1. 2 18 To Disconnect the Auria PowerPak 222 18 Replacing the Battery in the Auria PowerPak 2 18 Using the Aura PowerPak 8 de nee cor cos aura omis 19 Preparing the Auria PowerPak for use with the Plug or Huggie 19 sinc Telephone eo 20 Part Il Care and Maintenance of your HiRes Auria Processor 21 ONE ae a oo 21 ClGGHING eea a S REE E 21 HiRes Auria Processor Protection 21 Avoid the OO MIA Err EE APEE T EAER EENS 21 amp AURIA User Guide 1 CT ae Auria User Guide RevC qxp 6 15 07 10 09 AM Page 2 Re Elecro Stati Discharge SL 2 22 AUG CORE VIG COSC 24 242 40 datent Lane dtawed dade tawsenie nes ban 23 Dri Aid Function s 0t 000ueses eetes bance 23 Regenerating the Dri Aid Function 222 24 CSI ee E ER REEE es 24 Airport Security Metal Detectors 24 Rechargeable Auria PowerCels 24 AURA POWerGel NOIRS EEAS EGOE ERIE 25 Charger and Power Supply 222222 25 Light Emitting Diode LED Indicators 2 25 Charging the Auria PowerCels 26 Assembling the Charger 1 24 2454 dessertes sde 26 Inserting the Auria PowerCels
2. Auria User Guide RevC qxp 6 15 07 10 06 AM Page 1 Qi Table of Contents Mirodenii ee en ere 4 a on ee ca 5 Part I Using your HiRes Auria Processor 7 OVEIVICW ORA IEE eee AE EE E E E E A AE 7 HiRes Auria Processor Components 7 HiRes Aung Processor RL aa nn ane oc deco did 7 AMC DOS teeoouhecseasewstheuseetesennseeeas 8 PAG CO MS a E crete none ess 8 VOLS PI a ee nn 8 Auria Headpiece with Attached Cable 22 9 Conneding the HiRes Auria Headpiece to the HiRes Auria Processor 9 Removing the HiRes Auria Headpiece from the HiRes Auria Processor 9 Auria Accent Color Covers and Headpiece Caps 9 Sara ee EE DUONG acts t se teece conse a ee 10 Standard Earhook 11 UE ATOM PA E T dos aues E E E I ET ET 11 Auria Direct Connect 11 PONG A Ge A ay eee ene Hesse eesun 4 suk eed eee ener T 13 Aung MCR toca aca te ecaeinneen 14 SO ete aoa A O E EE 16 Rechargeable Auria PowerCel 22 16 Check Auria PowerCel Charge and Lock Status 17 Replacing the Auria PowerCel 17 Auna PONS a io 17 To Connect the Auria PowerPak
3. Volume Dial Operation i N The volume dial can be used to control the loudness D cr nse Incrense level of a program To adjust the volume TAUN e Turn dial clockwise using the side of your index finger to increase volume e Turn dial counterclockwise using the side of your index finger to decrease volume NOTE Usually your audiologist will set the 12 o clock position on your volume dial as your most comfortable listening level The volume position is indicated by the white dot located on the dial CAUTION To avoid overly loud sounds please remember to turn the volume dial down prior to placing the HiRes Auria Headpiece over the implant 8 AURIA User Guide A LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 9 Sy Auria Headpiece with Attached Cable The headpiece contains the transmitter for sending sound information to the implant The headpiece is held securely in place over the implant by magnetic attraction It is designed with smooth rounded surfaces of lightweight materials to provide comfort for users of the HiRes Auria Processor The headpiece cable connects the HiRes Auria Processor just below the program switch FIGURE 4 HiRes Auria Processor with Connection to Attached Headpiece and Cable Connecting the HiRes Auria Headpiece to the HiRes Auria Processor e Align the raised area on the end of the cable s strain relief with the groove on the cable connector on the body of the proc
4. Do not substitute cables with unknown properties without first consulting the implant care professional or Advanced Bionics e When specific setting recommendations have been made by the audio appliance manufacturer and or Advanced Bionics they have been made under specific conditions e Long cables tend to become tangled around objects Take care when draping long patch cables across busy areas at home and at work e Some audio appliances were designed in such a fashion that plugging a cable into the audio output earphone port will disconnect the main speaker Thus others may not be able to hear the stereo while you are connected using your specially manufactured patch cable e Proper care of the patch cable i e avoid sharp bending of the cable will maximize its life amp AURIA User Guide 33 CIN ey Auria User Guide RevC qxp 6 15 07 10 06 AM Page 34 i Part IV Troubleshooting Your HiRes Auria Processor The following is a description of how to troubleshoot your HiRes Auria Processor If a problem persists after trying the suggestions below contact your implant center service center or Advanced Bionics for support No Sound Heard Ensure that the cable is inserted into the HiRes Auria Processor and the Auria Headpiece is properly positioned over the implant site Ensure that you are using a charged Auria PowerCel If the Auria PowerCel is charged e Try the Auria T Mic using a program that allo
5. an auxiliary only program while using the Auria T Mic NOTE When fitting the Auria T Mic over the ear bend by placing finger near the microphone and pushing gently Avoid sharp angles 90 or greater as it can shorten the lifespan of the Auria T Mic FIGURE 7 Auria T Mic 3 Auria Direct Connect The Auria Direct Connect Earhook allows you to connect to auxiliary audio input devices such as a CD player or FM systems It requires the use of the Auria Direct Connect Cable and audio interface cable NOTE Consult with your audiologist for the appropriate audio mixing ratio settings FIGURE 8 Auria Direct Connect Cable to HiRes Auria Processor AURIA User Guide 11 A LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 12 Qi Auria Direct Connect Cable This cable comes in 3 different lengths and is designed to connect to a variety of assistive listening devices such as FM Systems Infrared Systems and CD Players These audio sources typically require a custom made patch cable available either from the manufacturer of these devices or from an electronics store The cable has a 3 5mm stereo audio jack at one end and a custom miniature connector at the other end that plugs into a connector on the top of the earhook With or without the Direct Connect Cable attached the quick disconnect earhook mechanically functions as a standard earhook therefore you can attach an earmold with standard tubing to the end of t
