1. lt u _ Communication Cable D Sub9 Pin D Sub9 Pin Male Female RS 232C 10 2 Place the data logger on the communication port TR 50C with the face side down Z CAUTION Do not use the TR 50C in wet condition Light entering the unit during the communication may result in a communication error Please make sure that the Thermo Recorder is placed properly on the TR 50C EX TR 52 T A Standard Communication Cable to your computer 3 Open T amp D Recorder for Windows TR 5 7xU on your computer and make settings such as Start Recording and other Recording Conditions gt For more details see T amp D Recorder for Windows TR 5 7xU User s Manual or the HELP menu of the software 11 Specifications E Communication Port for TR 50C Communication method Optical communication method Between TR 50C and TR 51A TR 52 RTR 51 52 53 RVR 52 Serial Communication RS 232C Between TR 50C and Computer Communication Speed 2400bps 160 Seconds when data capacity is full Dimensions H92 x W66 x D29mm Excluding Protrusions Weight Approx 60g only for main TR 50C unit Operating Environment Temperature 10 to 40 C Humidity less than 90 RH No affect from acid alkaline materials or organic solvents Avoid strong light during communication Avoid moisture Accessories Included Communication Cable x 1 RS 232C D Sub 9Pin
2. Cable Length 1 5m Standard Software x 1 set User s Manual and Warranty x 1 set E Specifications of Standard Software T amp D Recorder for Windows TR 5 7xU Compatible OS Microsoft Windows 98SE Me Microsoft Windows 2000 Xp Number of Display channels 8 channels simultaneously displayed Data display Graph Table Data list Specification of range zoom in out Maximum minimum values average values recording intervals and number of record data Maximum minimum values average values Data Output Graph printing List printing and text file output Control Function 12 Programming start time Setting recording intervals Setting mode Optional Sensors List E Temperature Sensors for TR 52 Possible Measurement Range 60 to 155 C Sensor Temperatur Durability 70 to 180 C Water Resistant Ability Splash Proof Sensor and Cable Measurement Accuracy Average 0 3 C 20 to 80 C Average 0 5 C 40 to 20 C 80 to 110 C Average 1 0 C 60 to 40 C 110 to 155 C Materials Thermistor Stainless Pipe SUS316 Teflon Compaction Tube Teflon Resin FEP Shielded TR 5106 Teflon Shielded Sensor All dimensions in mm Cable Length 0 6m Thermal Constant Time 600 In the Air Approx 15 Sec yl M o F D e H In agitated water Approx 2 Sec rd ik TR 5101 Teflon Shielded Sensor Cable Length 45mm Thermal Constant Time g b In the
3. may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING This equipment has been verified to comply with the limits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment You are cautioned that changes or modi cations not expressly approved by party resp
4. Air Approx 15 Sec J a In agitated water Approx 2 Sec TR 5220 Stainless Protection Sensor Cable Length 2m 4l Thermal Constant Time q H In the Air Approx 36 Sec Q In agitated water Approx 7 Sec 185 30 2000 a 13 TR 5320 Stainless Protection Sensor All dimensions in mm Cable Length 2m Thermal Constant Time v In the Air Approx 12 Sec LI i In agitated water Approx 2 Sec f g TR 5420 Stainless Protection Sensor Cable Length 2m y m Thermal Constant Time rr V1 Oo In the Air Approx 12 Sec In agitated water Approx 2 Sec E Sensor Extension Cable TR 2C30 Sensor Extension Cable All dimensions in mm Cable Length 3m she Splash Resistant ce ve CAUTION Use only one extension cable per temperature sensor When using the extension cable there will be a 0 3 C at normal temperature and at 50 a gap of 0 5 C may occur 14 E Wall Attachment TR 05K1 Wall Attachment 30 70 Pod 67 All dimensions in mm Material Aluminum Neoprene E Maintenance TR 00P1 Maintenance Set Double sided adhesive tape aa ff Silica gel Lock Screw Rubber packing Contents Rubber packing x 1 Silica gel x 1 Double sided adhesive tape x 1 Lock screw x 2 TR 05K2 Wall Attachment 18 65 p ET wi of jy All dimensions in mm Material ABS Resin
5. on the unit nor expose the unit to a strong impact Doing so may cause damage to the unit Communication is not possible with this unit in direct sun light Avoid strong light during communication o 20b Table of Contents Introduction Notices about this User s Manual 1 FCC Compliance Statement for American Users 2 Safety Precautions and Instructions 3 Getting Ready Outline of the Product 7 Part Names and Functions 8 Basic Usage Communication via your Computer 9 Communication Procedure 10 Other Specifications 12 Optional Sensors List 13 Provisions for Free Repair 16 Warranty TR 50C penne nn nnn anne nnn nn nnn nnn n ee ennee ee Back Cover Outline of the Product E Outline TR 50C is a communication port to download data measured and recorded by Thermo Recorder TR 5 Series or RTR 5 Series Units to your computer The collected data can be downloaded to your computer via the included software T amp D Recorder for Windows TR 5 7xU where you can use the software to create colorf
6. to download all of the recorded data from TR 5 Series and RTR 5 Series Units as well as carry out the following functions in managing the data Display 8 channels of data in colorful graphs Control Display ON OFF for each channel Zoom in and out of graph data Display data for two points on graph and differences in measurements for those points Select calculation range and calculate highest lowest and average values for that range Select and set precise recording start date and time Change channel names Change channel order Merge channels Delete channels Change graph background color and line color and width Create data tables Print out graphs and tables Create and export data in Text file format Save data files NOTE Comunication Port TR 50C can be used handle both TR 5 Series Units or RTR 5 Series Units but only the software that comes with the TR 50C T amp D Recorder for Windows TR 5 7xU can be used to control the use of the port Communication Procedure E Set Up Procedure 1 Connect the serial port of your computer and the main unit through the standard communication cable Connect the cable to a serial port which has the following mark lool SSF LULL N CAUTION Make sure to fully insert the connector to secure a proper connection Connecting to a wrong port will result in communication failure TR 50C a Connect t Computer
