GSM-Route BRI 3G Installation & User Guide

image

Contents

1. GSM Route BRI 3G Installation amp User Guide m telecom FM 2 4 Safe and Efficient Use Guidelines for Safe Use of the GSM Route BRI 3G Please read this information before connecting the GSM Route BRI 3G The instructions are intended for your safety Please follow these guidelines Recommendations for safe use of the product Do not expose the product to liquid or moisture Do not expose the product to open flames Do not attempt to modify the product Do not use the product near medical equipment without requesting permission from your treating physician or authorised medical staff e Do not use the product when in or around aircraft or areas showing the sign turn off two way radio e Do not use the product in an area where the potential explosive atmosphere exists e The maximum operating ambient temperature of the equipment is 40 C Power Supply Connect the AC power supply adapter only to designated power sources Radio Frequency RF exposure and Specific Absorbsion Rate SAR The GSM Route BRI 3G is a low power radio transmitter and receiver When turned on it emits low levels of radio frequency energy Governments around the world have adopted international safety guidelines ICNIRP International Commission on Non lonizing Radiation Protection and IEEE The Institute of Electrical and Electronic Engineers have developed guidelines to establish the permitted levels of radio wave exposure for the gene
2. telecomem GSM Route BRI 3G Installation amp User Guide Version 3 December 2010 telecomewv GSM Route BRI 3G Installation amp User Guide 1 Contents 1 Contents 2 2 Notices 3 2 1 Pack ge Piu acp CEPT 3 2 2 G aranNteG NORRIS TNT 3 2 DOCUMOENE CONG Oly ss aesekne nue A ihi des Ue ite dediti 3 2 4 Safe and Efficient Use Pe m 4 3 Overview 5 CR A eaten setae 5 mu POWSITESIBDIS heat 5 3 3 Mobile Signal Falluf e cores a a ian 5 54 J SDN SIGiial Pane ec 5 3 9 Power SUD TRIS LIII TIMERE 5 3 60 ua NODE 6 3 7 Safety NStrUC IONS e 6 4 Standard Installation 7 4 1 Siting the GSM Route BRI 3G cece eee eee ee eee eee meme 7 4 2 qoos ReQUIFEO lola 7 4 3 Pr sbnstallabiOl seice aussen Docosas sdb evade saepius diiuessiUsndibe chioaaeigadeiadeds psum M SES 7 4 4 GSM Route BRI 3G Motherboard mme 8 4 5 Locating GSM Route BRI 3G uiiiseesem nin aaa rei 9 4 0 Power LED SEGUENce sesso rkk o ed Ln tI aa RR eC NIB S RE DIR RR D Rn 10 4 7 Connecung the ISDN ous lil 11 4 8 Connecting to ISDN Trunk ports ati 11 4 9 Programming Via a Local Digital Management Centre If Applicable 12 4 10 Programming Using the Unmanaged Local Programmer If Applicable 12 4 11 Testing the GSM Ro ute BRI 3G uode riam to deck over ea Ps Res SER EDU Ru Rasa r
3. amount of wiring steel or metal construction material e on walls with unusually thick masonry e in metal buildings or in rooms with large areas of metal You must NOT e install your GSM Route BRI 3G outdoors e expose the GSM Route BRI 3G to water or moisture i e basements or outbuildings e expose the GSM Route BRI 3G to direct sources of heat or cold e g air conditioning heaters or direct sunlight e cover or place obstructions on or around the unit s antenna e 4 2 Tools Required The minimum tools required to carry out an installation of a single GSM Route BRI 3G is as follows ISDN Test Telephone Screwdriver Power Drill 4 3 Pre Installation Prior to the commencement of installation work check with the customer that 1 the supporting paperwork is correct 2 the ISDN circuit ports detailed on the paperwork is are correct 3 the customer is in agreement with the proposed siting of the GSM Route BRI 3G 4 SIM cards are available for installation GSM Route BRI 3G Installation amp User Guide telecom FM 4 4 GSM Route BRI 3G Motherboard Programming Dam Port Antenna connections SIM Holder 1 GSM Module 2 Daughter Board GSM Module 1 SIM Holder 2 Mains Power Connector NT Port o TE Ports Figure 1 GSM Route BRI 3G Installation amp User Guide m telecom FM 4 5 Locating GSM Route BRI 3G 1 Neatly locate and mount the GSM Route BRI 3G in the agreed position using the fixing
