Algo 8028 Installation User Guide
Contents
1. 8028 SIP Doorphone Installation and User Guide Algo Communication Products Ltd Burnaby BC Canada V5J 5L2 www algosolutions com 241008 01 Document 90 00054B 1 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Important Safety Notice The 8028 SIP Doorphone is designed and tested to comply with EN 60950 1 2006 safety requirements When the Doorphone Controller is connected to wiring that exits the building there is potential risk of lightning induced electrical surges or high voltages from fault conditions To reduce risk outdoor wiring should be protected by Earth grounded conduit whenever possible If outdoor wiring will be connected to the Doorphone Controller then the power supply provided with the Doorphone Controller must first be connected to a properly Earthed mains supply Under no circumstances can the Doorphone Controller be disconnected from Earth ground while connected to outdoor wiring SS E Support Algo is pleased to offer telephone or email support relating to installation issues applications assistance or general product inquiries Algo Communication Products Ltd 4500 Beedie Street Burnaby British Columbia Canada V5J 5L2 support algosolutions com 604 454 3792 sales algosolutions com 604 454 3790 Algo products are warranted against defect in workmanship for a period of 12 months after installation not to exceed 18 months from date of manufacture
2. Normally Closed Input Momentary Open Code 6 Duration 3seconds Cancel if Door Opened Yes No Door Station Input Call Button Normally Open Input X E Securty Settings Max Door Open None X Latch Open Code __ _ i Door Open Alarm Call every 10 minutes v Latch Closed Code Door Station Disconnected None Audio Settings Speaker audio level in 3 dB steps Default 8 Microphone audio level in 3 dB steps Default 7 DSP Noise Reduction e Full Duplex with Noise Reduction e Full Duplex without Noise Reduction Default Ringback Tone Allows audible ringback tone to be played on Door Station speaker until call is answered Enabled Default e Disabled Inbound Call Settings Answer Inbound Call Auto answer or ignore inbound calls Enabled Default e Disabled Answer Tone An optional beep tone can be played at the Door Station when it answers an inbound call Enabled Default e Disabled 13 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Door Relay Settings Momentary Open Code 4 digit DTMF code that can be used to unlock the door for a brief period of time as set by the Relay Time field Leave this field blank to disable this feature Default 6 The duration for which to unlock the door when the Momentary Open Code is entered Cancel if Door Cancels the door unlock i e locks the door again if the Opened door has been opened t
3. Applications for Auxiliary Inputs and Outputs The 8028 architecture and digital link between the Door Station and Controller provides flexible options using the auxiliary inputs and outputs These are some typical applications Cancel Ring When Door Opened In a residential or warehouse installation it is not uncommon for the door to be answered in person before the phone is answered Either Door Station or Control Unit inputs can be configured to cancel ring if the door is opened before a call is answered This requires a normally closed or normally open contact to detect door open Trigger Door Bell from Door Station When the Door Station call button is pressed either or both the Door Station or Control Unit dry contact output can be configured to activate a door bell or auxiliary alerting system in addition to phone ring Trigger Door Station from External Button Event Either the Control Unit or Door Station can accept a dry contact closure to activate the Doorphone as if the call button had been pressed This could be an external doorbell button PIR detector or some other system Cancel Door Open Relay once Door Opened The door opening control can be set for activation using the Open Code up to 30 seconds set by the Relay Time setting to allow sufficient time for entry For security the 8028 Doorphone can be configured to cancel Door Opening once the door is opened to prevent tailgating by unauthorized pe
