Home
Magnum PES42P PoE Edge Switches Installation and User Guide
Contents
1. PES42P PoE Edge Switches Installation and User Guide 07 07 Operating Environment PES42P 40 F to 167 F 40 C to 75 C Long term per agency tests UL 58 F to 212 F 50 C to 100 C Short term per IEC Type tests Storage Temperature PES42P 40 F to 160 F 40 C to 85 C Cold Start PES42P to 40 C Ambient Relative Humidity 5 to 95 non condensing Altitude All models 200 to 5000ft 60 15 000 m Conformal Coating optional for humidity protection Note PES42P models are designed for NEBS compliance including vibration shock and altitude Packaging Enclosure Rugged sheet metal Steel Dimensions of the Switch unit www GamettCom com TT 3 PES42P PoE Edge Switches Installation and User Guide 07 07 3 7 in H x 3 0 in W x 1 7 in D 9 4 cm x 7 6 cm x 4 3 cm Weight all models 9 5 oz 285g Power supply d and i 5 8 oz 165g Hd and Hi 5 8 oz 165g Pd and Pi 7 9 oz 225g Cooling Method Convection cooling is used for the office model The hardened H factory floor and premium P temperature un controlled location models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling ALARM RELAY Terminal Block H and P models only two screw terminals Internal 60V A relay contact Open for power Off closed for power On Hardware AC POWER SUPPLY using an external power adapter All models h
2. Ports Performance When a port is operating at 100Mbps Data Rate 100Mbps When a port is operating at 10 Mbps Data Rate 10 Mbps Network Standards 100Mb Ethernet IEEE 802 3u 100BASE TX I00BASE FX 10 Mb Ethernet IEEE 802 3 IOBASE T Auto sensing for speed IEEE 802 3u Packet Processing Between Domains Filter and Forward Rate from 100Mbps ports 148 800 pps max Filtering and Forwarding Rate from 10 Mbps ports 14 880 pps max Processing type Store and Forward non blocking Auto learning 2K address table www GamettCom com 00 l PES42P PoE Edge Switches Installation and User Guide 07 07 Address buffer age out time 300 sec Packet buffers memory 128KB dynamically shared on all domains Latency not including packet time 100 to 10 Mbps Sus 10 to LOOMbps l5us Path Delay Value 50 BT on all ports LLL Link Loss Learn Factory default is activated on port 1 and 2 allow to flush the internal address buffer and qualify to use with S Ring and RSTP for faster recovery in ring topology Maximum Ethernet Segment or Domain Lengths IOBASE T Unshielded twisted pair 100 m 328 ft 1OOBASE TX CAT 5 UTP 100 m 328 ft 1OOBASE FX half duplex multi mode 412 m 1350 ft 1OOBASE FX full duplex multi mode 2 km 6 562 ft 1OOBASE FX half duplex single mode 412 m 1350 ft 1OOBASE FX full duplex single mode 20 km 65 620 ft 1OOBASE FX full duplex single mode long reach 40 km 131 240 ft 2
3. CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service 63 PES42P PoE Edge Switches Installation and User Guide 07 07 APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase www GamettCom com TT 64
4. For 100Mb to 100Mb forwarding the latency is 5 microseconds plus the packet time of 100Mb 21 PES42P PoE Edge Switches Installation and User Guide 07 07 2 4 Features and Benefits B Full 100Mb or 10 Mb switching services for high performance Ethernet Magnum PES42P Series PoE Switches provide Fast Ethernet switching on all ports They perform high speed filter forward operations on the traffic giving each port s segment a full 100Mb or 10 Mb of bandwidth B PES42P economical 4 port 10 100 Power Source Switch for PoE devices The compact and robust PES42P PoE acts as a Power plug for all the PoE devices e g CCTV camera VOIP phone digital clock and wireless point through its RJ 45 ports and provides a convenient cost effective power source The two fiber or copper ports 1 amp 2 1s featured with LLL Link Loss Learn and helps in faster recovery for redundant application B Reduces Network Costs and provide economical solution Magnum PES42P Series PoE Switches offer the ideal solution to efficiently and inexpensively connect a Twisted Pair and fiber network with 10Mb or 100Mb and help to expand the Ethernet network in a very convenient and economical way www GamettCom com TT 22 PES42P PoE Edge Switches Installation and User Guide 07 07 B Choice of one or two100Mb Fiber option more efficient Designed as a multi purpose media Edge Switch the 100Mb fiber port allows the user to convert the media from copper to fiber
5. factors are both applied e The 100Mb fiber segment must operate in full duplex FDX mode and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor 3 8 6 Connections to NICs which support Auto Negotiation RJ 45 ports The copper ports of Magnum PES42P PoE Edge Switches will function properly with NICs Network Interface Cards which support Auto Negotiation and the Fast Link Pulse FLP coding for the 100BASE TX signaling system When connecting a NIC to the PES42P Series it may be necessary to reload the NIC drivers on the user device if the NIC has been communicating with a protocol other than 100BASE TX such as IOBASE T When 100Mb operation is agreed and in use the 10 100 LED is illuminated steady ON and is OFF if 10 Mbps traffic is in use www GamettCom com j 47 PES42P PoE Edge Switches Installation and User Guide 07 07 3 8 7 Mounting Dimensions for PES42P with metal brackets Each Mangum PES42P PoE switch is supplied with metal mounting brackets and screws to mount the unit securely on a panel or wall It is recommended to mount the units vertically as shown below for proper cooling and long life reliability It is also advisable to mount the unit with space for air movement around the top and the sides typically a minimum of 1 inch Note that the metal brackets supplied hold the back of the PES42P
6. impose minimal frame latency they will also permit bad frames to propagate to the Ethernet network The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic There is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated Since collisions and bad packets are more likely when traffic is heavy store and forward switch technology enables more bandwidth to be available for good packets when the traffic load is greatest To minimize the possibility of dropping frames on congested ports each Magnum PES42P Series Edge Switch dynamically allocates buffer space from a 128KB memory pool ensuring that heavily used ports receive very large buffer space for packet www GamettCom com 19 PES42P PoE Edge Switches Installation and User Guide 07 07 storage Many other switches have their packet buffer storage space divided evenly across all ports resulting in a small fixed number of packets to be stored per port When the port buffer fills up dropped packets result This dynamic buffer allocation provides the capability for the maximum resources of the Magnum PES42P Series unit to be applied to all traffic loads even when the traffic activity is unbalanced across the ports Since the traffic on an operating network is constantly varying in packet density per port and in aggregate density th
