Home
Installation Instructions & User Guide
Contents
1. Cleaning the Rub clean Handset To remove the build up of limescale from your handset remove the handset from the handset holder and rub your fingers over the rubber spray jets these can be seen in Fig 9 When the shower is turned on the built up limescale will flush out of the sprayplate Troubleshooting Warning Before carrying out general repairs or testing the shower ensure that the electricity supply is turned off at the mains and the correct circuit is removed Symptom Likely Cause Action Remedy Standby light not on Fuse blown Examine electrical supply to shower Power supply interrupted No water flow Isolating valve Turn on Power supply not on Low pressure light on Water pressure has fallen below the Check running pressure minimum requirement Wait until pressure increases to 1 0 bar Water temperature too hot Insufficient water flowing through the Clean the handset shower Increase the flow by adjusting the temperature control knob Reduce the power setting Shower runs hot and cold Water pressure is at minimum Check running pressure during use requirement Wait until pressure increases Reduce temperature light Insufficient water flowing through the Reduce the temperature setting comes on shower increase flow rate Reduce power setting Water from pressure relief Pressure relief device operated Clean handset outlet Is shower hose connected or twisted Replace if n
2. the hotter the shower will be The faster the water flow the cooler the shower e The cold mains water temperature entering your property will be much cooler in the Winter than in the Summer months This will have an effect on the shower Setting at different times of the year e It will be necessary to adjust the temperature or power control settings throughout the year to accommodate this change e This shower contains a stabilising valve that will minimise temperature changes at the shower head due to pressure variations in the incoming cold water supply If any fluctuation in temperature is experienced the most likely cause will be that other appliances are being used within the house at the same time as the shower If the incoming water pressure to the shower drops below the minimum requirement of 1 bar running pressure the shower will automatically turn off the power to the heating elements User Instructions The Riser Rail The handset holder can be positioned on the riser rail to your required height by gripping the slider next to the rail and sliding it upwards or downwards until the desired position is achieved Operating the Handset Your NewTeam Electric Shower is supplied with a Zag Variable Spray handset this handset has 3 spray modes Spray J et spray and Combination To select your desired spray mode turn the handset levers and twist in either direction see Fig 9
3. 0V Rating at 230V NewTeam 7 8 7 8kW 7 2kW NewTeam 8 5 8 5kW 7 8kW NewTeam 9 5 9 5kW 8 7kW NewTeam 10 4 10 4kW 9 5kW The Electrical Installation and Circuit Protection of this shower must comply with E E Wiring Regulations and should be checked by a qualified electrician prior to use Please note It is important to switch off the fuse box before connecting the cable Please check for any hidden pipes and cables A separate and permanently connected cable must be taken from the consumer unit directly to the shower via a double pole switch with a minimum contact separation gap of 3mm It is recommended that a residual current device RCD formerly known as an earth leakage circuit breaker ELCB with a tripping current of 30mA is incorporated in the circuit The isolating switch can be a ceiling mounted pullcord switch within the bathroom or wall mounted in an adjacent room The switch must be easily accessible and identifiable as the supply to the shower In domestic installations you must ensure that the electrical supply and existing fuse board are adequately rated Important Voltage drop in the supply to the premises due to heavy local demand will affect the performance To ensure optimum performance and trouble free service from your shower care should be taken during installation This shower incorporates a pressure relief device in the unlikely event of the device discharging it is advisable to position the s
