Home

Master User Guide

image

Contents

1. N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A INS177 65 Notes Premier Series Master User Guide 66 INS177 Premier Series Master User Guide Notes INS177 67 Installation Company Details Installation Engineer Installation Company Address Telephone Number Installation Date Service Record Date Serviced Comments Engineer Emergency Telephone Numbers For 24 Hour Call Out For Anti Code Reset Control Panel Details Model Premier 24 Premier 48 Premier 88 Premier 168 Location TEXECOM LTD 2008 INS177 6
2. Add Eng Code NVM Locking INS177 47 Programming the Alarm System Premier Series Master User Guide User Options 1 This menu defines which options are available to the user when their code is entered This menu is not available to all users Press to scroll through the options and press to select them or use keys a Letter option IS selected Star option is NOT selected The following options are available A Arming Areas assigned to the selected user can be armed D Disarming Areas assigned to the selected user can be disarmed O Omitting Zones assigned to the same areas as the selected user can be omitted providing that they have the Omit attribute assigned to them R Eng Reset Engineers onl Areas programmed as Engineer Reset can be reset after an Alarm has occurred a Local Arming not on Premier 24 The User can only arm areas that the keypad is assigned to d Local Disarm not on Premier 24 The User can only disarm areas that the keypad is assigned to or areas that are in entry or alarm provided that the code has that area assigned to it Y Auto YES After a code is entered pressing to confirm the next action is not required F Disarm First not on Premier 24 If an area is armed and the user enters their code the Disarm option is displayed first The following attributes are only available on the Premier 24
3. Door Strike Vacation Custom Arming Arming Arming Arming Arming Arming Arming Arming Arming Disarming Disarming Disarming Disarming Disarming Disarming Disarming Disarming Omitting Omitting Omitting Omitting Omitting Omitting Omitting Omitting Eng Reset Local Arming Local Disarm Disarm First Disarm First Disarm First Disarm First User Options 2 Disarm First Disarm First Engineer Master Manager Standard Local Duress Arm Only Door Strike Vacation Custom User Menu User Menu User Menu User Menu User Menu User Menu User Menu User Menu Eng Program Vacation Door Strike Door Strike Door Strike Call Rem PC Call Rem PC Call Rem PC Duress Code Open Close Open Close Open Close Open Close Open Close Open Close User Config Open Close Open Close Open Close Engineer Master Manager Standard Local Duress Arm Only Door Strike Vacation Change Code Change Code Change Code Change Code Change Code Chime Zones Chime Zones Chime Zones Chime Zones Chime Zones Change Timer Change Timer Change Timer System Tests System Tests System Tests Setup Users User Setup Eng Access
4. pA Some of the following options may not always be selectable or de selectable T Lock TAG PGM2 The Users TAG is disabled whenever PGM2 is active C Lock Code PGM3 The Users code is disabled whenever PGM3 is active default during the Entry mode U Lock User PGMA The Users TAG and Code is disabled whenever PGM4 is active default Control Timer 4 O Open Close The selected user will report open disarm and close arm events to an Alarm Receiving Centre every time they arm or disarm 48 INS177 Premier Series Master User Guide Programming the Alarm System User Options 2 This menu defines which options are available to the user when their code is entered This menu is not available to all users Press to scroll through the options and press to select them or use keys a Letter option IS selected Star option is NOT selected The following options are available U User Menu The selected user has access to the User menu However the selected user will only have access to options assigned in User Config see page 50 for details E Eng Program Engineers onl Only Available to Engineers D Dual Code The selected user can only access an area when a second User code with the Dual Code attribute and also assigned to the same area is entered Dual Code users will also activate the 15 and 2 Code output type V Vacation The selected user is enabled the first t
5. Enter a valid User code 2 RARO 0 Press Press Press until the display looks like this Press Press 4 gt to select the required number Press to edit the number Enter the required mobile phone number then press Press when finished Press to exit the menu The display will return to normal 60 INS177 Premier 8 Series Master User Guide Specifications 5 Specifications European Standards Conforms to European Union EU Low Voltage Directive LVD 73 23 EEC and Electro Magnetic Compatibility EMC Directive 89 336 EEC The CE mark indicates that this product complies with the European requirements for safety health environmental and customer protection This equipment is designed to enable an intruder alarm system in which it is installed to comply with the requirements of security grades 1 or 2 of EN 50131 1 and EN 50131 6 and is suitable for installation in any indoor environment Warranty All Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the control panel is covered by a two year warranty against defects in materials or workmanship As the control panel is not a complete alarm system but only a part thereof Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the control panel failed to function correctly Due to our policy of continuous improveme
6. eeeeseseeeeeeeeeeeee nennen nnne nnn nnne nnne nennen 21 USER Reset aene eec se cipe ba rr aen aer dela ce eden Pe dd e nea aa du uad 21 ENGINEER Reset ccoo tia pner APO ERR enone 21 Izd lm 23 To Turn CHIME On and Off ccsseeececeeseeeeeeeeeeeeeeeeeneeeeseeesseeeeneeeeseeeaesseeeeeeeeeeneeeaes 24 To VIEW the Status of Zones esses eene nnne nnn nannten 25 To OMIT 24 Hour Zones eeseeeseseeees esee nnn nnne nnnn nhan nnn nnne nnns nnne 26 To SELECT Areas for Chime eeeeeeseeeeeeeeeeeeeee eene ennt nnne nnn nnns 27 To VIEW Activity Faults eeeeeeeeeeeeeee eene eene nennen nnne nnns nena 28 To VIEW Activity Counts eeseeeeeeeeeee eene enne nnne nnn nnne nnn nnne nnn nnne 29 Sending a Text Message to a Mobile Phone eee 30 Premier 48 88 168 only eese nennen nnnm rencor enana nenas 30 2 INS177 Premier Series Master User Guide Overview 4 Programming the Alarm System seeeeeeee 31 Introduction E 31 Viewing the Event Log eese cnn nacer 32 Event Log DesctiptiOris eei peto ecce opere eras 33 Changing Your User Code sssneneesneesnensnnnnes 35 Setting up Zones for Chime eeeeeeeseeeeee
7. Built in Proximity Reader for use with Proximity TAGS approximate range is between 1 and 5 cm Proximity TAGS can be used as an alternative to a Code number LED Indicators Five LED indicators have been provided to indicate the status of the system LED Status Meaning Power On AC mains is present on the control panel Flashing AC Mains is not present the control panel is running on the standby battery Service On The system requires attention contact your installer Off The system does NOT require attention Ready On All zones are secure and the system is ready to be armed Off One or more zones are active Flashing The system has zones with the Force Omit attribute that are active On The system is armed can also be programmed for other indications Off The system is unarmed can also be programmed for other indications On One or more zones are omitted Off No zones are omitted 6 INS177 Premier Series Master User Guide Overview Keys Keys QD to These keys are for entering User codes or programming data Yes amp No Keys amp The YES key is used to accept actions and the NO key is to cancel actions or edit data Omit Key This key is used to omit zones see page 23 for details Chime Key This key is used for turning the chime facility on and off see page 24 for details and also for turning the Exit tones on and off during the exit mode Part Key