4. template Ensure that the wall is flat and the chassis is not bowed or misaligned 2 Connect Antennae 3 Insert SIM cards into the SIM holders see figure 1 page 8 GSM Route BRI 3G Installation amp User Guide m telecom FM 4 6 Power LED Sequence Power up the unit When power is connected the amber LED 3 will be lit During the first 15 seconds the GSM Route BRI 3G will auto detect if an ISDN circuit is available and what protocol it is set for Point to Point or Point to Multi Point then it will reset the unit with the correct settings When the GSM Module s are connecting to a network its status LEDs 24 amp 25 will produce long flashes 600ms 600 ms On Off If the GSM module has no SIM card inserted its status LEDs 24 or 25 will flash SOS on its associated LED When a GSM module has logged onto a network its status LEDs 24 amp 25 will produce short flashes 75ms 3s On Off If the Basic Rate ISDN interface is activated the status LEDs 20 amp 21 will produce short flashes 75ms 3s On Off When the Terminal Equipment Interface is activated the status LEDs 22 amp 23 will produce short flashes 75ms 3s On Off The signal strength on Module 1 is displayed on LED 18 See signal strength Indication The signal strength on Module 2 is displayed on LED 19 See signal strength Indication LED Indication Status LEDs Signal Strength I ndication Power status Amber LED S During power up LEDs 18 amp 19 will
5. Verify programme with TFM help desk If applicable Force new download by dialing 0001 or 0000 If not managed check programming with Unmanaged local Programmer No Incoming ringing One way transmission Noise Is Heard during calls Check ISDN circuit is live Check respective network The GSM may be too close to other electronic devices Reception over GSM is Poor Check signal strength and location Check aerial installation and positioning Not connecting to GSM trunks when dialing out through PBX Check that they are in the correct trunk group with cyclic hunting Green LEDs 24 amp 25 flash SOS Check SIM card Check SIM is seated correctly in SIM holder Check programming RED LEDs 20 amp 21 not lit Check ISDN circuit is live and connected RED LED 26 flashing on off Check ISDN circuit is live and connected RED LEDs 22 amp 23 not lit Check terminal equipment is connected PBX 14 Wy telecomem GSM Route BRI 3G Installation amp User Guide 6 Returns Form v telecoMem Unit Serial No Date Of Installation Return Date Returned From Company Address Post Code Fault Details Returns Number iscsceee emm mmm 15
6. flash once GSM Module 1 status Green LED every 6 seconds while looking for a base GSM Module 2 status Green LED station ISDN customer side B1 Red LED ISDN customer side B2 Red LED After this time the LEDs will flash ISDN network side B1 Red LED independently according to the signal ISDN network side B2 Red LED received as below Signal strength Module 1 LED Signal strength Module 2 LED 0 1 flash poor signal strength 2 4 flash average signal strength 4 8 flash good signal strength For guidance purposes you require a minimum of two flashes If there is only one flash then you will need to adjust the antenna e or find a more suitable location for the GSM Route BRI 3G 10 GSM Route BRI 3G Installation amp User Guide telecom FM 4 7 Connecting the ISDN 1 Connect the customer s Terminal Equipment to the GSM Route BRI 3G TE RJ45 port using a straight through RJ 45 cable ISDN Configuration ISDN Network Terminal Equipment FIGURE 3 2 If a connection to the ISDN network is required connect the standard basic rate ISDN to the GSM Route BRI 3G NT RJ 45 port using a straight through RJ 45 cable The unit will reset after 15 seconds then automatically configure itself to the ISDN circuit see figure 3 4 8 Connecting to ISDN Trunk ports 1 If no connection to an ISDN circuit is required Connect the ISDN Trunk Port of the PBX to the GSM Route BRI 3G TE RJ45 port using a straight