4. E E Regulations The supply cable can be surface mounted and clipped recessed or in conduit as detailed within the I E E Regulations Procedure Fig 4 e Ensure the electricity supply is switched off e Run the electrical supply cable from the consumer unit via an appropriate isolating switch and into the mains terminal block 1 in the shower unit e Connect to terminals as follows Live Terminal L Neutral Terminal N Earth Terminal e The earth cable where stripped must be sleeved prior to connection to the terminal block All terminals must be carefully tightened to avoid trapping the cable insulation with the retaining screws e Secure the supply cable using the clamp which is reversible for use with 6mm or 10mm cables If a cable size greater than 10mm is used the clamp should be discarded Warning Do not turn on the electricity supply until the cover assembly has been replaced e Before fitting the cover 2 ensure power spindle 6 and temperature spindle are in the correct position for example power spindle has narrow side at the 12 O Clock position see Fig 5 and the temperature spindle has locking clicker 5 at the 6 O Clock position If the clicker has been removed then it must be refitted as follows e Rotate the spindle fully clockwise to the stop position e Fit the clicker with the aim to the left of the stop 11 O Clock position NewTeam Electric e Offer th
5. Part No 404 0119 Issue 01 02 NewTeam Limited Brunel Road Earlstrees Industrial Est Please keep this booklet for future reference Corby Northants NN17 4 W Dear Installer When you have read these instructions please ensure you leave them with the user Product Features Product Features 1 Reduce Temperature Indicator Indicator light to show when the temperature a selection is too high 1 2 Low Pressure Indicator Indicator light to show low incoming water pressure 2 3 Standby Indicator Status light for standby informs the unit is ready for operation 4 Power Control Adjustable power settings Cold Medium and High 5 Temperature Control Adjustable Temperature Control Contents Installation amp Operating Instructions for NewTeam Electric Showers Please read this booklet carefully and ensure the installation is undertaken by a competent person Please note Following the headings in sequence will guide you through the installation and operation of your NewTeam Electric Shower Planning Your Installation 2 Fitting Your Shower 3 5 e Plumbing Connections e Electric Connections The Unit e Riser Rail Hose and Handset User Instructions 7 10 Trouble Shooting 10 Spare Parts Listing 11 12 Guarantee 13 Refer to back cover for Guarantee Customer Service and Replacement Parts Policy In the event of any query regarding installation p
6. SP 092 1025 Camshaft Retention Plate X X X X 12 SP 092 0420 Phased Shutdown PCB X X X xX 13 SP 092 1133 2 Stage Thermal Cut out X X X X 14 SP 092 1077 Microswitch 25 amp X X X X 15 SP 092 1027 Camshaft X X X X 16 SP 092 1085 Microswitch Operating Lever Assembly X X X X 17 SP 092 1060 Pressure Relief Device Assembly X X X X 18 SP NT Cover ModelCode NewTeam Cover amp Knob Assembly i aa a p20 19 SP 092 0429 Screw Brush XIXIXIX 20 SP 092 0018 Cover Retaining Screw XIXIXIX SP 5019 WT 7 8 Base Assembly Complete X SP 5020 WT 8 5 Base Assembly Complete X SP 5021 WT 9 5 Base Assembly Complete X SP 5022 WT 10 4 Base Assembly Complete X SP 285 0023 WT 1 25 x 8mm Shower Hose XIXIXIX SP 168 0205 WT Handset XIXIXI X SP 320 0026 Hose Washer XIXI IXIJIX Please state model of shower Guarantee amp Service Policy Your Guarantee Thank you for purchasing a NewTeam shower designed manufactured and tested to the highest standards by NewTeam Ltd to give you a long and reliable service This product has a 2 year guarantee 1st year parts and labour 2nd year parts only This is provided that The guarantee registration card is completed and returned along with a copy of proof of purchase within ten 10 days e The product is installed and operated in accordance with our instructions and has not been misused or damaged This in no way affects your statutory rights as a consumer The information on
7. ainer Mark the wall to indicate the upper fixing screw position Screw centres are 605mm approximately 23 inches apart e Drill the wall at the marked fixing position using a 6mm drill and loosely fix the rail end checking that the rail is hanging vertically using the spirit level incorporated into the top end of the rail The bubble should be exactly between the two lines on the spirit level body Mark the position for the lower fixing screw move the rail to one side drill the wall and fix the lower end of the rail e Check that the rail is vertical and tighten both fixing screws e Slide the end cap into position on the top end of the rail and fit the screw cover into the recess in the hose retainer When fitting the hose the hose should pass through the hole in the hose retainer Note The hose nut not the handset handle fits into the slider The slider moves more freely on the rail if gripped next to the rail rather than at the handset User Instructions e If the correct showering temperature cannot be obtained it may be necessary to adjust the Power Selector 2 or Temperature Control 3 to an alternative setting If the Reduce Temperature light 4 becomes illuminated it is indicating that the temperature setting is too high to allow sufficient water flow over the heating elements Lowering the temperature setting slightly will allow the shower to function correctly The unit may take a few sec