8. Door Strike users have no access to User functions or Menu options However Door Strike users will activate any outputs programmed as Door Strike whenever their code is entered 8 Vacation Vacation users behave as Standard users However Vacation users are automatically deleted the first time that the Master User code User 01 is used to disarm the system A A Vacation user is only deleted by the Master user after it has been used to disarm the system at least once 9 Custom Custom users can access any functions and User menu options that have been assigned to them in User Options 1 or 2 and User Config This flexibility allows new User types to be created that have their own unique set of characteristics Any number of Custom users can be assigned to the system and each one will respond differently depending on the functions and features that have been assigned to them 46 INS177 Premier Series Master User Guide Programming the Alarm System Available Options The table below shows the options that are available to each user pA All users that have access to the Arming Menu have the ability to View Zone Status Set Chime Areas View Act Faults and View Act Counts All users have access to the User Menu have the ability to View Event Log Adjust Volumes and Print Event Log User Options 1 Engineer Master Manager Standard Local Duress Arm Only
9. Edit Chime Zones option allowing them to select which zones chime when activated see page 36 for details T Change Timers The selected user can access the Override Timers see page 42 for details Alter Timers see page 43 for details Alter Part Arms see page 55 for details Alter Hol Dates see page 57 for details and Edit Phone No see page 60 for details menu options S System Tests The selected user can access the System Tests option allowing them to walk test Zones activate the external sounder etc see page 37 for details U Setup Users The selected user can access the Setup Users option allowing them to alter existing users or assign new users see page 45 for details However users cannot assign User types to the system that have a higher access level than themselves Also if a user assigns a Custom User type functions that are not available to them cannot be assigned to the Custom user E Eng Access The selected user can access the Enable Engineer option allowing them to authorise Engineer access or Remote UDL access to the system see page 32 for details A Add Eng Code Engineers only Only Available to Engineers N NVM Locking Engineers onl Only Available to Engineers 50 INS177 Premier Series Master User Guide Programming the Alarm System User Name Text Each user can be assigned up to 8 characters of name text This can be beneficial when reading t
10. This key is used to part arm the system see page 16 for details It can also be used to do a Quick part arm if this feature is enabled Area Key This key is used to arm or disarm particular areas see page 17 for details It can also be used to do a Quick arm if this feature is enabled Reset Key This key is used to exit from a menu or to reset the system see page 21 for details Scroll Key D This key is used to scroll through the various menus and options and also to slow down the display if it is scrolling through alarm information too fast Menu Key This key is used to select the Arming or User menu Emergency Keys In case of emergency the alarm system can provide three immediate emergency alarms by pressing and holding two specific keys Press Keys UK Response Export Response CD Panic Alarm PA Fire amp Fire Panic Alarm PA 8 Medical Medical pA The emergency keys can be enabled disabled for each keypad on the system The Panic alarm can be programmed for either audible or silent operation The Panic alarm can be programmed for either instant or delayed operation INS177 7 Overview Premier Series Master User Guide The Quick Arm Keys The Quick Arm keys allow the system to be armed without having to enter a User code first PS The Quick Arm keys will only work if the keypad has been programmed to allow arming in this way To FULL arm the system press Crea To
11. amp off proceed as follows Enter a valid User code gt RARO Press Press Press C until the display looks like this Press Use keys gt to toggle control timers on and off i e 1 Timer 1 Press when finished Press to exit the menu The display will return to normal 42 INS177 Premier Series Master User Guide Programming the Alarm System Altering the Control Timers The system has Control Timers Each timer has two ON and OFF times and can be programmed to operate on any day of the week Once configured the timers can be used to automatically arm or disarm areas lockout User codes and control outputs etc Users with access to this option can program the Control Timers To program control timers proceed as follows Enter a valid User code DDD Press Press Press until the display looks like this Press Use C to Select a Control Timer from 1 to 8 Enter the first On time 24 Hour format CH CH CM CMD Press when finished Use keys gt to select the On days SUN to SAT i e C1 and Sunday and Monday INS177 43 Programming the Alarm System Premier Series Master User Guide Press when finished Enter the first Off time 24Hour format CH CH CM CM Press when finished Use keys gt to select the first Off days SUN to SAT i e and Friday and Saturday Press when finished Repeat programming for the timers Second On times On days Off times
12. SILENCE an Alarm When an alarm occurs on the system the internal and external sounders will normally sound for a pre programmed time normally 15 minutes PS If you were not present when the alarm activated the internal and external sounders may have already stopped but the external strobe will still be flashing When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events To silence an alarm proceed as follows The alarm will be sounding and the display will look something like this Enter a valid User code DDMA The internal and external sounders will stop and the number of the zone that caused the alarm will be displayed in this case Zone 2 The alarm now needs to be reset To DISPLAY the cause s of System Alerts Alarms When silencing an alarm or unsetting the system after an alarm the number of the zone s will be displayed on the keypad If several zones were triggered the display will scroll through each in turn After noting the cause of the alarm the system can be reset as described in RESET After an Alarm below System Alerts When the system has faults to display or has not been reset after an alarm condition the display may show SYSTEM ALERTS Enter a valid User code DDD Any alarms or faults will be displayed If several fault or alarm conditions have been triggered the display will scroll through each in
13. many incorrect code entries will cause a Tamper alarm or lock the keypad out The User code may not allow access to certain functions i e if the code is only allowed to arm and disarm area A it will not be able to arm or disarm other areas on the system Most User codes can arm and disarm areas assigned to them from any keypad on the system However Local Users will only be able to arm and disarm areas assigned to them from keypads assigned to the same areas As well as or instead of a code users of the alarm system can be assigned a Proximity TAG Proximity TAGS replace the code number being entered with a key ring type TAG that is presented to the reader inside the keypad to operate the alarm system Zones A zone is part of the protected premises and may consist of one or more detection devices protecting rooms and points of entry exit e g front door kitchen downstairs windows upstairs bedrooms etc When the alarm system is fully armed all of the zones on the system are monitored Some zones may belong to more than one area such as points of entry exit i e the front door and movement sensor in an entrance lobby These are called global zones because they are assigned to multiple areas A zone that is assigned to more than one area will only be monitored when all of the areas it is assigned to are armed 4 INS177 Premier Series Master User Guide Overview Areas An area is a group of one or more z
14. the exit tone will resume when all zones are secure If it is necessary to leave a zone open then it must be omitted see page 23 for details pA If an active zone cannot be secured then it may be in fault in this case contact the alarm company immediately Arm Fail Failing to Arm If the exit procedure is started and zones are still Active at the end of the exit procedure an Internal alarm will occur internal sounders only and the strobe light on the external sounder will flash pA If this occurs the arm fail must be cleared and the zone in fault identified before the system can be armed see page 19 for details on clearing an Arm Fail The Ready LED To help prevent faults during arming a Ready light has been provided The Ready light works as follows e Ifthe Ready light is ON then all zones are secure and the system is ready to be armed e If the Ready light is OFF then one or more zones are active either secure or omit these zones before proceeding e Ifthe Ready light is FLASHING then the system has zones with the Force Omit attribute that are active check these zones before proceeding INS177 11 Overview Premier Series Master User Guide 2 Using the Alarm System Introduction The operation of the system is divided up into two sections the Arming menu and the User menu To access the Arming menu enter a valid User code DOTO Once in the Arming menu various functions can be selected by us