7. it is present If GSM Route BRI 3G detects that an ISDN circuit is not available the unit will be configured for this setting The GSM Route BRI 3G will Auto detect Point to Point or Point to Multi Point On connection of an ISDN circuit The GSM Route BRI 3G will direct outgoing calls either over the Mobile Network or the ISDN network according to its configuration Incoming calls from the GSM network will be directed to the customer s terminal equipment 3 2 Power Failure In the event of loss of power to the unit the ISDN lines connected through the GSM Route BRI 3G will connect the customer s terminal equipment directly to the ISDN network if it exists by means of a Metallic by pass mechanism 3 3 Mobile Signal Failure In the event of the loss of the GSM network the unit may be configured to re route the calls over ISDN 3 4 ISDN Signal Failure In the event of disconnection from the ISDN network calls which were routed across the mobile network will continue to do so 3 5 Power Supply The GSM Route BRI 3G operates from a nominal 100 240v AC supply 50 60 Hz Please ensure that you use only the power supply supplied with the GSM Route BRI 3G GSM Route BRI 3G Installation amp User Guide m telecom FM 3 6 Warning Do not attempt to work on the GSM Route BRI 3G with the mains connected 3 7 Safety Instructions Failure to follow all instructions may result in improper operation of the GSM Route BRI 3G and or the risk
8. of electrical shock All installation personnel should consult the information contained in this manual before attempting to install this product All installation engineers should adhere to the following instructions 1 The GSM Route BRI 3G should only be installed or maintained by qualified personnel who have been trained by TelecomFM or one of their certified representatives 2 The GSM Route BRI 3G should only be installed according to the instructions in this manual 3 Do not attempt to connect the GSM Route BRI 3G whilst the associated PABX is in use 4 Do not attempt to install the GSM Route BRI 3G during an electrical storm 5 Use caution when installing or modifying ISDN lines when connecting to the GSM Route BRI 3G 6 The mains AC power socket or switched spur outlet should be installed near to the GSM Route BRI 3G and should be easily accessible 7 Connect the power supply lead to the GSM Route BRI 3G before switching on the power GSM Route BRI 3G Installation amp User Guide m telecom FM 4 Standard Installation 4 1 Siting the GSM Route BRI 3G Select a suitable location to install the GSM Route BRI 3G in order to optimise the signal strength on or near an exterior wall close to a window on the top floor of the building at least 1 metre away from other sensitive electronic equipment The signal strength will be degraded if you install the GSM Route BRI 3G antennae e on walls that contain a large
9. ral population Specific Absorption Rate SAR is the unit of measurement for the amount of radio frequency absorbed by the body when using a mobile phone For GSM terminal equipment an MPE calculation is used to determine the safe working distance from the Terminal during normal use The values stated are determined at the highest certified power levels in laboratory conditions Actual radiated levels during normal use may be well below this value This is because the RF transmitter is designed to work at minimum power where ever possible TelecomFM GSM Route BRI 3G meets the legal requirements of ICNI RP encompassed within the following standards The GSM Route BRI 3G complies with European standards EN 50383 2003 EN 50392 2002 and EN50385 2002 and with Council Recommendation 1999 519 EC relating to human exposure to RF energy In accordance with these standards and in order to maintain safe levels of exposure to RF Energy the GSM Route BRI 3G and its antennae during use must be placed at a distance greater than 13 45cm from the human body GSM Route BRI 3G Installation amp User Guide m telecom FM 3 Overview 3 1 Intended Use The GSM Route BRI 3G is connected to the customer s ETSI standard basic rate ISDN terminal equipment and an ETSI standard basic rate ISDN network The GSM Route BRI 3G can also be configured to work on ISDN trunk ports where basic rate ISDN is not available The GSM Route BRI 3G will auto detect if an ISDN circu
