1. 1 NS OC EN MODE O NL UGHTING UH Mode Lighting UK Limited The Maltings 63 High Street Ware Hertfordshire SG12 9AD UNITED KINGDOM Telephone 44 0 1920 462121 Facsimile 44 0 1920 466881 e mail sales modelighting com website www scenestyle co uk DS135 HH SceneStyie4 SceneStyle4 User Guide The Stylish way to Control your Lighting Troubleshooting Symptom SoWia Check that there is a working load wired in series with circuit 1 Check that the lamp on circuit one has not blown Check that the mains supply is on to the SceneStyle4 by checking the MCB or fuse in your consumer unit Check that the load on circuit 1 is no more than 500W total There is an overload short circuit or open circuit on that circuit If the circuit has a load connected check the circuit loading and check that there is not a blown bulb on that circuit If the circuit is open circuit the LED will continue to flash once the open circuit is detected but once a scene is selected will not flash again Unit does nothing One of the buttons 1 2 3 or 4 is flashing red orange The circuit was overloaded for too long and the auto shutdown feature has been activated Select a scene the SceneStyle will then attempt to re start that circuit If the problem persists check the loading and check for short circuits or open circuits on that circuit A bulb blew on one circuit I have replaced the bulb but now
2. Low Voltage Transformers Cct To Neutral d 1 NotforInductive or Magnetic loads 2 E Circuits 1 and 2 50 500 Watts K cet Circuits 3 and 4 50 250 Watts cet Lour 3 Total load not to exceed 1000 Watts 4 L out X Circuit 1 MUST be connected X 1 b OUT Live in MUST be externally fused OUT or protected at 6A maximum a 1 R1 As Spare use as wire amp parkf R2 i RTN R1 to R4 are Remote inputs RTN OUT Please refer to user guide for OUT full installation instructions and C H T P R3 detailed loading charts Ra i3 REN This unit MUST be earthed RIN MODE LIGHTING UK LIMITED The Maltings 63 High Street Ware Hertfordshire SG12 9AD United Kingdom Tel 44 0 1920 462121 Fax 44 0 1920 466881 www scenestyle co uk Example of a Remote Switch b Remote 2 way Switches c Switches wired in parallel or push buttons d 3 way Switching e g stairs landing sales modelighting com Page 5 Fitting the Front Fascia Plate The fascia plate must be fitted prior to switching on the mains power Normally the fitting of the fascia would be delayed until after the wall has been painted and other non clean building tasks have been completed To fit the fascia align the left hand side first clipping it onto the side of the plate Ensure that all of the buttons are able to fit through the holes You may need to wiggle them slightly to ensure that they do not get trapped behind the fascia Firmly press the top right corner and then the botto
3. age Page Page CON N O Page Page Page Page Page OO O O CO Page Page 11 Page 12 Page 13 Page 14 Page 15 Page 12 Page 14 Page 15 Page 16 Page 16 Page 1 Introduction SceneStyle4 is a scene setting self contained dimmer for up to four circuits also known as channels or zones in four scenes or mood settings The four circuits can be set to any combination of levels in each of the four scenes The four buttons do not have to specifically relate to the four circuits individually There are also ON and OFF scenes A scene is a pre programmed set of different brightness levels for a combination of circuits that may be recalled at any time by pressing one of the scene selection buttons Scenes are used to create different lighting moods for the area being illuminated All of the circuits which are currently illuminated or any individual channel on its own may be raised or lowered made brighter or dimmer at any time without affecting the programmed scenes Important Safety Notes A WARNING Isolate turn off the mains power at the main consumer unit fuse box before commencing installation or performing any maintenance including changing blown lamps A SceneStyle4 is designed to control incandescent filament lamps at Mains Voltage or Low Voltage when fed from a suitable Electronic Transformer To avoid hazard or pos sible damage do not use with inductive fluorescent wire wound Transforme
4. bre Erat al Cott Press te togetus exclude fn circuit T i i FE Y SHOE a Circuit button LED changes Button 1 0 seconds ut eae 7 Button 2 2 seconds E Button 3 4 seconds Es Button 4 seconds Release the T circuit button T To edit another scene hold down the bution fer the scene you require for 5 seconds Slap 2 Then follow either option A B C or D abere v To exit programming mode hold dyan the Bashing blue scene bution for 5 seconds Page 8 www scenestyle co uk sales modelighting com Page 9