6. information With the HiRes Auria Processor it is possible to adjust the level of input from the FM receiver and from the HiRes Auria Processor micro phone Your implant audiologist can select a variety of audio mixing options depending on the individual needs on a program by program basis Audio mixing capabilities provide the option of how much sound in percentage is received from different microphone sources The default audio mixing ratio for the HiRes Auria Processor is 50 50 If applicable your audiologist will set the FM system output gain and tone controls per the FM manufacturer s recommendations prior to FM use Operating Instructions If applicable to the FM system chosen e Set the FM volume control of the FM receiver to the minimum setting e Set the volume dial of the HiRes Auria Processor to the user s typical settings e In sequence turn on the FM transmitter then receiver and finally the HiRes Auria Processor in that order e Increase the FM gain volume control to a comfortable listening level 30 AURIA User Guide aX ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 31 Qi Troubleshooting Tips e Ensure that the appropriate patch cable for the make and model of FM system is being used Do not substitute cables with unknown properties without first consulting your implant care professional Advanced Bionics or the FM manufacturer e Proper care of the patch cable i e avoid sharp ben
7. input While you may not be able to find a patch cable for all audio devices such as CD players tape recorders etc At an audio appliance outlet there are a number of third party vendors that can provide an appropriately made cable for your needs Please contact Advanced Bionics for a list of these vendors 32 AURIA User Guide A ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 33 i e Ensure that the appropriate patch cable has been obtained for the make and model of audio appliance i e CD player Walkman and HiRes Auria Processor e With the audio appliance in the off position and the processor turned down attach the appropriate ends of the patch cable to their respective input output sockets The ends of the cable should be appropriately marked as the attenuated end of any cable should be closest to the processor e If applicable to the audio appliance set any volume and tone controls per the manufacturer s recommendations e Set the volume dial of the audio appliance to the minimum setting e Set the volume dial of the HiRes Auria Processor to the typical use settings e Turn on the audio appliance and turn up the processor in that order e Increase the volume dial of the audio appliance to a comfortable listening level or to a specifically recommended level by the manufacturer Troubleshooting Tips Ensure that the appropriate patch cable for the make and model of the audio appliance is being used
8. into the Charger 27 Removing the Auria PowerCels from the Charger 28 Cleaning the Charger 442422222222 28 Using the Battery Charger Car Adapter 29 Part Ill Assistive Listening Devices 30 OVE ohn ook ac genene ene dares erate a7 645 eee pon E eons saaeeeys 30 Parsona FM yS OMS bh ames a D do os 30 Operating Instructions 30 OUbI S ROIS kee eye EEST ETEN pean aaa 31 Infrared Systems 31 Opergting INSmelOnS sn dia eseusdad sir tes coca liant 31 Troubleshooting TIBS 4 5444 asnessseiest suessssetti 32 Hardwired SYSTEMS 5 244 44 audios eaues ta diadiseheesebtodariletehses 32 Operating Instructions 22 Troubleshooting TES A es dans has do ide con 0 33 Part IV Troubleshooting your HiRes Auria Processor 34 No Sound Hedrd REP cee spores hae rrain EE EE ENEEIER riers eas 34 e SCO eea pd De EE E E dan 34 Muffled or Distorted Sounds Heard 34 Auria Headpiece Cap or HiRes Auria Processor Gets Wet 35 Red Light Emitting Diode on the Charger 35 No Green LED orn the Charger issus 2 ede reked Eiir 35 Pro
9. provided with each HiRes Auria Processor The wallet allows you to carry an additional Auria PowerCel safely and conveniently in your pocket or in your purse Charger and Power Supply The charger provided with the HiRes Auria Processor is designed to recharge up to four Auria PowerCels simultaneously It takes a little over 4 hours to fully recharge an Auria PowerCel depending upon size of Auria PowerCel used Slim vs Plus NOTE Auria PowerCels do not need to be fully depleted before recharging CAUTION Only use the charger for charging Advanced Bionics Auria PowerCels DO NOT use it to charge other batteries Do not try to charge Auria PowerCels using a charger other than the one supplied by Advanced Bionics Light Emitting Diode LED Indicators A green light next to the power supply socket illuminates when the charger is con nected to a power source and indicates power flowing to the unit There are 8 light indicators along the side of the charger 2 for each battery slot The amber light is located next to a lightning bolt symbol W It lights up when charging is in progress at that particular battery slot Once the battery is fully charged the light will be turned off A red light is located next to an exclamation mark When it lights up it indicates that the PowerCel should be replaced amp AURIA User Guide 25 CT YY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 26 ql Charging the Auria Power
10. turn off amp AURIA User Guide 27 aX LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 28 Sy NOTE If you place a partially charged Auria PowerCel in the charger the Auria PowerCel may be fully charged in a shorter period of time You can remove the Auria PowerCel at any time The charger and Auria PowerCels will not be damaged if the Auria PowerCels remain in the charger longer than the required charging time It is a good idea to rotate the Auria PowerCels in daily use in order to maximize Auria PowerCa life You must recharge your Auria PowerCels at least once every 3 months even if you are not using them Removing the Auria PowerCels from the Charger Gently slide the Auria PowerCel out of the slide tracks of the charger FIGURE 29 Removing the Auria PowerCel from the Charger Cleaning the Charger The rechargeable Auria PowerCels and charger contacts should be kept free from dirt and dust Dirty contacts can result in charger malfun ction Gently clean the contacts with a hearing aid brush or dry cotton swab being careful not to bend the contact pins This should be done at least once a month If the charger or power supply is dropped inspect it for evidence of damage or cracking If any evidence of damage is seen the charger or power supply should be replaced Prior to use inspect the charger cable to ensure that it is not frayed or damaged and that the plug is not broken If your power cord appe