10. sa 13 4 12 Before Ledvilid SIEBSeeanciteseteuobtat i ur pereat pv della ale r aliis sierra 13 5 Trouble Shooting Guide 14 6 Returns Form 15 GSM Route BRI 3G Installation amp User Guide 2 Notices 2 1 Package Contents The unit will be supplied with RJ45 Type connector GSM Route BRI 3G Power Supply Unit 2 x Antenna for GSM Route BRI 3G 2 or 1 x Antenna for GSM Route BRI 3G 1 A B C QmmoO 2 2 Guarantee Unit Fixings Fixing Templates Installation Guide 1 x 2 meter RJ 45 connection cable A telecomew The GSM Route BRI 3G is supplied with a 1 year return to base warranty which covers any defect in manufacturing and design No other warranties whatsoever are given If a faulty unit is required to be returned within the terms of the warranty a completed Returns Form p 15 should be attached and returned with the faulty unit TelecomFM shall accept no liability for any error or damages of any kind resulting from the use of this document or equipment it relates to No responsibility is assumed by TFM for the use or reliability of the GSM Route BRI 3G when used in a situation or with other equipment not supplied or specified by TFM The wording in this document may change from time to time Please refer to the TelecomFM web site www telecomfm co uk for the latest release 2 3 Document Control Date Version Change Aug 2010 1 1 release of document Sep 2010 2 Format update Dec 2010 3 Name update
11. through RJ 45 cable The unit will reset after 15 seconds then automatically configure itself to this setting see figure 4 NO ISDN TRACK Configuration m L TE to ISDN Trunk Ports Fisure 4 11 GSM Route BRI 3G Installation amp User Guide 3 telecom FM 4 9 Programming Via a Local Digital Management Centre If Applicable 1 If the unit is to be remotely managed contact your designated Remote Management Center and inform them as to the template to be used When you initiate a call home either connect your ISDN phone to the TE port direct or access the PBX and proceed with the following Off hook Dial 0000 or Dial 0 1 Only applicable if in the routing code On hook This will dial the call home number that is in the configuration map When connected the two Green Status LED s 24 amp 25 will flash intermittently indicating that data is being transfer to and from the device during the programming sequence LED 24 represents transmitted data LED 25 represents receiving data Once the programming sequence is complete the Green Status LEDs will return to reflecting the modules status 4 10 Programming Using the Unmanaged Local Programmer If Applicable 1 If the unit is NOT remotely managed and has not been pre programmed you will need to locally program the unit Please refer to the Unmanaged Local Programming Guide or contact the distributor you purchased the unit from 12 GSM Ro
12. ute BRI 3G Installation amp User Guide m telecom FM 4 11 Testing the GSM Route BRI 3G 1 Make an outgoing test call over module 1 Once Connected the Red Status LED corresponding to the channel being used will come on The Green Status LED for module 1 will come on showing that the call has been routed correctly 2 Make an outgoing test call over module 2 Once connected the Red Status LED corresponding to the channel being used will come on The Green Status LED for module 2 will come on showing that the call has been routed correctly 3 Make an incoming call to each GSM module 4 12 Before Leaving Site Advise the Customer of their new GSM numbers Fill in all site documentation obtain an acceptance signature from the customer and leave a copy of the documentation with the customer This will be the site record 13 GSM Route BRI 3G Installation amp User Guide 5 Trouble Shooting Guide PROBLEMS RECOMMENDATI ONS GSM Route BRI 3G will not power up Unit will not dial home over ISDN Check the lead into the chassis Check the Power Supply Unit Check for mains power Check that the ISDN circuit is live Unit will not dial home over GSM Check that the SIMs are live Check Management Programming ISDN set to false with correct GSM number Unit will not route Check programming with TFM help desk If applicable Check programming with Unmanaged local Programmer If applicable Misrouting problems