5. button to program your colour choice for a bright colour to indicate the selected scene LEDs show the seven available dim colours and off 3 Press a button to program your backlight colour Factory Default Colours During this Step the bottom right hand button resets the LEDs to the factory default colours which are ON scene Green OFF scene Red For scenes 1 to 4 a bright blue LED indicates the scene is currently selected whilst other LEDs are lit in dim blue Blown Bulbs Short Circuits and Shut Down The SceneStyle4 contains advanced fault detection and automatic shut down circuitry If a circuit is overloaded i e if too many bulbs are connected to that circuit short cir cuited or open circuited then it will automatically shut down This does not affect the other circuits connected to the SceneStyle unit If the fault condition was only momentary for example if a GU10 lamp had blown then SceneStyle will detect this state and will automatically try to restart the circuit If the fault condition prevents the circuit from automatically restarting the LED for the button corresponding to that circuit will flash alternately red and orange until another scene is selected SceneStyle4 will attempt to restart the shutdown circuit each time a scene is selected using either the plate scene buttons or the infra red handset If the SceneStyle 4 has not been able to restart the circuit then the flashing LED indi cation of
6. e4 Contents Introduction For the installer For every day use Operation How To Select a Pre Programmed Scene ee How To Raise Lower levels of channels currently illuminated How To Raise Lower the level of a single channel Programming Scene PrO an NING ewesecevetsce setecsceeoutetceeeconsesetecsesgecseue Setting Button LED ColourS sesxeiscsawetutexiuepevkss visas Vira akut Connecting Two Way Switches or External Switch Inputs Blown Bulbs Short Circuits and Automatic Shut Down How To Reset To Factory Default Settings Advanced Setup Infrared Remote Control seeeeeeeeennen nnn Entering Advanced Setup Mode J eene nnn Remote Input Options Menu Tee Group 1 Two way switching ssssssee enn hh hhhhhnnnnnnn ahhh nnns Group 2 Scene selection between pre determined scenes Group 3 Scene selection between pre determined scene and previously SelBcteu SCENO arpe re ratas uda re kedqadus3dudnteVado tao kia ao dd Qc A A RR C Group 4 Scene selection of an individual scene ooo Group 5 Impulse Operation pas 14ssaratau read dE FREE REPERERRRD aux ReEERUK PETER FEE LEUE What Is Impulse Operation e enn n WEOUDICSIOOUING vesdvidiideavtUne des pEs uada ME EIUS ines sales modelighting com Page 1 Page 2 Page 4 P
7. emote inputs mains rated switches by following these steps Step 1 Enter advanced setup mode U Hold down A and V buttons together and whilst they are held press sequence 2 1 2 1 Step 2 Setup configuration of remote inputs Buttons 1 and 2 illuminate green Press Button 1 to select Remote Input Options Menu Other buttons are reserved for future enhanced features Step 3 Choose which remote input to set up 1 4 Buttons 1 2 3 and 4 will be illuminated in red Press the button corresponding to the remote input that you want to set up i e button 1 selects input number 1 Once selected the chosen button will flash red whilst you carry out steps 4 and 5 If you wish to return to step 2 press OFF e To return all remote inputs to default settings hold button 1 4 simultaneously untill all LED s flash red approximately 5 seconds then release all buttons Step 4 Choose the type of switch that is connected to the remote input Buttons 1 2 3 and 4 are illuminated blue to indicate available options Button NU DEN Switch Type Momentary action retractive push button Rocker alternate action default setting Rocker fixed action Volt free contact trigger on contact closure Volt free contact trigger on contact opening see Page 14 for description of switch types Select the required switch type 1 2 3 4 or 5 If you wish to return to step 2 press OFF e Step 5 Choose re
8. ircuit 1 must always be connected Circuit 1 has a maximum load of 500W and a minimum load of 50W The total load connected to the SceneStyle4 must not exceed 1000W Minimum Load Minimum Load Mains Lighting LV Electronic Transformers Circuit Maximum Load TIP If the load connected to Circuit 1 drops below the minimum level shown in the table above then all circuits will be affected For example if the lamp s connected to Circuit 1 blows and the resulting load is less than 50W or 100W if using elec tronic transformers then all of the other circuits may no longer function cor rectly Therefore it is recommended that you make Circuit 1 the circuit to which you connect the largest number of lamps Note The minimum load figures quoted are for Mode Lighting UK Ltd electronic transformers SceneStyle4 will operate with other electronic transformers however if they have a high input capacitance a common problem with low quality goods then the minimum load may increase A The SceneStyle4 dimmer is suitable for 12v halogen lamps using only electronic transformers and not wire wound or toroidal Suitable electronic low voltage lighting transformers are manufactured by Mode Lighting UK Ltd Please contact your SceneStyle4 stockist regarding the correct product for your installation You may connect 240V GLS and GU10 lamps to the SceneStyle4 dimmer A SceneStyle4 circuits will shutdown if short circuited open circuited or over