4. Maximum requested period of time where the 8028 will re register seconds with the SIP server Default setting is 3600 seconds 1 hour Only change if instructed otherwise Keep alive Maintain connection between the 8028 and the SIP Server if the Method 8028 is behind NAT Keep alive Period Period of time where the 8028 will send some information to the seconds SIP Server to keep the connection alive Extension The phone number that the 8028 registers with the SIP Server It will auto answer any inbound calls fAuthID e Authentication ID Used to register the device on the SIP Server SIP password used to register the device on the SIP Server Dialing Extension Phone number to be dialed when the Call button on the door station is pressed 12 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Features Features Audio Settings mau ing B Ring Settings Speaker Volume 8 m Adjust TA Outbound Ring Limit Srings Microphone Volume im 7 Adjust Cancel if Door Opened Yes No DSP Noise Reduction on off Allow Call Button to End Call Enabled Disabled Ringback Tone Enabled Disabled Auxiliary 1 0 Settings Inbound Call Settings Controller Output In Use Ma Answer Inbound Call Enabled Disabled Door Station Output Ca Bua Press Answer Tone Enabled Disabled Door Relay Doar CNA E Door Relay Settings Controller Input Door Sensor
5. Network or Both Format 18 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 NAT NAT Network Address Translation is located between a private network and the Internet When properly configured it allows an 8028 installed on a private network to have access to the outside world such as would be required when using a hosted SIP provider i e a SIP server that is remotely located Algo provides NAT support for both STUN and Asterisk To configure NAT for the server that applies to your application follow these steps STUN Server E sip 1 Enter the STUN Server name ESIP Domain Proxy 10 00 10 or IP address Outbound Proxy optional 2 Set Keep alive Method to STUN Server optional 10 0 0 30 None Registrar optional Register Period seconds 3600 3 Click Save Settings Keep alive Method wone O Double CRLF Keep alive Period 30 seconds Asterisk and other SIP os Servers E SIP Domain Proxy 10 0 0 10 1 Set Keep alive Method to eied Prony Double CRLF STUN Server optional z y Registrar optional 2 Set Keep alive Period to 30 Register Period seconds 3600 3 Click Save Sattings Keep alive Method Onone Double CRLF Keep alive Period 30 seconds El The NAT library sends the binding requests for each port every 30 seconds to ensure NAT mapping is valid all the time ie VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 124
6. input Follow Door Station input Disabled Specifications are subject to change without notice Some features may only be available in specific firmware or hardware releases 26 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Note This page left intentionally blank 207 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ALGO Related Doorphone Products 8028V Tamper Proof SIP Doorphone Same as the model 8028 SIP Doorphone with the exception that the supplied digital door station is a special tamper proof design Suitable for environments where there is a high potential for attempted damage or abuse www algosolutions com 8028V 3226 FXO Trunk Port Doorphone The 3226 emulates a Central Office CO telephone line allowing it to connect directly to a FXO Gateway or telephone system analog trunk port Configurable ring cadence and CLID message Supplied with digital door station with both stainless steel and brass faceplates www algosolutions com 3226 3228 FXS Station Port Doorphone The 3228 emulates an analog telephone set allowing it to connect to an FXS gateway or telephone system analog station port Configurable for hotline or extension dialing Supplied with digital door station with both stainless steel and brass faceplates www algosolutions com 3228 Algo Communication Products Ltd Burnaby BC Canada V5J 5L2 www
7. 5 808299 Auto Provisioning via TFTP Auto provisioning allows installers to pre configure 8028 units prior to installation on a network It is typically used for large deployments If desired 8028 configuration files can be automatically downloaded from a TFTP Trivial File Transfer Protocol server using DHCP Option 66 Option 66 is a term used by some DHCP vendors to describe DHCP code 66 This option code when set supplies a TFTP boot server address to the DHCP client to boot from E DHCP must be enabled in order to use DHCP Option 66 for auto provisioning FTP and HTTP protocols are also supported as well as a static Provisioning Server address instead of DHCP Option 66 One of two files can be uploaded on the TFTP server e generic file algop8028 conf or specific file algom MAC_Address conf If Prov Download Path is defined as Prov_Path by default it s empty and Prov Download Method is set to TFTP the device will download configuration files from these URLs tftp Prov_Server Prov_Path algom MAC_Address conf tftp Prov_Server Prov_Path algop8028 conf MD5 Checksum In addition to the conf file an md5 checksum file must also be uploaded to the TFTP server This checksum file is used to verify that the conf file is transferred correctly without error 20 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 A tool such as can be found at http ww
8. FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected or 4 Consult the dealer or an experienced radio TV technician for help OR VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Table of Contents SUPPOR se iP ene EES ERE he Se GM LE Ee BA GING Eby EES 2 ECC Compliance prir esas ace sdne teh ial af tn a e ea BIG Bana eee Sait be alee 2 Important Safety Notice 0 0 000 eee eee 2 Iniroduction soss sssi emee a s a 0a e ee we HAW Ee ene 4 FE OHUFES ios irl Pe c
9. a locked door to open without retraction of the latch bolt There are two different types of door strikes e Fail Locked or Fail Secure e Fail Unlocked or Fail Safe Fail Locked Fail Secure Electric Strike K 4 24V 0 3A These require power to release and ry remain locked during power failure The door may still normally be opened from the outside with a key or from inside without a key The door control relay is used to apply power to release the door Fail Unlocked Fail Safe Electric Strike 3 F 20V 03A These as well as magnetic locks require Pi PIH power to lock and become unlocked during power failure The door control relay is used to maintain power to the door lock NC and C contacts which is interrupted to release the door Magnetic AE ia locks may require override systems to allow safety exit in the event of fire Door Strike Fail Locked 24 Vdc 0 2 A Typical 8 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Power Supply The Doorphone Controller provides an auxiliary 24 V 0 3 A power supply which is suitable for common types of door strikes If more current or a different voltage is required then the customer must provide a matching power supply for the electric strike or magnetic lock Maximum switching capability of the door control contacts is 1 A 30 V The Door Control relay may also be configured fo
10. ady Power is OK but Ethernet Link not established U Blinks one second on one second off Ethernet Link status OK but IP Address not yet obtained Light on blinks off briefly every two seconds Link and IP Address established successfully Telephone Off Not registered with SIP server Light on blinks off briefly every two seconds Successfully registered with SIP Server ready for use e Blinks one second on one second off error registering with SIP Server check configuration e On steady offhook or ringing state is currently active On steady when door station is connected e Flashing indicates communication errors e On when Door Relay is activated e May flash to indicate when the door is opened if the dry contact is triggered and configured as a door detector P a VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Connection Details Door Control Relay Normally Open 5 Position R vabl a Normally Closed Auxiliary 0 3 A GND jessa 0 3 A 24 V Door Station Jack Center Pair Red amp Door Station RJ12 Telephone Jack Green Middle Pair Dry Contact Input Yellow amp Black Max 1 kQ Outside Pair Dry Contact Output Blue amp White Max 50 mA 30 V Ethernet Jack Connect to LAN with access to RJ45 Telephone Jack SIP compliant Proxy Server Reset Button To return all settings to a factory default press and hold the reset button at startup Continue to hold
11. algosolutions com 28 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299
12. ced applications 1 Connect the power supply to the Power Jack of the Doorphone Controller and plug into an available AC outlet Flush or surface mount the Digital Door Station at desired location and connect a twisted telephone wire pair between the CTRL terminals of the Door Station and the center pair red and green of the supplied Telephone Wiring Jack Polarity is not important Using the short six conductor modular cable connect the Telephone Wiring Jack to the Door Station Jack of the Doorphone Controller Using an Ethernet cable connect the Ethernet Jack of the Doorphone Controller to your LAN Press the Call Button on the Door Station A recorded voice will speak the IP Address of the device Enter this address in a PC web browser in order to open the Web Interface Note The spoken IP address feature will be automatically disabled after a SIP Server is configured in Step 6 below Use the Web Interface to enter the SIP Proxy Server address as well as the user account and password that the 8028 SIP Doorphone will use to register Also enter the target extension that the Doorphone will call Press the Call Button on the Door Station then answer to communicate with the Door Station Press the digit 6 on the phone keypad to activate the door control relay for three seconds if applicable 5 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Applications Typical