7. packets and enables peak performance to be achieved when there is heavy traffic on the network Switching Address Learning The Magnum PES42P Series units have address table capacity of 2K node addresses and are suitable for use in large networks They are self learning so that as www GamettCom com 92 PES42P PoE Edge Switches Installation and User Guide 07 07 nodes are added or removed or moved from one segment to another the PES42P Series switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor of new frequently used addresses To reset the address buffer cycle power down and up 4 2 Auto cross MDIX Auto negotiation and Speed sensing The RJ 45 ports support auto cross MDI or MDIX in the auto negotiation mode according to the IEEE 802 3u standard No crossover cables are needed on RJ 45 port when connecting the PES42P Series to other unmanaged switches legacy hubs managed switches media converter etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software and the result of the auto negotiation is changed in the managed switch by the manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in the PES42P Series switches will still work The auto cross function cannot be disabled When an RJ 45 cable connection 1s made and each time LINK
8. 1 and 2 is being assigned for copper or fiber port for different models On all copper 10 100 ports model e g PES42P d the LEDs 10 or 100 denotes for copper port only For the model 4copper 2 fiber or 5copper 1fiber e g PESA2PH ff Hd the F or H denotes for fiber port only 4 4 Hardware operated Alarm Contact for monitoring internal power supply The two screws Alarm Contact features are standard on Magnum PES42P Series H and P and provide Normally Closed NC contacts to which the user can attach one sets of status monitoring wires at the green terminal block When this option is present the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum PES42Ps case The DC power input connection is in the same panel 55 PES42P PoE Edge Switches Installation and User Guide 07 07 The NC Alarm Contact is held close when there is power on the main board inside of the PES42P This provides a Hardware operated Alarm because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power supply inside of the Magnum PES42P Series Switches Useful info about Alarm Contacts in PES42P 1 Two position terminal block 1 2 provided next to the DC power input as shown above 2 The Alarm Relay contact connected to the two terminals 1 2 is hardware operated 3 By default it is NC normally closed It will open if there is any loss of power
9. Edge Switches Installation and User Guide 07 07 NOTE t is recommended that high quality CAT 5 cables which work for both 10 Mbps and 100Mbps be used whenever possible in order to provide flexibility in a mixed speed network since PES42P series switch ports are auto sensing for either 10 and I00Mbps Note that the auto cross function does not operate if the port is fixed or not supporting auto negotiation 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shielded The following procedure describes how to connect a 10BASE T or I00BASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with a RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established If this 42 PES42P PoE Edge Switches Installation and User Guide 07 07 does not help ensure that the cable is connected properly and that the device on the other end is powered and is not defective 4 For Port 1 or ISW if the LINK LED is not illuminated move the switch which has a cross over or up
10. GamettCom com 59 PES42P PoE Edge Switches Installation and User Guide 07 07 5 2 When Calling for Assistance Please be prepared to provide the following information l A complete description of the problem including the following points a The nature and duration of the problem b Situations Environment when the problem occurs c The components devices involved in the problem d Any particular application that when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including Convenient computers workstations terminals and printers plus the various network media types being used along with diagram of network setup 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 60 PES42P PoE Edge Switches Installation and User Guide 07 07 5 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Na
11. lead is securely tightened from the top as shown on above picture with arrow NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate 40 PES42P PoE Edge Switches Installation and User Guide 07 07 3 8 Connecting Ethernet Media for PES42P PoE Edge Switch The Magnum PES42P Series PoE Edge Switches can be connected to two media types i e fiber and copper RJ 45 types runt at IOOBASE TX IOBASE T and 100BASE FX only CAT 5 cables should be used when making 100BASE TX connections When the ports are used as IOBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft For fiber port IOBASE FL or 100BASE FX multi mode 50 125 or 62 5 125 microns cabling can be used whereas for single mode 9 125 microns cabling should be used Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 1OBASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode 1OOBASE FX ST SC Fiber Single mode 1OOBASE FX SC LC Fiber Multi mode 100BASE FX MTRJ www GamettCom com 4 PES42P PoE
12. link for linking to another hub or Switch 3 8 2 Connecting Fiber Optic ST type twist lock The following procedure applies to installations using ST type fiber connectors This procedure applies to ports using multi mode ST fiber connectors 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the fiber connectors Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated orts at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum Fiber port to the Receive RX port of the remote device Begin with the color coded strand of the cable for this first TX to RX connection 4 Connect the Receive RX port dark colored post to the Transmit TX port of the remote device Use the non color coded fiber strand for this www GamettCom com 00 TT 43 PES42P PoE Edge Switches Installation and User Guide 07 07 5 The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit after cable connection the normal cause is improper cable polari
