DCREG MODBUS-RTU USER GUIDE

image

Contents

1. NOTE The node address cannot be changed when the module is operating but is detected only when the equipment is powered on 4 2 TERMINATION The end nodes of a Profibus DP network must have terminations avoiding to interfere with the bus line To do so the Profibus DP module is equipped with a termination switch For the first or the last converter in the network the switch must be ON otherwise for intermediate converters it must be OFF N B If a connector with an external termination is used the switch must be OFF 6 7 DCREG 16B0221B3 2 Interface DCREG via Profibus DP ELETTRONICASANTERNO 4 3 INDICATIONS The module is provided with four LEDs installed on its front part and with one LED assembled on the control board and which is used for debugging operations 4 3 1 Front LEDs 1 Not used 2 On Line 3 Off Line 4 Fieldbus diagnostics The LED functions are described in the table below LED 2 Indicates that the converter is On Line on the Fieldbus On Line Green the module is On Line data exchange is allowed Off the module is On Line 3 Indicates that the converter is Off Line on the Fieldbus Off Line Red The module is Off Line no data exchanged allowed Off The module is not Off Line 4 Indicates that errors occurred on the Fieldbus side Fieldbus Flashing red at 1 Hz Error while configurating the message length set while initializing the diagnostics module does not match with the me
2. e 16B0301B3 DCREG MODBUS RTU USER GUIDE DCREG INTERFACE VIA MODBUS RTU Agg 03 05 04 R 00 7 Versione D3 09 lta Iano e presente manuale costituisce parte integrante ed essenziale del prodotto Leggere attentamente le avvertenze contenute in esso in quanto forniscono importanti indicazioni riguardanti la sicurezza d uso e di manutenzione e Questa macchina dovr essere destinata al solo uso per il quale stata espressamente concepita Ogni altro uso da considerarsi improprio e quindi pericoloso Il Costruttore non pu essere considerato responsabile per eventuali danni causati da usi impropri erronei ed irragionevoli e L Elettronica Santerno si ritiene responsabile della macchina nella sua configurazione originale e Qualsiasi intervento che alteri la struttura o il ciclo di funzionamento della macchina deve essere eseguito od autorizzato dall Ufficio Tecnico della Elettronica Santerno e L Elettronica Santerno non si ritiene responsabile delle conseguenze derivate dall utilizzo di ricambi non originali L Elettronica Santerno si riserva di apportare eventuali modifiche tecniche sul presente manuale e sulla macchina senza obbligo di preavviso Qualora vengano rilevati errori tipografici o di altro genere le correzioni saranno incluse nelle nuove versioni del manuale e L Elettronica Santerno si ritiene responsabile delle informazioni riportate nella versione originale del manuale in lingua Italiana Propriet
3. eate this interface an optional module must be installed on the DCREG see Module description The converter thus becomes a slave node from which a Profibus DP master can read and on which it can write The DCREG will never start a communication towards other nodes but will only answer incoming commands Via PROFIBUS DP you can read the parameters mentioned in the following From master to DCREG write the parameters mentioned in the following From DCREG to master 1 1 SUPPORTED PROTOCOL AND FUNCTIONS Fieldbus type PROFIBUS DP EN 50170 DIN 19245 Protocol version 1 10 Automatic baudrate detection should not be configured by the user within the range 9 6 kbi t s 12Mbi t s The following values are supported 9 6 kbit s 19 2 kbit s 45 45 kbit s 93 75 kbit s 187 5 kbit s 500 kbit s 1 5 Mbit s 3 Mbit s 6 Mbit s 12 Mbit s 1 1 1 Physical interface Means of transmission Profibus bus line type A or B as specified in EN50170 Topology Master Slave communication Fieldbus Connector 9 pin female DSUB Cable copper shielded pair Insulation the bus is galvanically separated from the rest of the electronics by means of a DC DC converter The signals of the bus line A and line B are insulated through optocouplers Profibus DP communication ASIC Siemens SPC3 chip 1 1 2 Configuration and indications On board bus termination switch LED indications ON line OFF l
4. ine diagnostics for the Fieldbus 1 1 3 GSD File Each device in a Profibus DP network is associated with a GSD file containing all the information needed about the device This file is used by the network configuration programme during configuration of the network To get the most recent version of the GSD file contact Elettronica Santerno directly 3 7 16B0221B3 Interface DCREG via Profibus DP 2 ELETTRONICASANTERNO 2 PARAMETER EXCHANGE DCREG The following table shows the parameters of the DCREG exchanged through PROFIBUS DP In each of the following are listed 1 the number and the name of the parameter its meaning 3 its range 4 its unit of measure shown on the display 5 2 the ratio between the value inside the DCREG exchanged via Profibus DP and the physical value represented shown on the display A NONE N B DCREG2 DCREG4 R 01 Software Vers D3 09 2 1 FROM MASTER TO DCREG 1 Name 16 FBRref M019 AnOut M020 AnOut2 M022 MDO PO50 Ilim1A 51 Ilim1B not used M031 FBDigln 2 2 FROM 1 Name temp M001 nFdbk MOOA larm M006 Varm Anln1 M011 Anln2 12 Anln3 4 7 2 Configuration Speed voltage reference from PROFIBUS Analog output 1 on terminal 8 Analog output 2 terminal 10 Digital output state First voltage limit bridge A First voltage limit bridge B Digital input state from PROFIBUS DCREG TO MASTER 2 Meaning N
