1. 753mm Terminal block Fig 1 90mm Also minimum 65mm for overhang ji or shelf f50mmmin 125mmF Fig 2 Electrical Connection This heater must be used on an A C supply only and the voltage marked on the heater must correspond to the supply voltage To comply with the I E E Wiring Regulations the appliance must be earthed the supply circuit must be adequate for the input of the appliance and the circuit protected by a suitable fuse This appliance has a loading of 500 Watts If the heater is to be connected to a fixed electricity supply a Suitable termination must be provided adjacent to the final position of the appliance In this instance such a termination can be a double pole switch with a contact separation of at least 3mm in all poles The SCH5 if converted to floor standing by adding feet must also be fitted with a rewireable UK 3 pin plug incorporating a 13 amp fuse The 13 amp fuse must be approved by ASTA to BS1362 The wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Safety For your safety this appliance is fitted with a thermal cut out In the event that the product overheats the cut out switches the heater off automatically To bring the heater back in to operation remove the cause of overheating then switch off the electrical supply to the heater for a few minutes When the heater has cooled sufficien
2. Electromagnetic Compatibility These standards cover the requirements of the EEC Directives 73 23 and 89 336 Glen Dimplex UK Ltd UK customer helpline 8 00AM 6 00PM Mon Fri 8 30AM 1 00PM Sat Millbrook House Grange Drive Customer Services Tel 0870 727 0101 Hedge End Fax 0870 727 0102 Southampton E mail customer services glendimplex com SO30 2DF Republic of Ireland Tel 01 8424833 c Glen Dimplex UK Limited All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex UK Limited
3. X Dimplex Convector Heater Model SCH5 Installation and Operating Instructions BEAB ah Issue 2 September 2004 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE Do not cover the appliance Always ensure that the air inlet grille beneath the heater is free from obstructions Curtains soft furnishings and materials should not be allowed to come in contact with the appliance as this could cause overheating and a fire risk This appliance must not be used in a bathroom Do not use this heater in the immediate surroundings of a bath shower or swimming pool This heater must not be located immediately below a fixed socket outlet This appliance must be earthed Do not operate the heater without the cover attached General The Dimplex SCH5 Convector heater is primarily designed for wall mounting Feet are however available Part no CH9101 and enable the heater to be converted to floor standing units if required The heater is designed either for individual operation or if wall mounted may be connected together in multiples with a connector kit Part no CH0471 As supplied the Dimplex SCH5 convector heater does not have any controls Your electrical supplier will be able to advise on timeswitch or thermostatic controls which would be suitable where multiple installations are involved Dimensions 65 ee 127 Cig H Fixing hole centres
4. tly switch the heater on Wall mounting singly Please refer to Fig 1 and 2 The front cover is secured with two screws Slotted fixing holes Heater must be horizontal with the supply cable at the right hand end Recommended screw size No 8 Wall mounting multiple Please refer to Fig 1 and 2 Freestanding Mains cable entry can be into either of the end heaters of a When not wall mounted the heater must be fitted with feet multiple installation Part no CH9101 Here ae Or here The current rating of any multiple installation must not exceed 13 Amps The flexible cable supplied with the heater is suitable for a current rating of 6 Amps only For every connection between adjacent heaters a connector kit Part no CH0471 is required It is also necessary to remove the knockouts from butting end plates to take the screwed bush and link wires i The cable entry must always be at the eal cover removal and mounting heights are as for single pattoniHaht hand cad ofthe heater eaters Connector kit CH0471 Connector kit cable entry A connector kit comprises A Two lengths of heat resistant wire brown B One earth bonding lead green C Six wire securing clips D One threaded bush and nut E One auxiliary Earth terminal consisting of a screw a bonding washer a coil washer and two nuts F One Terminal block and mounting pad G One length of wire pink and flag crimp Detail of a
5. uxiliary Earth terminal E van a mm k IL a i f T pmm H yf 1mm Cleaning To maintain the external appearance of the heater it need only be wiped over occasionally with a dry duster A damp cloth may be used but the heater should be off and completely cold Do not use abrasive cleaning powders or polish Periodically any dust which may have accumulated on the element and terminals should be removed To gain access first disconnect the appliance from the electricity supply and then remove the front cover After sales service Your Dimplex convector heater is guaranteed for one year from the date of purchase We undertake to repair or exchange free of charge within this period any part found to be defective due to a manufacturing fault Should you require after sales service please get in touch with the supplier from whom you purchased the product or contact Dimplex customer service Please do not initially return a faulty product or part of a product to us as this may result in transit damage and or a delay in providing service If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or service agent Let us know your difficulty quoting the details shown on the rating label we will then take the appropriate action CE This product complies with the European Safety Standard EN60335 2 30 and European Standards EN55014 EN60555 2 and EN60555 3 for