13. to the electronics inside of the unit 5 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of Magnum PES42P Series 10 100 Mb s Switches is a straightforward procedure see www GamettCom com 56 PES42P PoE Edge Switches Installation and User Guide 07 07 INSTALLATION Section 3 0 the operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum PES42P Series 10 100 Mb s Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 5 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable www GamettCom com j TT 57 PES42P PoE Edge Switches Installation and User Guide 07 07 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not be
14. tray will hold a few three to eight PES42P Series PoE Edge Switches with their power supplies plugged into power strips not included in the rear area of the tray Metal mounting screws in the bottom front hold the Edge Switches firmly in place The beveled top edge of the units permits the LEDs of each unit to be viewed for operational status even when the units are very close together 3 3 MC14 TR PS9 and MC14 TR PS9X2 for Rack Mounting Media Edges The MC14 TR PS9 and MC14 TR PS9X2 are other options for rack mounting the mix of Magnum 10Mbps and 100Mbps PoE Edge Switches and Media Edges together in a 19 rack mount tray These models come with built in common universal AC power supply rated at 55 watts at 50 C ambient 9VDC output and supporting up to 2 3 Switches for MC14 TR PS9 and 5 units PES42P Series for MC14 TR PS9X2 The MC14 TR PS9X2 Model has two groups of eight units per power supply The power supplies have auto ranging AC input for use worldwide www GamettCom com TT 33 mrn lan a _ c0 3 o gt Installation and User Guide 07 07 The side view lt here is an example of an installation of the model MC14 TR PS9 19 rack mount tray holding a few PES42P s and 14E Media converters each with their power input plugged into the built in common AC power supply in the rear area of the tray AC PS units that come with the office models of the PoE Edge Switch s are not used Because of the thicker s
15. 1s enabled auto negotiation takes place except for legacy products which do not have auto www GamettCom com TT 53 PES42P PoE Edge Switches Installation and User Guide 07 07 negotiation and which go to the default state accordingly The Magnum PES42P Series Switches advertises its capability for 10 or 100 Mbps speed and F H duplex mode and the device at the other end of the cable should similarly advertise respond Both sides will agree to the speed and mode to be used per the IEEE 802 3u standard Depending upon the devices connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed and full or half duplex mode 4 3 Dual LEDs Front panel and side panel Magnum PES42P Series LED Description PWR __ Illuminates GREEN to indicate power applied LK ACT Steady ON for LINK w no traffic blinking for activity per port LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device The Link ports are also represented by LAI LA2 LA3 LA6 Steady On or steady Off indicates no Receive Activity www GamettCom com g 0 54 PES42P PoE Edge Switches Installation and User Guide 07 07 10 100 Steady ON for 100Mb speed OFF for 10Mb speed per port copper ports F H FH1 FH2 Steady ON for Full duplex F D mode OFF for Half duplex H D mode per port For fiber port only NOTE The port
16. PoE unit out from the panel or wall behind it creating a rear space of about 4 inch or lcm This allows air circulation and cooling of the rear part of the case For best cooling of the PES42P Series attach the metal brackets to metal rather than wood or plastic Attaching to metal helps conduct heat away from the PES42P Series through the metal brackets and into the metal support structure www GamettCom com e j 0 48 PES42P PoE Edge Switches Installation and User Guide 07 07 Since the PES42P Series has special internal thermal techniques patent pending to move MOUNTING CLIPS 5 13 MAGNUM ES42 SWITCH MOUNTING www mE PES42P PoE Edge Switches Installation and User Guide 07 07 the heat generated by the electronic components inside into the case the case may be quite warm to the touch during normal operation The unit is mounted using the brackets as shown in the illustration above The spacing for the mounting screws into the supporting wall or panel is a rectangle 12 82 x 5 cm 5 13 x 2 00 inches center to center 50 PES42P PoE Edge Switches Installation and User Guide 07 07 4 0 OPERATION 4 1 Dual Speed Functionality and Switching The Magnum PES42P Series Edge Switches provide SIX switched ports with combination of fiber and copper or copper only The architecture supports a dual speed switching environment with standard auto negotiation capability The switched RJ 45 ports are full or half
17. and the other RJ 45 port can be used as a diagnostic port for more connectivity B Installation is Plug and Play operation is transparent to software The Magnum PES42P Series PoE Switches operate as hardware switches only forwarding those packets from each domain that are needed on the other domains Internal address tables are self learning enabling users to change port connections or 10 100 domains without affecting operations B Two sets of LEDs for viewing status from any angle Each PES42P Series PoE Edge Switch is equipped with two sets front and side of LEDs to provide status information when viewed at almost any angle or mounting arrangement whether rack MC14 Tray or Din Rail mounted B Rugged metal case Industrial grade PES42P Series have a robust design and are packaged in a rugged sheet metal enclosure to ensure high reliability and durability even when placed in industrial or outdoor applications _www GarettCom con s NN 23 PES42P PoE Edge Switches Installation and User Guide 07 07 B Qualified to use for temperature un controlled outdoor application The Magnum PES42P Premium rated versions of Edge Switches have an ambient temperature rating between 409C to 752C for DC models and qualify for temperature un controlled outdoor applications B Efficient Compact design for all purpose convenient mounting Featuring a compact steel case with an external AC and internal DC power supply Magnum PES42P Series o