9. l power up to the OFF e scene To select a pre programmed scene Press one of the numbered Scene buttons on the left or press either the ON xt or OFF e button on the right The scene will be recalled at the fade time that has been programmed and the button will illuminate brightly to show which scene has been selected By default the pre programmed Scenes are configured as follows Factory Default Settings circuits at 90 2 second fade circuits at 70 2 second fade circuits at 50 2 second fade circuits at 30 2 second fade circuits at 100 Full On instant action no fade circuits at 0 Off 2 second fade Double pressing a button wil slower fade snap to the scene i e on instant action rather than a See the section below on Scene Programming for details on how to set your own lighting levels for each scene To raise or lower the level of all circuits that are currently illuminated Press and hold either the A raise or V lower button To raise or lower the level of a single circuit at any time gt Press and hold one of the numbered buttons 1 4 on the left to select the circuit you wish to alter Within 5 seconds and whilst still holding the numbered button press and hold either A or V to raise and lower the circuit brightness ES Release both buttons when the desired level has been reached Scene Programming The levels of each circuit may be independently set in each sce
10. loaded This is indicated by buttons 1 2 3 or 4 flashing red orange A The front fascia plate will become warm during operation This is normal A SceneStyle4 does not require a Neutral and may be used to replace normal light switches or rotary dimmers sales modelighting com Page 3 Wiring Each of the circuits of the SceneStyle4 dimmer replaces a normal light switch or rotary dimmer Circuit 1 must always be used and has a maximum load of 500W and a mini mum load of 50W You do not have to use all four circuits however you will still have four available scenes together with ON and OFF e available soiscenedtyle4 sce 02 04 4 Circuit Trailing Edge Dimmer with InfraRed 230V 10 50Hz 4 0A max Single phase only tc max 70 C SY tamax 25 C Live In Vie ce amp O e Cct Electronic Low Voltage Transformers Cct a 1 Not for Inductive or Magnetic loads 2 E Circuits 1 and2 100 500 Watts E Live Out Circuit 4 Live Out Circuit 3 x Circuits 3 and4 50 250 Watts x Live Output to swith a ama Total load not to exceed 1000 Watts p our A Live Output to Switch 2 X Circuit 1 MUST be connected X Switched return from Switched return from Live in MUST be externally fused l Bur d uem External Switch 2 Exiemal Switch 7 R1 or protected at 6A maximum R2 E t _ Live Output to Switch 4 3 Spare use as wire park Switched return from Live Output to Switch RTN R1 to R4 are Remote i
11. m right corner of the fascia until it clicks into place Check that all of the buttons are freely protruding through the holes in the fascia Removing the Front Fascia Plate A fascia plate may be removed by inserting a 4mm flat head screwdriver under the tab that protrudes from the bottom right corner of the plate and performing a quarter turn twisting action Be ready to restrain the fascia as it detaches from the false plate to avoid damage in dropping it TIP ADVANCED FEATURE Circuits may be excluded from a scene so that when that scene is recalled the excluded circuit stays at its current level For example in your living room if the circuit was connected to a standard lamp you could control it using the SceneStyle without affecting the levels of the ceiling wall lights in the room however the OFF scene would still be able to control all lights By default all circuits are included in all scenes Page 6 WWWwW scenestyle co uk Setting LED Colours The LEDs that illuminate the buttons on the SceneStyle4 have two states 1 They may be set to one of seven colours when they are brightly lit indicating that a scene or circuit has been selected 2 They may be set to be either off or illuminated with a dim colour when they are indicating that a button is not selected i e a backlit colour 1 Hold down the A and V buttons for 5 seconds LEDs show the seven available bright colours 2 Press a
