Home

uSer guide - Roger Hardiman rjh.org.uk

image

Contents

1. 7 press START STOP again to continue with this run press RESET to clear display data of run is still in memory Recall data from memory stored data laps runs can be recalled at anytime during or after a run 1 press RECALL to enter recall Mode 2 there are two operations now depending if memory is empty or not a if memory is empty only 1 run then you immediately access that run and you continue with step 2 below b if memory is not empty more then one run stored you can now select which run you would like to recall The date and number of the particular run will be indicated for each run and by pressing SELECT allows you to jump through the different runs which are stored in the memory After selecting the run you would like to recall simply proceed with step 3 below 3 press RECALL to see the 1 lap of the selected run 4 press RECALL again to see 2 3 etc lap of the selected run 5 after all individual laps are shown the stopwatch will also indicate Stop Time Average Lap AVE Best Lap BES Slowest Lap SLO 6 press MODE to return from recall to normal stopwatch function Clean delete data from memory please frequently clean up the memory as it will otherwise fill up quickly clean result from last run display only by pressing RESET after stopping timing press RECALL and choose the run you would like to delete by pressing SELECT keep SET pressed for 3sec to delete this
2. pacer clock and alarm function e Display of best BES slowest SLO and average AVE laps and up to 999 Laps counting e Segregated 500 lap memory capability to memorize the laptimes of different races Please read the following instructions carefully before you start using this product This user guide contains im portant notes for the installation the safety the use and the maintenance of this product Thus protecting yourself and avoid damages of the product Proceed according to the user guide in order to understand your product better Please take your time as you will have much more joy with your product if you know it exactly This user manual shall be kept in a safe place If another customer is using this product this manual has to be handed out together with it STOPWATCH FUNCTION Using the stopwatch 1 press MODE until you enter stopwatch mode the remaining memory balance number is shown in the top left corner 2 press START STOP to start 3 press LAP SPLIT to take the 1st laptime lapcounter shows 1 laptime is indicated in the upper row split time is shown in the midle row elapsed total time since start is shown in the bottom row 4 press LAP SPLIT again to take the 2nd laptime lapcounter shows 2 laptime split time and elapsed time are indicated as above 5 you can continue operating as above until the memory 500 laps is full 6 when you completed this run press START STOP again
3. 63900 WORKS STORWATCH USER GUIDE CRF 1 2 E MI BLUE IS BETTER LRP electronic GmbH Wilhelm Enssle Str 132 134 73630 Remshalden Germany info LRP cc www LRP cc LRP electronic GmbH 2009 USB CONNECTION PC SOFTWARE Software Installation 1 put the included CD into your computers CD ROM drive 2 open folder Driver Win32 bit start file PL 2303 Driver Installer exe and follow the on screen instructions 3 finished Download Data 1 install PC software first see above 2 connect stopwatch with computer by the the included USB cable 3 start PC software 4 Press MODE until you see Upload 5 In case you don t want to upload all runs which are stored in the stopwatch select the run you would like to upload by pressing RECALL first and then selecting the run by pressing SELECT 6 if you want to upload all runs simply disregard point 5 press SET to upload the data to the computer during transmissin the display will indi and once the transmission is completed the display will indicate End you can now view your runs on your computer using the supplied simple PC software compare your result with previous data save it print it etc CLOCK amp ALARM The clock and alarm can indicate hours minutes seconds months date day year alarm and auto calendar in 12 and 24hours format 1 press MODE until you enter clock mode 2 the alarm hour alarm minutes month d
4. run once this run is deleted Ed will be displayed The stopwatch will make a BiBiBi sound during clearing the data in case you would like to clean the stopwatchs entire memory all runs then simply proceed as under 3 but keep SET pressed for more then 6sec until beeping sound changes and display indicates ALL CLEAR Ed which means all runs have been deleted Remarks e if the lap counter in the top left corner line displays 000 and flashes it means that the memory is full So please clear stored data before using it again if the lap counter is greater than 500 the stored data over 500 will be deleted when calculating AVE BES and SLO if the lap or split time is greater than 9hours 59min 59 99sec in any segregated period time the AVE BES and SLO information will be disabled when there is segregated memory AVE BES SLO and STOP for every run also use some storage so the memory space is actually slightly less then 500 laps in that case TAKING GARE OF YOUR UNIT Water Resistance this stopwatch is designed to withstand accidental contact with water such as splashes or rain but it is not designed for use in water Do not operate the buttons when the stopwatch is wet Operating Temperature Do not leave your stopwatch under direct sunlight or in very high temperature for a long time as the display may become black Do not leave your stopwatch in very low temperature as this may cause a slight time loss or