18. ave an 8 15 VDC output with 6ft long cord and a 2 5mm center ve jack The external AC power supplies are temperature rated to match the Edge Switch ratings www GamettCom con 1 4 PES42P PoE Edge Switches Installation and User Guide 07 07 Option for 12VDC jack for wall mount only be used to power the PES42P unit when no PoE devices are attached act as non PoE switch Temperature un controlled Premium P Ratings 40 to 75 C North America Pd models Outdoor temperature rated Input 6ft AC power cord to IEC 320 connector on the100 240vac 47 63Hz external power adapter Output 12vdc 2Amps International Pi models Outdoor temperature rated Input IEC 320 connector on the 100 240vac 47 63Hz external power adapter Requires a user supplied pou cord Output 12vdc 2Amps a Power Consumption See Section 3 6 Note 1 the 12V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block Power supply protection is provided by internal diodes Note 2 The Direct DC power floats The user may ground either or if desired PES42P PoE Edge Switches Installation and User Guide 07 07 Direct DC POWER SUPPLY built in terminal block for ground 48V DC internal range 46 to 60V DC ground Total power input required for PoE ports 66 Watts max OR 1 4A 48VDC Power Consumption Typical 3 5 watts 4 watts maxm All six copper ports Power Consumption Typical 7
19. be easily installed in almost any location A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet or for securing the unit on a table top or shelf Alternatively metal mounting clips and screws are included for a rugged and secure mounting in any orientation Installation of the Magnum PES42P Series PoE Edge Switch is a simple procedure The installation location is dependent upon the physical layout of the Ethernet network and associated cabling Make sure the unit is installed in a location that is easily accessible to an AC power outlet or the appropriate DC source and where cooling is not inhibited The green Power PWR LED must turn ON when power is applied 3l PES42P PoE Edge Switches Installation and User Guide 07 07 3 2 MC14 TRAY for Rack Mounting of PESA2P Series PoE Switches For 19 rack mounting of Magnum PES42P series Edge Switches a rack mount tray is available the MC14 TRAY The Edge Switches are mounted with the DC power jack in the back with the fiber and the RJ 45 connectors in the front Any mix of the Edge Switches and or Media Edges may be placed on a tray up to a maximum of 8 units The mounting spaces of the MC14 TRAY are specific to the Magnum products and will not permit other models to be properly mounted www GarrettCom com COSS 22 PES42P PoE Edge Switches Installation and User Guide 07 07 In a typical installation the MC14 TRAY 19 rack mount
20. cation are VOIP for voice Wireless access points for wi fi connection and a PoE Clock to synchronize the time with the SNTP server for correct timing This application for Industrial power utility locations is becoming more popular for securing premises and is accepted as a cost effective solution for multi location communication www GamettCom com 28 PES42P PoE Edge Switches Installation and User Guide 07 07 H NC PLC E PLC SCADA orkstatio IBM T PPES42P Power Source Switches used as a reliable cost effective solution fr providing Data Power and Voice over RJ 45 Ports for Industrial application orkstatio Data to PoE devices e g PoE Clock VOIP phone and wireless access point PES42P PoE Edge Switches Installation and User Guide 07 07 3 0 INSTALLATION This section describes the installation of the Magnum PES42P Series PoE Edge Switches including location mountings power supply options and media connections 3 1 Locating the Edge Switch Unit All the PES42P Series Switches operate in transparent half and full duplex mode The store and forward switches easily take care of network traffic and can be used as a useful Secure attachment of economical tool to expand an existing clips for panel network www GamettCom com 30 PES42P PoE Edge Switches Installation and User Guide 07 07 The compact and lightweight design of the Magnum PES42P Series allows it to
21. d and developed with premium grade extended temperature components Industrial rated PES42P PoE Edge switches are suitable for use in sheltered outdoor locations and temperature uncontrolled environments with a temperature rating of 40 C to 75 C The Magnum PES42P PoE Power source Edge Switch combines standard 802 3af Power over Ethernet PoE with a small heavy duty 4 port PoE ports and 2 100Mb Fiber or 10 100 RJ 45 ports as per the user requirement Using an external 48vdc power source all four of the PES42P s Ethernet ports www GamettCom com 12 PES42P PoE Edge Switches Installation and User Guide 07 07 can provide Power as well as 10 100 Mb data transmission over the inter connecting Ethernet cables So a single Ethernet twisted pair RJ 45 cable will be able to transmit voice data and power from the attached devices The PES42P Edge switches are Power Sourcing Equipment PSE and are fully compatible with Powered Devices PD e g wireless access points IP phones that comply with the IEEE 802 3af PoE standard NOTE Only PoE powered devices complying with IEEE barrettCom 802 3af are recommended to work successfully with d Magnum PES42P PES42P power source PoE switches NON 802 3af Premium i LE compliant PD devices might have COMPATIBILITY issues and are not being supported with PES42P PoE switches PES42P PoE Edge Switches Installation and User Guide 07 07 The PES42P sw
22. daptor is used DC is supplied via the jack www GamettCom com 37 PES42P PoE Edge Switches Installation and User Guide 07 07 Power input from the DC terminal block and the jack may be connected simultaneously for power input redundancy 29 66 99 DC Power Terminals gnd GND Terminal for earth or ground wire connection to the PES42PH chassis Input Voltage 48VDC Alarm Contact Terminal 48VDC 46 57VDC 12V 8 ISVDC Input current PES42P PoE Edge Switches Installation and User Guide 07 07 3 7 PESA2P Series DC powered 48VDC Installation This section describes the proper connection of the 48VDC leads to the DC power terminal block on the Magnum PES42P PoE Edge Switch as shown in the Figure The DC terminal block on the Magnum PES42P is located on the left side of the unit and is equipped with three 3 screw down lead posts The power terminals are identified as positive and negative and they are floating inside the unit so that either of the terminals may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert www GamettCom com 00 39 PES42P PoE Edge Switches Installation and User Guide 07 07 the DC leads to the PES42P s power terminals positive and negative screws The use of Ground GND optional it connects to the PES42P chassis Ensure that each