13. col DHCP is an IP standard designed to make administration of IP addresses simpler Normally set to On DHCP will automatically configure IP addresses for each 8028 on the network Alternatively if your IT Administrator has assigned one or more static IP addresses set the DHCP setting to Off VLAN Support VLAN Tagging or IEEE 802 1Q allows sharing of a physical network link by multiple independent networks A 12 bit field specifying the VLAN to which the frame belongs A value of 0 means that the frame does not belong to any VLAN The hexadecimal values of 0x000 and OxFFF are reserved All other values may be used as VLAN identifiers allowing up to 4094 VLANs VLAN Priority Priority Code Point PCP a 3 bit field which refers to the IEEE 802 1p priority Values are from O best effort to 7 highest 1 represents the lowest priority DHCP Timeout Length of time following a request from an 8028 to the DHCP seconds server that the 8028 will wait before assuming the server is not available After such time the 8028 will use its default address 192 168 1 111 Default timeout is 60 seconds NTP Server Network Time Protocol server IP address Allows device to automatically set its clock by connecting to an external server 17 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Admin L Admin Device Name doorphone Password eooo Re type Password cece Provisioning Prov Se
14. eiahn dene cots ahaa 2 e a Pee ates eaten ochre 4 Quick Install amp Test 2 2 cc cc cc cc eee eee rere eens 5 Applications 55 6 is seh ORES ea Owe ROSANA OR 6 Typical Applications for Auxiliary Inputs and Outputs 5 6 Door or Gate Control Basics ec cee cere eceeee 8 Door Releases ct e ar E e Se ae eee eas 8 Setup and Installation ccc eee ec cceevcces 10 Programming and Configuration eeeeeee 11 Web Interface Control Panel 0 0 0 0 0c eens 11 NAT aonaran iin Ne a5 Sen 0 Boe ae Sag vele a aie oi Sis fel wie es De ee OS 19 STUN Server Corden ae es ho ERLE yO ech ER ae Se he oe 19 Asterisk and other SIP Servers 0 0 0 ccc cece eens 19 Auto Provisioning via TFTP 2 c ccc cccevece 20 MD5 Checksum 2 40 25 ai e ee Pek BRA ets SS 20 Generating a generic configuration file 0 000 eee eee 21 Generating a specific configuration file 00 00 cece eens 21 Connections and Lights cccc ec eccccscsces 22 Auxiliary Dry Contact Outputs 00 0 0 es 22 Auxiliary Dry Contact Inputs 0 0 00 00 cc eee 22 LED Details coce nae a ee ee ee Woh Lae ie etd 23 Connection Details ese oeni 0c cc eee E a 24 Spe ifications 3 54 04 de naaa a aa E E Awe 25 Related Doorphone Products sssesssesssesoesoeo 28 B VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Introduction Ideal for secure business ent
15. ess of the 8028 press the Call Button on the Door Station The 8028 will speak its IP address if it has not yet been configured with a SIP Server address Alternatively search the network using the 8028 Locator Tool available for download from www algosolutions com 8028locator Web Interface Control Panel The 8028 is programmed using a web interface tool accessed by entering the 8028 IP address into a browser Using this interface you can configure the 8028 network settings and select the desired options These settings survive power cycling and may be programmed in advance prior to site installation m6 i ee VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Configuration Options SIP sip SIP Domain Proxy Outbound Proxy optional J Extension STUN Server optional Auth ID R t ti egistrar optional pene Register Period seconds 3600 Dialing Extension Keep alive Method None Double CRLF Keep alive Period seconds SIP Server Name or IP address Outbound Proxy Outbound proxy is a proxy server that stands between a private optional network and the Internet STUN Server Allow communication between SIP server and 8028 if NAT is optional present see NAT on page 19 Registrar A registrar is a server that accepts REGISTER requests from SIP optional devices Configure Registrar if the SIP Proxy does not accept REGISTER requests Register Period
