Home
Installation & User Guide SHOWER FITTINGS MIRA
Contents
1. Service Our Service Force is available to provide a quality service at a reasonable cost You will have the assurance of a Mira trained engineer agent genuine Mira spare parts and a 12 month guarantee on the repair Payment should be made directly to the engineer agent using Visa MasterCard or a cheque supported by a banker s card To Contact Us England Scotland Wales amp Northern Ireland Mira Showers Customer Services Telephone 0870 241 0888 Mon to Fri 8 00 am 5 30 pm Sat 8 30 am 3 30 pm E mail technical mirashowers com Fax 01242 282595 By Post Cromwell Road Cheltenham Gloucestershire GL52 5EP Republic of Ireland Eire Modern Plant Ltd Dublin Telephone 01 459 1344 Mon to Fri 9 00 am 5 00 pm E mail sales modernplant ie Fax Dublin 01 459 2329 Post Otter House Naas Road Clondalkin Dublin 22 Modern Plant Cork Telephone 021 496 8755 Mon to Fri 9 00 am 5 00 pm E mail cork modernplant ie Fax 021 496 8607 Post Tramore Road Cork SHOWERS FM 14648 Kohler Mira Limited February 2007
2. 15 Outer Nozzel Ring Retainer See O Seals Inner Nozzel Ring Retainer Ke Spray Plate Assembly Adjuster Ring Spray Plate Assembly Removal 1 Turn the adjuster ring fully anticlockwise 2 Unclip and remove the adjuster ring 3 Unscrew the spray plate assembly in an anticlockwise direction The O seals will provide some resistance 4 Remove the inner and outer nozzle retaining rings Nozzle Ring Removal 1 Carry out instructions 1 to 4 of Spray Plate Removal 2 Remove both the inner and outer low capacity nozzle rings 3 Carryoutinstructions 1 to 6 of Spray Plate Installation Spray Plate Installation 1 Make sure that the four O seals are all correctly fitted 2 Fit inner nozzle ring retainer on to the spray plate assembly and fit the outer nozzle ring retainer on to the flow divertor 3 Turn the flow divertor fully clockwise 4 Carefully screw the spray plate assembly onto the flow divertor 5 Align the inner teeth on the adjuster ring with the teeth on the handset flow divertor Clip the adjuster ring into position 16 Handset Body Assembly Outer Nozzle Retaining Ring Inner Nozzle Assembly Adjuster Ring Outer Nozzle Retaining Ring Inner Nozzle Retaining Ring Spray Plate Assembly Spray Plate Assembly Seal Inner Nozzle Retaining Ring Outer Nozzle Retaining Ring O Seals Teeth Flow
3. Divertor Adjuster Ring Spray Plate Assembly Inner Teeth FAULT DIAGNOSIS The trouble shooting information tabled below gives details on what you can do as a user should you encounter difficulties with the shower fittings whilst operating the shower Before replacing any parts make sure that the underlying cause of the malfunction has been resolved Malfunction No flow or low flow rate from the shower fitting Water dripping from the handset spray plate The shower temperature changes when the spray setting is adjusted Hose does not fit into the clamp bracket securely The spray plate assembly is blocked The hose is blocked or twisted Problem with the shower control A small amount of water may be retained in the shower handset after the shower control has been turned off This may drain over a few minutes Defective shower control The spray plate assembly is blocked Clamp bracket fitted upside down in the slide rail 17 Refer to the Cleaning section Clear blockage or replace the hose Refer to the Appliance Installation and User Guide This is quite normal Adjusting the position of the shower handset may reduce the draining time Refer to the Appliance Installation and User Guide Make sure that the spray plate assembly is clean Refer to the Cleaning section If the malfunction persists refer to the Appliance Installation and User Guide R
4. Swivel Insert Shroud Screws Corner Mounting 1 For corner mounting first follow instructions on pages 7 and 8 steps 1 to 6 Hold the slide rail assembly against the wall in the desired position Use the slide rail supports as a template and mark the position of the two top fixing holes and the two bottom fixing holes Note Check that the slide rail supports are sitting on both walls before drilling fixing holes Drill two 8mm fixing holes at the top of the slide rail and two at the bottom of the slide rail Caution Make sure that you avoid buried pipes and cables when you drill the wall Fit the wall plugs Hold the slide rail against the wall and gently screw the slide rail into position Check that the slide rail is vertical and make any adjustments before fully tightening the fixing screws Push on the slide rail support covers To complete the installation follow steps 13 to 19 on pages 11 and 12 13 Slide Rail Support Tte Screw Screw Fixing Holes For Corner Position M OPERATION Adjustable Handset Operation The handset has four different spray modes Eco Start Soothe and Force The handset has a combined checkvalve and flow regulator fitted in the handset The handset operation is described below 1 Eco Water flows from the outer set of holes at a reduced flow rate to save water To select the Eco setting