23. duplex auto sensing for mode and speed and auto cross for plug polarity See Section 4 2 When the connected device is 10 Mbps the PES42Ps obey all the rules of 10 Mbps Ethernet configurations The 10 Mbps users can communicate with 100Mbps users as well as other 10 Mbps users through the switch Similarly the 100Mbps traffic obeys the rules of 100Mbps Ethernet and can communicate with 10 Mb and 100Mb users Magnum PES42P Series units are plug and www GamettCom com 51 PES42P PoE Edge Switches Installation and User Guide 07 07 play devices There is no software configuring to be done at installation or for maintenance even for the LLL ports The internal functions of both are described below Switching Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses lie on the same port segment will be filtered constraining them to one port and relieving the rest of the network from processing them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Packets needed for maintaining the operation of the network such as occasional multi cast packets are forwarded to all ports The Magnum PES42P Series Edge Switches operate in the store and forward switching mode which eliminates bad
24. e Magnum PES42P Series Edge Switches are constantly adapting internally to provide maximum network performance with the least dropped packets When the Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer www GamettCom com jo 20 PES42P PoE Edge Switches Installation and User Guide 07 07 Another feature implemented in Magnum PES42P Series Edge Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic The latency the time the frame spends in the Switch before it is sent along or forwarded to its destination of the PES42P Series PoE Edge Switches varies with the port speed types The length of the frame is a variable as it is with all store and forward switches For 10 Mb to 10 Mb 10 Mb to 100Mb or 100Mb to 10 Mb forwarding the latency is 15 microseconds plus the packet time of 10 Mb
25. en crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 If the fiber port does not link up while connecting to other device do a quick Loop test to test the fiber transceiver is functional or not Use a short patch cable of fiber and connect one end of cable to transmit and other end of receive to the fiber port transceiver If the Link Led turns solid green then the fiber port is functional and working 4 Make sure that an AC power cord is properly attached to each Magnum PES42P Series unit Be certain that the AC power cord is plugged into a functioning and appropriate electrical outlet Use the PWR LEDs to verify each unit is receiving power www GamettCom com 00 TT 58 PES42P PoE Edge Switches Installation and User Guide 07 07 5 If the problem is isolated to a network device other than the Magnum PES42P Series 10 100 Mb s switch product it is recommended that the problem device is replaced with a known good device Verify whether or not the problem is corrected If not go to Step 6 below If the problem is corrected the Magnum PES42P Series Switch and its associated cables are functioning properly 6 If the problem continues after completing Step 5 above contact your supplier of the Magnum PES42P Series 10 100 Mb s Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance www
26. er Budget Calculations for PESA2P Series Fiber Media 45 3 8 6 Connections to NICs which support Auto Neg RJ 45 ports 47 3 8 7 Mounting Dimensions for PESA2P with metal brackets 48 AO OPERATION c 51 4 1 Dual Speed Functionality and Switching ccccccccceeeeeeeeeeeeeees 51 4 2 Auto cross MDIX Auto negotiation and Speed sensing 53 4 3 Dual LEDs Front panel and side panel Magnum PES42P Series 54 4 4 Hardware operated Alarm Contact for monitoring internal power supply55 530 TROUBCESHOOTING 455 5 Pressure o va d Eae rA o Cede oaa exo Coa Von ev os iUe 56 5 1 Before Calling for Assistance sic oee iacccasssiecadincorasdriucdenutanewoscanterdintenses 57 5 2 When Calling for Assistance sese 60 www GametiCom com Ss V PES42P PoE Edge Switches Installation and User Guide 07 07 5 3 Return Material Authorization RMA Procedure 61 5 4 Shipping and Packaging Information cccceccccececeassseeseeseeeeeeeees 62 APPENDIX A WARRANTY INFORMATION eeeeeeeeeeeeeeeeeeeue 64 Revisions Rev A 07 07 Initial release of this user manual for PES42P PoE Edge Switches GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice vi PES42P PoE Edge Switches Installation and User Guide 07 07 1 0 SPECIFICATIONS 1 1 Technical Specifications
27. es 10 Zd Inspecting the Package and the Product cssseeeseeeeeeeeeeeeeeeeeees 10 2 2 Product Description uiu coria cett eicit i Reti S nant nedsonnc ase heuiipaneiabaneesnedaeads 11 2 3 Frame Buffering and Latency seeeeeessssssseseeeeeeeeeeeeenns 18 2 4 Features and Benefits nennen eene enne 22 2 5 Applications for PES42P Series Edge Switches 25 30 INS TATA ON eva X vRe 1E ER HEP vE SEED HER ER asked o ds 30 3 Locating the Edge Switch Unit eeeeeeeeeeree 30 3 2 MC14 TRAY for Rack Mounting of PESA2P Series PoE Switches 32 3 3 MC14 TR PS9 MC14 TR PS9X2 for Rack Mounting Media Edges 33 3 4 DIN Rail mounting Option cc eeeececssseeseeeceeeeeeeceeeeaaeaeeseeseeeeeeeeess 35 3 5 Power Requirement for Magnum PES42P PoE Edge Switch 36 3 6 Powering the PES42P DC internal with 48VDC power input 37 1V PES42P PoE Edge Switches Installation and User Guide 07 07 3 7 PES42P Series DC powered 48VDC Installation 39 3 8 Connecting Ethernet Media for PES42P PoE Edge Switch 41 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 42 3 8 2 Connecting Fiber Optic ST type twist lock 43 3 8 3 Connecting Fiber Optic SC type Snap In 44 3 8 4 Connecting Single Mode Fiber Optic sess 44 3 8 5 Pow