16. l lockout Door sensor NC Default or NO Call button NC or NO Disabled RJ12 Jack Outside Pair Normally open switch 180 Ohms active Maximum 30 V 50 mA In Use Default Ringing Call button pressed Door unlock Door open requires door sensor Door alarm requires door sensor Door sensor NC Default or NO Follow Controller input Follow Door Station input Disabled 25 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Door Station Power Wiring Signalling Call Button Connections Installation Environmental Auxiliary Input Electrical Auxiliary Input Functions Auxiliary Output Electrical Auxiliary Output Functions i Provided by Controller link Up to 1 000 Ft 300 m 24 AWG single twisted pair to controller Digital link bi directional voice and data Backlit tactile silicon rubber 6 Position terminal strip Controller Aux In Aux Out Flush or surface mounted using supplied plastic bezel Fits two gang electrical box NEMA 3R Rated for outdoor locations Ambient temperature 30 to 60 C Detects dry contact closure 5 V 1 mA sensing current Door sensor NC or NO Call button NC or NO Default Disabled Normally open switch 180 Ohms active Maximum 30 V 50 mA In Use Ringing Call button pressed Default Door gate unlock Door open requires door sensor Door alarm requires door sensor Door sensor NC Default or NO Follow Controller
17. liary devices Maximum switching capacity is 30 V 50 mA Default operations are as follows e Doorphone Controller Output In Use commonly used for camera control Door Station Output Call Button Press commonly used to activate a secondary door bell Other options for Doorphone Controller output include Ring and Call Button Press Other options for Door Station output include In Use and Door Control Auxiliary Dry Contact Inputs Both the Doorphone Controller and Door Station can detect a dry contact closure from auxiliary devices A non capacitive and non inductive low voltage and low current is used to detect contact closure Default operations are as follows e Doorphone Controller input Door Sensor Normally Closed used to detect door open Door Station input Call Button Normally Open used to detect external doorbell switch Options for Doorphone Controller input include Door Sensor Normally Closed Door Sensor Normally Open Manual Door Release Door Control Lockout Call Button Normally Closed and Call Button Normally Open Options for Door Station input include Door Sensor Normally Closed Door Sensor Normally Open Call Button Normally Closed and Call Button Normally Open See Configuration Options on page 12 for more information on setting up auxiliary inputs and outputs 22 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 LED Details On ste
18. ly Open Input Call Button Normally Closed Input Disabled Door Station Input Door Sensor Normally Open Input Door Sensor Normally Closed Input Call Button Normally Open Input Default Call Button Normally Closed Input Disabled A VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Security Settings Max Door Open If the Controller or Door Station input is connected to a physical door sensor and also configured in Door Sensor mode See Auxiliary I O Settings on page 15 then a Door Alarm condition can be triggered if the door remains open for longer than a threshold of 30 sec 60 min 2 min 90 min 15 min 120 min 30 min None Door Open Alarm When a Door Alarm condition is detected based on the Max Door Open time above being exceeded then the 8028 can generate a notification call Call every e 2 min Default 1 hour e 10 min e None 30min Door Station If a wiring fault occurs that breaks communication with the Disconnected Door Station then the 8028 can generate a notification call Call every e 2min 1 hour e 10 min e None Default e 30 min 16 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Network Network VLAN support Enabled Disabled VLAN ID O 4094 VLAN Priority 0 7 DHCP Con Con ity 0 7 Advanced Settings DHCP Timeout seconds 60 NTP Server Dynamic Host Configuration Proto
