1. Healthcare OWNERS UAL SERENA amp SOFIA RISER RECLINER ARMCHAIRS 9 SERENA amp SOFIA RISER RECLINER ARMCHAIRS da 4S z Introduction The Serena is supplied with single or double motors The single motor chair is available in a range of 3 different coloured fabrics mocha cinnamon oatmeal and a wine coloured vinyl The dual motor chair is available in a range of 3 different fabrics mocha cinnamon oatmeal The sofia is available with a single motor and 3 different fabrics mocha cinnamon oatmeal The battery back up system on the Serena Sofia enables the chair to be raised and lowered at least 3 times in the event ofa power failure The Serena Sofia are CE marked and are flame retardant in accordance with BS 7176 2007 Medium Dual Motor Chair shown right MODELS AVAILABLE Model No Description Colour 920B1C5 SERENA fabric CINNAMON 920B2C5 SERENA fabric MOCHA 920B3C5 SERENA fabric OATMEAL 920S1C5 SERENA fabric CINNAMON 920S2C5 SERENA fabric MOCHA 920S3C5 SERENA fabric OATMEAL 920W1C5 SERENA fabric CINNAMON 920W2C5 SERENA fabric MOCHA 920W3C5 SERENA fabric OATMEAL 920W4C5 SERENA vinyl WINE 922B1C5 SOFIA fabric CINNAMON SOFIA fabric MOCHA SOFIA fabric BUTTON OATMEAL 923W1C5 SERENA fabric CINNAMON 923W2C5 SERENA fabric MOCHA 923W3C5 SERENA fabric OATMEAL 922B2C5 922B3C5 SERENA amp SOFIA RISER RECLINER ARMCHAIRS days On rec
2. and must be disposed of according to national regulations Specification Serena single motor Serena double motor Max User Weight 160 Kg 25 st 160 Kg 25 st 115 Kg 18 st Overall Width 95cm 37 1 2 96 5cm 38 78cm 30 3 4 Overall Depth Upright 90cm 35 1 2 78 75cm 31 84cm 33 Overall Depth Reclined 172cm 67 3 4 185cm 73 155cm 61 Overall Height 120cm 47 1 4 109cm 43 101cm 40 Seat Width 53cm 20 3 4 53 25cm 21 45cm 17 3 4 Seat Depth 50cm 19 3 4 46cm 18 48cm 19 Seat Height 47cm 18 1 2 49 5cm 19 1 2 46cm 18 Dealer Stamp D N N1 069 03 C email info dayshealthcare com
3. eipt of your Riser Recliner Armchair you will be in possession of the following parts Seat Base Backrest Transformer Handset Head and Arm Covers amp Batteries Assembly Instructions l Working at the back of the chair untie cable ties and connect lead to the Transformer fig 1 2 Remove cover and connect batteries to Transformer fig 2 Batteries can be found in side pocket of chair 3 Plug into mains fig 3 Your Days Healthcare Lift amp Recline Chair operates on standard house hold electric 4 Remove handset from side pocket 5 Before fitting backrest recline the chair via the handset 6 Clip backrest onto base ensuring both receivers lock into the brackets fig 4 0 TIMOTION mu supor O THMOTION sonor supy bdl ON I3P0W amoa Ygoow QO Part No fig 4 fig 3 Operation To allow for sufficient room for the backrest to recline the chair must be placed at least 46cm 18 at the rear from a wall or surrounding furniture Your Lift Recline Chair is operated by a hand control located on the right hand side of the chair The handset for the single motor chair has 2 buttons fig 5 One will lower and recline the backrest and the other will raise and incline the seat The chair will only move when the selected button is continuously pressed To stop in any position simply release the button To recline the chair press the down button and hold until the backrest is
4. in the required position To raise the chair press the up button and hold until the seat is in the raised position The handset for the dual motor chair has 5 buttons Note If Riser Recliner does not operate check thoroughly that the above assembly instructions have been administered fig 5 SERENA amp SOFIA RISER RECLINER ARMCHAIRS days Caution When raising the chair seat always keep your feet in contact with the ground Do not operate the chair unless you are certain there are no children or pets anywhere near or at the rear of the chair Do not allow any liq uids to come in contact with the hand control and any spilt drinks or fluids on the seat are to be immediately removed to avoid possible contact with the electrics underneath Remove power supply immediately Battery Back Up Supply In the event of a mains power supply failure your chair will automatically be operated from the battery supply system The batteries should be fitted to the transformer They will not be connected at time of shipping from Days Healthcare Please ensure that the batteries are connected to the transformer before use and that they remain connected Replacement batteries can be sourced from your local shop or supermarket and we advise you to replace them every two years or immediately after use to ensure adequate supply of power in the event of a mains supply failure Maintenance and Cleaning Your chair does not require any routine or
5. regular service In the event of a fault please contact your Supplier or local Days Healthcare Agent The motor and folding mechanism requires no cleaning The upholstery can be cleaned with light sponging of warm soapy water or domestic upholstery cleaner Do not use bleach base cleaners to avoid discolouration Warranty The Days Healthcare range of Lift Recline Chairs are warranted for two years from date of purchase against faulty workmanship or materials on the frame mechanics and electric controls Note Wear and tear on the upholstery is not covered Please contact your Supplier Dealer should a fault occur The warranty does not extend to the consequential costs resulting from fault clearance in particular freight and travel costs loss of earnings expenses etc The manufacturer will not accept responsibility for any damages or injury caused by misuse or non observance of the instructions set out above Disposing of the Riser Recliner Armchair The Chair consists of metal and plastic components electronic components electrical cables and batteries Disposal of the individual materials must be carried out in accordance with environmental and disposal regu lations in the relevant country and may only take place after the riser recliner chair has been dismantled To dismantle the chair and to separate and dispose of the materials you would be advised to hand it over to your specialist dealer Batteries may not be disposed of in domestic waste