NA6830 User Guide
Contents
1. Press the key Set for some time to enter the state of adjusting time and press the key Set to return to the state of displaying temperature In the state of adjusting time the hour part of the LED flashes and you can adjust the hour by using the key a and then press the key Set and the minute part of the LED flashes you can also use the key a and to adjust the value then press the key Set again to exit Pressing the key M in the adjusting process means giving up and exiting but the time will not be saved d How to refrigerate or heat forcibly When displaying current temperature the temperature is between setting temperature temperature difference and setting temperature temperature difference the system may or not refrigerate here you press the key and hold it for 5 seconds the controller will enter the refrigeration state forcibly when in the refrigeration state and stop refrigeration when the temperature is below setting temperature temperature difference the controller will enter the heat state forcibly when in the heat state and stop heating when the temperature is above setting temperature temperature difference v Advanced Operation Press the key M and hold it for 5 seconds and if you have set the password the LED display the PAS to hint you to enter the password you can use the key a and to ent
2. 10 C 50 C humidity lt 85 fs Relay contact capability 8A 250VAC pure resistive load fs Temperature sensor NTC R25 5kQ B 25 50 3470K fs Executive standard Q 320585 XYK 01 NA6830 CTDFA Operating Guide Panel 1 mie tt oa 5s ce set d What s the meaning of the index lights on the panel The function of the LED on the panel is showing below wis Temp Setting In the state of temp setting E Refrigeration Refrigerating re to refrigerate in the state of compressor start delay protection protection Defrosting Dripping or Dripping or the state of compressor start delay protection state of compressor start Dripping or the state of compressor start delay protection protection G i e a d The meaning of the LED display The LED usually shows temperature if it shows SHr it means the temperature sensor is short and OPE means the temperature sensor is open The temperature and the alarm code Axx will show alternately when in the alarm state The code is showing below Open or short showing OPE or SHr Open or short showing OPE or SHr when press the key w If you don t need to use the evaporator sensor you can use the F59 to close the alarm If you have set the probation time F87 the alarm occurs when the accumulative Over probation time ee ee i running time is over probation time and the controller can not work 5 How to set the te
3. NA6830 User Guide gt Main Function and Technique Index Main Function Refrigeration Controlling Refrigeration heat temperature showing temperature controlling refrigeration heat mode can be set compressor start delay protection temperature sensor error alarm it can run periodically with the on off rate and stop which has been set when the temperature sensor is broken Fan Controlling 7 fan running modes fan ahead or delay start delay stop temperature controlling start and stop time controlling start and stop always on always off run or stop when defrosting Defrost Controlling 2 defrost modes electric heat hot gas 3 defrost start mode time alternation accumulative compressor running time real time clock 2 defrost end mode timing controlled by both temperature and time dripping manual defrost defrost sensor error alarm high temperature alarm is forbidden when defrosting External alarm one external alarm input it can be set to 5 modes always open always open locked always closed always closed locked or forbidden Real Time Clock RTC Internal RTC it is still running when power off and it supplies an accurate time used for real time defrost Main Technique Index fs Temperature display range 50 150 C The resolution is 0 1 C 58 302 F The resolution is 0 1 F fs Power supply AC 220V 10 or AC 380V 10 50Hz Refer to the wiring diagram fs Operating environment temperature
4. er the password if the password is correct the LED will display the parameter code use a or w to select the parameter code Pressing the set key can make it to show the value of the parameter after select the parameter here you use or w to set the parameter pressing the key and not release can add or minus rapidly then press the set key to return to the state of showing parameter code after finishing setting Pressing the key M can exit the parameter setting state when display the parameter code pressing the key M means cancel when in the process of setting parameter and the parameter will not be changed Internal parameter code is showing below setting F1 Soete F14 F13 s The setting range is limited by F13 and F14 Control the temperature difference Temperature difference 0 1 20 please refer to the temperature controlling iis the controller will follow F13 Max setting temperature Max setting temperature temperature 830 302 the tule of F14 lt F11 lt F13 forcibly if you find out that one parameter can not be adjusted it F14 Min setting temperature 58 302 is because the parameter is limited by other parameters you must first adjust other parameters aan ae ee ES Evaporator sensor adjustment 20 20 a Adjust the temperature sensor bias F19 Temp sensor adjustment 20 20 Compressor running frequency 100 eee when the temperature when error sensor 1s err