11. 500 Fax Email asiapacific advancedbionics com Technical information will be provided upon request Advanced Bionics CLARION HiRes Auria T Mic FireFly Auria PowerCel Auria PowerPak and CII BTE are trademarks of Advanced Bionics Corporation in the United States of America and other countries This device is protected under one or more of the following U S Patents 4 400 590 4 405 831 4 495 917 4 686 765 4 721 551 4 819 647 4 837 049 4 931 795 4 969 468 4 990 845 4 991 582 5 443 493 5 477 855 5 513 793 5 522 865 5 531 774 5 545 191 5 569 307 5 571 148 5 584 869 5 601 617 5 603 726 5 609 616 5 626 629 5 738 270 5 776 172 5 833 714 5 876 425 Other U S and or foreign patents are pending 9055126 001 Rev C AURIA User Guide 37 aX ae Auria User Guide RevC qxp 6 15 07 10 04 Ne KAM Page 38 L 38 AURIA User Guide CT ey Auria User Guide RevC qxp 6 15 07 10 06 AM Page 39 Qi amp AURIA User Guide 39 CT ey Auria User Guide RevC qxp 6 15 07 10 04 Ne NAM Page 40 y 40 AURIA User Guide A ey
12. Auria User Guide RevC qxp 6 15 07 10 06 AM Page 36 i Problems with Adherence of the Auria Headpiece Cap to the Head e Discuss the possibility of increasing magnet strength with your audiologist Maintaining Stability Behind the Ear e Depending on the earhook option used an earmold or commercially available huggie may provide additional security for the processor on the ear Please consult your implant audiologist for their recommendation 36 AURIA User Guide CIN ey Auria User Guide RevC qxp 6 15 07 10 06 AM Page 37 Re Part V Contact Us Advanced Bionics is committed to providing the highest quality products and service to our customers We welcome your comments about the HiRes Auria Processor or your suggestions to improve the product Please feel free to contact Advanced Bionics or discuss your suggestions with your implant professional Corporate Headquarters Advanced Bionics Corporation 12740 San Fernando Road Sylmar California 91342 U S A 800 678 2575 within US and Canada 661 362 1400 661 362 1500 Fax 800 678 3575 TDD www advancedbionics com Email info advancedbionics com European Headquarters Advanced Bionics SARL 76 rue de Battenheim 68170 Rixheim France 33 0 3 89 65 98 00 33 0 3 89 65 50 05 Fax p Email europe advancedbionics com P Asia Pacific Advanced Bionics 25129 Rye Canyon Loop Valencia California 91355 U S A 661 362 1400 661 362 1
13. Cels The following section describes assembling the charger and inserting the rechargeable Auria PowerCels in the charger Assembling the Charger Place the charger on a flat surface FIGURE 24 Charging Bay on Flat Surface Select the power plug appropriate for your location FIGURE 25 Power Supply Adapters Connect the power plug to the power supply FIGURE 26 Connecting the Adapters to the Power Supply To Outlet Connect the cable from the power supply to the charger 26 AURIA User Guide CT WY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 27 Sy FIGURE 27 Connecting the Power Supply to the Charger To Charger Insert the power plug into the wall outlet A green light indicates proper connection Inserting the Auria PowerCels into the Charger Locate the slide tracks on the charger FIGURE 28 Inserting Auria PowerCel into the Charger Position the Auria PowerCd so that the contact is facing the top wall where the pins reside Slide the Auria PowerCel onto the charger until it engages You can insert up to four Auria PowerCels in the charger at one time The charger is designed so the Auria PowerCels can only be inserted in one direction Auria PowerCds will start charging automatically The amber light indicator will illuminae to signal that charging is in progress When the Auria PowerCe is fully charged the light for that particular Auria PowerCd will
14. G Small Parts Hazard Parents and caregivers should be counseled that the extemal implant system contains small parts The Auria Accent Color Covers Auria Accent Color Headpiece Caps the metal contact on the inside of the headpiece cap and earhooks may cause choking if swallowed FIGURE 6 Removal of HiRes Auria Processor Accent Color Cover Earhook Options NOTE Use of the various earhook accessories may require different audio mixing ratios Please consult your audiologist for evaluation of the most satisfactory mixing ratio and subsequent programming adjustment for the earhook in use Four earhook options are available to support your HiRes Auria Processor 10 AURIA User Guide de Auria User Guide RevC qxp 6 15 07 10 06 AM Page 11 ar 1 Auria Standard Earhook When using the Auria Standard Earhook the microphone located at the top of the processor is the input source to the processor An earmold may be used with the standard earhook to provide added security of the processor on the ear 2 Auria T Mic The Auria T Mic is an integrated earhook and microphone combination The microphone is omni directional accepts sound from all directions and is designed to fit in the open bowl portion of your ear The Auria T Mic is appropriate for everyday use and may provide added benefit in difficult listening situations such as in noisy environments or on the phone For the best results some listeners may require
15. Part Il Care and Maintenance of your HiRes Auria Processor Overview Although your HiRes Auria Processor has been designed and built to withstand daily wear and tear care must be taken to protect the ext e mal components of the device For a detailed discussion of warnings and precautions please refer to the Package Insertlocated at the back of this guide It is a good idea to carry the User Identification Card with you at all times Cleaning If necessary the HiRes Auria Processor and Auria Headpiece can be cleaned with a slightly dampened cloth or tissue Take care that water does not drip into any con nectors or the microphone Water or other fluids should never enter the HiRes Auria Processor or the Auria Headpiece CAUTION Immersion in water will damage the HiRes Auria Processor and Auria Headpiece electronics To prevent intermittent operation of the processor the Auria PowerCel contacts on the rechargeable Auria PowerCel and HiRes Auria Processor should be kept free from dirt dust perspiration or moisture Gently clean the contacts with a hearing aid brush or dry cotton swab being careful not to bend the contact pins This should be done at least once a month and immediately after exposure to moisture or perspiration HiRes Auria Processor Protection Your HiRes Auria Processor contains advanced electronics that can be damaged Care should always be taken when using or handling If you drop your processor check that it is fu