5. assembly Slide Rail Support Long Edge d Clamp Bracket Hold the slide rail assembly against the wall in the desired position Note If fixing the slide rail into a corner see Corner Mounting page 13 Use the slide rail supports as a template and mark the positions of the top and bottom fixing holes Note When marking the position of the holes if using the vertical oval hole on the top of the slide rail then use the horizontal oval hole on the bottom fixing This will allow you to make slight vertical and horizontal adjustments to the slide rail Check that the slide rail is vertical before drilling fixing holes Caution Make sure that you avoid buried pipes and cables when you drill the wall Drill two 8 0 mm fixing holes one at the top of the slide rail and one at the bottom of the slide rail 9 10 Fit the wall plugs 11 Hold the slide rail against the wall and gently screw the slide rail into position Check that the slide rail is vertical and make any adjustments before fully tightening the wall screws 12 Push on the slide rail support covers 10 Wall Plug Wall Screw Clamp Bracket Hose Retaining Ring Slide Rail Support Cover 13 14 15 Align the notch on the soap dish with t
6. turn the spray plate fully clockwise 2 Start Turn the spray plate anticlockwise until it clicks Water will flow from the outer set of holes 3 Soothe Turn the spray plate anticlockwise until it clicks Water will flow from the large diameter holes 4 Force Turn the spray plate anticlockwise until it clicks Water will flow from the inner set of holes 14 MAINTENANCE Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent or soap solution and then wiped dry using a soft cloth 1 Toremove limescale use your thumb or a soft cloth to wipe any limescale from the soft rubber nozzles and the front face of the showerhead Spray Plate Assembly Internal 1 Remove the spray plate assembly Refer to Spray plate assembly removal and installation 2 Remove the inner and outer nozzle ring retainers 3 Clean all the components with a stiff brush If necessary use a plastic kettle descalent in accordance with the manufacturer s instructions Flush thoroughly with water before the shower is used 4 f necessary replace the O seals Refer to Spare Parts 5 Refit the components in reverse order Make sure the O seals and the inner outer nozzle ring retainers are fitted correctly Refer to Spray plate assembly removal and installation
7. After Sales service As part of our quality and training programme calls may be recorded or monitored Our Customer Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit Mira Showers Kohler Mira Limited Cromwell Road Cheltenham GL52 5EP 1073000 W2 A L12A Mira is a registered trade mark of Kohler Mira Limited The company reserves the right to alter product specifications without notice www mirashowers com Spare Parts We maintain an extensive stock of spares and aim to provide support throughout the product s expected life Spares can be purchased from approved stockists or merchants locations on request or direct from Customer Services Spares direct will normally be despatched within two working days Payment can be made by Visa or MasterCard at the time of ordering Should payment by cheque be preferred a pro forma invoice will be sent All spares are guaranteed for 12 months from the date of purchase Spares that have been supplied directly from us can be returned within one month from the date of purchase providing that they are in good order and the packaging unopened Note Returned spares will be subject to a 15 restocking charge and authorisation must be obtained before return contact our Customer Services Team Note In the interests of safety spares requiring exposure to mains voltages can only be sent to competent persons
