Home

User Guide - LanckerWolters

image

Contents

1. see page Master User Guide for details on selecting which zones chime Once a zone has been selected for chime the Chime facility can be manually turned on and off as required ch The system can also be programmed to automatically turn chime on and off under certain conditions i e certain times of the day door left open etc If no zones have been programmed for Chime then turning Chime on and off will have no effect To turn CHIME On To turn CHIME Off 1 Press 1 Press The Chime tone will sound The Error tone will sound INS221 9 Operating the Alarm System Premier Series User Guide To CHANGE Your User Code Users with access to this option can change their own User codes User codes are unique to each user and can be 4 5 or 6 digits long CS Only the User code that is entered to access the change code menu will be changed Before changing your code it is vital that you memorise or write down the new code you are about to program Failure to remember your code will require an engineer visit to re program a new code for you This may incur a call out charge 1 Enter the User code that requires changing C gt C C C 2 Press 3 Press 4 Press 5 Press 6 Enter a new 4 5 or 6 digit User code DDMD 7 Press to accept the new code 8 Press to exit the menu The display will return to normal 10 INS221 Premier Series User Guide Operating the Alarm System 3 Quick Reference Guide Operatio
2. has been started you should leave the premises immediately however if for some reason you decide not to leave the exit mode must be cancelled 1 Enter a valid User code DDO 2 Press The exit tone will stop To CLEAR an Arm Fail When the system tries to arm with zones active open the internal sounders will sound and the external strobe will be flashing to indicate a problem For details on preventing an Arm Fail condition please refer to page 3 ch If you were not present when the Arm Fail occurred or you do not clear the Arm Fail the internal sounders will continue to sound and the external strobe will continue to flash 1 Enter a valid User code DADDA The internal and external sounders will stop the external strobe will continue to flash and the number of the zone that caused the Arm Fail will be displayed 2 Enter a valid User code D DDA and press To SILENCE an Alarm When an alarm occurs on the system the internal and external sounders will normally sound for a pre programmed time normally 15 minutes ch If you were not present when the alarm activated the internal and external sounders may have already stopped but the external strobe will still be flashing When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events 1 Enter a valid User code DADDA The internal and external sounders will stop and the number of the zone t
3. A _ User Guide Premier 24 48 88 168 640 Issue 3 f Tex www texe com Overview Premier Series User Guide Introduction Users of the alarm system will be assigned a unique 4 5 or 6 digit User code User codes are used to arm and disarm the system Some User codes can also access additional options such as system tests and omitting zones Keypads will be installed throughout the premises usually one at each entry exit door The keypads are used to perform all of the system operations i e Arming Disarming etc Most User codes can be used at any keypad on the system However Local Users will only be able to use certain keypads on the system The Emergency Keys In case of emergency the alarm system can provide three immediate emergency alarms by pressing and holding two specific keys for two seconds CS The emergency keys can be enabled disabled for each keypad on the system The Panic alarm can be programmed for either audible or silent operation The Panic alarm can be programmed for either instant or delayed operation Emergency Alarm Press Keys Panic Alarm PA a amp Fire amp Medical amp The Quick Arm Keys The Quick Arm keys allow the system to be armed without having to enter a User code first CS The Quick Arm keys will only work if the keypad has been programmed to allow arming in this way To FULL arm the system press Crea To PART arm the system p
4. d to be reset by an Engineer pressing will not return the display to normal if this is the case see ENGINEER Reset for details The system may have been programmed to be reset by Anti code if this is the case see ANTI CODE Reset for details 1 Enter a valid User code DOMDA 2 Press The external strobe will stop the system will chime and the display will return to normal ENGINEER Reset If the system has been programmed to be reset by an Engineer following an alarm activation you will still be able to silence the alarm by entering a valid User code see page 6 for details ch The system cannot be armed again until the alarm has been reset 1 Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide ANTI CODE Reset If the system has been programmed to be reset using an Anti Code following an alarm activation you will still be able to silence the alarm by entering a valid User code see page 6 for details cS The system cannot be armed again until the alarm has been reset 1 Enter a valid User code DODDO 2 Press The display will show a random code number i e 4281 3 Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide and quote the random code number You will be given a 4 digit Anti Code i e 5624 4 Enter the Anti code that has been given to you C gt C C C 5 Press If the Anti c