16. PowerCel Plus CI 5540 Auria PowerCel Charger Bay CI 5600 Auria PowerCel Charger Power Supply CI 5610 Auria PowerCel Charger Power Supply Adapters CI 5630 Auria PowerCel Wallet CI 7115 Auria User Video 7095544 00 1 Auria Carrying Case CI 7420 Auria Travel Case Cl 7420 002 System Sensor CI 5820 Auria T Coil CI 5750 4 AURIA User Guide CT ey Auria User Guide RevC qxp 6 15 07 RO Page 5 Labeling The symbols below are used on the labeling for the product and for transportation and their meanings are as follows CAUTION Federal law restricts this device to sale distribution and use by or on the order of a physician European Community Mark of Conformity Authorized to affix the CE Mark in 2003 REF Model Number Serial Number store at ae 7 fe temperatures between 0 C and 50 C Date of ragile xx xxxx Manufacture mn Type of ere OL ve rat R Protection BF o not get we EN6060 1 1 Classification Information Ordinary Construction Continuous Operation AURIA User Guide 5 Auria User Guide RevC qxp 6 15 07 10 06 AM Page 6 Qi 6 AURIA User Guide CT ey Auria User Guide RevC qxp 6 15 07 10 06 AM Page 7 ar Part I Using your HiRes Auria Processor Overview The HiRes Auria Processor is a small lightweight behind the ear sound processor designed to work with the most advanced technology in sound process
17. PowerPak 18 FIGURE 21 HiRes Auria Processor with Huggie sss 19 FIGURE 22 Auria Carrying CaSe et nupeont 23 FIGURE 23 Auria Carrying Case Dri Aid Insert sus 24 FIGURE 24 Charging Bay on Flat Surface sens 26 FIGURE 25 Power Supply Adapters iii 26 FIGURE 26 Connecting the Adapters to the Power SUpply ss 26 FIGURE 27 Connecting the Power Supply to the Charger 27 FIGURE 28 Inserting Auria PowerCel into Charger 27 FIGURE 29 Removing the Auria PowerCel from the Charger 28 FIGURE 30 Battery Charger Car Adapter issus 29 amp AURIA User Guide 3 CT ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 4 Qi Introduction The User Guide provides information on the use and maintenance of the HiRes Auria Processor HiRes Auria Processor Kit Contents The following items may or may not be included in your HiRes Auria Processor Kit Please refer to the contents list for the actual contents of your kit HiRes Auria Processor CI 5230 Auria Headpiece CI 5304 Auria Standard Earhook CI 5730 Auria T Mic CI 5830 Auria Direct Connect CI 5840 Auria Direct Connect Cable CI 5841 Auria FireFly CI 5720 Accent Color Covers Auria PowerCel Slim CI 7120 Accent Color Covers Auria PowerCel Plus CI 7121 Accent Color Covers Auria PowerPak CI 7122 Auria Accent Color Headpiece Cap CI 7123 Auria PowerPak CI 7400 Auria Huggie CI 7450 Auria PowerCel Slim CI 5520 Auria
18. Touching TV or computer screens e Removing bedding materials You should take the following basic precautions in order to reduce ESD to your processor system e Static electric potential can be safely reduced by touching any person or object with your fingers prior to that person or object contacting a headset cables or sound processor Hand contact will safely equalize electric charge and prevent sparks from jumping to the processor system When approached by someone for example on carpet touch him or her first with your hand prior to them touching your etemal components Parents are advised to touch their child before they touch a headset or sound processor that their child is wearing Also before placing any part of a proces sor system on a table or other surface you should first touch the surface Avoid contact between your processor cables headpiece and metal surfaces before you touch the metal surface with your hand This is particularly important on the playground where high levels of static electricity can be easily generated and extreme electrostatic discharge events can occur between a headset or sound processor and metal that supports the playground equipment A plastic tubular slide for example will quickly charge a child who then often immediately runs to a metal support structure such as a ladder If at all possible teach children who wear cochlear systems to touch with hands first e Carefully exit motor vehicles par
19. Your audiologist will indicate when you should begin to use the telephone with your HiRes Auria Processor You can use the telephone by placing the receiver directly over the microphone located in the earhook of your HiRes Auria Processor or directl y over your ear when wearing the Auria T Mic You may find the Auria T Mic beneficial for you in particularly noisy situations Practice with several phones some with adjustable volume to find what works best for you Initially you may want to practice using the telephone with your audiologist or a familiar person Be patient Telephone communication with the implant often improves over time as you gain experience using the device Using or being in the vicinity to someone who is using certain digital cellular phones may cause interference with the cell phone s reception or problems with the quality of sound from your device If such interference occurs you can remove your HiRes Auria Processor or move away from the source Before purchasing a digital cellular phone you should evaluate whether or not interference is present GSM cellular or cordless phones create the most audio interferences and may require a remote adapter that can be obtained from the cell phone company No such interference has been noted with cellular phones that use older analog technology or CDMA digital service 20 AURIA User Guide CIN ey Auria User Guide RevC qxp 6 15 07 10 06 AM Page 21 i
20. age the implant or processor However the implant system may activate the detector alarm or users may hear a distorted sound when passing through a security door or during a hand held wand scan Turning the processor volume down will ensure that any sounds heard are not too loud or uncomfortable Rechargeable Auria PowerCels When you are not using your HiRes Auria Processor you should remove the rechargeable Auria PowerCel Auria PowerCel capacity decreases with age and usage This is normal for all recharge able Auria PowerCels and should not be considered a defect 24 AURIA User Guide aX ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 25 i If the rechargeable Auria PowerCel is dropped look at it for evidence of damage or cracking If any evidence of damage is seen the Auria PowerCd should be disposed of immediately WARNING The Auria PowerCel used in this device may present risk of fire or chem ical burn if mistreated Do not dissemble heat above 100 C 212 F or incinerate Dispose of used Auria PowerCels appropriately Never put PowerCels in mouth If swallowed contact your physician or local poison control center immediately WARNING To prevent injury or burns due to a short circuit do not allow metal objects such as keys or coins to contact the battery terminals Auria PowerCel Wallets are provided to carry and protect the batteries Auria PowerCel Wallet An Auria PowerCel Wallet is