8. corner Note To prevent back siphonage and water supply contamination the handset must either be prevented from dropping below the spill over level of the bath or shower or have an additional single check valve in the system Single check valves may already be installed as part of the shower control Install the Shower Fittings Complete Wall Mounting 1 Decide on a suitable position for c the slide rail avoiding buried cables and pipes Make sure that when the hose retaining ring is placed on the lowest position on the slide rail there is a minimum of 25 mm between the handset and bath tray spill over level This is necessary to prevent back siphonage Note Special consideration should be given to fixing arrangements when installing onto a dry lined stud partition shower cubicle or laminated panel wall structures Installers may wish to obtain alternative proprietary cavity fixing or choose other options however these methods of fixing are Minimum 25mm beyond the scope of this guide M Carefully remove the protective film from the slide rail Holding the clamp bracket squeeze the sides together and push the clamp bracket onto the slide rail Note It is important that you slide the shorter edge of the clamp bracket onto the slide rail Slide the hose retaining ring onto the slide rail Push the slide rail supports onto each end of the slide rail
9. djustable spray handset with four different spray actions Eco Start Soothe and Force The shower hose terminates in a 1 2 BSP female thread for connection to the outlet of the shower PACK CONTENTS V Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included Mira Advance Shower Fittings A wy a 2 x Slide Rail Support Covers L 2 x Slide Rail Supports L 4 x Screws 1 2 x Hose Washers 1 x Slide Rail L Ring L T T TTA RR RS T ELEC RUTAS CR gt 1000000 1 x Wall Mounted Handset Holder Advance Flex only Documentation 1 x Installation and User Guide Flex Version 1000 600 All dimensions in mm 6 INSTALLATION General Make sure that the shower fittings are installed by a competent installer Installations must comply with Water Regulations Bye Laws Scotland and any Local Regulations and Building Regulations in force at the time of installation Before installation carefully inspect the new fixture for any signs of damage The slide rail should be positioned to one side of the shower control at a convenient height for all the family The slide rail can be fixed to a flat wall or into a
10. emove the clamp bracket and rotate 180 and refit SPARES 450 08 Service Pack O Seals components identified 632 73 Hose Washer 1603 098 Handset White 1603 102 Slide Rail Supports x 2 1603 103 Soap Dish and Hose Retaining Ring 1603 104 Chrome Hose 1 25m 1603 106 Chrome Hose 2m Flex Product 1603 112 Mounting Pack 1603 113 Slide Rail 06 Satin 1603 114 Slide Rail 10 Satin 1603 115 Adjuster Ring White 1603 116 Spray Plate Assembly 1603 120 Wall Mounted Handset Holder 1603 131 Adjuster Ring Grey 1603 132 Flex Clamp Bracket 1603 128 Handset Grey Adjuster Ring 1644 124 Clamp Bracket 18 Mira Advance Shower Fittings Spare Parts Diagram 1603 112 1603 113 1603 114 Eo 1603 102 1603 115 1603 131 1644 124 1603 132 1603 120 1603 103 1603 104 1603 106 OMER SERVICE Guarantee of Quality Mira Showers guarantee your product against any defect in materials or workmanship for the period shown in the Guarantee Registration Document included with your shower Alternatively to confirm the applicable guarantee period please contact Customer Services To validate the guarantee please return your completed registration card Within the guarantee period we will resolve defects free of charge by repairing or replacing parts or modules as we may choose To be free of charge service work must only be undertaken by Mira Showers o
11. he recess on the hose retaining ring Push the soap dish onto the hose retaining ring To lock the soap dish into position twist the soap dish to the right or if preferred twist to the left Note If space is limited you do not have to fit the soap dish to the hose retaining ring but the hose retaining ring must be fitted 11 Recess 16 17 18 19 Attach the hose onto the handset Make sure that the hose washer is fitted and do not overtighten Pass the hose through the hose retaining ring and soap dish if fitted Attach the hose to the outlet of the shower control Make sure that the hose washer is fitted Place the handset into the clamp bracket Wall Mounted Handset Holder Advance Flex Only 1 The shroud must be removed to fix the handset holder to the wall Ensure the swivel insert is in the horizontal position before removing the shroud Using the swivel insert holder as a guide mark the position of the two screw holes Drill two 8mm holes and insert the wall plugs provided Screw the swivel insert holder to the wall using the screws provided It may be necessary to remove the swivel insert to fit the holder Ensure the insert is refitted as originally supplied or the handset will not fit correctly in the holder With the swivel insert in the horizontal position push fit the shroud until it locks into position 12 Swivel Insert Holder