28. f Edge Switches can be installed in small spaces in cabinets on table tops in racks walls or DIN Rail mounted and in trays such as the Magnum MC14 TRAY B MDIX ports to eliminate cross over cables while cascading All the Magnum PES42P Series Switches are featured with MDIX auto cross which easily allows cascading with other Switches Hubs or media Edges without using the cross over cable B DC Power input for PoE Power Source Switch PS14P The 802 3af PoE standard PS14P power source switch requires 1 4 Amp 48V DC to provide enough power for 13 15watts on each RJ 45 port The Terminal block for 48V DC input is a range of 46V to 60V DC www GamettCom com j 24 PES42P PoE Edge Switches Installation and User Guide 07 07 B Hardware operated Alarm terminal block for hardened model PES42P Series The Alarm contact option on PES42PH and PES42P enables monitoring for internal power failure and provides extra reliability to the hardened Switch B Link Loss Learn feature for faster recovery in redundant network The LLL feature qualifies the Edge switches to actively work along with Managed redundant network structure as a client switch and allow a faster recovery during ring break The redundant topology must have one managed switch with STP RSTP feature to control the ring 2 5 Applications for PES42P Series Edge Switches Example 1 Magnum PES42P Power Source Switch for PoE device only This example is an Industrial applicati
29. fiber optic with SC type connector 20km SSCL 100Base FX SSCL single mode fiber optic with SC type connector 40km ST 100Base FX ST multi mode fiber optic with ST type connector 2km SST 100Base FX ST single mode fiber optic with ST type connector 20km SLC 100Base FX SLC single mode fiber optic with LC type connector 15km MTRJ 100Base FX MTRJ multi mode fiber optic with MTRJ type connector 2km SLC 100Base FX SLC single mode fiber optic with LC type connector 15km SFC 100Base FX SFC single mode fiber optic with FC Screw type connector 20km SSCX 100Base FX SSCX single mode fiber optic with SC type connector 100km Accessories MC14 TRAY 19 Rack mount tray for 14 series Switch models up to 16 units Other Tray configurations with power supplies and power cabling included See Section 3 3 DIN RAIL MC2 Metal DIN Rail mounting bracket for one PES42P Series Switch See Section 3 4 Conformal Coating for high humidity and tropical applications request quote www GamettCom com TT 9 PES42P PoE Edge Switches Installation and User Guide 07 07 2 0 INTRODUCTION This section describes PES42P Series models including appearance features and typical applications 2 1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product notify the carrier immediately of any damage that you believe occurred du
30. itch ports follow an auto sensing algorithm so that they provide power only to 802 3af PoE end devices PoE is managed by a multi stage handshake to protect equipment from damage and to manage power budgets The PES42P ports will discontinue supplying power when the PoE powered devices are disconnected on incorrect impedence value PES42P s support the 802 3af PoE PSE standard for over current protection under current detection and fault protection The PES42P is an 802 3af standards compliant way to power and connect a few small Ethernet devices at the edge of a network where AC power is not cost effective to deploy Since PoE is rapidly emerging as an Ethernet option in industrial commercial outdoor and military applications the Magnum PES42P is enabling the efficient deployment of reliable security cameras VoIP and wireless access networking devices to increase the efficiency of heavy duty industrial communications Furthermore using PoE switches like the Magnum www GamettCom com j 14 PES42P PoE Edge Switches Installation and User Guide 07 07 PES42P can produce significant cost savings as well as flexibility and reliability over traditional AC powered devices The simplicity of PoE increases reliability and reduces the overall cost of installation and operation These are applications where the Magnum PES42P can be used to provide the power and data for these POE Powered Devices which require 12 13watts maximum Wire
31. ize only eight PES42P units can fit in one MC14 TRAY Metal mounting screws in the bottom front hold each of the PoE Edge Switches securing them in the tray and enabling separate removal for service The dual LEDs permit viewing of Edge Switch status from any angle www GamettCom com 34 PES42P PoE Edge Switches Installation and User Guide 07 07 3 4 DIN Rail mounting option The Magnum PES42P PoE Edge Switches designed for use in Factory Floor Industrial Ethernet environments are available for DIN Rail mounting in an enclosure having DIN Rails i a m f E e 5 48VDC into P514P i ML50 105 supplie and CS14H f 3 NN N A Magnum PES42P is shown alongside the DIN Rail MC2 bracket here gt The metal DIN Rail mounting hardware is optional and needs to be ordered as a separate item e g Model DIN RAIL MC2 It comes with four screws to attach the bracket to the MC unit The rail clip is spring loaded 35 PES42P PoE Edge Switches Installation and User Guide 07 07 with a pull up latch at the top for easy snap on attachment and removal The Magnum PES42P models with PR have 48VDC power and have the DIN Rail MC2 bracket included and assembled with the MC unit at the factory 3 5 Power Requirement for Magnum PES42P PoE Edge Switch POWER INPUT Total Power Consumption 66 watts max 1 5A 48VDC 4PoE 2 non PoE copper Total Power Consumption 66 wa
32. less LAN access points and WLAN Mobility system VOIP phones Remote Security Camera SNTP Clock Factory floor and building control monitoring Temperature Smoke Heat and other environmental sensors Fire alarms www GamettCom com 15 PES42P PoE Edge Switches Installation and User Guide 07 07 Security devices like retinal scanners or fingerprint readers Lighting control Home automation systems Because of the approval of 802 3af PoE standard the RJ 45 Ethernet jack will become the first worldwide standard power plug The futuristic applications of PoE looks promising as a convenient point providing Notebook computer Cell phone chargers and PDA games power through the PoE devices The sleek and compact PES42P featured with special thermal techniques for harsh temperatures and a hardened rugged enclosure qualifies to provide a multi purpose choice for all PoE device applications The PES42P is a very important source to meet all IEEE 802 3af compliant PoE requirements with multi choice options www GamettCom com j 16 PES42P PoE Edge Switches Installation and User Guide 07 07 The Magnum PES42P PoE Switch provides edge access Ethernet ports in a convenient and compact package For fiber connectivity of additional non PoE ports simply use port and 2 two RJ 45 or 100Mb fiber ports with LLL feature to meet the Fiber and copper 10 or 100Mb requirements Please see sec 1 2 or