15. to search To Program a Code To Assign a TAG To Assign a FOB Press Press Press Enter the new Que Press any of the User code buttons on the HD to exit Radio FOB A confirmation tone will be heard o o o E E o The code can be 4 5 or 6 digits long Present the TAG to The Prox symbol Press on the keypad See next page A confirmation tone will be heard CR Tag importing is not available on the Premier 24 52 INS177 Premier Series Master User Guide Programming the Alarm System From Previous page Use keys gt to select deselect areas then press Use keys gt to select a User type or use the key to search Refer to page 45 for a list of available User types Press These options are only displayed if a Custom User type is selected Press C to scroll through options and press to select the option Letter option IS selected Star option is NOT selected Press to select Options 2 and press to edit Press to select Config and press to edit The following option is only displayed if User Menu has been selected see above Press Use keys C D to select a timer if required then press Press to edit the User name text press when finished For details on programming text please refer to page 51 Press INS177 53 Programming the Alarm System Premier Series Master User Guide This option is only displayed if a User with the Doo
16. view the zone status to find out which zone has not activated then activate the zone to clear the fault A fuse has blown the alarm will sound enter a valid User code to silence the alarm this fault cannot be cleared Contact your alarm company immediately Zones that have been placed on test by the engineer have failed the test the system can still be used Contact your alarm company to advise Too many invalid code attempts have caused the keypad to lock out The keypad will normally remain like this for 5 minutes Areas are being armed using one of the control timers enter a valid User code to defer the arming The alarm engineer has logged into the programming menu and is working on site this message will clear when the engineer logs off or the system is armed T m E o 17 17 D Q e DA When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events 10 INS177 Premier Series Master User Guide Using The Alarm System Zone Faults During Arming Before attempting to arm the system ensure that the premises are secure all doors and windows closed etc and the Ready light is on If an attempt is made to arm the system with any zones active e g door ajar open window etc the internal sounders will bleep repeatedly fault tone and the display will show the zones that are active The fault tone will stop and
17. was armed automatically using one of the timer controls TIME Disarmed Area was disarmed automatically using one of the timer controls DEFERRED The arming mode was deferred for area ALARM ABORT An Open After Alarm Abort has occurred for area REMOTE Armed Area was armed using the Wintex UDL software REMOTE Disarmed Area was disarmed using the Wintex UDL software QUICK Armed Quick Arm from keypad RECENT Armed Area has been armed recently RESET AREAS Area have been reset using keypad following an Intruder alarm Engineer Reset A reset has been performed using an Engineers code Anti Code Reset A reset has been performed using the Anti code reset procedure Remote Reset A reset has been performed using the Remote Reset input Redcare Reset A reset has been performed by the Redcare Key switch Reset A reset has been performed using a key switch User Reset A reset has been performed using a User code EXP Reset A reset has been performed using the input on expander INS177 33 Operating the Alarm System Remote PC Reset A reset has been performed by the remote download PC FUSE FAIL The Auxiliary 12V Fuse in device has failed AC POWER The control panel has registered a AC Mains failure LOW BAT The control panel has registered a low battery condition POWER
18. 2 a Master User Guide Premier 24 48 88 168 im m f CE nm Overview Premier Series Master User Guide O AAA A 4 A O O 4 Keypads AAA 6 Emergency Keys iaa Petri eri eee DIE EE e rider 7 Th Quick Arm KEYS T sit tod e titled fone itd etit ede d 8 Keypad Lock arsi ien Ge ec ere pedet ue etie eigo 8 Alert Reset and Service Messages ne 9 Fault Messages sic iret tede te ete lr fe eate lee tee xerit tla aes 10 Zone Faults During Arming ueeeeeeeeeeeeeeeeeeee ennemis 11 2 Using the Alarm System eeeese eese 12 INtPOAUCHON ico ne eedannsannite 12 3 Operating the Alarm System eeeeeeeeeeeseeeeeeu 14 Introduction 14 To FULL Arm the System ini isniia 15 To PART Arm the System isnnennnnnnne 16 To ARM Individual Areas eese nennen eene nnne nnnm nnns nnn 17 To DISARM the System ice iia diand 18 During Batty acopiar 18 When Not in Entty i iii ka Rienda 18 To CANCEL the EXit MOdE c iooocacccicnacicione naci tienda 19 To CLEAR an Anim Falilicciscenccc cece sce ceeceadecdeccceseseendesanceucennstevecananedessaececesecnestsnncicesaetes 19 To SILENCE an Alarm ee cecinere tecla tee iie en eite Erie 20 To DISPLAY the cause s of System Alerts Alarms eere 20 To RESET After an Alarm
19. 4 User Types The User type determines which functions are available to the user i e arming disarming resetting etc and also which options the user can access i e Setup Users System Tests etc 5 User Time Lock This option allows the selected user to be denied access to the system at different times of the day and days of the week When a Control Timer is assigned to a user the User code will not allow access to any functions during the timers On period 6 User Name Text Each user can be assigned up to 8 characters of name text The name text is displayed whenever a code is entered and also when reading the log making identification of people using the alarm easier 7 Door Control This option would normally be used for access control Users are able to open unlock doors that are assigned to their user code 8 Proximity TAG As well as or instead of operating the alarm system with a 4 5 or 6 digit code number it is also possible to operate it by presenting a Proximity TAG to the keypad this requires a Proximity keypad INS177 45 Programming the Alarm System Premier Series Master User Guide User Types The User type determines which functions are available to the user e arming disarming resetting etc and also which options the user can access e Setup Users System Tests etc The following User types are available 1 Master Master users can arm disarm omit zones silence alarms and reset their a
20. ED UP System Power Up without doing a factory restart BELL FUSE The control panel Bell Fuse has failed ATS FLT Alarm There is a problem with the telephone line Panel Line Fault The control panel line fault input has been activated Redcare Line Fault The Redcare has detected a line fault Com Line Fault The Com300 2400 or ISDN has detected a line fault Exp Line Fault The Input on expander has been activated COMS FAILED The Communicator has failed to report to the Alarm Receiving Centre DOWNLOAD START An Upload Download has been initiated DOWNLOAD END The Upload Download has finished LOG ALERT 80 of the Event Log has filled since the last Upload Download DATE CHANGED The control panel Time has been changed TIME CHANGED The control panel Date has been changed Event Log Hotkeys When viewing the system log there are 9 hotkeys available These hotkeys allow certain events to be found easier without the need for searching The following hotkeys are available D Priority Alarms PA Fire etc Normal Alarms Guard 24hr Entry Exit etc Opens and Closings Arm Disarm etc Omits and Reinstates Zone Omits etc Gx Maintenance System Tests Engineer Program etc Tampers Zone Bell Aux etc Test Calls Communicator Active successful etc Entry Exit Entry and Exit Procedures User Codes User code