19. o ensure it cannot be opened a 2nd time Only available if the controller input or door station is configured for Door Sensor mode Allow Call Button If enabled allows visitor to end an active call by pressing the to End Call Call Button Enabled Disabled Default Latch Open Code 1 4 digit DTMF code that can be used to unlock the door indefinitely Leave this field blank to disable this feature Latch Closed Code 1 4 digit DTMF code that will lock the door again when it is latched open Leave this field blank to disable this feature Ring Settings Outbound Ring Limit No ring e Limit to 1 9 rings Default 5 Rings No limit Cancel if Door No Default Opened Yes N VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Auxiliary I O Settings Controller Output n Use Default Follow Controller Input Ring e Follow Station Input Call Button Press Disabled Door Control Door Sensor Door Alarm Door Station Output In Use Door Alarm Ring Follow Controller Input Call Button Press Default Follow Station Input Door Control Disabled Door Sensor Door Relay In Use Door Alarm Ring Follow Controller Input Call Button Press Follow Station Input Door Control Default Disabled Door Sensor Controller Input Door Sensor Normally Open Input Door Sensor Normally Closed Input Default Manual Door Release Input Door Control Lockout Input Call Button Normal
20. r alternate functionality including In Use Ring and Call Button Press il For more information on applications for the 8028 SIP Doorphone please visit www algosolutions com 8028 The 8028 Doorphone firmware may be modified through the web interface and Algo routinely accepts requests for custom firmware for unique applications 9 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Setup and Installation 8028 SIP Doorphone Controller iz elle Ca Door Control Relay see Door Control Section Door Station Jack Reset Button Power Input 24V 0 6A Ethernet Jack Connect to LAN with access to SIP Proxy Server 6 Wire Modular Cable Supplied Telephone Wiring Jack supplied Nj 5 Controller Dry h gt Contact Output Controller Dry Contact Input Twisted pair typical 24AWG gt Max 3000 feet 900m Station Dry Contact Input Station Dry Contact Output 10 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Programming and Configuration Connection to Network and Obtaining IP Address After connecting the 8028 to a network port watch for the PWR light to start winking on and blinking off during initialization The 8028 will then attempt to obtain an IP address from the DHCP server If unsuccessful the 8028 will default to the fixed IP address 192 168 1 111 To find the IP addr
21. rances emergency intercom and residential gates Algo s 8028 SIP Doorphone provides hands free intercom capability entrance security with door unlock control rugged weatherproof design and superior audio performance Fully compatible with SIP industry standards the 8028 SIP Doorphone will work with most hosted or enterprise SIP based servers supporting third party SIP endpoints The 8028 Doorphone includes a Control Unit Door Station and Power Supply The Control Unit and Door Station can be connected with a single twisted pair wire up to 1 000 feet 300 m with the Door Station located outdoors and the Control Unit in a dry indoor location Features e Suitable for commercial or residential applications Door Station connected by a single twisted wire pair e Full duplex capable hands free voice communication at the Door Station e Door control relay contacts and available 24 Vdc 0 3 A strike power e Auxiliary dry contact inputs and outputs from Doorphone Controller and Door Station e Programmable via Web Interface International 110 220 V 50 60 Hz switching power supply e Regulatory CSA UL FCC Class B CE EN60950 1 2006 CB Scheme e VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Quick Install amp Test The 8028 SIP Doorphone requires minimal configuration for a typical installation Programming is only required to enter the SIP account details and for more advan
22. rsonnel Unlock Door Indefinitely until Canceled The door opening control can be set to unlock indefinitely using the Latch Open Code until canceled using the Release Code that locks it again This allows an entrance to be used repeatedly for a period of time without requiring multiple activations of the door control relay rs VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Anti Door Tamper A feature of the 8028 Doorphone is to ring the telephone s with a warning alert in the event a door is ajar due to tampering such as a door blocked open after being legitimately released for a visitor In Use and Ring Either the Control Unit or Door Station can be configured to provide a dry contact output during ring or in use for channel selection typically of third party video monitoring systems ay on VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Door or Gate Control Basics Control contacts are provided from the Doorphone Controller and are typically used for door strike activation or gate control For security the door control relay is located in the Controller to avoid entry by tampering The Door Station dry contact output OUT may be configured for low security gate control requiring a low current dry contact Door Release Door release typically involves energizing or de energizing a door strike which pivots to allow