12. mira ADVANGE MIRA ADVANCE SHOWER FITTINGS Installation amp User Guide These instructions are to be left with the user amp PlumbNation the nation s favourite for v FREE SHIPPING v SECURE PAYMENTS on all orders over 100 to mainland UK shop online with confidence v FINANCE AVAILABLE v PRICE MATCH spread the cost with low interest rates always get the best deals available we have HUGE REDUCTIONS ON THOUSANDS OF ITEMS Boilers Bathroom suites aa eae eee siecle aaah 33 on eeu duum Pipes amp fittings Wet rooms Cylinders Towel warmers Fires 000 Bathroom furniture Renewable energy amp much more C un visit our website 2 7 plumbnation co uk 0844 800 3460 CONTENTS MAHOU CU OM P 3 SPECICATION araid 4 Pack Contents irismenaren aieeaa anaana 5 DIMENSIONS ec EMIL 6 Ih jer T 7 Operation 14 Maintenarice iicet ee i de E annee RR REN Xe dX Res dus SR 15 Fault Diagnosi S spune ig tea 17 Spare parts e 18 Customer cmi te i d RR ester De edo n e e da d 20 If you experience any difficulty with the installation or operation of your new shower fittings then please refer to Fault Diagnosis before contacting Kohler Mira Limited Ou
13. r our approved agents Service under this guarantee does not affect the expiry date The guarantee on any exchanged parts or product ends when the normal product guarantee period expires Not covered by this guarantee Damage or defects arising from incorrect installation improper use or lack of maintenance including build up of limescale Damage or defects if the product is taken apart repaired or modified by any persons not authorised by Mira Showers or our approved agents This guarantee is in addition to your statutory and other legal rights Before using your Shower Please take the time to read and understand the operating and safety instructions detailed in this manual What to do if something goes wrong If when you first use your shower it doesn t function correctly first contact your installer to check that installation and commissioning are satisfactory and in accordance with the instructions in this manual We are on hand to offer you or your installer any advice you may need Should this not resolve the difficulty simply contact our Customer Services Team who will give every assistance and if necessary arrange for our service engineer to visit If the performance of your shower declines consult this manual to see whether simple home maintenance is required Please call our Customer Services Team to talk the difficulty through request a service under guarantee if applicable or take advantage of our comprehensive
14. r telephone and fax numbers can be found on the back cover of this guide INTRODUCTION The Mira Advance Shower Fittings Mira Advance shower fittings are precision engineered to give a great shower over a range of pressures The Advance shower fittings can be fitted onto a flat wall or fitted into a corner position to satisfy and compliment various shower areas Wall Mounted Corner Mounted Product covered by this Guide Advance Complete Fittings An adjustable spray handset flexible hose adjustable clamp bracket assembly slide rail hose retaining ring and soap dish Suitable for connection to surface mounted showers Advance Flex wall mounted handset holder Advance Flex product only is suitable for connection to surface mounted shower controls only Patents Design Registraion 000738141 0006 000738141 0007 000738141 0008 3 SPECIFICATION Specifications Minimum maintained pressure 6 kPa 0 06 Bar Maximum maintained pressure 500 kPa 5 0 bar Warning Exceeding the stated maximum maintained pressure could result in excessive spray forces and possible damage to the product Pressure loss Pressure difference between the inlet and outlet of the fitting 26 24 Force Start Soothe Flow Rate Litres Minute 0 0 2 0 4 0 6 0 8 1 0 1 2 1 4 Pressure Loss Bar The Handset An a