21. PART arm the system press 1 5 or followed by Ca Keypad Lock The keys on the keypad can be locked to prevent unwanted access to the system A The Emergency keys will NOT operate with the keys locked To Lock the keys press and together To Unlock the keys press and together again 8 INS177 Premier Series Master User Guide Overview Alert Reset and Service Messages System Alerts When an alarm or fault condition exists on the system the keypad will display a warning message In order to display the alarm or fault condition s that generate this alert enter your user code a scrolling display will show all alarm fault conditions on the system When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events The messages that can be displayed are shown in Reset and Service messages below and in Fault Messages on page 10 Reset and Service messages When the system requires a reset service the display will show one of three messages These messages can also be accessed at any time from the normal display PS These messages may have been changed by the installer and may contain the telephone numbers of the installer or the Alarm Receiving Centre To display the reset service messages proceed as follows Press followed by 1_ gt to view the Service message Press followed by to view the Reset message Press followed by to view the A
22. ULL or PART arming as required Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on Enter a valid User code DDD To select areas for full arming proceed as follows Press Use keys D to select the required area 0 selects deselects all Areas Press or to FULL arm The exit tone will sound if silent arm has not been selected Leave the premises When the areas have armed the exit tone if sounding will stop The selected areas are now armed To select areas for part arming proceed as follows Press CDAD or followed by Then select the area s to part arm as for full arm above INS177 17 Operating the Alarm System Premier Series User Guide To DISARM the System The Entry time is divided into two sections the Entry time and the 2 Entry time If the Entry time expires an Internal alarm will occur and the 2 Entry time will start If the 2 Entry time expires an Intruder alarm will occur all internal and external sounders pe It is perfectly normal for the 2 Entry time to be programmed as zero in which case an Intruder alarm will occur as soon as the Entry time expires During Entry To disarm the system proceed as follows Enter the premises via the designated entry point The entry tone will start Enter a valid User code ADDED The entry tone will stop The system is now disarmed When Not in Entry To disarm the system proce
23. and Off days Repeat for other Control Timers Press when finished Press to exit the menu The display will return to normal 44 INS177 Premier Series Master User Guide Programming the Alarm System Adding New Users to the System When the control panel is first installed only the Engineer code and the Master User code exist additional users need to be added to the alarm system manually D The factory default Master User code is Gu Gm 7 2 8 5 The Master User code is always User 01 and can never be deleted Programming New Users Each User on the system is made up of the following elements 1 2 or 8 3 and 4 these are essential for the code TAG to function correctly items 5 6 and 7 are optional 1 User Number When users are assigned to the system they need to be identified by the control panel Each user is identified as Users 01 02 03 etc User 01 is always the Master User 2 User Code This is a unique 4 5 or 6 digit code number that is assigned to a user the system will allow a mixture of different lengths The User code must be entered at a keypad to operate the alarm system 3 User Areas Any number of areas can be assigned to the selected user Assigning areas to a user determines which areas can be armed disarmed reset etc by that user In addition assigning areas to a user determines which of the area related functions i e omitting zones silent arming etc will be available to that user
24. ed as follows The display will look something like this Enter a valid User code DD DD Press The system is now disarmed 18 INS177 Premier Series User Guide Operating the Alarm System To CANCEL the Exit Mode Once the exit mode has been started you should leave the premise immediately however if for some reason you decide not to leave the exit mode must be cancelled To cancel the exit mode proceed as follows Enter a valid User code DODDA Press The exit tone will stop The exit mode has now been cancelled To CLEAR an Arm Fail When the system tries to arm with zones active open the internal sounders will sound and the external strobe will be flashing to indicate a problem For details on preventing an Arm Fail condition please refer to page 11 Note f you were not present when the arm fail occurred or you do not clear the arm fail the internal sounders will continue to sound and the external strobe will continue to flash To clear the arm fail proceed as follows The alarm will be sounding and the display will look something like this Enter a valid User code DDMA The internal and external sounders will stop the external strobe will continue to flash and the number of the zone that caused the arm fail will be displayed in this case Zone 2 Enter a valid User code DODDA and press The arm fail has now been cleared INS177 19 Operating the Alarm System Premier Series User Guide To
25. ee esee nennen nennen nnne nnne 36 Testing the Sounders and Strobe sise 37 Walk Testing the System since 38 Enabling Engineer Access eese eene nennen nisse nenne 39 Setting the System Time ss ssssssnnreenneennneennennsnnnee 40 Setting the System Date ss esnnresnenensneneensnnenensnnenennnnnee 41 Overriding the Control Timers sn 42 Altering the Control Timets cette rei soni catalana erronee epos ek aepo oceano si inis 43 Adding New Users to the System rennes 45 Programming New Users ener eene nderit einen nente nennen 45 User Types ea diee iro ie eite EHE OR f de eater be Hue tole ud 46 Available OPINAS 152 cei armee ia 47 User Options xdi to Gene m P ace Ege Ptr Fe ERR RR 48 USer Optiolns 2 0 22 eset eds deste ibant eee eter ite sao od 49 User Co Oia e p nS ib bed a 50 User Name Text tuere mea Tert etre ie Dee ERR EROR PUR Eg ae 51 Programming Sears ite irte a 52 Deleting Users tnt eon ep eec e Det pt Sgen 54 Setting up the Part Arms cccesecceseeeeceseceeeeeneeeeceneceesesneceseneneeeenseceeessnecennsneeeres 55 Calling a R mote PC 5 unii aa 56 Altering the Holiday Dates Premier 48 88 168 only 57 Adjusting Speaker Volumes Premier 48 88 168 only 58 Printing the Event Log eeeeeeeeeeeeeeeeee nennen cnn cnn cnc cnn nn 59 Editing a Mobile Tele
26. ess The Chime tone will sound To turn CHIME Off proceed as follows Press The Fault tone will sound 24 INS177 Premier Series User Guide Operating the Alarm System To VIEW the Status of Zones Users with access to this feature will be able to check the status of each zone on the system to see whether it is in Fault Secure Tamper Shorted or Inactive To view the status of zones proceed as follows Enter a valid User code C gt C C C Press Press Enter a zone number DO CD C gt or use the key to search Pressing will make the zone chime every time it is activated an Arrow will appear to the right of the zone number to clear the Chime press again Pressing will display the zone text Every time the selected zone is activated its status will be displayed and the keypad will chime if selected Press when finished Press to exit the menu The display will return to normal INS177 25 Operating the Alarm System Premier Series User Guide To OMIT 24 Hour Zones It is possible to exclude omit or include 24 Hour zones whilst the system is disarmed to allow access to an area Users with access to this function can only omit zones that have been programmed as Omittable PS If the zone can be omitted there will be a star to the right of the zone number Only zones that have the Omit attribute assigned to them can be omitted A star w