21. ars to be damaged it should be replaced 28 AURIA User Guide aX LY Auria User Guide RevC qxp 6 15 07 10 96 AM Page 29 ie Using the PowerCel Charger Car Adapter AB 5620 002 After inserting the car adapter into your car s cigarette lighter connect the cable from the car adapter to the charger FIGURE 30 ocar s ce cigarette lighter AURIA User Guide 29 Auria User Guide RevC qxp 6 15 07 10 06 AM Page 30 i Part Ill Assistive Listening Devices Overview Assistive listening devices such as FM systems and Infrared systems can help to improve speech understanding particularly in difficult listening situations These devices reduce the effect of distance between the sound source and the listener Personal FM Systems The HiRes Auria Processor can be used with a personal FM system by connecting the FM system to the Auria Direct Connect Cable While some FM systems require a custom patch cable other FM receivers may connect to the Auria Direct Connect Cable without use of an additional patch cable It is important to obtain the appropriate patch cable for the processor type and FM type The use of a patch cable other than those specified by either Advanced Bionics or the FM manufacturer may cause degradation of the audio signal sent to the processor FM systems use a radio frequency link between the transmitter and the receiver in order to transmit
22. blems with Adherence of the Auria Headpiece Cap to the Head 36 Maintaining Stability Behind the Ear 22 36 Part V Contact Us 37 2 AURIA User Guide CT ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 3 Re Table of Figures FIGURE 1 HiRes Auria Processor with Components 7 FIGURE 2 amp 3 Program Switch and Volume Did ss 8 FIGURE 4 HiRes Auria Processor with Connection to Attached Headpiece and Cable sens 9 FIGURE 5 Removal of Auria Headpiece Cap 9 FIGURE 6 Removal of HiRes Auria Processor Accent Color Cover 10 FOURE Auria VIM ennemie nn 11 FIGURE 8 Auria Direct Connect Cable to HiRes Auria Processor 11 FIGURE 9 Auria Direct Connect with mono to stereo adapter for FM use 12 FIGURE 10 Connecting the cable to the Auria Direct Connect Earhook 13 FOURE AO ee rene vena eo oer nnn neve Sen Ce One nr ere 13 FIGURE 12 T Coil snapped corectly in place ss 13 FIGURE 13 A u ria T Coil incorr e ctly attached ss 13 FIGURE 14 A u ria T Coil rotation 14 FOURE To A ra FireFly sesrs nn Ore Oni en nee TO OPE Or PeON Pn Orne 15 FIGURE 16 Removing Auria Earhooks sense 15 FIGURE 17 Replacing Auria Eqrhooks seen 15 FIGURE To OS lags SOS en oe eee een et ene ore ee 16 FIGURE 19 Auria PowerPak with Huggie sn 18 FIGURE 20 Replacing the AA Battery in the Auria
23. ct Earhook align the Auria T Coil as shown in the photograph below figure 11 FIGURE 11 e Gently push the Auria T Coil as straight as possible into the port at the top of the earhook un til it lightly snaps in place figures 12 amp 13 FIGURE 12 FIGURE 13 Auria T Coil T Coil snapped incorrectly attached not correctly in place fu lly engaged on earhook amp AURIA User Guide 13 de Auria User Guide RevC qxp 6 15 07 10 06 AM Page 14 i e The Auria T Coil can be rotated 90 degrees to the left or to the right from its upright position to optimize reception for a given location or device figure 14 FIGURE 14 ENVIRONMENTAL NOISE Telecoils are known to be sensitive to magnetic noise generated by most industrial lighting fi xtures store bank and airport security scanners powertransformers motor starters and monitor screens both fl at panel and CRT s WARNING Small Parts Hazard Parents and caregivers should be counseled that the external implant system contains small parts The Auria T Coil b may cause choking if swallowed NOTE Consult with your audiologist for the appropriate audio mixing ratio settings 4 Auria FireFly The Auria FireF is an illuminated earhook that provides visual feedback of the processor fun ctions and program settings for parents and educctors e The Firefly will blink the number of times that correspond to the program in use i e If program two is in use th
24. ct airflow to the PowerPak causing its temperature to rise In the unlikely event of a PowerPak failure obstruction of airflow could result in a case tempera ture increase of up to 20 C 36 F which could potentially result in a significant burn Parents or caretakers of infants and children should periodically check to ensure that the PowerPak has not accidentally moved from its cor rect placement as a result of normal activities causing airflow to be obstructed particularly when unexpected unusual crying or other behaviors are noted amp AURIA User Guide 17 CT LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 18 Sy FIGURE 19 Auria PowerPak with Huggie To connect the Auria PowerPak e Slide the Auria PowerCel off the processor e Remove color cover e Slide the Auria PowerPak onto the tracks of the processor and push latch up to lock e Place short color cover on processor To disconnect Auria PowerPak e Remove the Auria Headpiece and cable e Remove color cover e Pull latch down to unlock by placing your fingers on either side of the latch or your fingernail in the groove at the bottom of the latch e Slide Auria PowerPak off processor Replacing the Battery in the Auria PowerPak e Unscrew the Auria PowerPak e Remove the battery e Replace battery making sure the negative flat end of the battery is positioned toward the spring in the Auria PowerPak The Auria PowerPak is marke
25. d with a sign to indicate proper direction of the battery FIGURE 20 Replacing the AA Battery in the Auria PowerPak 18 AURIA User Guide A LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 19 ar Using the Auria PowerPak The Auria Huggie can be used to help stabilize the HiRes Auria Processor on the ear while using the Auria PowerPak Preparing your Auria PowerPak for use with the Plug or Huggie To attach the Auria PowerPak Plug or Huggie e Gently push the Auria PowerPak plug or Huggie into open slot at the bottom of the Auria PowerPak e Place screw in top of the plug or Huggie e Using 2 or 1 8 flat blade screwdriver gently tighten the screw on top of the Auria PowerPak adapter e Follow directions for attaching Auria PowerPak to HiRes Auria Processor FIGURE 21 HiRes Auria Processor with Huggie To remove the Auria PowerPak Plug e Loosen the screw but do not remove e Gently push on the screw until the plug is loosened and easy to grasp e Remove the screw e Gently pull the plug out To remove the Auria PowerPak Huggie e Loosen the screw e Gently slide the Huggie out NOTE When the HiRes Auria Processor with Auria PowerPak is not in use be sure to remove the battery from the Auria PowerPak otherwise the battery will con tinue to drain amp AURIA User Guide 19 CT LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 20 Qi Using the Telephone
