Home
Intel® Server System R1000GZ/GL Product Family Quick Installation
Contents
1. Status LED Diagnostic des ID LED S Serial A ir sie wa T O e amp 888 8888 A NY Riser Slot 1 a E RMMA Lite ii ll daa Internal USB E Storage Upgrade Key SCU0 0 3 a 0 TPM Connector oe Caley L SCU1 4 7 Module f f Connector cn a Serial UL R IPMB di E HooLeD HSBPIC SATA O SAS Modul SATA 1 o Riser Slot 2 Or Main Power 2 Main Power 1 i ses ower Optional Optional 12V Power 1 12V Power 2 Connector N mj fm D D CPU 1 Socket OJ 0 System Front Panel vides ont Ranett System EEL System ODD SSD Power Connector 3 Fan 3 System Fan 6 pA M y A EY a Chassis Intrusion System Fan 5 EL Pont ye walle System Front Panel EE p J Fan4 LCP OQ For server systems integrated with Intel Server Board S2600GZ only See your Intel Serve
2. To activate the port SCU1 4 7 on the server board a proper Intel RAID C600 Upgrade Key must be installed For instructions see Intel RAID C600 Upgrade Key Installation Guide O M O Intel Integrated RAID Module O ee This page is intentionally left blank G31060 004
3. 1 and engage screw threads by giving it two rotations and stop Do not fully tighten N ee lt Y ae O DN Proceed to screw 2 and engage screw threads by giving it two rotations and stop Similarly engage screws 3 and 4 Repeat steps C and D by giving each screw two rotations each time until ms each screw is lightly tightened up to ZB a maximum of 8 inch lbs torque NOTE Heatsink styles may vary Install Memory Modules Continued Memory Configurations and Population Order Intel Server Board 2600GZ i yt it E For best performance a minimum of four DIMMs per CPU is recommended populated in the blue slot of each memory channel In a single processor configuration always populate A1 DIMM first In a dual processor configuration always populate A1 DIMM first for CPU1 and E1 DIMM first for CPU2 Note For additional memory configurations see the Service Guide on the Intel Server Deployment amp Management DVD that accompanied your Intel Server System or go to http www intel com support Memory sizing and configuration is supported only for qualified DIMMs approved by Intel For a list of supported memory go to nttp serverconfigurator intel com Install Memory Modules Continued To Install DIMMs LA Open both DIMM socket levers A Note location of alignme
4. bezel if needed torque to 7 9in Ibs LA Lock the right end of the front bezel to the rack handle Recessed Finishing Up Before installing your operating system you Add in Card Slots must finish your system installation make 1 0 connections and plug in the power cord s 1 Verify the system top cover is installed 2 Install the server into the rack using the instructions Intel RMM4_ Intel I O provided with the rack mounting kit 4st Power ond Power NIC Port Module 3 Connect your USB keyboard mouse video and other Supply Supply icy NIC3 Video USB optional O cables devices as shown Module Module Ports Then connect the power cora s Network Software Bios Drivers and Operating System Installation A Update the System Software Update the System BIOS ME Firmware BMC Firmware and FRU amp SDR data using the latest versions posted for this product at http www intel com support NOTE The FRUSDR utility must be run for full platform management functionality B Configure your RAID Controller If using a RAID card use the instructions provided with the RAID controller If using on board RAID you must activate RAID in the BIOS setup See the nte Server System R1000GZ GL Service Guide for more information C Install your Operating System Use the in
5. front of the module H into the back panel slot and align the 1 0 Module over the three stand offs I A IN 1 9 Carefully press down on the 1 0 a lt module to engage connectors LO gt Ss ARA F SS I D Secure the module with the three screws as shown NOTE If included remember to install the EMI shield 1 Install Intel RAID Smart Battery optional LA Locate the BBU bracket inside the chassis Align the tabs on the plastic battery holder with mounting holes on the BBU bracket Slide the plastic battery holder toward the rear of the system until the tabs engage with the mounting holes in the BBU bracket 1 O Install Second Power Supply Module optional Use the finger hole to remove the Insert the power supply module into the power Power Supply Removal filler panel supply cage and push all the way until it clicks into place Pull out the module from the chassis by holding the handle while pressing the green latch in the direction shown 19 Install Bezel optional 20 Install the Top Cover NOTE Install the rack handles before installing the bezel Place the top cover on the system and slide towards the front of the chassis until the recessed front edge is fully engaged Install the three screws at the front and torque to Vit alia 7 9in lbs Then install the screw at the back and B Push in the left side of the bezel until it clicks into place Lock the