27. fice is disarmed Because the foyer is a global area used by everyone the zones in that area need to be assigned to areas A B and C This ensures that the zone is only recognised by the system when ALL areas A B amp C are armed allowing access to the foyer even if one of the areas is still armed Monitoring This alarm system is capable of reporting Intruder alarms Panic alarms Fire alarms and other types of information over telephone lines to an Alarm Receiving Centre If you accidentally set the alarm off call the Alarm Receiving Centre immediately to prevent an unnecessary response nore The monitoring function must be enabled before it will work INS177 5 Overview Premier Series Master User Guide Keypads One or more keypads will be installed throughout the protected premises usually one at each entry exit door The keypads are used to perform all of the system functions i e Arming Disarming etc Premier LCDL LCDLP Premier LCD LCDP Large Display Standard Display Programmable Proximity Reader Info LED LCDP amp LCDLP keypads only a 2 abc 3 der Omit Reset Normal 4 oni 5 iki 6 mno Chime A Function Keys T pars 8 tw 9 wyz Part v Keys Yes es No Area Menu ar Display Window Premier LCD LCDP 8 LCDL LCDLP The 32 Character LCD display is used to show the status of the system and to view system data Proximity Reader Premier LCDP 8 LCDLP only
28. g disarming omitting zones etc PS The range of available functions and options will depend on the control panel being used some control panels do not support all of the features and also the type of user on that system Not all functions are available to all users If a function cannot be selected it may be that it is not assigned to that user see page 47 for details If no keys are pressed the display will return to normal after a pre programmed time The table below shows the various functions available Arming Menu Function A o lt Arm System Part Arm System Silent Arming Cancel Exit Disarm the System Use Anti code Omit Zones View Zone Status Omit 24Hr Zones Set Chime Areas View Act Faults View Act Counts Send SMS Text User Menu a Gd 14 INS177 Premier Series User Guide Operating the Alarm System To FULL Arm the System The system is FULL Armed when ALL zones are ON not omitted PA Your Installer may have programmed the system so that it can be set by just pressing Garea if this is the case then there is no need to enter the User code below To arm the system proceed as follows Ensure that the premises are secure all doors and windows closed etc and the Ready light is on Enter a valid User code DDD Press to Silent arm if required Press to arm The exit tone will sound if silent arm
29. has not been selected Leave the premises When the system has armed the exit tone will stop if sounding The system is now armed INS177 15 Operating the Alarm System Premier Series User Guide To PART Arm the System The system is PART Armed when ONE OR MORE zones have been left OFF omitted i e the landing or a bedroom D The system is only Part Armed when zones are omitted using the Part Arm procedure omitting zones manually see page 23 for details is not classed as Part Arming The bottom line of the display is programmable for each Part Arm Your Installer may have programmed the system so that it can be part armed by just pressing QD or followed by if this is the case then there is no need to enter the User code below To part arm the system proceed as follows Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on Enter a valid User code DDD Press Use keys gt to select the required part arm Press to arm normally or press to arm silently The exit tone will sound if silent arm has not been selected Leave the protected area When the system has armed the exit tone if sounding will stop The system is now part armed 16 INS177 Premier Series User Guide Operating the Alarm System To ARM Individual Areas If the system has been set up for multiple areas each area can be individually selected for F
30. he log as identification of people is made easier Text is programmed in a similar way to mobile phones Characters are selected by pressing the corresponding key the appropriate number of times to select a character on the same key press C to move the cursor along Some control panels also features Predictive text This can be used to make inserting words easier e when spelling the word COLIN instead of typing 222666555444666 all that you need to do is type 26546 and the word is automatically selected PS It is advised that predictive text be turned off when programming User name text as the library is not comprehensive enough to include all known names The library cannot be edited e words cannot be added or changed The table below shows the keys to use and the characters that are assigned to them Character A lt o CIO Z A T M O A D G J M P w x lt Y Z Move Cursor Backspace delete Copy Text Paste Text Predictive Text a Ge Upper Lowercase Predictive text and Clear Screen INS177 51 Programming the Alarm System Premier Series Master User Guide Programming Users To Program Users proceed as follows Enter a valid User code 2 RARO Press Press Press until the display looks like this Press E Select a user DO CD or use the gt key
31. ill appear to the left of the zone number to indicate that the zone has been selected for omitting To re instate the zones simply follow the instructions again However when the key is pressed on this occasion the zones will be re instated To omit 24 Hour zones proceed as follows Enter a valid User code DODA Press Press Enter a zone number DO CD CD or use the key to search Press to omit the selected zone Repeat for other zones Press when finished Press to exit the menu The display will look like this The selected 24 Hour zones are now omitted 26 INS177 Premier Series User Guide Operating the Alarm System To SELECT Areas for Chime When a zone is enabled for Chime the Keypad will generate a chime tone every time the zone is activated Users with access to this function will be able to turn Chime on and off for selected areas Zones within an area can be individually programmed for Chime in Edit Chime Zones see page 36 for details e Only areas that have been programmed for Chime can be selected A star means the area can be selected and a dot means the area cannot be selected Pressing will select deselect all areas Pressing will toggle between areas A to H and to P Premier 168 only To select an area for Chime proceed as follows Enter a valid User code D DDC Press Use keys gt to select deselect areas i e AD and Areas A Band C Press when finished Press
32. ime it is used to disarm the system and can be used as many times as required However it will be automatically deleted the first time that the User 01 code is used to disarm Vacation users will only be deleted by the Master user once they have been used on the system S Door Strike The selected user will activate any outputs programmed as Door Strike whenever their codes are entered R Call Rem PC The selected user has access to the Call Remote PC option allowing them to initiate a call to a remote Upload Download PC see page 56 for details C Duress Code The selected user will activate any outputs programmed as Duress whenever their codes are entered O Open Close The selected user will report open disarm and close arm events to an Alarm Receiving Centre every time they arm or disarm INS177 49 Programming the Alarm System Premier Series Master User Guide User Config This menu defines which menu options are available to the user when their code is entered This menu will only be displayed if a Custom User type is selected AND User Menu User Option U is enabled see page 49 for details Press to scroll through the options and press to select them or use keys a Letter option IS selected Star option is NOT selected The following options are available C Change Code The selected user can change their own User code Z Chime Zones The selected user can access the
33. ing the key Once a function has been selected press to access that function To access the User menu press followed by Cres Once in the User menu various options can be selected by using the C amp key Once an option has been selected press to access that option To exit from either menu press the key and the display will return to normal The diagram on page 12 shows both menus and the functions and options available PS The range of available functions and options will depend on the control panel being used some control panels do not support all of the features and also the type of user on that system If a function or option cannot be selected it may be that it is not assigned to that user see page 47 for details To access the Arming User menu proceed as follows The display will normally show the time amp date The top line is programmable To access the Arming menu enter a valid User code gt CARR To select the User menu Press Press to exit either menu The display will return to normal 12 INS177 Premier Series Master User Guide Using The Alarm System The Arming Menu CHERE ooet aR Se Benin SRE Sr o 0900000 1 The User Menu INS177 13 Using The Alarm System Premier Series Master User Guide 3 Operating the Alarm System Introduction The normal day to day operations of the system are carried out using the Arming menu i e armin