23. rver Method Prov Static Server Prov Download Method Prov Download Path Advanced Settings Log Level Log Size 1 1000 KB Log Method Log Server IP Name to identify the device in the Algo Network Device Locator Tool Password Password to log into the 8028 web interface Enabled Disabled DHCP Option 66 static TP Orp One Error Low Info Medium Debug High 100 Local Network Both You should change the default password in order to secure the device on the network If you have forgotten your password a soft reset will restore the default setting including all of the device s default settings To do this first disconnect power from the 8028 Doorphone Controller Then press and hold the Reset button on the back of the device and while doing this reconnect the power Continue to hold the Reset button until the LEDs on the front of the controller start to flash See Auto Provisioning via TFTP on page 20 Log Level Amount of information provided in the log files This value should only be changed if advised by Algo Amount of internal memory reserved for recording log file Default is 100 kB Log Method Sets storage location of log file data Default setting is Local Choose Network or Both to send log messages to any Syslog server an option to prevent loss of data during a powerdown Log Server IP P address of Log Server if Log Method is set to
24. the button until all LEDs start to flash Door Station 6 Position Terminal Block Dry Contact Input to Door Station e g Door Contact Doorbell Switch Max 1 kQ Dry Contact Output from Door Station e g Gate Control Max 50 mA 30 V 24 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Specifications Compatibility Configuration Network Address NAT Network Address Translation Speech Codec Physical Controller Power Indicators Network Connection Installation Environmental Door Control Connection Door Control Power Door Control Relay Door Station Connection Door Station Wiring Auxiliary Input Connection Auxiliary Input Electrical Auxiliary Input Functions Auxiliary Output Connection Auxiliary Output Electrical Auxiliary Output Functions SIP Web Interface or TFTP Auto Provisioning DHCP or static IP address STUN Server or Keep Alive Full Duplex Capable G 711 Separate Controller and Door Station AC Mains Adapter 95 230 V 50 60 Hz Included Power Door Station Status In Use Door Unlock RJ45 Jack Shelf or wall mounted Dry indoor location 5 Position terminal strip Available 24 V 300 mA Strike power Relay C NO NC phone keypad activated Maximum 30 V 1 A RJ12 Jack Center Pair 24 AWG Twisted Pair to 1000 Ft 300 m RJ12 Jack Second Pair Detects dry contact closure 24 V 4 mA sensing current Manual door release Door contro
25. w fourmilab ch md5 may be used to generate this file Generating a generic configuration file Connect an 8028 on the network Access the 8028 web interface Configure the 8028 with desired options Click on the Services tab and then on Backup Settings Save the file settings txt Rename file settings txt to algop8028 conf N amp O SON File algop8028 conf can now be uploaded on the TFTP server Si If using a generic configuration file extensions and credentials have to be entered manually once the 8028 has automatically downloaded the configuration file Generating a specific configuration file 1 Follow steps 1 to 5 as listed in the section MD5 Checksum on page 20 2 Rename file settings txt to algom MAC_Address conf e g algom0022EE020009 conf 3 File algom MAC_Address conf can now be uploaded on the TFTP server Ej The specific configuration file will only be downloaded by the 8028 with the MAC address specified in the configuration file name Since all the necessary settings can be included in this file the 8028 will be ready to work immediately after the configuration file is downloaded The MAC address of each 8028 can be found on the back label of the unit 21 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 Connections and Lights Auxiliary Dry Contact Outputs Both the Doorphone Controller and Door Station provide a dry contact output for connection to auxi