26. ding of the cable will maximize it s life Infrared Systems Infrared systems use invisible light waves to transmit signals such as speech or music Infrared light is invisible as the wavelength of the signal is beyond the capability of our eyes to see The transmitter emitter uses the infrared light waves to send a signal such as speech or music to an individual wearing a wireless infrared receiver The infrared system may be a small personal system or a system comprised of large panels or light emitting diodes LED and few individual receivers In large group situations these emitters are mounted high on a wall and aimed at the perspective audience Inside of an infrared receiver is an infrared sensitive receiving diode Some infrared receivers have an audio output socket that will allow the implant recipient to patch the signal directly into the audio input socket of the sound processor A specially designed patch cable can be obtained from a variety of sources including the manufacturer of the infrared systems Note that not all infrared receivers have body worn environmental microphones or have an extra audio socket for an auxiliary microphone Thus your audiologist will help select an appropriate mixing ratio between the built in HiRes Auria Processor microphone and the signal from the infrared receiver Operating Instructions e Ensure that the appropriate patch cable has been obtained for the make and model of the infrared system a
27. e FireFly will blink two times e The FireFly will light up steadily if the HiRes Auria Processor is successfully com municating with the implant e The FireFly will blink on and off rhythmically if the HiRes Auria Processor is not communicating with the implant e The FireFy will not blink at all if the Auria PowerCel or Auria PowerPak power supply is depleted or disconnected 14 AURIA User Guide A ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 15 Sy FIGURE 15 Auria FireFly To remove earhooks e Turn the earhook accessories slightly more than a 1 4 turn in either direction until it pops off FIGURE 16 Removing Auria Earhooks To replace earhooks e To replace the earhook accessories e Align the earhook so it is flush with your HiRes Auria Processor e Check to make sure the orange o ring is in place at the base of the HiRes Auria Processor Hold the earhook at the base e Push on until it lightly snaps in place e Gently pull to confirm that it is locked in place NOTE If the orange o ring is missing from your HiRes Auria Processor call Advanced Bionics Customer Service for a replacement The earhooks will not snap into place with out the orng FIGURE 17 Replacing Auria Earhooks amp AURIA User Guide 15 de Auria User Guide RevC qxp 6 15 07 10 06 AM Page 16 Qi System Sensor The System Sensor is a handheld accessory which checks e Auria Sound Proce
28. erCel immediately Drain as much excess water as possible from the processor or headpiece Place the processor and or Auria Headpiece in the Auria Carrying Case immediately Contact your cochlear implant center or Advanced Bionics for further instructions NOTE If your system appears to be working but you experience deterioration in the volume or the quality and clarity of sound contact your implant center audiologist as your processor may need to be reprogrammed IMPORTANT If exposure to fluids is suspected attempt to dry processor in a warm room for 24 hours DO NOT try to speed up the drying process with the use of a microwave oven convection oven or hairdryer as these may further damage the internal electronics WARNING Your processor or headpiece should be serviced only at Advanced Bionics Do not attempt to open or repair the processor Do not continue to use the HiRes Auria Processor if any part of it is damaged Unauthorized opening of the processor or other equipment will void the warranty and may compromise system performance Red Light Emitting Diode LED on the Charger When the red LED at a battery slot lights up it indicates that the PowerCel should be replaced Contact your cochlear implant center or Advanced Bionics for further instructions No Green LED on the Charger e Verify charger is connected to power e Replace power supply adapters and or charger amp AURIA User Guide 35 aX LY
29. essor e Slide in place until secure Removing the HiRes Auria Headpiece from the Hikes Auria Processor Hold the cable s strain relief the plastic plug not the wire and gently pull it away Auria Accent Color Covers and Headpiece Caps The HiRes Auria Processor is designed to allow for changes in accent colors both for the processor and the headpiece Three types of accent color covers are available for the processor based on the power system that you have chosen Auria PowerCel Slim Auria PowerCel Plus or the Auria PowerPak The color caps adhere to the headpiece by magnetic attraction FIGURE 5 Removal of Auria Accent Color Headpiece Cap amp AURIA User Guide 9 CT LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 10 Sy Removing the Auria Accent Color Headpiece Cap e Place index finger underneath Auria Headpiece Cap e Hold cable gently at the base of the Auria Headpiece with one thumb e Slide other thumb under the raised portion of the color cap e Gently pull up Replacing the Auria Accent Color Headpiece Cap e Align color cap with Auria Headpiece e Gently place cap onto the headpiece until it magnetically attracts Removing the Auria Accent Color Cover e Unplug cable e Slide finger between the color cover at the bottom of the processor e Gently pull up and slide forward Replacing the Auria Accent Color Cover e Align the color cover at the top of the processor e Gently push on WARNIN
30. his earhook When programmed appropriately the Auria Direct Connect earhook can function as a standard earhook NOTE When using a mono source such as an FM System you must use a mono to stereo adapter included in the Auria Direct Connect Cable package FIGURE 9 Auria Direct Connect with mono to stereo adapter for FM use To Connect Auria Direct Connect Cable e Remove HiRes Auria Processor from ear e Hold the HiRes Auria Processor by the earhook e Gently push the Auria Direct Connect Cable into the port at the top of the earhook Below is an alternate method for attaching the Auria Direct Connect Cable to the Auria Direct Connect Earhook e Rotate the connector 180 degrees e Approach the Auria Direct Connect at an angle e Snap into place e Rotate the connector 180 degrees to align To Disconnect the Auria Direct Connect Cable e Remove the HiRes Auria Processor from ear e Hold the HiRes Auria Processor by the base of the earhook e Gently pull the Auria Direct Connect Cable from the port at the top of the earhook 12 AURIA User Guide aX ae Auria User Guide RevC qxp 6 15 07 10 0 AM Page 13 FIGURE 10 Connecting the cable to the Auria Direct Connect Earhook Auria T Coil The Auria T Coil provides access to private and public loop systems found in the cinema meeting rooms or in the theater Attaching the Auria T Coil to the Direct Connect Earhook e To place the Auria T Coil on the Direct Conne