34. is option is used to adjust the volume level of speakers that are connected to the control panel keypads and expanders To adjust speaker volumes proceed as follows Enter a valid User code DDD Press Press Press until the display looks like this Press Press to select a Panel Keypad or Expander speaker Press then G D to enter a volume level 1 Minimum 8 Maximum Press to hear the new volume level Press to accept the new speaker volume Repeat for other speakers Press when finished Press to exit the menu The display will return to normal 58 INS177 Premier Series Master User Guide Programming the Alarm System Printing the Event Log If a printer or terminal is connected to the control panel this option can be used to print out events from the systems Event Log To print the Event Log proceed as follows Enter a valid User code RARO Press Press Press until the display looks like this Press Enter the number of required events DODDA Press to print the Event Log Press to exit the menu The display will return to normal INS177 59 Programming the Alarm System Premier Series Master User Guide Editing a Mobile Telephone Number If the control panel has been programmed to send SMS text messages to a mobile phone in the event of an alarm occurring etc this option allows the mobile telephone numbers to be programmed To edit a Phone Number proceed as follows
35. n to normal after a pre programmed time The table below shows the various options available User Menu A o lt Option View Event Log Change Code Edit Chime Zones System Tests Walk Test Enable Engineer Set System Time Set System Date Override Timers Alter Timers Setup Users Alter Part Arms Call Remote PC Alter Hol Dates Adjust Volumes Print Event Log Edit Phone No a Go INS177 31 Operating the Alarm System Premier Series User Guide Viewing the Event Log Users with access to this option can view the system Event Log This log records all of the events that occur on the system e Users entering their codes to arm or disarm the system alarms failures to arm etc along with the time and date on which they occurred e The down key moves you to the previous event backwards in time and the up key moves you forwards again The key toggles between the area information and the time date For a full list of Event Log descriptions please refer to the Master User Guide To view the Event Log proceed as follows Enter a valid User code CREARA Press Press Press Press C4 gt to scroll up and down through the Log Press to toggle between the area information and the time date Press to display zone text where applicable Press when finished Press to exit the menu The display will re
36. nti code message Press to exit from the messages The display will return to normal INS177 9 Overview Premier Series Master User Guide There is a Mains failure the keypad may chime every minute enter a valid User code or press to stop the chime The display will automatically clear when mains is reapplied There is a signal path fault the keypad may chime every minute enter a valid User code or press to stop the chime The display will automatically clear when line fault clears The signal path may be telephone line or mobile phone network There is a fault with the standby battery the keypad may chime every minute enter a valid User code or press Qese to stop the chime Contact your alarm company immediately There is a Tamper fault the alarm will sound enter a valid User code to silence the alarm this fault cannot normally be cleared Contact your alarm company immediately The service timer has expired indicating that the system requires a service or a fault has occurred that requires attention the system can normally still be used Contact your alarm company to advise The keypad has been disabled to prevent unauthorised access This normally occurs when a zone programmed as Security Key is active the display will automatically clear when the zone returns to normal A zone with the Activity attribute has not been activated within the activity time period this may be caused by an obstruction
37. nts Texecom reserve the right to change specification without prior notice Premier Keypads and Expanders are protected by UK amp International Registered Design Registered Design Number 2089016 and 3004996 Premier is a trademark of Texecom INS177 61 Installation Records Premier Series Master User Guide 6 Installation Records Areas Bell Duration Description Min Min Min Min Min Min Min Min Min Min Min Min Min Min Min Min Keypads Keypad Emergency Keys Location PA Fire Med 62 INS177 Premier Series Master User Guide Installation Records Zones Zone Part Arms Description 2 Tick Zones Included in Part Arms INS177 63 Installation Records Premier Series Master User Guide Zone Part Arms Description 2 Tick Zones Included in Part Arms 64 INS177 Premier Series Master User Guide Installation Records User Codes Type Default New Code Time Lock Master 5678 N A N A N A
38. one number on the last page of this User Guide INS177 21 Operating the Alarm System Premier Series User Guide ANTI CODE Reset If the system has been programmed to be reset using an Anti Code following an alarm activation you will still be able to silence the alarm by entering a valid User code see page 20 for details e The system cannot be armed again until the alarm has been reset To reset the alarm proceed as follows Enter a valid User code DODA Press The display will show a random code number i e 4281 Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide and quote the random code number You will be given a 4 digit Anti Code i e 5624 Enter the Anti code that has been given to you DOMA Press If the Anti code is correct the keypad will chime to indicate that the system has been reset and the display will return to normal 22 INS177 Premier Series User Guide Operating the Alarm System To OMIT Zones It is possible to exclude omit individual zones when arming i e if a zone is in fault Users with access to this function can only omit zones that have been programmed as Omittable wore f the zone can be omitted there will be a star to the right of the zone number Only zones that have the Omit attribute assigned to them can be omitted A star will appear to the left of the zone number to indicate that the zone ha
39. ones and would normally be used to split the premises into different sections Each area can be either Full armed or Part armed Example 1 Domestic Premises The entire house could be area A Each area can be Part armed For instance detection devices upstairs i e PIR s could be programmed so that they will not be monitored during a Part arm allowing access to the upstairs of the house at night PS Area A forms the entire alarm system Example 2 Domestic Premises The upstairs of a house could be area A the downstairs could be area B and the garage could be area C Each area can be Full armed independently from each other all detection devices in the area monitored For instance downstairs and the garage in example 1 areas B 8 C could be armed at night allowing access to the upstairs of the house area A A All of the areas together form the entire alarm system Example 3 Commercial Premises Office 1 in an office block could be area A office 2 could be area B and office 3 could be area C Each area can be armed and disarmed independently from each other For instance any of the offices in example 2 above could be armed and disarmed to allow access without affecting the other offices A All of the areas together form the entire alarm system Example 4 Office Block The foyer of the office block in example 4 would need to be armed when the last office is armed and disarmed when the first of
