Home
Pregnancy Test Operating instructions 0123
Contents
1. Pregnancy Test Operating Instructions C E 0123 This product is composed of the glass fiber strips of monoclonal antibody against human chorionic gonadotropin hCG anti mouse IgG solid cellulose nitrate membrane and the bonders of absorptive colloidal gold monoclonal antibody against hCG It adopts the principles of double antibody sandwich method and immunochromatography to test the hCG in the urine Intended Use used for early diagnosis of pregnancy Contents each pouch contains one test strip and one desiccant CTT T T M Absorbent Pad Test Line Control Line Test Procedure Before the use please prepare a timer and urine cup 1 The Pregnancy test is formulated for use with fresh urine specimens Urine cup should be used to collect specimens 2 Remove the strip from the foil wrapper 3 Immerse the strip into the urine with the arrow end pointing toward the urine Do not cover the urine over the MAX maximum line You may take the strip out after a minimum of 15 seconds in the urine and lay the strip flatly on a non absorptive clean surface 4 Read the result within 10 minutes 5 Discard the test device after single use Interpretation of Results Negative If only one pink line appears in the control area you can assume that you are not pregnant Positive If two pink lines appear both in the control area and test area you can assume that you are pregnant Inconclusive If there is no distinct pink purple colored band vis
2. ible both in the TEST area and CONTROL area the test is inconclusive It is recommended that in this case the test should be repeated If the problem persists contact your local distributor Warnings amp Precautions For in vitro diagnostic use only 1 As with all diagnostic tests a definitive diagnostic should not be based on the results of a single test but should only be made by the physician after all clinical and lab findings have been evaluated Read directions for use carefully before performing this test Pay attention to the position of the C and T line Do not use the kit beyond the labeled expiry date Do not reuse the test devices Do not use if pouch is damaged or opened Do not touch the membrane area Once open the pouch the test device should be used immediately Prolonged exposure to ambient humidity will cause product deterioration N NOOR amp Distributed in the UK by Home Health UK Ltd Unit 11 Peerglow Industrial Estate Olds Approach Watford Hertfordshire WD18 9SR Website http www homehealth uk com Manufacturer Nantong Egens Biotechnology Co Ltd Block A No 15 Building No 1692 Xinghu Avenue Nantong Economy amp Technology Development Zone Jiangsu Province P R China
Download Pdf Manuals
Related Search
Related Contents
Exhibitor Information and Registration Bilder - Robland 付表1 一般管理における運用管理の実施項目例 Les Dames de fer du Liberia 1-2. About the UFM-14DADA/18DADA - FOR Pronomic PH12/15 Aktiv/Passivbox Manuel d`instructions Model UU-2X4 USB Extender Copyright © All rights reserved.
Failed to retrieve file