6. system e The CPU 1 processor CPU heatsink must be installed first The CPU 2 heatsink must be installed at all times with or without a processor installed e Memory Slot population requirements NOTE Specified memory slots can be populated with a DIMM or supplied DIMM Blank Memory population rules apply when installing DIMMs DIMM Population Rules on CPU 1 Install DIMMs in order Channels A B C and D Start with 1 DIMM slot blue on each channel then slot 2 then Slot 3 24 DIMM board Only remove DIMM blanks when populating the slot with a DIMM DIMM Population on CPU 2 Install DIMMs in order Channels E F G and H Start with 1 DIMM slot blue on each channel then slot 2 then Slot 3 24 DIMM board Only remove DIMM blanks when populating the slot with a DIMM The following system configurations require the specific memory slots be populated at all times using a DIMM or supplied DIMM blank System Configuration 8x 2 5 hard drive bay configuration 24 DIMM server board DIMM blanks installed on memory slot 3 for all memory channels e All hard drive bays must be populated Hard drive carriers either can be populated with a hard drive or supplied drive blank e The air duct must be installed at all times e In single power supply configurations the second power supply bay must have the supplied filler blank installed at all times e The system top cover must be installed at all times The only exception to
7. For a complete list of compatible processors heatsinks and memory see server board connections or install components http www intel com support Remove the Top Cover 3 Remove the Air Duct O Remove the four screws Remove the air duct by Slide cover back and lift upward lifting straight up Remove Processor Heatsink s IMPORTANT Before proceeding The heatsink is attached to the server board processor socket with captive fasteners further check your Intel Server System Using a 2 Phillips screwdriver loosen the four screws located on the for disconnected or heatsink corners in a diagonal manner using the following procedure eae oon Using a 2 Phillips screwdriver start with screw 1 and loosen it by may have occurred giving it two rotations and stop IMPORTANT Do not fully loosen during shipping Proceed to screw 2 and loosen it by giving it two rotations and stop Similarly loosen screws 3 and 4 Repeat steps A and B by giving each screw two rotations each time until all screws are loosened 8 Lift the heatsink straight up Eee i y Install the Processor s A Open the Socket Lever B Open the Load Plate Push down the lever and slide away from the socket to O Press the locking lever slightly to raise the release it load plate Repeat step A to release the lever on the other side Open the load plate all the way NOTE Release the levers in the order as Sh
8. Intel Server System R10006Z GL Product Family Quick Installation User s Guide Thank you for buying an Intel Server System The following information will help you assemble your Intel Server System and install components If you are not familiar with ESD Electrostatic Discharge procedures used during system integration see the complete ESD procedures described in your Service Guide This guide and other supporting documents are located on the web at 2 5 hard drive bay system as shown G31060 004 This page is intentionally left blank Table of Contents SYSTEM OE 1 Generalinstallation PrOCeSS Ar ae l LED SO A e eer anererenceenreerrrer 2l REMOVE EN CENO DN CONC mecanica acia l REMOVE Meliana rcarititon tien rene l Remove Processor Heatsink S rar na l Sta OCEAN a kei 3 ias talero cessor Ee It SINK da 4 ASt Memory Module S nino nadas 4 Ee AMES tanteo 5 AAC Bah cirerereeeter en te teem trea lo 7 MN A ante ice eatin eae cathe erie aoe cute chart nce ade tats 7 Remove Add in Card Riser ASSEMDIY u sssssssssssssssssessessssssssesssesssesssssssresssesssessees 7 NavSibea tl ex GI GIS file Grate Gh Sy ceesteneatees a 7 Install Add in Card Riser ASSEMDIY aia 8 NSERIES AAA ESA a eatnan nin O Install Intel 1 0 Expansion Module optional ssssssssssssssssseessseesseessseessees 8 Install Intel RAID C600 Upgrade Key optional e ccoo 8 Install Intel IA 8 Install Second Power Supply Module