12. mote input function Select a two digit operating function by pressing two buttons to choose the group number and the second to choose the selection within that group from the table on the following page Press 1 indicates the group Press 2 indicates the selection from within that group continued on p 14 Page 12 WWW sScenestyle co uk Connecting Two Way Switches or External Switch Inputs The SceneStyle4 has four pairs of terminals to enable up to four external mains rated switches to be connected These switches may be configured to perform one of a number of different functions using the advanced set up menu see Pages 12 14 By default they are configured to switch their respective circuit On or Off The remote inputs are mains live and therefore all switches or volt free relay contacts and the cable to them must be mains rated Switches used may be push buttons or retractive switches rocker switches or volt free contacts The Live outputs to the switch terminals are internally connected to the Live In terminal Therefore it is important to ensure that the permanent live feed is connected to the Live In terminal and not to the Live Out terminal see diagram below LIGHTING UH HSceneStyle4 8 02 04 4 Circuit Trailing Edge Dimmer with InfraRed 230V 10 50Hz 4 0A max Single phase only tc max 70 C IME C vy ta max 25 C CA Live In LIN For Incandescent lamps and v Cct Electronic
13. ne A scene does not have to contain all of the circuits in an illuminated state Each scene has a fade time which is the amount of time it will take to transition from the current light levels to the levels that have been programmed into the scene Available fade times are O instant change 2 4 or 8 seconds By default scenes will fade over 2 seconds apart from the ON X scene which is set to snap on by sales modelighting com Page 7 Scene Programming Scene Programming bution 1 4 ort ore io ad rS Cons ES gt Binp 1 Selected Scena LED flashes blue SE g Channels that are included in the Scene are iluminaled green mai Host ore wxciudec from the Scene are Buried wd Choose thus functi n ses A B Gi ci Malo UTE All Teatunes are oplional default setlinqs dimi uiid if you d nor eda mier bariga l B Set Scene C Overall Scene D Include Exclude a l a A Set Circuk Levels Fade Time Level Raise or Lower Circuits Hold dewn tha circuit you want In Y T T nclude of exclude E i To sed the level of each To change he Y circuit hold the circus i GAl brghinwesss Whilst thas bution Butin i4 and ws e e vel of me eras a tor 2 agoonia ios ROME i heki end Step 2 hired x within 5 Scion Une tha A or V eese beara A butions on ther lilia brighinees rel a amp ace e eater Se eee rni ett i gwm ko mise or required The bogh est buon meiles phar Fear ies Fade
14. nputs RTN OUT Please refer to user guide for OUT Switched return M M 7 R3 full pud instructions and RA V f external switch 4 etailed loading charts t External Switch 3 RTN This unit MUST be earthed RIN NB The cable connected to the Live In terminal must be capable of supplying the total current for all four circuits 4A maximum and must be protected by an external fuse or miniature circuit breaker MCB rated at 6A maximum Terminals marked have no internal connection You may use them as a terminal to park additional live feeds from lighting circuits other than Circuit 1 Hscenestyle4 sce o2 o4 4 Circuit Trailing Edge Dimmer with InfraRed 230V 10 5OHz 4 0A max Single phase only tc max 70 C V tamax 25 C le C M Spare Live from Live In Lin For Incandescent lamps and AP v Cct Electronic Low Voltage Transformers Cet Ceiling Hose rdi 1 Not for Inductive or Magnetic loads 2 gd To Neutral Circuits 1 and2 100 500 Watts To Neutral Spare Live ce Circuits 3 and4 50 250 Watts cet 7 7 7 Spare Live from Lour 3 Total load not to exceed 1000 Watts 4 L our Ceiling Hose To Neutral 6 Circuit 1 MUST be connected 6 OUT Live in MUST be externally fused OUT TO Neutral or protected at 6A maximum a D R1 Spare use as wire park R2 Y RTN R1 to R4 are Remote inputs RTN TEE OUT Please refer to user guide fo
15. ore automatic holiday mode beings This is done by using a combination of buttons 1 2 3 and 4 to indicate the required time The delay time is calculated by adding the values represented by buttons 1 2 3 and 4 together as shown in the table below Press each of the buttons to toggle them on green or off not illuminated to add or exclude their value from the time For example to delay the start of holiday mode by 5 hours buttons 1 and 4 should be illuminated Time until Button 1 1 hours Button 2 2 hours Button 3 3 hours Button 4 4 hours V indicates that the button is toggled to the On state To activate Holiday Mode U Hold down the ON lt and OFF e buttons for 5 seconds until all LEDs illuminate green Release the buttons All LEDs will flash green and the LED showing the current scene will be illuminated red As the SceneStyle simulates occupance the red LED will change from scene to scene automatically The sequence of scenes is as in the table below Example actual time if Scene Holiday Mode is delayed automatically to begin at 6 00pm recalled L1 Start Time 6 00pm o 2 Start Time 30 minutes 6 30pm a DENN 3 Start Time 1 hour 30 minutes 7 30pm LC 2 Step Offset from Start Time 4 Start Time 3 hours 30 minutes 9 30pm EE ee 5 Start Time 6 hours 30 minutes 12 00pm a 3j 6 Start Time 12 hours 30 minutes 6 30pm a 7 Start Time 13 ho