33. m Magnum S14 MS onvenient Switch IBM rore l S PS14P Power Source Switches used as a reliable cost m expanding solution for the non stopping network demand by providing powerpata to PoE devices e g PoE video camera and wireless access point Example 2 Magnum PES42P Power Source Switch for PoE device only www GamettCom com 000 27 PES42P PoE Edge Switches Installation and User Guide 07 07 In another application for the modern power plant floor the requirement is to provide the complete floor with wireless access points to avoid cabling mess and connect all the status delivery joints with VOIP phones The New PES42P PoE 802 3af compatible power source switches fit very well to fulfill this requirement The PES42P s are cost effective economical and avoid additional electrical cable expansions and related expenses The sleek industrial proof Magnum PES42P PoE with its power Source Switch capability easily meets the demand to provide power through its RJ 45 cable and allows for a very neat Network setup The Magnum PES42P POE is enabling the efficient deployment of reliable VoIP and wireless access tools to increase the efficiency of communication across the enterprise Furthermore using PoE devices like the Magnum PS14P PoE has significant cost savings flexibility and reliability advantages over traditional AC power They reduce the overall cost of network ownership The PoE devices used for this industrial appli
34. me and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem www GamettCom com e 61 PES42P PoE Edge Switches Installation and User Guide 07 07 GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 5 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions www GamettCom com TT 62 PES42P PoE Edge Switches Installation and User Guide 07 07 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide
35. oOo GarrettGom Industrial Networking at Its Best Magnum PES42P PoE Edge Switches Installation and User Guide www GamettCom com 5 00 USD PES42P PoE Edge Switches Installation and User Guide 07 07 Magnum PES42 Series Edge Switch Installation and User Guide Part 84 00141 Rev A 07 07 Trademarks GarrettCom Magnum Link Loss Learn S Ring Convenient Switch Edge Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum PES42P Series 10 100 Mb s PoE Edge Switches contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum PES42P 10 100 Mb s Edge Switch products consult Section 5 Troubleshooting of this User Guide Copyright 2007 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America www GamettCom com Ug 1 PES42P PoE Edge Switches Installation and User Guide 07 07 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict acc
36. on where the expansion of their factory network is being done to extend their capacity and make it more secure via IP Videp surveillance cameras which monitor the day to day manufacturing process The blue tooth wireless access point was also implemented to eliminate the cable www GamettCom com 00 TT 25 PES42P PoE Edge Switches Installation and User Guide 07 07 wiring between the PS14P PoE switches The un controlled temperature and the electric wiring were the big challenges to meet at this requirement The Magnum PS14P PoE Power source switch is an effective and convenient solution for remote locations where providing power through wire is not only difficult but expensive too The cost effective and efficient Magnum PS14P with its robust enclosure provides a very economical solution through its 4 PoE RJ 45 ports The Power Source Switch with PoE ports are capable of carrying data power and voice over RJ 45 cable using Magnum PS14P PoE units All PoE enhanced cameras and access points would be directly connected to a power source PES42P switch to get the power in the unit via the copper port The security camera application is getting very popular in sensitive areas e g school airport Bus Train Terminal Industrial secure location port and various other important locations 26 PES42P PoE Edge Switches Installation and User Guide 07 07 L Ex IBM Compatible 48vdc il aS o ly GarrettCo
37. ordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference _ www GarrettCom com s ii PES42P PoE Edge Switches Installation and User Guide 07 07 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com Email support garrettcom com www GamettCom com iii PES42P PoE Edge Switches Installation and User Guide 07 07 TABLE OF CONTENTS Page LO SPECIEI XLIIONGS easiness ttecucoasesvanesencactrevasdattacscessusseassecasersateeresssttouess 1 1 1 Technical Specifications vsicscsecsennssndssctavexsresdvocsiecdtnaseesenadenentecciaedtaadenes l 1 2 Summary of models and descriptions from PES42P Series 8 20 INTRODUCTION sssscesseconcssessscosnasesensacaveissscesveasicaviaassensiccasiensscastsasac
38. price list for correct model no All PES42P Power Source Edge Switch models come with two 2 sets of LED indicators One set is mounted in the end adjacent to three of the RJ 4 ports for easy viewing when the unit is mounted in a rack mount tray 17 PES42P PoE Edge Switches Installation and User Guide 07 07 The Magnum PES42P Power Source Switch requires a heavy duty power supply of 48VDC 1 4Amps 66 watts total consumption to provide 13 15w power on each port to the PoE unit The heavy duty Din rail mounted 48V DC power supply can be purchased using this URL http www lanstore com ps htm Note The 8 15vdc option is also being offered to power the PES42P unit when no PoE devices are attached While using a 12vdc Adaptor to power on the switch the unit will not function as a PoE power source switch but as a non PoE regular switch only 2 3 Frame Buffering and Latency The Magnum PES42P Series PoE Edge Switches are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have 18 PES42P PoE Edge Switches Installation and User Guide 07 07 the correct CRC i e they are good packets This eliminates propagation of bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express
39. r Output Power and Pg Receiver Sensitivity Worst case OPB OPB IdB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um m m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km and the Cable Loss for 9 125 Single mode is 0 25 dB km SSCX The following data has been collected from component manufacturer s Agilent s JDS Uniphase stratus Lucents web sites and catalogs to provide guidance to network integrators and installers www GamettCom com ge jj 0 45 PES42P PoE Edge Switches Installation and User Guide 07 07 Fiber Std km Wavel Cable X mitr R cvr W Port fdx ength Size Module d hdx nm PES42P 100Mb Multi 1310 625 125 MST MSC FX mode o 4 50 125 23 5 100Mb Single 20 i3 FX mode 04 1310 9 125 PESADI HD Multi o 62 5 125 31 90 3 0 158 55 MTRJ mode oa 50 125 235 31 5 5 2 0 122 4 0 5 p Dd U2 N UA B CA 100Mb Single 40 9 125 04 p gw ingle 100Mb Single COEM E N N oo J PES42P PoE Edge Switches Installation and User Guide 07 07 Note The use of either multi mode or single mode fiber to operate at I00Mbps speed over long distances i e over approx 400 meters can be achieved only if the following