31. ing The HiRes Auria Processor is designed with easy to use controls to suit a variety of individual needs FIGURE 1 HiRes Auria Processor with Components Auria Accent Color Headpiece Cap Microphone Volume Dial Processor t Module Attached ae on P Headpiece onnection Fort Cable Rechargeable amp PowerCel Accent Color Cover HiRes Auria Processor Components HiRes Auria Processor The HiRes Auria Processor module houses the operating electronics The headpiece and cable attaches to the cable connection port located beneath the program switch on the back of your HiRes Auria Processor To turn the HiRes Auria Processor on attach the Auria PowerCel or Auria PowerPak To turn it off remove the Auria PowerCel or Auria PowerPak amp AURIA User Guide 7 CT LY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 8 Ly Microphone The HiRes Auria Processor utilizes a forward facing omni directional accepts sound from all directions microphone located at the top of the processor to capture sound input Program Switch The HiRes Auria Processor can store up to three programs The program switch is located below the volume dial on your processor and has three positions to represent each stored program Program 1 switch all the way down Program 2 switch in the middle Program 3 switch all the way up FIGURES 2 amp 3 Program Switch and Volume Dial
32. mize its life Hard wired Systems A hard wired system can be described as any system that provides a direct physical connection between the sound source and the listener Examples of this type of system include the use of the Auxiliary Microphone available through Advanced Bionics pass around microphones with long extension cables and patch cables for use with battery powered appliances such as Walkman and CD players While this type of assistive technology is typically the least expensive and the easiest to implement it has its limitations There is the safety factor of having long cables to trip over and the distance limitation before the audio signal will become degraded due to electrical losses from the long cable lengths Further long cables tend to act as an antenna and if not properly designed and can pick up unwanted signals CAUTION One must not plug AC powered devices e g TV Stereo Computer into the HiRes Auria Processor without the use of an approved patch cable that has electrical surge protection built into its design Ignoring this caution could lead to damage to the sound processor and or to the recipient with unpleasant sensations or sounds Operating Instructions e As with any patch cable one must determine if the hard wired system has a plug that will fit into the audio socket of the processor The HiRes Auria Processor uses a standard 3 5mm socket The audio socket of the processor is designed to accept a stereo
33. nctioning properly If you suspect that your processor has been damaged contact your cochlear implant center Avoid the following e Dropping the HiRes Auria Processor e Wearing the HiRes Auria Processor while bathing showering or swimming e Exposing the HiRes Auria Processor to extreme temperatures below 32 F 0 C or above 115 F 45 C e g a closed car on a hot day or near a heater or radiator amp AURIA User Guide 21 aX ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 22 i Electro Static Discharge Your Hi Res Auria and its attachments are designed to withstand most static events without damage or interruption to your programs However there is a chance that high levels of static electricity will generate extreme electrostatic discharge events that may damage the electronic components such as the ones used in the cochlear implant systems Therefore care should be taken to avoid exposing the headpiece cables or sound processor to situations in which high levels of static electricity are created Electro Static Discharge ESD is present when you feel a spark jump from your body ESD events are more likely to occur in very dry or cold environments ESD events are less common in humid areas High levels of electro static charge are known to build up under the following circumstances e Walking on carpets e Sliding on plastic slides e Exiting an automobile e Pulling sweaters on and off e
34. nd the HiRes Auria Processor e With the infrared system and processor in the off position attach the appropriate ends of the patch cable to their respective input output sockets e Set the infrared volume dial of the receiver to the minimum setting e Set the volume dial of the HiRes Auria Processor to the user s typical use settings e In sequence turn on the infrared system transmitter receiver and processor in that order e Increase the infrared system volume dial to a comfortable listening level or to a specifically recommended level by the infrared system manufacturer amp AURIA User Guide 31 CT ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 32 Qi Troubleshooting Tips e Ensure th at the appropri ate patch cable for the make and model of infrared system is being used Do not substitute cables with unknown properties without first consulting Advanced Bionics or the infrared systems manufadurer e When the infrared systems manufacturer and or Advanced Bionics have made specific setting recommendations they have been made under specific conditions e Certain environmental conditions such as the presence of large objects blocking the pathway of infrared systems light from the infrared systems transmitter to the infrared systems receivers can cause interference Consider moving to another location in the environment e Proper care for the patch cable i e avoid sharp bending of the cable will maxi