5. hich can be selected F35 OFF Defrost is off 1 Time alternation the controller will start defrost according to the setting alternation time which can be set in Defrost alternation time F31 2 Accumulative compressor running time if compressor accumulative running time reaches the time which set in defrost alternation time F31 the controller starts defrost 3 RTC start the controller turns on defrost according to the actual time for example 6 00 AM 6 points can be set at most F61 F66 in this mode defrost alternation time F31 does nothing The controller has 2 defrost end modes which can be selected F36 0 time control the defrost time can be set by F33 the controller will stop defrosting when it reaches the defrost time 1 controlled by both time and temperature the controller will check the defrost effect through evaporator sensor after starting defrost If the sensor temperature reaches the Defrost end temperature F32 the controller will turn off defrosting if the defrost time is longer than defrost end time F33 the defrosting will be turned off forcibly You can select 2 defrost heat modes F37 0 electric heat the compressor stops and the defrost output is turned on the defrost output controls the electric heater 1 hot gas the compressor and defrost output is turned on the defrost output controls the valve oY Dripping A dripping time can be set F34 For exam
6. igh temp stop when low temp 5 fan is on when the compressor 1s on and times to start and stop when the compressor stops 6 fan always running Enable when F41 1 and 2 Enable when F41 3 and 4 Enable when F41 5 without external alarm always open unlocked always open locked always closed unlocked always closed locked wm fw p 00 00 23 59 OFF 0001 9999 OFF means not using OFF OFF means no password 0000 means clearing password C Centigrade F Fahrenheit The controller will stop if the accumulative time is over and show the probation time alarm code A99 OFF means no probation time This function can attract all relays in turn and please don t use it when the controller is running po End SP Exit Basic Operating Principle lt Temperature controlling The controller has 2 temperature controlling mode Refrigeration and Heat F29 Temperature controlling point is controlled by setting temperature F11 or press the set key for some time to set and temperature difference F12 In refrigeration mode the controller begins to refrigerate when the temperature of the temperature sensor is over setting temperature temperature difference and it stops refrigerating when the temperature is under setting temperature temperature difference In heat mode the controller begins to heat when the temperature of the temperature senso
7. mperature A22 Evaporator sensor error Press the key set for at least 2 seconds then enter the state of temperature setting here the LED displays the setting temperature then using a key or w key can change the parameter the key adds 0 1 C the key minuses 0 1 C press and hold it over 0 5 seconds can add or minus rapidly After setting press set again then exit the state of parameter setting The setting temp range is limited by the parameters F13 and F14 please refer to the advanced operation Pressing the key M in the setting process means cancel and exit but the setting value will not be saved d How to defrost manually When in the state of displaying current temperature press the key and hold it at least 5 seconds then the controller enters the defrosting state In defrosting state press the key and hold it at least 5 seconds again this can finish the defrosting forcibly d How to read the temperature of the evaporator sensor When displaying current temperature press w key Controller will display evaporator temperature Loose w key then return to current temperature Notice that if you press the key and hold it for 5 seconds the controller will enter or exit the defrosting state forcibly 9 How to look over and adjust the real clock time Press the key Set to enter the state of displaying time when in the state of displaying temperature
8. or Temperature error Defrosting F35 E37 F42 F43 F45 F46 F47 F50 RTC A o O F80 rj OO System setting F87 Testing Compressor controlling mode temp controlling mode Defrost end temperature Defrost start mode COOL HEAT COOL COOL refrigeration mode HEAT Heat mode Defrost ana on time eee a oo a a iio OFF 1 l 3 OFF defrost is off 1 time alternation start alternation start the alternation is compressor accumulative running time 3 RTC start 2 time 0 only controlled by time meee a ee ee 1 controlled by both time and temp Defrost heat mode Oorl 0 O electric heat 1 hot gas OFF fan off when defrosting Fan state when defrosting OFF or ON ore ON fiot when deoe Fan ahead delay start time Fan delay stop time Fan start temperature OFF 1 l 6 ee 0 1 50 Fan start time Fan stop time External alarm mode Whether use the evaporator sensor error alarm Set the RTC time 6 Real Time defrost time Enable when F35 3 Password Temperature unit time reset Start Probation time Reserved OFF fan off 1 follow the compressor state fan delay start delay stop 2 follow the compressor state fan ahead start delay stop 3 fan is controlled by the evaporator temp start when low temp stop when high temp 4 fan is controlled by the evaporator temp start when h