40. phone Number esses nennen 60 5 Specifications Lee Lee Lee Lee eee e cec eere eere euer eene nennen nenne nennen 61 European Standards 61 A assiste eneeeasa int XO XEM oos AERA es een imaa rene tan tanace nee sance nana n ten a Un 61 6 Installation Records mnnannnnnnennnnnnnnnnnnnnnennnnnns 62 INS177 3 Overview Premier Series Master User Guide Introduction The alarm system consists of a control panel one or more keypads and various detectors and sensors The control panel is normally mounted out of sight in a cupboard etc and houses the system s electronics and stand by battery There is normally no reason for anyone except an installer or service person to have access to the control panel The keypad is used to control the alarm system and to display its status via the English text display The keypad also provides audible feedback each time a key is pressed Each keypad will be mounted in a convenient location inside the protected premises near the designated points of entry exit Users Users of the alarm system will be assigned a unique 4 5 or 6 digit User code User codes are used to arm and disarm areas to which they are assigned Some User codes can also access additional options such as system tests and omitting zones To access the system a valid User code must be entered if a mistake is made whilst entering a User code simply re enter the correct code the system may have been programmed so that too
41. r Strike attribute is selected Use keys gt to select deselect doors then press Press 4 D to assign TAG to import or to ignore TAG programming Present the TAG to the Prox symbol on the keypad A confirmation tone will be heard Press when finished Press to exit the menu The display will return to normal ex Tag importing is not available on the Premier 24 Deleting Users To delete User codes proceed as follows Ensure that Setup Users is selected the display should look like this Select a user CD C then press Press Press to confirm deletion of the selected User code Press when finished Press to exit the menu The display will return to normal 54 INS177 Premier Series Master User Guide Programming the Alarm System Setting up the Part Arms When a Part Arm 1 2 or 3 is selected pre programmed zones are omitted to allow access to certain parts of the building This option allows these zones to be programmed or altered by any User that has access to the Omit menu To set up the Part Arms proceed as follows Enter a valid User code D DDC the display should look like this Press E Press Q Press Press E Press to select Part Arm 1 Press to select Part Arm 2 Press to select Part Arm 3 Enter a zone number DDO C or use the C gt key to search Press to turn zone ON or OFF for the selected Part Arm Repeat for other zones Press when finished Press to exi
42. s Press 0 E Press Q DD or use the C key to search Enter the zone number Press to select Chime Once for Chime 1 twice for Chime 2 etc Repeat for other zones if required Press when finished Press to exit the menu The display will return to normal 36 INS177 Premier Series Master User Guide Programming the Alarm System Testing the Sounders and Strobe Users with access to this option can test various system outputs to ensure that they operate correctly These include any outputs that have been programmed for specific operations i e bringing on floodlights sounding buzzers etc The internal sounders speakers and the external sounder can also be tested to ensure that they are operating correctly eR Any outputs that have been left On will be turned Off when the menu is exited To test the Sounders and Strobe proceed as follows Enter a valid User code DODDA Press E Press Press e E Press Press to select the BELL test Press 1 D to select the STROBE test Press to select the SPEAKER test Press to select the USER OUTPUTS test Press to select the DISPLAY test i e 2 for Speaker test Press to test the selected output Press Gens when finished Press to exit the menu The display will return to normal INS177 37 Programming the Alarm System Premier Series Master User Guide Walk Testing the System Users with access to this option can walk test any of the zone
43. s been selected for omitting All omitted zones will be automatically reinstated the next time the system is disarmed unless programmed otherwise To re instate zones manually simply follow the instructions again However when the key is pressed this time the zones will be re instated To omit zones when arming proceed as follows Enter a valid User code DODDA and press Enter a zone number D D D or use the key to search Press to omit the selected zone Repeat for other zones if required Press when finished Continue to arm the system as normal The selected zones are now omitted the omit light will be on INS177 23 Operating the Alarm System Premier Series User Guide To Turn CHIME On and Off The system can be set up so that activating opening certain zones will cause the internal sounders to chime This would normally be used on a front door exit button etc PS Zones will only cause the internal sounders to chime if they are selected for chime see page 36 for details on selecting which zones chime Once a zone has been selected for chime the Chime facility can be manually turned on and off as required D The system can also be programmed to automatically turn Chime on and off under certain conditions i e certain times of the day door left open etc If no zones have been programmed for chime then turning Chime on and off will have no effect To turn CHIME On proceed as follows Pr
44. s being used 34 INS177 Premier Series User Guide Premier Series Master User Guide Programming the Alarm System Changing Your User Code Users with access to this option can change their own User codes User codes are unique to each user and can be 4 5 or 6 digits long PS Only the User code that is entered to access the change code menu will be changed Before changing your code it is vital that you memorise or write down the new code you are about to program Failure to remember your code will require an engineer visit to re program a new code for you This may incur a call out charge To change your User code proceed as follows Enter the User code that requires changing D DDC 6 Press E Press Y Press E Press Enter a new 4 5 or 6 digit User code C C DC DC Press to accept the new code Press to exit the menu The display will return to normal INS177 35 Operating the Alarm System Premier Series User Guide Setting up Zones for Chime Users with access to this option will be able to select which zones cause the internal sounders to chime every time they are activated Chime would normally be used on a front door back door exit button etc PS Zones will only cause the internal sounders to chime if Chime is turned on see page 24 for details on turning Chime on and off To setup zones for Chime proceed as follows Enter a valid User code DODDA Press E Pres
45. s on the system to ensure that they operate correctly A walk test can only be performed when the system or area is disarmed 24 Hour zones except Fire and Tampers are disabled during walk test allowing Audible PA buttons Silent PA buttons etc to be tested To perform a walk test proceed as follows Enter a valid User code DODA Press E Press y Press E Press Use keys gt to select an area for walk testing Press to start the walk test Every time zones are activated the keypad will chime Press Gens when finished Press to exit the menu The display will return to normal 38 INS177 Premier Series Master User Guide Programming the Alarm System Enabling Engineer Access If Engineer access either on site or via remote download computer has been programmed as User authorised this option must be used to allow the Engineer access to the programming menu Users with access to this option can authorise Engineer access Nore Engineer access is only permitted for 4 hours after it is enabled after which it will automatically be disabled again To enable Engineer access proceed as follows Enter a valid User code DODDA Press Press Press C until the display looks like this Press Press to enable disable Engineer access Press Press to exit the menu The display will return to normal INS177 39 Programming the Alarm System Premier Series Master User Guide Setting
46. select an area or use the key to search To reset the activity counter press ese Press when finished Press to exit the menu The display will return to normal INS177 29 Operating the Alarm System Premier Series User Guide Sending a Text Message to a Mobile Phone Premier 48 88 168 only If the control panel has a Com2400 or ComGSM fitted the keypad can be used to send a Text message directly to any of the pre programmed mobile phone numbers To send a Text Message proceed as follows Enter a valid User code DDOD Press C until the display looks like this Press Use the keypad to type a message press when finished For details on programming text please refer to page 51 Press 4 gt to select the required telephone number Press when finished The display will return to normal 30 INS177 Premier Series Master User Guide Programming the Alarm System 4 Programming the Alarm System Introduction Advanced operations of the system are carried out using the User Menu i e System Tests Assigning Users etc PS The range of available functions and options will depend on the control panel being used some control panels do not support all of the features and also the type of user on that system Not all options are available to all users If an option cannot be selected it may be that it is not assigned to that user see page 47 for details If no keys are pressed the display will retur