16. r OUT Ws R3 full installation instructions and RA V D s n a detailed loading charts RTN This unit MUST be earthed os If the loading of the SceneStyle4 is close to maximum 1000W then the SceneStyle4 and the fascia plate will get warm this is normal To keep the temperature rise to a minimum we advise that if the SceneStyle4 is installed in a wall with some form of insulation e g fibreglass that you remove the insulation from around the back box to allow air movement Page 4 www scenestyle co uk Remote Input Options Menu Input types allowed Push button Retractive Rocker switch alternate action Rocker switch fixed action Volt free Group 1 Two way switching ES Input switches its respective circuit Default setting i2 Input switches all circuits 3 Input switches Circuits 1 and 2 only 4 Input switches Circuits 1 and 3 only 5 Input switches Circuits 1 and 4 only 16 Input switches Circuits 2 and 3 only 7 Input switches Circuits 2 and 4 only 8 Input switches Circuits 2 3 and 4 only Group 2 Scene selection between pre determined scenes 1 E Input alternately switches between e Scene and 3 scene 2 Input alternately switches between e Scene and Scene 1 3 Input alternately switches between e Scene and Scene 2 4 Input alternately switches between e Scene and Scene 3 EA Input alternately switches between e Scene and Scene 4 6 Input alternately switches be
17. r or motor loads A SceneStyle4 must be installed by a qualified electrician or other competent person Installation should be in accordance with the National Wiring Regulations or other applicable Regulations Compliance with the EC EMC or Low Voltage Directives may be invalidated if not used or installed to the published specification A SceneStyle4 is for installation to 230V and 240V single phase mains supplies only The cable connected to the Live Input terminal must be capable of supplying the total current of all four circuits 4A maximum SceneStyle4 must be protected by an external circuit breaker or fuse rated at 6A maximum p SceneStyle4 is a Class 1 product This unit must be Earthed A SceneStyle4 must be installed in a suitable UK double gang backbox compliant to BS4662 or BS5733 We recommend that a 47mm depth backbox is used A SceneStyle4 complies with EN60669 1 EN60669 2 1 EN55105 and EN61547 For indoor use only at temperatures between O C and 40 C A Do not operate without the front fascia plate correctly fitted Page 2 WWW sSscenestyle co uk Holiday Mode SceneStyle4 can help deter would be burglars by simulating occupancy of your house by switching lights on and off automatically To Enable Holiday Mode Hold the ONG and OFF e buttons down together for 5 seconds until the LEDs on those buttons illuminate green ES Release the buttons t Enter the delay that you require bef
18. ssed but not when it is released Rocker switch alternate action With alternate action a rocker switch on the remote input will activate whenever the rocker is switched to a different position as it would with a standard domestic two way switching arrangement Rocker switch fixed action With fixed action option a rocker switch on the remote input will always perform the same action when the switch is opened and a different action each time the switch is closed For example If a last man out rocker switch is connected to two SceneStyles both set to switch between the ONG and OFF scene from a fixed action rocker the OFF scene will always be recalled on both SceneStyles when the switch is opened and the ON scene will always be recalled when the switch is closed However with an alternate action rocker if one of the SceneStyles is in the ON X scene and the other is in the OFF scene and the rocker switch is activated both SceneStyles will switch to the opposite scene Volt free contact trigger on contact closure With this switch type the remote input will activate whenever the RTN terminal on the SceneStyle becomes live Volt free contact trigger on contact opening With this switch type the remote input will activate whenever live is removed from the RTN terminal of the SceneStyle Page 14 WWW sSscenestyle co uk Maximum and Minimum Loads You do not have to use all four circuits however C
