit is disconnected and cold Do not use solvents or abrasive products for cleaning After the heating season disconnect the radiator with the switch located on the back surface of the radiator This thermal radiator has been manufactured under an assured quality system using environment friendly processes Please take the heaters to a clean point once their useful life is finished in order to recycle their materials in the right way 5 TROUBLESHOOTING The thermal radiator does not heat Check the heater or the air inlets are not covered The room does not reach the Check the selected temperature is in accordance with the desired temperature Maybe the room needs required temperature more heating power 9 9 C 99 9 C message is Sensor wrong connection
14. oduct improvement Elnur reserves the right to alter specifications without notice INSTALLATION INSTRUCTIONS AND USER GUIDE WEB VERSION
15. of the thermostat see previous paragraph a value from 0 to 90 6 7J 6 3 seconds will be displayed It may be modified in 15 seconds steps by and _ keys If 0 value is selected the display backlight will be off permanently To store press the mod key OPERATION MODES By the mod key different functions or operation modes may be selected PERMANENT COMFORT mode PERMANENT ECONOMICAL PERMANENT AUTOMATIC mode In this mode TL U y mode The set point temperature is FROST PROTECTION mode programs from the input command Push thekey or ifitis reduced by 3 5 C The set point temperature is cable pilot wire are performed required to modify comfort set 7 C and it is constant point temperature KEYBOARD LOCK 6 7J In every operation mode it is possible to lock the keyboard by holding the ON OFF key for more than 7 seconds a 7J When the keyboard is locked if any button is pressed the display will show Lo message and the unit will not respond iT 7J To unlock the keyboard press the ON OFF button for more than 7 seconds A gt sec OPERATION WITH A PILOT WIRE PROGRAMMER It is possible to control the heater operation from a remote pilot wire programmer in AUTOMATIC mode Pilot wire programmer orders for OFF and FROST PROTECTION are prior and independent from the operation mode selected in the heater OPERATION WITH A PROGRAMMER WITH POWER LINE CARRIER OR A LOAD CONTROLER WITH POWER LINE CAR
16. or and store with OK key To disconnect the absence mode press again the 66 7J OK key r OK In this mode the unit follows commands from the remote control desk or remote programmer If there aren t any the unit operates in permanent COMFORT mode KEYBOARD LOCK iT 7J 7 7J En every operation mode it is possible to lock the keyboard pressing central and keys for several seconds With the keyboard locked pressing any key displays bloc message and the unit will not respond With the keyboard locked the unit may receive commands from the IR remote control 7 7J 7 7J To unlock the keyboard press simultaneously central keys T and for several seconds CONFIGURATION It is possible to configure various parameters of the unit 6 7J In OFF mode press for 10 seconds ON OFF key to enter the first configuration menu It is necessary to pass through five menus to exit the configuration The Menu number is displayed above in the right part of the display Menu 1 Adjusting the ECO set point temperature By default the Economic set point temperature value is equal to comfort temperature value reduced by 3 5 C The reduction value may be modified from 0 a 10 C in 0 5 C steps 7J 7J g 74 7J For this purpose modify the value with the keys andpress OK to store and pass to the next setting ECO set point temperature value may be stored independently from the CONFORT temperature value 1i 7J To