8. and a description of the complaint Our service staff are fully qualified to advise on correct installation procedures and will be able to diagnose whether the fault will require a replacement part or a visit from a NewTeam engineer If required a service call will be booked and either yourself or an appointed representative who should be a person of 18 years or over must be present during the visit All site visits to product within the guarantee period will be carried out free of any parts or labour charges provided the conditions of the guarantee have been adhered to second year guarantee is parts only All site visits to product out of guarantee will be subject to charges for parts and labour which is payable by you or your appointed representative at the time of the visit Charges will also be levied on cancelled appointments unless advised to NewTeam at least 24 hours in advance of the agreed date and time We reserve the right not to undertake work where payment cannot be made to our engineer at the time of the visit NewTeam hold stocks of components for all their range of products and these will be maintained for the duration of their life Should a product be discontinued spare parts stocks will be maintained but in the event of a part becoming unavailable NewTeam reserve the right to supply a substitute of equal quality The following payment methods can be used to obtain spare parts By post pre payment of proforma in
9. asing your NewTeam shower NewTeam Product Knowledge OQ Product Features OQ Product Styling OQ Price Q Other Q Please specify Please tick here if you do not require any further information or product updates from NewTeam Q Post Back Fold and tape as instructed overleaf Please tape down umop ade se jd 3rd Fold Affix stamp here NewTeam Limited Brunel Road Earlstrees Industrial Est Corby Northants NN17 4 W PIO4 ST PERPE ERA EN EEN E AEAEE E kode e sees EAEE EEN AEE E tote ee cet eed see EEEE E EE EIE E E teen EEE POL EEA ESE EE E E seeds cess esbised le eevsb eed EEE bsccceseees2 EET AA 2nd Fold
10. e cover 2 onto the shower unit ensuring that the power selector knob indicator is pointing to the N 10 setting e When the power selector and the temperature knobs are correctly engaged push on the cover 2 and fix with the three screws 3 provided e Turn on the electricity supply The standby light 4 should now be illuminated Please refer to User Instructions section to familiarise yourself with the controls before using the shower taeu aoM eine qe goed mh ie 12 o clock Narrow 6 o clock Wide Fig 5 Fitting the Riser Rail Spirit Rail Kit Before proceeding with fitting the rail identify each of the items supplied using the illustration Fig 6 The slider must not be removed from the rail during fitting The top of the slider has a smooth profile whereas the underside has a recess revealing the grooves on the handset holder No Part Description 1 Rail end cap Sprit level 3 4 Rail with slider attached Hose retainer Gel hook 6 Screw cap Hose retainer fixing screw Rail fixing screws and wall plugs e Fit the hose retainer onto the bottom end of the rail and secure using the small screw from the kit e Position the rail on the wall bearing in mind the heights of people likely to use the shower and the length of the hose when connected to the shower and passed through the hole in the hose ret
11. ecessary Do not attempt to repair the Pressure Relief Valve Device once activated it must be replaced Preparation for First Use Preparation for First Use e Ensure that the Power Selector knob is turned fully anti clockwise to read Power Setting e Rotate the Temperature Control knob fully clockwise e Turn on the water supply and inspect for water tightness e Turn on the electricity supply and the Standby neon will illuminate e Rotate the Power Selector clockwise to the Cold position Water will flow from the handset at minimum flow Allow the water to run freely for 60 seconds e Turn the temperature knob to mid position e Rotate the Power Selector clockwise to the Medium position The water temperature will gradually increase e Rotate the Power Selector clockwise to the High position and the water temperature will increase further To select your ideal shower temperature rotate the Temperature Control clockwise to increase and anti clockwise to decrease Note When the temperature setting is adjusted the flow rate of the water will change after a short time the temperature will stabilise e To turn the shower off rotate the Power Control knob anti clockwise to the Off position The shower will run on for a few seconds to flush out excess hot water from the unit and help prevent limescale build up e The se