35. ri Aid kit so you can carry your Auria with you and remove excess moisture as you store it at night Dri Aid Function Your Auria Carrying Case acts as a Dri Aid kit The insert of the Auria Carrying Case contains silica crystals that can be regenerated On the bottom of the Carrying Case insert is a semi transparent window that will allow you to observe the silica crystals as they absorb moisture The crystals are a yel low gold color when dry but turn green as moisture is absorbed When the crystals are green regenerate See Regenerating the Dri Aid Function for instructions amp AURIA User Guide 23 CT ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 24 i Regenerating the Dri Aid Function Remove the insert Figure 23 from the Auria Carrying Case and place on a cookie sheet in a heated oven 200 F 93 C for approximately 1 2 to 2 hours FIGURE 23 CAUTION Do not put the outer case or the Auria and any of its accessories in the oven only the insert is designed to be heated CAUTION Do not heat over 260 F 1 26 C or the silica crystals may become damaged Cleaning If necessary the Auria Carrying Case can be cleaned with a slightly dampened cloth or tissue Do not use soap or solvents CAUTION Do not immerse the Auria Carrying Case in water as it may damage or destroy the silica crystals Airport Security Metal Detectors Metal detectors x ray machines and security scanners will not dam
36. ssor communication with the implant The Auria does not need to be removed before testing its functionality Simply hold the tip of the System Sensor very close to the headpiece depressing the button on the Sensor The Sensor will then display various colored LED patterns refer to chart below The System Sensor is functional if the orange light illuminates when the button is depressed The green light is diagnostic of the Auria s communication with the implant FIGURE 18 Green LED Orange LED Outcome On On Blinks few seconds Auria establishing communications link lock with Implant Blinks continuously On Troubleshoot Processor not locked with implant Contact your implant center audiologist Off On Replace Auria PowerCel Off Off System Sensor needs replacing Rechargeable Auria PowerCel A custom lithium ion rechargeable Auria PowerCel powers your processor The rechargeable Auria PowerCel is available in two sizes Slim and Plus with different operating and charging times 16 AURIA User Guide aX YY Auria User Guide RevC qxp 6 15 07 10 06 AM Page 17 Sy Check Auria PowerCel Charge and Lock Status In order to check the Auria PowerCel charge and lock status in children observe the status of the Auria FireFly refer to Auria FireFly description under Earhook Options Replacing the Auria PowerCel e Slide the Auria PowerCel forward while gently holding the processor and color cover e G
37. ticularly in dry cold weather Try to avoid contact between processor system components and any vehicle metal as you exit 22 AURIA User Guide aX ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 23 i e When possible remove your external equipment prior to removing sweaters e The screens of televisions and computer monitors are highly charged and contact is a problem for two reasons First the charge on screens can cause sparks Second brushing or touching a screen can transfer charge that will then discharge when you come in contact with another object or person e Use fabric softener when washing clothes and bedding this will reduce the like lihood of charge generation If you strip a bed while wearing a processor system please remember to use your hands to safely reduce any charge buildup you may have acquired REMEMBER Touch with hands first Auria Carrying Case The Auria Carrying Case Figure 22 is included in your HiRes Auria Processor kit and is a multi functional case that can carry all your basic Auria components It will hold an Auria processor with either battery or huggie attachment and any earhook There is a place for the headpiece that contains a plate that attracts the headpiece magnet There are also compartments that will hold the AA PowerPak or other accessories and additional earhooks FIGURE 22 The Auria Carrying Case contains a removable insert that also serves as a D
38. uide the Auria PowerCel onto the tracks on the HiRes Auria Processor e Slide the Auria PowerCel onto the processor until it stops and the Auria PowerCel and the processor are aligned NOTE Do not force the Auria PowerCel onto the processor The Auria PowerCel is designed to be inserted in only one direction Forcing the PowerCel may jam or damage the tracks NOTE To prevent damage to the Auria T Mic be sure to turn it gently out of the way prior to removal of the Auria PowerCel NOTE TO EUROPEAN CUSTOMERS For proper disposal of rechargeable Auria PowerCel modules please return depleted Auria PowerCel modules to the local Advanced Bionics Corporation representative or Advanced Bionics SARL Auria PowerPak The Auria PowerPak offers an alternative to the rechargeable Auria PowerCel The Auria PowerPak can be worn on clothing or on a belt The Auria PowerPak uses one non rechargeable AA battery preferably Duracell or Energizer You may opt to use a rechargeable Nickel Metal Hydride for best performance Inserting a battery into the Auria PowerPak activates the HiRes Auria Processor The battery should be removed when the HiRes Auria Processor is not in use to prevent further depletion of the battery WARNING Follow the recommendations of the battery manufacturer never attempt to charge non rechargeable batteries When in use the PowerPak should not be carried in any type of carry ing case pouch or pocket which could obstru
39. ws auxiliary input e Try the System Sensor if available see page 16 If this resolves the problem place the HiRes Auria Processor in the Auria Carrying Case overnight If there is still no sound heard without the Auria T Mic there may be an issue with the internal microphone You should contact your implant center audiologist Static Heard Clean the battery contacts as well as the contacts on the HiRes Auria Processor Try the Auria T Mic using a program that allows auxiliary input If this fixes the problem place the processor in the Auria Carrying Case overnight If there is still static heard without the Auria T Mic there may be an issue with the internal microphone You should contact your implant center audiologist Muffled or Distorted Sounds Heard Remove any material hat headbands etc which may be covering the HiRes Auria Processor microphone Try the Auria T Mic using a program that allows auxiliary input If this fixes the problem place the processor in the Auria Carrying Case overnight If there is still muffled or distorted sounds without the Auria T Mic there may be an issue with the internal microphone You should contact your implant center audiolo gist Also try switching to another program to see if this resolves the problem 34 AURIA User Guide aX ae Auria User Guide RevC qxp 6 15 07 10 06 AM Page 35 Ly Auria Headpiece or HiRes Auria Processor Gets Wet Remove the Auria Pow