5. e system is PART Armed when ONE OR MORE zones have been left OFF omitted i e the landing or a bedroom CS The system is only Part Armed when zones are omitted using the Part Arm procedure omitting zones manually see page 9 for details is not classed as Part Arming The bottom line of the display is programmable for each Part Arm Your Installer may have programmed the system so that it can be Part Armed by just pressing D or followed by Car if this is the case then there is no need to enter the User code below 1 Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on 2 Enter a valid User code C gt C C C 3 Press 4 Use keys AD to select the required Part Arm 5 Press to arm normally or press to arm silently The exit tone will sound if silent arm has not been selected 6 Leave the protected area When the system has armed the exit tone if sounding will stop 4 INS221 Premier Series User Guide Operating the Alarm System To ARM Individual Areas If the system has been split up into separate areas of protection i e Area 1 House Area 2 Garage Area 3 Shed etc These areas can be individually selected for FULL or PART arming as required cS Areas are selected by using keys O gt the C4 key can also be used to select an area followed by or CNo Only areas that exist on the system can be selected A Star means
6. hat caused the alarm will be displayed The alarm now needs to be reset 6 INS221 Premier Series User Guide Operating the Alarm System To DISPLAY the cause s of System Alerts Alarms When silencing an alarm or unsetting the system after an alarm the number of the zone s will be displayed on the keypad If several zones were triggered the display will scroll through each in turn After noting the cause of the alarm the system can be reset as described in RESET After an Alarm below System Alerts When the system has faults to display or has not been reset after an alarm condition the display may show SYSTEM ALERTS Enter a valid User code DDD Any alarms or faults will be displayed If several fault or alarm conditions have been triggered the display will scroll through each in turn After noting the cause of the alarm or fault the system can be reset as described in RESET After an Alarm below ch Some action may be required to clear the cause of the alarm or fault in order to successfully reset the panel INS221 7 Operating the Alarm System Premier Series User Guide To RESET After an Alarm If the display shows SYSTEM ALERTS follow the steps described in To DISPLAY the causes of System Alerts above before attempting to reset USER Reset Once the alarm has been silenced see page 6 for details the system will need to be reset ch If the system has been programme
7. ill stop and the exit tone will resume when all zones are secure If it is necessary to leave a zone open then it must be omitted see page 9 for details CS If an active zone cannot be secured then it may be in fault in this case contact the alarm company immediately Arm Fail Failing to Arm If the exit procedure is started and zones are still Active at the end of the exit procedure an Internal alarm will occur internal sounders only and the strobe light on the external sounder will flash ch If this occurs the arm fail must be cleared and the zone in fault identified before the system can be armed see page 6 for details on clearing an Arm Fail The Ready LED To help prevent faults during arming a Ready light has been provided see table above for details on how the Ready LED operates INS221 3 Operating the Alarm System Premier Series User Guide 2 Operating the Alarm System To FULL Arm the System The system is FULL Armed when ALL zones are ON not omitted cS Your Installer may have programmed the system so that it can be set by just pressing area if this is the case then there is no need to enter the User code below 1 Ensure that the premises are secure all doors and windows closed etc and the Ready light is on 2 Enter a valid User code DODA 3 Press to arm The exit tone will sound 4 Leave the premises When the system has armed the exit tone will stop To PART Arm the System Th
8. n To Full Arm the System Description Enter a valid User code Press Yes or press Chime to arm silently Action DDOD Or Gems To Part Arm the System Enter a valid User code Press Part Select Required Part Arm Press Yes or press Chime to arm silently DODO a or GD OF Gein To Arm Individual Areas Enter a valid User code Press Area Select Required Area using keys 1 8 Press Yes or press Chime to arm silently MOO D Gees OF Gems To Disarm the System To Cancel the Exit Mode Enter a valid User code Press Yes if the entry mode was not started Enter a valid User code Press Yes OCG DDOD To Clear an Arm Fail Enter a valid User code Press Reset DODDO To Silence an Alarm To Reset After an Alarm Enter a valid User code Enter a valid User code Press Reset DDOD DODDO To Engineer Reset Contact Your Installation Company To Anti code Reset To Omit Zones Enter a valid User code Press Reset Contact Your Alarm Receiving Centre Quote 4 digit code shown on display Enter 4 digit code given by Receiving Centre Press Yes Enter a valid User code Press Omit Enter Zone Number s Press Omit to toggle omit status on off Press Menu when finished Press Yes to Arm DDOD Kees Quobes DOOD Turn Chime On Off Press Chime Once to Turn ON Press Chime Again to Turn OFF To Change User Code Enter a valid User code Pre