5. ote C Speed voltage feedback Armour current Armature voltage Auxiliary analog input 1 at terminals 11 and 13 Auxiliary analog input 2 aot terminal 17 Auxiliary analog input 3 at terminal 19 3 Range 100 100 10 10 10 10 00000xxxb 1111 boxb 0 300 0 300 00000000b 11111111b Unless otherwise specified each parameter is exchanged as integer with sign at 16 bit between 32768 and 32767 For further information on parameter configuration refer to the OPERATION MANUAL 15P0059A3 A Unit of 5 Ratio measure 100 3FFFh V FFFh V FFFh Note A 9 1 9 1 Note DCREG 16B0221B3 Z Interface DCREG via Profibus DP ELETTRONICASANTERNO M026 EFreq Encoder frequency Note A Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 MDOS MDOI MDO2 MDO3 MDO4 VLLL Note B Bit O ENABLE Bit 1 START Bit 2 Bit 3 MDI2 Bit 4 MDI3 Bit 5 MDIA Bit 6 MDI5 Bit 7 MDI Note C The two 8 bit variables AlarmNumber and Led are mapped inside the variable temp Its meaning is the following high part low part Led Allarm Nr AlarmNumber has the following meaning Drive OK if AlarmNumber 0 Alarm AlarmNumber if AlarmNumber x 33 Warning AlarmNumber 33 if AlarmNumber gt 33 Led indicates the state of the LED s on the remotable keyboard with the following map Bit O RUN Bit 1 FORWARD Bit 2 LOC SEQ Bit 3 BRAKE Bit 4 REF Bit 5 REVERSE Bit 6 LOC REM Bi
6. riservata Riproduzione vietata L Elettronica Santerno tutela i propri diritti sui disegni e sui cataloghi a termine di legge ELETTRONICA SANTERNO Elettronica Santerno S p A Via G Di Vittorio 3 40020 Casalfiumanese Bo Italia Tel 39 0542 668611 Fax 39 0542 668622 Assistenza Clienti Tel 39 0542 668610 Fax 39 0542 668623 Ufficio Vendite Tel 39 0542 668611 Fax 39 0542 668600 16B0221B3 DCREG Interface DCREG via Profibus DP 4 ELETTRONICASANTERNO INDEX 1 1 SUPPORTED PROTOCOL AND FUNCTIONS uu 1211 Physical interac ue eie teet Ee ren eroe eI e tese eta ee veux eL M eque tia E EUREN EUN 1 1 2 Configuration and indications eene eren n nnnm eren enne nennen eren enn INE eS EE 2 PARAMETER EXCHANGE m M H 2 T FROM MASTER DCREG 5e A AIR Re R A E LI 2 2 FROM DCREG TO MASTER 3 ALARM A028 COMMUNICATION INTERRUPTED nennen 4 PROFIBUS DP MODULE 1 eplyiesiscP nta ALD EC EE 4 3 INDIGATIONS do Front CEL E 4 3 2 LED on the Control Board r bee e e HRS ER SEEN A RES EE 2 7 16B0221B3 Z Interface DCREG via Profibus DP ELETTRONICASANTERNO DCREG 1 COMMUNICATION FEATURES This manual describes how to interface a DCREG slave converter with an intelligent outside control unit master via PROFIBUS DP In order to cr
7. ssage length set while initializing the network Flashing red at 2 Hz Error in the parameter data the length and or contents of the data set while initializing the module do not match with the length and or contents of the data set while initializing the network Flashing red at 4 Hz Error while initializing the Profibus communication ASIC Off No diagnostic message provided 4 3 2 LED on the Control Board The LED located on the control board is a Watchdog LED indicating the state of the module according to the table below Unspecified internal error or module operating in bootloader mode 1 Hz RAM fault 2 Hz ASIC or FLASH fault 4 Hz DPRAM fault Green 2 Hz Module not initialized 1 Hz Module initialized and operating 7 7
8. t 7 LIMIT Note D DriveSize identifies the size of the armature circuit of DCREG within the range 10 3500 A as can be seen on the starting page of the remotable keyboard 5 7 16B0221B3 DCREG Interface DCREG via Profibus DP 2 3 ALARM A028 COMMUNICATION INTERRUPTED This alarm will come into action if the DCREG does not receive any valid message via PROFIBUS DP within the timeout which can be set using parameter C143 A028Delay This alarm can be inhibited using parameter C159 A028lnhibit 4 PROFIBUS DP MODULE Optional Profibus DP module must be used for the Profibus link Insert it into connector CN11 of control board 5800 DCREG control and screw it to the three columns No particular setting is required see settings for rotary switches and termination switch below 4 1 NODE ADDRESS Before using the Profibus DP module select the node address using the two rotary selector switches installed on the module they allow to select addresses in decimal format ranging from 1 to 99 The selector switch on the left is used to select the tens while the selector switch on the right is used to select the units Example Address Set left selector switch x 10 Set right selector switch x 1 Alternatively the node address can be selected through the mailbox telegram NOTE FB_SET NODE ADDRESS allowing to select a node address from 1 to 125 included For more information please contact Elettronica Santerno SpA