image

Contents

1. 1 RAM 3 NITEAT LIMI TED CONDENSING SYSTEM INNOVATION SUPER HIGH EFFICIENT AUTOMATIC MODULATING COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER USER S GUIDE CSI 85 B T CSI 85 A T WITH OR WITHOUT BUILT IN TIMER It is the law that all gas appliances are installed by a competent person in accordance with the gas safety installation and use current regulations To the current Gas Safety Installation and Use Regulations B S 5440 2 2000 All CORGI registered installers carry a CORGI I D card and have a registration number Both should be recorded in your boiler log book You can check your installer by calling CORGI direct on 01256 732300 e benchmar The code of practice for the installation commissioning amp servicing of central heating systems Escape of gas Should a gas leak be suspected contact your gas supplier without delay Do NOT search for gas leaks with a naked flame WARNING This appliance must be earthed Do not touch or tamper with this sealed unit or its components 1 INTRODUCTION 1 1 Please carefully read information given in the booklet to help you gain maximum control from your appliance with minimum trouble and cost 1 1 1 Your Ravenheat Condensing Combination Boiler has been designed to supply your Central Heating and Domestic Hot Water directly from one unit When central Heating is operating the circulation will be interrupt
2. 0229 Ravenheat reserves the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet Cod 0017FOG06005 0 03 2005
3. 1 4 3 A RED warning intermittence light on the control panel 8 warns of a high temperature lockout on the overheat thermostat This could occur due to air or poor circulation in the boiler heating circuit This can be reset manually by pressing mains boiler on off switch 1 If lockout should persist leave the appliance shut down and consult your installer service engineer immediately 1 4 4 The CSI 85 condensing boiler is fitted with a con densate outlet which must be connected by the installer to a suitable discharge point as speci fied in the installation manual On no account should this discharge pipe be blocked or modified 2 0 2 1 2 2 3 0 3 1 a2 Fig 1 Mains Central Heating D H W Domestic Summer Winter Hot Water Reset Thermostat Switch Thermostat Central Heating Power Indicator Light Overheat and or Flame failure Indicator light Pressure Gauge Central Heating o gt olor 7 QF BE Wy PRESSURE an RAVENHEAT OPERATING DOMESTIC HOT WATER Select only switch position 1 Open hot water tap After about 3 seconds burner will always operate Temperature of domestic hot water can be varied by adjusting the water flow rate at the tap Domestic thermostat 5 will control maximum temperature leaving the appliance The knob can be set between minimum and maxi mum approximately 35 C to 65 C 95F to 1 49F For maximum temperature of domestic hot wa
4. K 5 1 1 1 SET DAY OF WEEK Press clock button and hold in Press day button to desired day Release both buttons The day of the week will be set 5 1 1 2 SET HOUR Press clock button and hold in Press hour button to desired time Release both buttons The hour will be set 5 1 1 3 SET MINUTE Press clock button and hold in Press minute button to desired time Release both buttons The minute will be set NOTE When setting time holding in the hour minute button this will rapidly advance the display 5 1 2 TO SET PROGRAMMES 5 1 2 1 Press timer button and release to enter into programme mode 5 1 2 2 Programme 1 ON will show in lower left hand corner 5 1 2 3 Press DAY key to select the programme period There are 10 day settings for your choice 1 Mo to Su 2 Mo 3 Tu 4 We 5 Th 6 Fr 7 Sa 8 Su 9 Mo Tu We Th Fr 10 Sa Su You now have a choice of 6 programmes 5 1 2 4 Press hour button to set the required hour on 5 1 2 5 Press minute button to set minute 5 1 2 6 After setting the programme press TIMER key again 1 OFF will appear Repeat procedure 5 1 2 3 through to 5 1 2 5 to set programme 1 OFF TIME Sof a in S RAVENHEAT 6 4 35 on off led reset manual clock minute timer day hour For each programme days off setting must be input the same as the on setting 5 1 2 7 After setting programme 1 ON OFF TIME repeat step 2 1 t
5. ed when domestic hot water is being drawn off This will normally not affect the level of heating CLEARANCES AROUND THE BOILER Above 125mm 5 inches Below 150mm 6 inches Front 450mm 18 inches Sides 5mm 0 2 inches 25mm 1 inch in front when installed in a cupboard PLEASE NOTE Due to the high efficiency and resulting low flue gas exhaust temperature a white plume of condensation vapour cool steam will be emitted from the flue outlet terminal this is quite normal It will be particularly evident during periods of low outdoor temperatures or when the boiler is working at its optimum performance 1 2 1 Minimum clearances are required for safety and maintenance Do not obstruct any purpose made ventilation opening if boiler has been fitted in a compartment Never hang clothes etc over the appliance 1 3 USER CONTROLS See Fig 1 1 3 1 This appliance is designed to operate with the minimum of attention by the user All controls are to be found on the control panel 1 4 OPERATING SAFETY CHECKS TO PROTECT YOUR APPLIANCE 1 4 1 Before lighting the appliance check central heating system pressure 7 is not less than 1 bar gauge If it is below this do not light but consult your installer about refilling your system as you may have a leak in the system 1 4 2 A RED warning light on the control panel 8 warns of a flame failure of the burner This can be reset manually by pressing mains boiler on off switch 1
