1. increments ENTER and BACK buttons Note Press the arrow buttons to view e DEFAULT screen previous fills or losses and the dates in which Note 3 they occurred e E indicates that the system believes that a Cost C Percentage a e By pressing the ENTER button at any of Mack the tank is empty S a these logs you will be directed to a cost _ gt O Q Mack e Lo indicates that there is less than 5 ORONO o g eae and adie a ere days of fuel remainin e volume of fuel which has been adde or lost in that particular EVENT e FULL indicates that the fuel level is less 9 A a than 150mm from the i Track Transmitter b Litres a d kgCO2 a e To update the cost of fuel press and hold the ENTER button on the at the top of the tank E a cost screen until it begins to flash OROORO ROO l Use the arrow buttons to update the latest fuel costs e Press ENTER again to accept the changes made 3 Percentage Remaining screen iT1000 amp iT9000 6 Remote Diagnostic screen iT1000 amp iT9000 8 Reseting the device iT1000 amp iT9000 e 24 hour clock r e Time elapsed since last received a reading gt In order to make extreme changes to the date or alter the tank shape height or e Temperature at the indoor unit in C in minutes e g r0 05 indicates that 5 volume you must reset the device This can be achieved by completing the following e Percentage of fue
2. Track wireless oil monitoring system This device will help to show the end user just how much oil they use waste in their homes and highlight the money they can save as a result i Track monitors the volume of fuel in tanks and for the FIRST time gives an accurate measurement of the average usage By adjusting the thermostat and turning radiators up and down in certain areas of the home i Track lets consumers know if they have made a difference to the amount of oil they have consumed and how much it has SAVED them It will also let them know how much harmful CO2 emissions the home is producing By having this device the user can save money by monitoring the changes they make to their home when adjustments are made to the thermostat Safety Guidelines To ensure that you use your product safely and correctly please read the Warnings amp Safety Precautions Caring for our Product and the User Guide sections before using this i Track oil measuring system Please observe the following warning and safety precaution guidelines when setting up and using this product e When installing this system if in doubt always contact a qualified plumbing and heating engineer e Do not immerse the display unit in water or other liquids If liquid is spilt over it dry it immediately e Do not subject either of the units to excessive force or shock e The LCD panel behind the front window is made of glass and may break if the unit is d
3. R tITACK m Intelligent Oi Monitoring System Easy step by step user guide Use the up and down arrows to navigate through the user screens At any stage hold the back button to return to the default screen The default screens Litres Remaining more than 14 days of fuel remaining Days to Empty less than 14 days of fuel remaining When the system calculates this it will then change to the Days to Empty Screen for 2 seconds out of every 20 seconds and beep when this change occurs Pressing simultaneously the ENTER and BACK buttons will disable the beeping until the next midday or another Fill or Loss has occurred 1 Time and Date screen iT1000 amp iT9000 4 Days to Em pty screen T1000 amp iT9000 e Once at default screen hold the ENTER button in and the remote diagnostic screen will appear until the button is released e 24 hour clock X e To have the remote diagnostic screen remain on the display e Temperature at the indoor unit in C 1 Press and hold the ENTER button e No Days of fuel remaining in the tank 2 Press and hold either of the arrow buttons e Fuel remaining bar chart 10 increments 3 Release the ENTER button aS Note 4 Release the arrow button rack Track ORO e E indicates that the system believes that ORO 5 Remote diagnostic screen will remain on the display the tank is empty 6 Press ENTER or BACK to dismiss e Date Day Month and Year e 24 hour clock e Fuel remaining ba
4. l remaining to 2 minutes has passed since it last received a simple steps decimal places message from the transmitter 1 Press and hold the BACK button Fuel remaining bar chart 10 e Fuel storage temperature where the i Track cc 2 Press and hold the DOWN arrow button increments Transmitter is located in C Las 3 Press and hold the UP arrow button Note e Live distance MILLIMETERS between the f O E 4 Press and hold the ENTER button e E indicates that the system believes i Track Transmitter and the fuel level 5 The bar chart on the right hand side will begin to countdown that the tank is empty e Bar chart signifies reception strength 6 Once completed the screen will flash e Lo indicates that there is less than 5 days of fuel remaining Deni te ANS 026 Cente 7 Reset has been completed e To gain access to the remote diagnostic screen hold the BACK button which will bring you to the current default screen Depending on how many days of fuel there is remaining e FULL indicates that the fuel level is less than 150mm from the i Track Transmitter at the top of the tank Once reset press any button to take you to the time and date screen to begin setup again Resetting this device will lose any previously logged data i e Fills or Losses R Irac Introduction Thank you for selecting i Track as your intelligent monitoring system Keeping an eye on your oil consumption has never been easier with the help of the new i