47. ssigned areas In addition Master users can access all User menu options Master users can also change their own User codes and assign new users to the system The Master user will also activate any output programmed as Door Strike 2 Manager Manager users can arm disarm omit zones silence alarms and reset their assigned areas In addition Manager users can access all User menu options except Setup Users Manager users can also change their own User codes 3 Standard Standard users can arm disarm omit zones silence alarms and reset their assigned areas In addition Standard users can access all User menu options except for Setup Users System Tests and Change Timers Standard users can also change their own User codes 4 Local Premier 48 88 168 640 Shunt Premier 24 Local users behave the same way as Standard users However Local users can only arm and disarm areas assigned to their codes from keypads assigned to the same areas Shunt users can omit and reinstate any zone that has been programmed as Shuntable 5 Duress Duress users behave the same way as Standard users However Duress users will activate any outputs programmed as Panic Alarm or Duress whenever their code is entered 6 Arm Only Premier 48 88 168 640 Reset Only Premier 24 Arm Only users can only arm and reset their assigned areas Reset Only users can only disarm following an alarm and then reset rearm the alarm again 7 Door Strike
48. t the menu The display will return to normal INS177 55 Programming the Alarm System Premier Series Master User Guide Calling a Remote PC This option is used to initiate a call to a remote uploading and downloading computer To send a call to a Remote PC proceed as follows Enter a valid User code RARO Press Press Press CS until the display looks like this Press Use keys gt to select a Call Back number i e Call Back number 2 Press to start the call back Press to exit the menu The display will return to normal 56 INS177 Premier Series Master User Guide Programming the Alarm System Altering the Holiday Dates Premier 48 88 168 only This option is used to alter the programmable Holiday Dates These dates can be used to prevent the control timers from operating on certain dates of the year bank holidays etc or to only operate on certain dates reminders To alter Holiday Dates proceed as follows Enter a valid User code DDOD Press Press Press C until the display looks like this Press Use C to Select a Holiday Date from 1 to 8 Press then enter the new date DD DDC CI CG CY Press to accept the new Holiday Date Repeat for other holiday dates Press when finished Press to exit the menu The display will return to normal INS177 57 Programming the Alarm System Premier Series Master User Guide Adjusting Speaker Volumes Premier 48 88 168 only Th
49. the System Time The alarm system has a real time clock that is used to date and time stamp events that are recorded within the system Log Users with access to this option will be able to set the Time on your alarm system To set the System Time proceed as follows Enter a valid User code DODA Press 6 E Press Press O E Press Enter the new time 24 Hour format CH CH CM CMD Press to change between BST and GMT Press Press to exit the menu The display will return to normal 40 INS177 Premier Series Master User Guide Programming the Alarm System Setting the System Date The alarm system has a real time clock that is used to date and time stamp events that are recorded within the system Log Users with access to this option will be able to set the Date on your alarm system To set the System Date proceed as follows Enter a valid User code DODA Press E Press Press Press E Enter the new date OD CD S MOON Press when finished Press to exit the menu The display will return to normal INS177 41 Programming the Alarm System Premier Series Master User Guide Overriding the Control Timers The system has Control Timers that may have been programmed to activate outputs arm areas or lockout users at different times of the day Users with access to this option can turn the control timers on and off manually if required To turn the control timers on
50. to exit the menu The display will return to normal INS177 27 Operating the Alarm System Premier Series User Guide To VIEW Activity Faults If any zones with the Activity attribute have not been activated within a certain time period an activity fault will be displayed at the time of arming Users with access to this function will be able to view the activity faults D To view activity faults on a Premier 24 the View Zone Status menu must be used see page 25 for details The system may have been programmed so that an activity fault will not allow arming If this is the case the system can only be armed once the zone in fault has been activated forced walk test Only zones with the Activity attribute that have not been activated will be shown To view activity faults proceed as follows Enter a valid User code DODA Press until the display looks like this Press Press 4 gt to scroll up and down through the zones Press when finished Press to exit the menu The display will return to normal 28 INS177 Premier Series User Guide Operating the Alarm System To VIEW Activity Counts Users with access to this menu will be able to view the number of times that zones with the Activity attribute have been activated for each area To view activity counts proceed as follows Enter a valid User code DODA Press C until the display looks like this Press Use keys C1 gt to
51. turn After noting the cause of the alarm or fault the system can be reset as described in RESET After an Alarm below D Some action may be required to clear the cause of the alarm or fault in order to successfully reset the panel 20 INS177 Premier Series User Guide Operating the Alarm System To RESET After an Alarm If the display shows SYSTEM ALERTS follow the steps described in To DISPLAY the causes of System Alerts above before attempting to reset USER Reset Once the alarm has been silenced see above the system will need to be reset D If the system has been programmed to be reset by an Engineer pressing will not return the display to normal if this is the case see ENGINEER Reset page 20 for details The system may have been programmed to be reset by Anti code if this is the case see ANTI CODE Reset page 20 for details To reset the alarm proceed as follows Enter a valid User code DODA Press The external strobe will stop the system will chime and the display will return to normal ENGINEER Reset If the system has been programmed to be reset by an Engineer following an alarm activation you will still be able to silence the alarm by entering a valid User code see page 20 for details D The system cannot be armed again until the alarm has been reset To reset the alarm proceed as follows Contact the telephone number on the display if programmed or the teleph
52. turn to normal 32 INS177 Premier Series Master User Guide Programming the Alarm System Event Log Descriptions Log Event Description KSW Active A Keyswitch zone type has been activated zone number RKP MEDICAL A Medical alarm 7 amp 9 has occurred from keypad number RKP FIRE A Fire alarm 4 amp 6 has occurred from keypad number RKP AUD PA An Audible PA alarm 1 amp 3 has occurred from keypad number RKP SIL PA A Silent PA alarm 1 amp 3 has occurred from keypad number DURESS User has entered a Duress Code at a keypad ALARM Active An Intruder alarm signal has been activated for area BELL Active The Bell output has been activated for area REARM LOCK Zone has re armed after causing an alarm CROSS A Verified Cross Zone Alarm has occurred from zone USER User has entered their code AREAS EXIT The Exit mode has been started for area ARMING FAILED A Exit Error Arm Fail has occurred on area AREAS ENTRY The Entry mode has been started for area ARMING SUITE Area Arm Suite was used to arm the system ARMED WITH L F The system has been armed with a Line Fault condition present AREA Armed Area has been armed AREA Disarmed Area has been disarmed PART Armed Area has been Part Armed TIME Armed Area