12. hower unit over the bath or shower tray Fitting your Shower If the shower is to be installed in a hard water area we recommend that an in line scale reducer is fitted Please refer to your supplier for advice Options e The pipework can enter the shower from the left or right of the shower unit e If using the inlet connection to the left the pipework can enter from the top bottom or rear e If using the inlet connection to the right the pipework can only enter from the bottom or rear Changing the inlet connection from the left to the right Fig 2 e Lift out the outlet connection 1 from the shower unit case and bend upwards e Remove the two fixing screws and the clamp 2 e Swivel the inlet elbow 3 solenoid assembly over to the right e Locate the assembly into the cradle and re fix the clamp and the two fixing screws e Re position the outlet flexible into the shower unit case e Remove the appropriate cable pipework access panel or insert from the unit base Fitting the shower to the wall Fig 3 Warning Before drilling please check for any hidden pipes and cables e Select the position for the shower and offer the shower unit up to the wall marking the 3 fixing points Drill insert the wall plugs and secure the shower unit to the wall Plumbing connections e The outlet of this shower acts as a vent and must not be connected to any tap or fitting not recommended by NewTeam Limited Do
13. lease contact NewTeam Customer Service Department Tel 01536 264 012 Fax 01536 409 201 In line with our policy of continual product development the specifications may be varied and product design altered We reserve the right to depart from the details given in this manual without prior notice Planning your Installation Plumbing Fig 1 The installation must comply with all Water Authority and Building Bye laws and regulations To ensure the correct operation of this shower it must be installed to a mains cold water supply with a minimum running pressure of 1 0 bar 14 5 PSI using 15mm pipework see Fig 1 This shower can be supplied from a cold water storage tank providing there is a minimum static head of 10 metres from the base of the storage tank to the handset position If this option is taken it must only be on a totally dedicated supply to the shower The shower must not be installed in an area subject to freezing conditions Do not use if you suspect the shower is frozen this will damage the shower unit An additional service valve must be installed in the water supply to the shower as an independent means of isolation for future servicing requirements Do not exceed the maximum inlet pressure Maximum pressure 10 Bar 10 metre Minimum pressure running 1 Bar 1 metre Rated pressure 0 Bar Electrics Warning This appliance must be earthed Rating at 24
14. not use any jointing compounds during the installation Do not solder within 300mm of the shower unit or allow solder or flux to fall onto the casings e All plumbing connections should be completed before any electrical work is undertaken Procedure e Turn off the mains cold water supply and connect and run pipework to the shower An additional service valve must be installed for future servicing requirements e Flush out the pipework prior to fitting the shower e If pipework entry is from the rear ensure that there is space left around the push fit eloow for future servicing Bring the cold water pipe to the shower position and connect to the inlet elbow Fitting your Shower e The inlet pipe connection into the elbow is a self seal push fit type All burrs and rough edges must be removed from the end of the tube e Ifa chrome plated tube is used remove the first 25mm of plating e To release the pipework from the push fit fitting press and hold the grey collett against the elbow and pull the pipe out of the fitting e Turn on the supply and inspect for water tightness Electrical connections Warning This appliance and all connecting pipework must be earthed e Ensure that an earth continuity conductor is securely and permanently connected to all exposed metal parts of other services and appliances within the room where the shower is installed All cables must conform to the relevant tables within the I
15. onds to reset Note The speed of reset may be affect by the incoming water temperature and will be particularly noticeable during long spells of hot weather e If the Low Temperature light 5 is illuminated it is indicating that the incoming water pressure has fallen below the minimum requirement specified for the correct operation of the shower The shower heating element will turn off automatically to prevent discomfort for the user e When you have finished showering rotate the Power Selector 2 anti clockwise to the Off position Important Phased Shutdown After showering water will continue to flow for a few seconds to allow excess heat stored within the electrical elements to be discharged This will reduce the formation of limescale and prolong the life of your shower The shower should be turned off at the isolating switch when not in use Note The shower incorporates a pressure relief device in the unlikely event that the valve discharges water through the Pressure Relief Outlet Grill 6 please contact the NewTeam Customer Service Department Telephone 01536 264 012 for assistance Understanding your Shower e If the performance of your shower deteriorates and runs continually hot ensure that the handset or hose has not become restricted e Itis the speed of water passing through the heating elements that directly determines the showering temperature The slower the water passes through