40. ring shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain l Magnum PES42P Series PoE Edge Switch unit l External Power Supply for Pd and Pi models only 1 set Metal panel mounting clips and screws 2 each 1 User Guide this manual www GamettCom com TT 10 PES42P PoE Edge Switches Installation and User Guide 07 07 Remove the Magnum PES42P Series Edge Switch from the shipping container Be sure to keep the shipping container should you need to ship the unit at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container Refer to Section 5 Troubleshooting for specific return procedures 2 2 Product Description Magnum PES42P 4 port PoE and 2 port LLL Power Source Switch PES42P Industrial PoE switch is a reliable and premium rated Industrial Ethernet GarrettCom product Switch and an addition to the PoE switch E family of PES42P and 6K PoE modules Strictly mum designed to be IEEE 802 3af compatible the 4 ports PoE Edge switch not only provides PoE 1 PES42P PoE Edge Switches Installation and User Guide 07 07 options on port 3 4 5 and 6 but is also equipped with a LLL Link Loss Learn feature on port 1 and 2 for use in self healing redundant LAN structures Enclosed in a rugged enclosure designe
41. tts max 1 6A 48 VDC 4PoE copper 2 non PoE fiber Terminal block for 48v DC input range of 46 to 60V dc built in for ground Note The 8 15V DC option is also present but can only be used to power the PES42P POE unit when no PoE devices are attached The device will not function as PoE Switch while powered up via 12VDC power but as a normal non PoE Switch POWER OUTPUT PoE available on all four RJ 45 ports via Ethernet twisted pair cabling on port pins using the data pair 1 2 3 6 4 802 3af Power Consumption 66 watts max 15 4 max port PoE Ports Output voltage 46 to 57 VDC Over Current Protection per port reset able fuse Power Consumption Typical 3 5 watts 4 watts maxm All six copper ports www GamettCom com 00 36 PES42P PoE Edge Switches Installation and User Guide 07 07 Power Consumption Typical 7 watts 8 5 watts maxm 4 PoE 2 non PoE fiber port Worst case Power input 70 Watts Note Din Rail mounted Powerful 48vdc supply used for Magnum PES42P POE can be bought directly using this URL http www lanstore com ps htm 3 6 Powering the PES42P DC internal with 48VDC power input Each Magnum PES42P Series is equipped with an internal DC power supply and has built in screw terminals for secure attachment of the power input leads Three DC power models support a range of power input types The three DC power input terminal block choices are for use with 48VDC power Where an AC power a
42. ty Swap the fiber cables at the fiber connector to remedy this situation 3 8 5 Connecting Fiber Optic SC type Snap In The following procedure applies to installations using SC type fiber connectors i e using multi mode SC and SC single mode While connecting fiber media to SC connectors simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures 3 8 4 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances about 20Km with the multi mode SC The same procedures as for multi mode fiber apply to single mode fiber connectors Follow the steps listed in Section 3 8 2 above www GamettCom com 44 PES42P PoE Edge Switches Installation and User Guide 07 07 3 8 5 Power Budget Calculations for PES42P Series Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pg min where Pr Transmitte
43. watts 8 5 watts maxm 4 PoE 2 non PoE fiber port Port Connectors RJ 45 Ports support IOOBASE TX and IOBASE T with auto cross MDIX They are shielded 8 pin female connectors for shielded STP and unshielded UTP Cat 3 4 5 cable One Fiber optic port On the ES42 Series it is IO0Base FX with a fiber flavor choice of multimode SC ST LC or MTRJ or single mode SSC SSCL SST or SLC connectors By default factory settings is at Full duplex on fiber ports PES42P PoE Edge Switches Installation and User Guide 07 07 LED Indicators Front POWER Steady ON when power applied 10 100 Steady ON for 100Mbps OFF for 10 Mbps copper ports only LK ACT Steady ON for LINK LK with no traffic BLINKING indicates port is transmitting receiving ACT F H Steady ON for full duplex OFF for half duplex Fiber port only Mounting options Metal mounting clips for panel mounting included DIN Rail mounting option Model DIN RAIL MC2 see Section 3 4 Rack mount option MCIA TRAY see http www garrettcom com mc tray htm Depth 6 0 width 17 Height 2 25 15cm D x 43cm W x 5 7cm H Mean Time Between Failure MTBF over15 years Telcordia Bellcore Method Agency Approvals and Standards Compliance UL Listed UL 60950 cUL CE Emissions meets FCC Part 15 Class A www GamettCom com 00 7 PES42P PoE Edge Switches Installation and User Guide 07 07 NEBS L3 and ETSI compliant IEEE P1613 Env Std for Electric Po
44. wer Substations NEMA TS 2 and TEES for traffic control equipment designed for UL 2043 above the ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty Three years return to factory Made in USA 1 2 Summary of models and descriptions from PES42P Series PES42P 2ff 48 VDC Magnum 6 port Premium rated PoE 802 3af Power sourcing Edge switch four RJ 45 PoE two 100Mb Fiber port non PoE Alarm contact for power monitoring 48VDC terminal block for power input Metal panel mounting brackets included The 2ff field is for selection of the desired fiber flavor as listed below The 1ff one fiber five RJ 45 ports and no ff six RJ 45 ports only models are also same as below except the port options PES42P Models four RJ 45 10 100 with two100Mb fiber flavor option PES42P 2ff 48VDC Premium P two 10 100 RJ 45 two 100Mb non PoE Fiber ports for un controlled outdoor 40 to 75C using direct DC 8 15VDC and or external AC premium power supply included www GamettCom com 00 8 PES42P PoE Edge Switches Installation and User Guide 07 07 PES42P 1ff 48VDC Same as PESA2P 2FF Pd Pi except 1 100 Mb non PoE fiber port PES42P 48VDC Same as PES42P 2FF Pd Pi except with no fiber port options PES42P 2ff 48VDC Same as PES42P 24VDC model except 48VDC input replaces 24VDC SC 100Base FX SC multi mode fiber optic with SC type connector 2km SSC 100Base FX SSC single mode