9. nt notch Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot Push down firmly on the DIMM until it snaps into place and both levers close IMPORTANT Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot O Install Hard Drives 2 5 Hard Drive Carrier For system with 2 5 hard drive bay only O Remove the drive carrier by pressing the green latch a Install the hard disk drive using the four screws as shown Make sure to unlock the connector end of the drive matches the backplane connector Pull out the black lever and slide the carrier out Remove the four screws from the 2 5 HDD carrier F With the lever open insert the hard disk drive assembly into the chassis then push in the lever to lock it into place D Disengage and remove the plastic drive blank from the HDD carrier 27 TT TE WEA CU MA C VIS VAGA AAA WAS DT L m DE N AA TE n WAA ONO DIAL CNL VISIT WINS TIN V TADA WIND IT WII a Drive O Primary 8 x 2 5 hard drive bay as shown Install Hard Drives Continued 3 5 Hard Drive Carrier For system with 3 5 hard drive bay only E Remove the drive carrier by pressing the green button and opening Remove the four screws securing the HDD interface bracket and remove the lever the HDD interface bracket Slide the carrier out Install the hard disk drive using the same fou
10. optional ec ceomommosmsmm 9 Beeli AE ene e crrnnrtrnrteeit are minnie nt 9 Sia Me nop cat nr ata e te rat E rin eae 9 A A E E A E A 9 SEI e E E E E E ea 10 RETTER Eaa AA A A 11 Tools Required Read all caution and safety Installation and service Observe normal ESD A statements in this document A of this product to be Electrostatic Discharge before performing any of the performed only by procedures during system instructions Also see the ntel qualified service personnel integration to avoid possible Server Board and Server Chassis to avoid risk of injury from damage to server board and or Phillips Safety Information document at electrical shock or energy other components screwdriver http www intel com support hazard motherboards server sb cs 010770 Anti static htm for complete safety information wrist strap Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2012 Intel Corporation All rights reserved Thermal Operation and Configuration Requirements To keep the system operating within supported maximum thermal limits the system must meet the following operating and configuration guidelines e Ambient inlet temperature cannot exceed 35 C and should not remain at this maximum level for long periods of time Doing so may affect long term reliability of the
11. own Install the Processor s continued C Install the Processor Save the f protective cover Q Take the processor out of the box and remove the protective shipping cover Orient the processor with the socket so that the processor cutouts match the four orientation posts on the socket Note location of gold key at corner of processor Install the Processor s continued D Remove the Cover E Close the Load Plate F Latch the Locking Lever Press the cover to Carefully lower the load plate over O Push down the locking lever cal the processor Slide the tip of the lever under the notch in the load plate Make sure the load plate tab engages under the socket lever when fully closed Repeat the steps to latch the locking lever on the other side Save the protective NOTE Latch the levers in the order as shown 6 Install Processor Heatsink s Install Memory Modules CAUTION Do not DDR3 DIMM Memory Identification over tighten fasteners O Remove the protective film on the TIM if present Align heatsink fins to the front and back of the chassis for correct airflow DIMM notch and socket bump must align as shown below Airflow goes from front to back of chassis Each heatsink has four captive fasteners and should be tightened in a diagonal manner using the following procedure Using a 2 Phillips screwdriver start with screw
12. r System R1000GZ GL Service Guide for expanded component and connection information A a System Fan Connection Please find a complete list of accessories and spares at http www intel com support aes System Cabling Diagram For system with 8 x 2 5 hard drive bay Note To activate the port SCU1 4 7 on the server board a proper Intel RAID C600 Upgrade Key must be installed For instructions see Intel RAID C600 Upgrade Key Installation Guide I I I Intel Integrated i 177752 RAID Module iy A i APRA O O 3 E Po Eos Front Panel Front Panel Video System Cabling Diagram For system with 4 x 3 5 hard drive bay Note
13. r screws as shown Make E With the lever open insert the hard disk drive assembly into the chassis sure the connector end of the drive matches the backplane connector B Push in the lever to lock it into place Install 2 5 Hard Drive as option GD Break off the tab onthe AB Install the HDD interface bracket GB Slide the 2 5 HDD into the GD Secure the hard disk drive using HDD interface bracket from top Secure the bracket with bracket to align the screw holes the four screws for 2 5 HDD three screws as shown with the right and left rail ES TEA 7 yA Doc ll LILILILILILILILILILIILILILIL A CITI TTT ITI IO NN PAE A OO A TUL A ACAL EA ASADO gt A ASADO TOTS Drive O Primary 4 x 3 5 hard drive bay as shown 9 Install Optical Drive O Install the plastic guide onto the back Insert the optical drive into chassis opening IMPORTANT NOTE If you do not of the drive and attach with two screws and push all the way until it stops as shown Connect the cables as shown Install the Air Duct Align the two holes on the air duct with the alignment pins on the chassis and install the air duct into place Use care to avoid pinching system cables 1 2 Install Add in Card s Full height PCle Card Shown NOTE Add in card install sequence for low profile add in cards is the same O Remove the filler panel from the add in card slot and remove the screw as shown O Insert