5. ate day year hour minute and seconds are displayed as shown 3 keep SELECT pressed for 2sec to set clock and alarm time The alarm time HOUR digits start flashing Time setting can be done by means of depressing SELECT to select digits and SET to advance digits Remarks Alarm is automatically armed if alarm hour or minute has been set Alarm can also be armed or disarmed by pressing RECALL during normal time mode When alarm is armed Alarm time is 60sec COUNTDOWN TIMER The dual countdown timers which start one after another can be used for training programs etc They can be used as ordinary single countdown timer if 2nd timer is not set Adjusting the Countdown Timer 1 press MODE until you see TR in top left corner of display the LCD s top row indi cates Timer1 and the middle row Timer2 2 keep SELECT pressed for 2sec this enters the setup mode with the hour digit of limer1 flashing 3 set the desired countdown time pressing SELECT jumps through the digits and pressing SET adjusts hours minutes and seconds individually for both Timer1 and limer2 row Using the Countdown Timer press SET to start countdown the 1 in the top right corner will blink and the timer setting counting down when Timer1 approaches zero the stopwatch beeps 4 times and Timer2 will start counting down if Timer2 has been selected when Timer2 approaches zero the stopwatch wi
6. gain and the change of digits becomes slow In both cases the above conditions will be corrected when the stopwatch is used under normal temperatures again Shocks do not to drop your stopwatch or hit it against hard surface as it may cause a mechanical damage Static Electricity The integrated circuit in your stopwatch can be affected by static electricity In case of a very strong static discharge a permanent damage can occur Be careful when operating close to a TV or when wearing synthetic clothing in very dry weather as both cases can generate a very strong electrical field Magnetism Not affected Chemicals Do not expose your stopwatch to solvents such as gasoline alcohol cleaning spray cosmetics paints etc as they may cause damage to the stopwatch Battery Replacement When the display becomes dim or faded out battery replacement is necessary unscrew and remove back cover unscrew the battery contact and remove the old battery before putting in a fresh battery make sure that the triangular contact is in the triagular slot under the battery replace with a fresh new lithium battery CR2032 or equivalent and reattach the battery contact and screw press all 4 buttons at the same time to reset re attach the back cover and screws
7. ll beep twice the 4 digit counter at the lowest row increases by 1 automatically at anytime during countdown pressing SET will stop counting Presettable from 10 beeps minute to 320 beeps minute Display of pacer frequency beep counter elapsed simul taneously Adjusting amp using the Pacer 1 press MODE until you see PACE in the display 2 The display indicates the selected pacer frequency in the bottom right blinking 3 press SELECT to choose desired beeps minute 10 20 30 40 60 80 120 160 200 220 240 320 4 press SET to start the pacer 5 a beeping sound of the choosen beeps min will sound The beep counter is at the center and the pacer frequency is at the lower row The beep counter has a range of 9999 6 press SET to stop pacer Remark Pacer will be reset if stopwatch is switched to another operating mode x The crossed out wheeled bin means that within the European Union the product must be taken to seperate collection at the product end of life Do not dispose of these products as unsorted muni E cipal waste Dear Customer thank you for your trust in this LRP product By purchasing an LRP WorksTeam Stopwatch you have bought an ac curate and highly advanced tool designed for serious racers It contains amongst others the following features e Highly accurate using japanese CMOS e USB connection incl PC software e Stopwatch up to 9 59 59 99 hours lap and split timing Timer

Download Pdf Manuals

image

Related Search

Related Contents

APart STFLOOR tripod  CB RADIO AE 4090 OPERATING MANUAL  Siemens MICROMASTER 440 User's Manual  Brinkmann 815-3880-0 Cooktop User Manual    Diagrammes fumées humides  OfficeConnect® Dual Speed Switch 4, Switch 8 and Switch 16  Maintenance Assistant RAD  オムニエースⅢ  Kramer Electronics VS-1616A audio amplifier  