19. that circuit no longer works Configurable input only works Check that the live in and live out connections for when the lights are on circuit 1 are the correct way round You have not met the minimum load requirements for the circuits or a lamp has blown which has reduced the load The lights flash flicker at high Use higher wattage lamp you can dim them to levels only reduce the brightness if required or replace any blown lamps Remember to isolate the SceneStyle4 before changing any lamps This is normal especially when the unit is heavily The front fascia plate is warm loaded i e 1kW or close to 1kW of lamps are connected To Reset To Factory Default Level Settings Light Levels The default scene settings may be restored at any time by simultaneously holding down buttons 1 2 3 and 4 together until all of the button LEDs flash blue after approx 5 seconds then releasing all the buttons LED Colours The LED colours and remote input settings are not reset when the factory default scene levels are reset To reset the LED colours see the previous section on page 11 Setting Button LED colours Remote Switches To reset the function of the remote inputs see the section on advanced set up on page 12 Please visit our dedicated website for further information regarding the SceneStyle range at www scenestyle co uk For Electronic Transformers see www modelighting com Page 16 www scenestyle co uk mm SceneStyl
20. the fault will occur once only per detected fault but the SceneStyle 4 will attempt to restart the shutdown channel each time a scene is selected Either from one of the six scene buttons on the plate or by the infra red handset The fault detection indication can be recalled to display any faults that have not been rectified To do this hold down buttons 1 amp 4 until all LEDs flash red orange When both buttons are released any outstanding faults will be indicated by the LED corre sponding to the circuit alternately flashing red orange sales modelighting com Page 11 Infrared Remote Control The infrared remote control allows selection of the four scenes and the ON x or OFF e scenes The raise and lower buttons perform a master raise lower function on all of the circuits in a scene Any circuits that are programmed to be off i e a level of zero in a particular scene will not be altered by the A andV buttons Further IR codes for use with learning remotes such as the Philips Pronto are available from www scenestyle co uk These allow facilities such as individual circuit control Scene 1 On Scene 2 Off Scene 3 Raise Scene 4 Lower Page 10 WWW sSscenestyle co uk Operation Scene selection buttons when pressed or Circuit selection LL ON scene button d ae OFF scene button buttons for a i Raise raise lower OG r when held Lower By default the SceneStyle4 wil
21. tween Scene and Scene 3 7 Input alternately switches between x Scene and Scene 4 8 Input alternately switches between Scene 1 and Scene 4 Group 3 Scene selection between pre determined scene and previously selected scene 1 Input alternatively switches between e Scene and previous Scene v 2 Input alternatively switches between tx Scene and previous Scene v Vv 3 Input alternatively switches Scene 1 and previously selected Scene v Vv 4 Input alternatively switches Scene 2 and previously selected Scene Vv 5 Input alternatively switches Scene 3 and previously selected Scene v 6 Input alternatively switches Scene 4 and previously selected Scene v Vv Group 4 Scene selection of an individual scene 1 Input selects Scene 2 Input selects xx Scene 3 Input selects Scene 1 4 Input selects Scene 2 5 Input selects Scene 3 6 Input selects Scene 4 Group 5 Impulse Operation operation respective circuit only operation all circuits operation Circuits 1 and 2 only operation Circuits 1 and 3 only operation Circuits 1 and 4 only operation Circuits 2 and 3 only operation Circuits 2 and 4 only operation Circuits 2 3 and 4 only Group 6 Special Options d Last man out any scene to e e to xx sales modelighting com Page 13 Entering Advanced Setup Mode Advanced Mode allows you to configure special options for the r
22. urs 8 Start Time 15 hours To exit holiday mode press any button sales modelighting com Page 15 COntinued from page 12 The LED s are extinguished after the first press and the first digit entered will be illuminated purple After the second button has been pressed if a valid selection is made you will be returned to step 3 Page 12 If an invalid selection is made i e a code that does not exist or an incompatible switch type all LEDs will flash red until you press another button at which point you will be returned to step 2 Page 12 Any incorrect settings will not be stored so the last good state will be used instead To leave advanced setup mode press OFF e twice Note Note Some combinations of function and switch type are not allowed eg Impulse operation with a volt free contact The table shows the input types that are allowed for each option What is Impulse Operation Impulse operation uses one push button input to select between on off and raising or lowering of lighting levels Alternate short pushes of the button toggle between on and off Holding the button down will raise or lower the level of the circuit s When the circuit is switched on it will return to the last on level that it was set at Description of Switch Types Momentary action push button Retractive switch With this type of switch the remote input will activate whenever the push button retractive switch is pre