MASTER USER GUIDE
Contents
1. INTRUDER ALARM MANUFACTURER THANK YOU FOR VOTING TEXECOM MASTER USER GUIDE I Veritas RGPiu Security Control Panels cE Texecom www texe com Assigning Access Codes Master User Guide Master User Guide Assigning Access Codes The control panel allows up to eight users to operate the alarm system each user is assigned an Access code Access Level and User Number The figure below shows an example of users assigned to a typical alarm system Ni User Number 1 User Number 2 User Number 3 User Number 8 Access Code 4321 Access Code Access Code 5678 Access Code 2580 Access Level Master User Access Level Boss Engineer Access Level User Access Level Cleaner Access Type Customer Access Type Installer Access Type Customer Access Type Customer User Number Each user is identified by the alarm system as User 1 through to User 8 Access Code Each user has a programmable 4 digit Personal Access code which the user enters in order to operate the alarm system Access Level Each user has a programmable Access Level that determines how the alarm system responds and which of the system facilities the user can access Each Access Level has an associated number 1 8 which is used when programming the Access Level of a user 2 INS140 2 Master User Guide Assigning Access Codes There are eight possible User Access Levels User A User may set unset silence an al
2. When a cleaner is Setting the system the Cleaner Suite zones NOTE will flash indicating that they are currently omitted but are about to be re included Any other omitted zones e g if the system was previously part set rather than full set will also flash but will NOT be included 2 If the system is unset then a cleaner can full set part set and omit zones Null The Null level is the only level which can be changed both by a Master User and by a Boss Engineer The Null level has two functions 1 If a user is no longer required its Access Level should be changed to Null This will erase the associated Access code 2 To change a Customer Access Type to an Installer Access Type or vice versa it must first be changed to the Null level Boss Engineer Boss Engineers cannot change Customer Access Levels or Customer Access codes They can only change Installer Access Levels and Installer Access codes Boss Engineers can also access all system programming options Access Type There are two Access Types Customer and Installer The Boss Engineer level can only program the Installer Types The Master User Level can only program the Customer Types The table below shows a summary of each Access Level and who is responsible for assigning the level Access Level Access Can be Programmed Number Type User Customer Master Engineer Installer Boss PA Panic Customer Master Duress Customer Master Master User Customer Master Clean
3. Your User Number Each user is identified by the alarm system as User 1 through to User 8 Every user may view their User Number 1 8 as follows INS140 2 5 Programming Access Codes Master User Guide From the Unset State 1 Enter your Access code AAA 2 Press PROG to access the Programming Menu 3 Enter 69 to select the View Your User Number option OO 4 The zone light corresponding to your User Number will illuminate 5 Press RESET the system will return to the Programming Menu 6 Press RESET to revert to the unset state Changing Access Levels D0 M Each Access Level has an associated Number 1 8 as follows Access Level Access Can be Programmed Number Type by User Customer Master Engineer Installer Boss PA Panic Customer Master Access Level Duress Customer Master Master User Customer Master Cleaner Customer Master Customer Master Null Installer Boss Boss Engineer Installer Boss me The Master User can only assign Customer Access Types and the NOTE Boss Engineer can only assign Installer Access Type From the Unset State 1 Enter your Access code Master User or Boss Engineer only Q Q 2 Press PROG to access the Programming Menu 3 Enter 7 to select the Change Access Level option D 4 Enter the User Number 1 8 you wish to change e g 5 6 5 Enter their new Access Level 1 8 e g 4 Duress D 6 Press PROG the system will chime to c
4. arm and reset the system In addition a User can test the system outputs perform a walk test and view the event log A User cannot change Access codes other than their own or Access Levels Engineer 2 Engineers cannot change Access Levels or Access codes other than their own However they can access all system programming options Personal Attack Entering a PA code will cause an immediate alarm sounding both the internal and external sounders Duress A Duress code behaves exactly as a User code Level 1 but will in addition activate the Duress channel on the communicator interface to secretly summon assistance Master User A Master User may set unset silence an alarm and reset the system In addition a Master can test the system outputs perform a walk test and view the event log A Master User can also assign new user Access code and Access Levels Cleaner If the system is full set or part set then a Cleaner code will automatically omit the Cleaner Suite zones without affecting the other zones In addition pressing a key will NOT cause the system to start entry mode On leaving the cleaner should enter their Access code Q and press either or CPART The key is disabled and the previous set will be restored irrespective of which key was pressed A cleaner cannot access Chime Nor can they cancel an alarm or reset the system INS140 2 3 Assigning Access Codes Master User Guide A 1
5. er Customer Master Customer Master Null Installer Boss Boss Engineer Installer Boss Access Level 4 INS140 2 Master User Guide Programming Access Codes Programming Access Codes Each user has a programmable 4 digit Access code which the user enters in order to operate the alarm system Changing Your Own Access Code Every user has the ability to change their own 4 digit Access code as follows From the Unset State 1 Enter your existing Access code DODOA 2 Press PROG to access the Programming Menu 3 Enter 60 to select the Change Your Access code option 4 Enter your new 4 digit Access Code MOO 5 Press PROG the system will chime to confirm your new code 6 Press RESET to revert to the unset state Assigning a New Access Code The Master User can assign a new Access code or change an existing Access code providing it is a Customer Type The Boss Engineer can assign a new Access code or change an existing Access code providing itis a Installer Type From the Unset State 1 Enter your Access code Master User or Boss Engineer only MOA 2 Press PROG to access the Programming Menu 3 Enter 6 to select the Change Access code option 4 Enter the User Number 1 8 you wish to change e g 5 6 5 Enter their new 4 digit Access code MOM 6 Press PROG the system will chime to confirm the new code 7 Press RESET to revert to the unset state Displaying
6. onfirm the new Access Level 7 Press RESET to revert to the unset state 6 INS140 2 Master User Guide Programming Access Codes Displaying Your Access Level D Every user may view their own Access Level From the Unset State 1 Enter your Access code AAO 2 Press PROG to access the Programming Menu 3 Enter 79 to select the View Your Access Level option DO 4 The zone light corresponding to your Access Level will illuminate 5 Press RESET the system will return to the Programming Menu 6 Press RESET to revert to the unset state For security reasons the Duress Access Level will be displayed as Nore the User Access Level Notes INS140 2 7 Code Table Master User Guide Code Table Defautt OPtionto New Defaut OPtionto New User User Change Change Access Access Access Access No Name Access Access Code Code Level Level Code Level 1 Master 2 Boss 3 Null 4 Null 5 Null 6 Null 7 Null 8 Null 1 Customer codes can only be programmed when the NOTE Programming Menu is accessed using a Master User code 2 Installer codes can only be programmed when the Programming Menu is accessed using a Boss Engineer code Access Level Access Level Can be Programmed by Number User Master Engineer Boss PA Master Duress Master Master User Master Cleaner Master Master Boss Boss Engineer Boss Null INS140 2