6. o 2 7 to set programmes 2 through to 6 if required 5 1 2 8 Your timer gives you up to 6 different ONE and 6 different OFF settings per programme period Note you have a choice of 6 ON 6 OFF programmes max 5 1 2 8 1 REVIEW YOUR PROGRAMMES Press the TIMER key to advance display to eache subsequent ON or OFF setting Check days and times displayed To make a change follow instructions under TO SET PROGRAMMES Note on completion of programming operations press the clock button to show current time day and replace the clear tamper proof cover 5 1 2 8 2 MANUAL KEY Press MANUAL key to select ON AUTO OFF mode ON mode is to turn on the timer OFF mode is to turn off the timer AUTO mode is to set the timer to programme mode It will turn on or turn off according to the programmes you set From ON to AUTO mode it will turn on until next OFF programme From OFF to AUTO mode it will turn off until next ON programme 5 1 2 8 3 LED INDICATOR LED light is on when the boiler is operating in heating mode 5 13 TO RESET TIMER Press reset button to reset the timer unit NOTE Once the reset button is pressed the stored time and programme will be cleared to initial state N B When the clock is either programmed on or is on constant the red indicator will illuminate EN Hf MANUFACTURING LIMITED Chartists Way Morley Leeds LS27 9ET Telephone 0113 252 7007 Tfax 0113 238
7. ter leave in maximum position OPERATING HEATING amp HOT WATER TO SET AND ADJUST BUILT IN TIMER MODEL SEE OPPOSITE PAGE 3 Select s switch 2 position Switch on time clock adjust room stat and or thermostatic radiator valves to high settings Burner will operate Temperature output of central heating can be adjusted by central heating thermostat 4 The knob can be set between minimum and maximum approximately 40 C to 85 C 1 40F to 1 85F While the appliance is being used to provide domestic hot water the central heating will not operate When hot water is no longer required the appliance will automatically revert to central hea ting and should not noticeably affect the level of central heating Adjust external controls to required settings NOTE An anti cycling device is fitted to the heating function When the boiler reaches its set maximum temperature it will not operate on heating for about 4 minutes but the domestic hot water func tion will always operate on demand TO SHUT DOWN THE APPLIANCE 3 3 1 For short periods switch to only and turn off all hot taps For long periods switch of the on off switch 1 If the appliance is to be shut down for long periods when there is a risk of freezing then appliance should be drained Similar refilling must be done by a competent per son following approved procedures 4 CLEANING OF APPLIANCE OUTER CASING 4 1 Use a clean damp cloth Do not
8. use any abrasive cleaners end with a dry cloth lightly polish to protect painted surfaces Control panel and fixtures can be wiped with damp cloth and dried Spray polishes must not be used on control panel surfaces or switches Care must be taken in preventing any liquids entering the appliance 4 2 CARE OF YOUR APPLIANCE AND SYSTEM 42 1 Annual servicing of your appliance is required to maintain safety and efficiency of its operation Therefore it is recommended that the appliance is serviced at least once a year and that the who le of the heating system be checked at the same time by a qualified installer If it is Known or suspected that a fault exists on the boiler then it MUST NOT be used until the fault has been corrected by a COMPETENT PERSON It is essential that the instructions in this booklet are strictly followed for safe and economic opera tion of the boiler SERVICING SHOULD BE CARRIED OUT BY A QUALIFIED INSTALLER Ravenheat Manufacturing Ltd Chartists Way Morley Leeds LS27 9ET PROGRAMMABLE TIMECLOCK INSTRUCTIONS FOR USE Your Ravenheat boiler comes complete with optional digital programmer The timeclock is supplied with a cover to prevent accidental loss of programme or children tampering with pre set programmes 5 TO PROGRAMME TIMECLOCK To access programming buttons remove clear cover Press R reset key with a pencil before setting or reprogramming times 5 1 1 TOSET TIME AND DAY OF THE WEE