16. the guarantee card helps NewTeam to process any claims and contact you about your product and its maintenance if required The registration of your personal details is purely for Newteam use and the other information helps us to make products for the future NewTeam products are designed manufactured and tested to the highest standards Should a complaint arise products are guaranteed against faulty workmanship and materials for a period of 12 months from the date of purchase when in domestic use For your guarantee to be valid your NewTeam shower must be installed by a competent person in accordance with the instruction manual NewTeam Ltd will repair or replace at our option free of charge any faulty component during the guarantee period provided it has been maintained and operated in accordance with our instructions and has not been misused or damaged Modification or repair of this product by persons not authorised by NewTeam Ltd will invalidate this guarantee This guarantee applies to products purchased within the United Kingdom or Republic or Ireland but does not apply to products used commercially This guarantee does not affect your statutory rights Service Policy Replacement Parts Policy Important In the event of product or component malfunction DO NOT tamper with or remove the product from site Telephone NewTeam Customer Service Department on 01536 264 012 and be prepared with the date of purchase model number
17. tting of the temperature control will vary in some months of the year due to the change in temperature of incoming mains water User Instructions Control Features See Fig 7 1 Standby Indicator 2 Power Selector 3 Temperature Control 4 Reduce Temperature Indicator 5 Low Pressure Indicator 6 Pressure Relief Outlet Grill Operating your Shower Fig 7 e Ensure that both the water and electricity supplies to the shower are turned on When the Standby light 1 is illuminated the shower is ready for use e Rotate the Power Selector control 2 to the desired power setting e Rotate the Temperature Control 3 until your desired showering temperature is achieved Spare Parts Listing i3 iea rig an i bad ee lar glaei tal C No Part No Description 7 8 8 5 9 5 10 4 01 SP 092 0506 7 8kW Heating Canister X 02 SP 092 0501 8 5kW Heating Canister X 03 SP 092 0502 9 5kW Heating Canister X 04 SP 092 0504 10 4kW Heating Canister X 05 SP 092 0425 PRD Cap amp Shear Pad XIXI IXI X 06 SP 092 1042 Stabiliser Valve High Flow XIXIXIX 07 SP 092 0423 Temperature Clicker X X X X 08 SP 092 0426 Solenoid X X X xX 09 SP 092 0291 Pressure Switch Assembly X X X X 10 SP 092 0150 Low Pressure Microswitch with Lever X X X X 11
18. voice by cheque or postal order By telephone quoting credit card Mastercard Visa or Visa Delta details Replacement Parts Tel 01536 409 222 Fax 01536 409 201 E Mail spares newteam co uk Customer Service Hotline Tel 01536 264 012 Fax 01536 409 201 E Mail service newteam co uk Guarantee Card Guarantee Card Please post immediately enclosing a copy of proof of purchase NewTeam 7 8 OQ For NewTeam Use NewTeam 8 5 O NewTeam 9 5 O This label identifies your NewTeam 10 4 Q product and provides all the Proof of purchase enclosed Yes Q No Q mromation needed Name Mr Miss Mrs Address Postcode Date of Purchase Where Purchased Town NewTeam s philosophy is to offer outstanding products with quality and integrity please be kind enough to help us by taking the time to answer the following questions Thank you Marketing Information 1 Please state your profession Plumber Q Builder Q Electrician Q Customer Q Other Q Please specify 2 Please state reason for purchasing shower New Build Q Replacement O Renovation Q Other Q Please specify 3 If the product is a replacement shower please state the type and make of shower it is replacing 4 What influenced your purchase Advertising Q Trade Press Q Recommended by Stockist Q Recommended by Installer Q Other O Please specify 5 Please state your main reason for purch
Download Pdf Manuals
Related Search
Related Contents
鋼材が簡単に持ち運べる 人力運搬用クランプ ワンタッチで操作! 確実に Paradise Lost™ Standard Cabinet Operation & Service Manual Rexel Polypropylene Indexes Alphabetical MGPS-PNTM System Board User's Guide Billy Goat BC2403 Brush Cutter User Manual HOW TO PAINT EXTERIOR SURFACES MODMECA & MODELEC MICHAEL WEINIG AG Conditions de livraison de MICHAEL WEINIG Manuel d`utilisation : M VADAR User Manual Copyright © All rights reserved.
Failed to retrieve file