9. ple set the dripping water with 5 minutes after finishing defrosting in 5 minutes compressor doesn t run in this state Defrost indicator light will flash But in two conditions the controller can t enter the dripping state one 1s finishing the defrosting manually and the other is defrosting temperature sensor s error oY About fan controlling Fan has 7 operation modes F41 OFF fan is off but it may start when defrosting rest with F38 1 follow the compressor state fan starts lingeringly after compressor starts F42 fan stops lingeringly after compressor stops F43 2 follow the compressor state fan starts ahead before compressor starts F42 fan stops lingeringly after compressor stops F43 3 fan is controlled by the evaporator temperature start when low temperature stop when high temperature F44 F45 the fan starts when the evaporator temperature is below F44 and stop when the evaporator temperature is over F44 F45 4 fan is controlled by the evaporator temperature start when high temperature stop when low temperature F44 F45 the fan starts when the evaporator temperature is over F44 and stop when the evaporator temperature is below F44 F45 5 fan is on when the compressor is on and times to start and stop when the compressor is off the on off time is set by F46 and F47 in other words on for F46 minutes and off for F47 minutes 6 fan always running but it stops when external alarm occu
10. r is under setting temperature temperature difference and it stops heating when the temperature is over setting temperature temperature difference x Compressor delay when power on The compressor delay when power on is set by F20 for example 3 minutes the controller does not start the compressor within 3 minutes after power on x Compressor delay time The compressor delay time is set by F21 for example 3 minutes The controller contains a compressor halt calculagraph and it begins to time when compressor stops the program first check the calculagraph before booting the compressor next time the program will immediately boot the compressor if the calculagraph reach 3 minutes if the calculagraph doesn t reach 3 minutes it will boot again when the calculagraph reaches 3 minutes Thus you can ensure that the boot alternation is over 3 minutes after halt so it can prevent to breaking the compressor as a result of frequent boot oY Compressor running timly when temperature sensor is error When the temperature sensor is error in order to avoid that the goods in the coldroom destroy you can make the compressor continues to run with a setting on off rate It is set by F22 and F23 for example F22 20 F23 50 that when the temperature sensor is error the cycle is 50 minutes and the compressor stops for 40 minutes and runs for 10 minutes oY Auto defrosting principle The controller has 3 defrost start modes w
11. rs In addition it may stop when defrosting rest with F38 In spite of which mode fan state is only rested with F38 when defrosting In spite of which mode fan stops when external alarm occurs oY External alarm The controller can connect a switching value as external alarm source Pin 4 5 when the external alarm occurs the controller stops displays the alarm code A11 and generates alarm output External alarm signal has 5 modes F50 without external alarm always open unlocked always open locked always closed unlocked always closed locked Always open means in normal state external alarm signal is open if closed the controller will give an alarm Always closed is on the contrary Locked means that when external alarm signal becomes normal the controller is still in the alarm state and it needs to press any key to resume SY Probation time A probation time can be set F87 the controller can add up the running time after power is on if the accumulative running time is over the probation time the controller will stop and display the alarm code A99 if you want to eliminate the limit of probation time set the F87 to OFF also you can use the F86 to clear the accumulative running time and you can try to use it again The parameter F85 can be used to examine the accumulative running time of the controller hour oY Password In order to prevent irrespective persons from changing the parame
12. ters you can set a password F80 and if you have set a password the controller will hint you to enter the password after you press the key M for 5 seconds you must enter the correct password and then you can set the parameters If you don t need the password you can set F80 to OFF Notice that you must remember the password and if you forget the password you can not enter the set state KR WN a Wiring Diagram 8A 250V AC T1 Temperature Sensor Plum T2 Evaporator Sensor 1 External Alarm Signal Notice 1 Please read the guide carefully before using and set the parameter accurately 2 Please place the temperature sensor at the place of air return of the air cooler and the defrosting sensor above the air return pipe of the air cooler 3 The evaporator sensor must be fixed on the air return pipe of the evaporator and if you don t use the evaporator sensor please set the F59 to NO or the controller will generate alarm Please use the temperature sensors which are supplied by our company 5 The RTC power of the controller is supplies by super capacitance and the RTC can run for 3 days when power cut if the power cut time is over 3 days you may adjust the RTC again gt
Download Pdf Manuals
Related Search
Related Contents
Manual de usuario: Registro de actividades SNCyT 2014 改訂版取扱説明書ダウンロード USER MANUAL Bedienungsanleitung / Mode d'emploi 10,1"-Tablet-PC User Manual V7 CAT5e UTP Network Cable 3 (RJ45 m/m) blue 3m jumbo tcs 52 anw PV Module Installation Manual Harman Kardon AVR 145 User's Manual 資料4-2 平成22年度医療機器自主回収一覧(PDF:693KB) Copyright © All rights reserved.