5. ntents of this user manual may not be reproduced without the E permission of the manufacturer FuLL Images shown in this manual may appear different to that of the actual product or display FiLL Nomenclature LoSS uSnd The uSnd notification signals that the ultrasound was unable to take a successful reading for the last 30 minutes or since the remote unit was powered up While the notification is active the base will continue to report the last good reading but will show that it is uncertain by the flashing segment in the bar graph rEnt Or REMOTE notification This signals that the base has not spoken to the remote unit in the last 4 hours or since the base unit has been powered up After the remote has been missing for just an hour the base will enter a scanning mode on its own indicated by the green LED flashing for just over 30 minutes to try and recover the unit It enters scanning mode again after an hour then after 2 4 and 8 hours and continues to scan every 8 hours until it recovers the unit Low Battery If the battery in the base is low the battery icon will flash on the display on all screens except the Remote Diagnostics Easy step by step user guide If the battery in the remote unit is low the rBAt notification will flash on the screen and the battery icon will flash on the Remote Diagnostics screen At extreme temperatures below 10 C the lithium battery in the remote uni
6. r chart 10 increments Note To change the time or date hold the ENTER button while on the time date screen until it begins to flash Then using the arrow buttons scroll to the correct time To change the date continue to hold the arrow button Lo indicates that there is less than 5 longer and as it speeds up it will also change days of fuel remaining through the dates After initial setup the date can only be brought forward 14 days amp back 1 Wnen ihe system calculates tiers eee en case ema 7 Fill Events screen iT1000 amp iT9000 day without resetting the device this becomes the DEFAULT screen e When a Fill or Loss occurs the words FiLL or LoSS will appear on screen along with the FILL segment being highlighted and a BEEP 2 Litres Remaining screen iT1000 amp iT9000 5 Consumption Rate iT9000 Only To accept press and hold the ENTER amp BACK buttons together until the word CLr Mrack There are four different types of consumption calculated appears then release O O COST LITRES PERCENTAGE amp CO2 EMISSIONS e The latest FiLL or LoSS will then appear in alog as either 01 or L 01 respectively along with the date of when it occurred e 24 hour clock e Temperature at the indoor unit in C e Number of litres remaining e Fuel remaining bar chart 10 These are displayed in a Daily Weekly Monthly and Annual rate To alternate between the different rates press the
7. ropped or impacted directly onto e Keep the product away from direct heat sources such as radiators stoves heaters fires etc e Do not tamper with any of the internal components as it will invalidate your warranty e Do not attempt to repair the product yourself Contact a retailer or our customer service department e Take care when handling all battery types Batteries can cause injury burns or damage to property if they come into contact with conducting materials e Remove the batteries before storing for a long period of time e Dispose of batteries correctly in accordance to local waste regulations e When disposing the product do so in accordance with your local waste disposal regulations The Intelligent Oi Monitoring System Cleaning and Caring for the Product To ensure that you receive the maximum out of your product please observe the rBAt following instructions e Display unit remove batteries before cleaning and clean using a damp cloth water Do not use any cleaning agents aerosols or liquids e Outdoor unit wipe down using a damp cloth water e Do not scratch hard or abrasive objects against the display unit as this may cause damage uME e Do not leave discharged batteries in either of the units for any length of time as they may leak and cause corrosion Note The technical specification for this product and the contents of the user Lo manual are subject to change without notice e The co
8. t must work harder in order to deliver the power required to operate the device properly As the battery ages this may cause the device to report a low voltage condition earlier than it would under moderate temperatures The tiME notification indicates that the correct time cannot be recovered Normally if the base resets when it comes back online it will recover the time from the remote unit when it next communicates this may take up to an hour to occur If the remote unit has also reset during this period it will not be possible to recover the time and after the base has communicated with the remote and discovered this fact it will present this notification When the Litres Percentage remaining and Days to Empty screen show Lo it indicates that there is less than 5 days of fuel remaining E indicates when the system believes that the tank is empty If the fuel is closer than 150mm to the remote unit then the percentage and volume screens will just show FuLL This indicates that the fuel level in the tank has increased rapidly and a Fill has occurred You can accept this through entering the Events Screen by pressing the ENTER amp BACK buttons together until it appears This indicates that the fuel level in your tank has dropped rapidly and a Loss has occurred You can accept this through entering the Events Screen by pressing the ENTER amp BACK buttons together until it appears