14. structions provided with the RAID controller and with the operating system D Install Operating System Drivers With the operating system running insert the Intel Server Deployment and Management DVD If using a Microsoft Windows operating system the Express Installer will autorun and allow you to select the appropriate drivers to install On other operating systems browse the DVD folders to locate and install the driver files E Install Intel System Management Software optional Download the latest version of the Intel System Management Software from http www intel com go servermanagement and use the instructions provided at that link to install the software Other brands and names may be claimed as the property of others 0 Front Panel Controls and Indicators Standard Control Panel Your system may include one of two front control panel types The features of each are as follows A ID Button with integrated LED F System Status LED B NMI Button Recessed tool required G Power Button with integrated LED C LAN 1 Activity LED H HDD Activity LED D LAN 3 Activity LED LAN 4 Activity LED E System Cold Reset Button J LAN 2 Activity LED BCDE F G Intel Server Board S2600GZ GL Component Layout
15. the add in card until it sits in the riser connector secure the add in card with the screw as shown NOTE Make sure that all empty add in card slots have filler panels installed install a device at this location install the optical device bay filler panel shown below This is required to maintain proper system cooling 1 1 Remove Add in Card Riser Assembly Grasp the riser assembly with both hands and pull up to remove from system Riser Card Connector Install Add in Card Riser Assembly Install Rack Handles Hooks 2 NOTE Rack handles are required to install the Position the riser card edge connector over bezel For detailed instructions see the the server board riser socket and align the SS product Service Guide available on the Intel two hooks of the riser with the slots at the SEED Server Deployment and Management DVD back of the chassis then press straight i down into riser socket NOTE Riser Slot 2 is not functional without having two processors installed 1 5 Install Intel 1 0 Expansion Module 1 6 Install Intel RAID C600 optional Upgrade Key optional amp Squeeze the sides of the 1 0 Locate the white 4 pin key header next to Riser Slot 1 Carefully module bay filler plate and pickup the Intel RAID C600 Upgrade Key Match the Key and pull it away from the chassis connector orientation and press down to install back panel S Fit the
16. this requirement is to hot replace a failed system fan in which case the top cover can be removed for no more than three minutes at a time talled alled to be functional IX O ANO Z Ryo A two processors ins Pa qu LL e Y TU O A al J NJ J Q E aB UN gt ve cad gt ap U e_ aB System Features and Components y Y Z7 Y E S e NERAL A i D ESA Wy VUS EA System Fans x MS 3 Hard Drive Bays Hot Swap Front Control Panel Useful Information e Riser Slot 2 is not funct e The SCUT 4 7 ithout having ional wi requires an In tel RAID C600 Upgrade Key ins por The installation instructions in this section are for common components of Intel Server System R10006Z GL Product Family Minimum Hardware Requirements Preparing the System To avoid integration difficulties and possible board damage your system must meet the following minimum requirements o Observe normal ESD Electrostatic Discharge o Processor procedures Intel Xeon processor E5 2600 product family e Memory Type SS Minimum of one 512MB DDR3 1066 1333 MHz UDIMM or one 1GB DDR3 800 1066 1333 1600 MHz RDIMM Place your Intel Server System on a flat anti static e Hard Disk Drives SATA surface to perform the following integration procedures l Observe ESD procedures before reaching inside to make
Download Pdf Manuals
Related Search
Related Contents
UNAOHM Sony VGN-FS500 Marketing Specifications ARCS®II SYSTEM - Scandec Systemer Samsung SWT50B3P User Manual Journaux 1970-2000 High end elegance 施工・取扱説明書 ひこの取扱説明書をよくお読みの 上、 機械の取扱いをしてくださ い。 り Newstar FPMA-D940 flat panel desk mount Copyright © All rights reserved.
Failed to retrieve file