9. ode is correct the keypad will bleep to indicate that the system has been reset and the display will return to normal 8 INS221 Premier Series User Guide Operating the Alarm System To OMIT Zones It is possible to exclude omit individual zones when arming i e if a zone is in fault Users with access to this function can only omit zones that have been programmed as Omittable cS If the zone can be omitted there will be a Star to the right of the zone number Only zones that have the Omit attribute assigned to them can be omitted A Star will appear to the left of the zone number to indicate that the zone has been selected for omitting All omitted zones will be automatically reinstated the next time the system is disarmed unless programmed otherwise To re instate zones manually simply follow the instructions again However when the key is pressed on this occasion the zones will be re instated 1 Enter a valid User code D C C C2 and press 2 Enter the zone number DDAA 3 Press to omit the selected zone Repeat for other zones if required 4 Press when finished Continue to arm the system as normal The Turn CHIME On and Off The system can be set up so that activating opening certain zones will cause the internal sounders to chime This would normally be used on a front door exit button etc CS Zones will only cause the internal sounders to chime if they are selected for chime
10. ress D or followed by Ca Keypad Lock The keys on the keypad can be locked to prevent unwanted access to the system ch The Emergency keys will NOT operate with the keys locked To Lock the keys press and together To Unlock the keys press and together again 2 INS221 Premier Series User Guide Overview LED Indicators Five LED indicators have been provided to indicate the status of the system Status Meaning Power AC mains is present on the control panel Flashing AC Mains is not present the control panel is running on the standby battery Service The system requires attention contact your installer The system does NOT require attention All zones are secure and the system is ready to be armed One or more zones are active Flashing The system has zones with the Force Omit attribute that are active The system is armed can also be programmed for other indications The system is unarmed can also be programmed for other indications One or more zones are omitted No zones are omitted Zone Faults During Arming Before attempting to arm the system ensure that the premises are secure all doors and windows closed etc and the Ready light is on If an attempt is made to arm the system with any zones active e g door ajar open window etc the internal sounders will bleep repeatedly fault tone and the display will show the zones that are active The fault tone w
11. ss Menu followed by Yes Press 2 followed by Yes Enter a new 4 5 or 6 digit User code Press Yes to accept Press Reset to return to the normal display INS221 11 Installation Company Details Installation Engineer Installation Company Address Telephone Number Installation Date Service Record Date Serviced Comments Engineer Emergency Telephone Numbers For 24 Hour Call Out For Anti Code Reset Control Panel Details Model Premier 24 TT Premier48 Premier88 Premier 168 Premier 640 CT Location TEXECOM LTD 2000 2008 INS221 3
12. the area can be selected and a Dot means the area cannot be selected Pressing will select deselect all areas pressing will toggle between the first 8 areas and the second 8 areas where applicable 1 Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on 2 Enter a valid User code DOMDA 3 Press 4 Use keys AD to select the required areas 5 Press or to FULL arm the areas Or 5 Press CDAD or followed by or to PART arm the areas The exit tone will sound if silent arm has not been selected 6 Leave the premises When the system has armed the exit tone if sounding will stop To DISARM the System The entry time is divided into two sections the Entry time and the 2 Entry time If the Entry time expires an Internal alarm will occur and the 2 Entry time will start If the 2 Entry time expires an Intruder alarm will occur all internal and external sounders ch It is perfectly normal for the 2 Entry time to be programmed as zero in which case an Intruder alarm will occur as soon as the Entry time expires 1 Enter the premises via the designated entry point The entry tone will start 2 Enter a valid User code DDD The entry tone will stop INS221 5 Operating the Alarm System Premier Series User Guide To DISARM the System When Not in Entry 1 Enter a valid User code DADDA 2 Press To CANCEL the Exit Mode Once the exit mode

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung    KOHLER K-3944-1-NA Installation Guide  RainerBraunschmidtMagisterarbeit  Manual de Instalação  MANUEL D`INSTRUCTIONS ET D`UTILISATION Poêle à bois  Integrated Amplifier User Manual  Adobe MARCOM Sample  FT- Fondur à cirer [Mode de compatibilité]  関連PDF1 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file