7. Corporation of any mistakes errors or unclarities in this manual Microsoft Windows and WindowsNT are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company Teflon is a registered trademark of the Dupont Corporation and of the Mitsui Dupont Fluro chemical Corporation The Warranty that comes with this Manual can not under any cicumstance be reissued so please keep it in a safe place The Manual itself can be downloaded from our Home Page http www tandd com Published by T amp D Corporation 1st Edition April 2002 Copyright 1998 2005 T amp D Corporation All rights reserved E FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harm ful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions
8. TR 00P2 Low Temperature Battery Set Lithium battery Tube ER3VM Contents Lithium battery x 1 Tube x 1 Maintenance Set x 1 15 Provisions for Free Repair 16 1 If the unit does not work properly despite the fact that the customer used it properly and in line with the User s Manual the unit shall be repaired free of charge through the agent which sold the unit 2 If the customer requests free repair because of trouble within the warranty period bring or send the unit along with the warranty to the dealer A service charge may be added if a repairperson must be sent out to the place of use for repair 3 If you have moved after purchasing or the product was received as a gift or there are some difficulties contacting the shop from which you purchased the unit please contact us directly for service 4 Free repair is not available in the following cases even though it is within the warranty period 1 Trouble or damage was caused by careless operation natural disaster fire public pollution or use of a power source other than specified 2 If repair adjustment disassembly or modification of the unit has been carried out by a person other than a T amp D authorized engineer 3 Trouble or damage was caused by transportation movement or dropping of the unit after purchase 4 Failure to submit the Warranty or failure to fill in all items required in the Warranty 5 This Warranty cannot be reissued This Warr
9. Thermo Recorder COMMUNICATION PORT TR 50C User s Manual Carefully read and fully understand instructions before using this unit Copyright 1998 2002 T amp D CORPORATION All rights reserved 2005 04 16004054200 E Notices about this User s Manual Carefully read and fully understand these instructions before using this unit All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Please follow the safety precautions carefully We cannot guarantee nor are we responsible for safty if this product is usd in any manner other than was intended T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair of the attached warranty T amp D Corporation accepts no responsibility for any results or effects from using this User s Manual On screen messages in this manual may vary slightly from the actual messages Figures and illustrations in this manual may be slightly simplified and may differ from the actual product Specifications design and other contents are subject to change without notice Please notify the shop where you purchased this product or T amp D
10. anty only promises customers free repair within the period and condi tions clarified in this Warranty Therefore the customer s legal rights will not be limited by this Warranty For further information on repair and others service questions after the termination of the warranty period contact your dealer E Contact Information T amp D corporation 5652 169 Sasaga Matsumoto NAGANO 399 0033 JAPAN Phone 81 263 27 2131 Facsimile 81 263 26 4281 E Mail overseas tandd co jp E Homepage T amp D Online Visit our English Homepage for further details and information about our company products up coming events software and supports http Awww tandd com 17
11. onsible for compliance could void your authority to operate the equipment Safety Precautions and Instructions In an attempt to ensure safe operation of our products and to protect them from the possibility of damage throughout this User s Manual the following symbols are used to indicate important warnings cautions and notices Please be sure to read under stand and follow the contents of all such warnings Explanation of Warning Symbols These entries are actions that absolutely under no circumstance should be taken The taking of DANGER i such an action may cause serious personal physi cal damage or death These entries are actions that if taken may lead N caution i to physical injury or damage to persons or things E Explanation of Picture Symbols This symbol denotes an important warning or caution Inside or A near the symbol will appear another symbol giving details EX A stands for INFLAMMABLE This symbol denotes a forbidden action Inside or near the S symbol will appear another symbol giving details EX stands for DO NOT TAKE APART This symbol denotes an action that you must take Inside or near the symbol will appear another symbol giving details EX stands for BE SURE TO FOLLOW Es A DANGER Do not take apart repair or modify the main unit It may cause fire electrocution or damage Please ask the shop where you bought the product or T amp D to ca
12. rry out any repairs If any smoke or strange smells are emitted from the unit immediately cease using it Continued use may cause fire electrocution or damage If water or a foreign body enters the case immediately cease using it Continued use may cause fire electrocution or damage This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the malfunction of our unit Please be fully aware of this before using our product Do not connect standard communication cable to a tele phone line This can cause fire or other trouble in personal computers gt P gt ER O Es ACAUTION Do not put your fingers or foreign matter into the commu nication port Use these units under conditions with an ambient tempera ture of 10 to 40 C and humidity of 90 RH or less Do not use or store the unit in places such as listed below In places exposed to splashing water In the direct sun light or in excessively hot and humid places In excessively smoky dusty or steamy places In areas exposed to harmful chemicals or gases In areas exposed to strong magnetic fields Do not drop the unit place heavy weight
13. ul graphs tables export text files as well manage files and control printing E Contents of Package Thermo Recorder TR 50C x 1 Communication Cable RS 232C D Sub 9Pin Cable Length 1 5m x 1 a for TU TRTRU TRSIA TREE SS TAD tonreemnon lt E Standard Software User s Manual and Warranty T amp D Recorder for Windows Software User s Manual TR 5 7xU x 1 set x1 Part Names and Functions E Front View Thermo Recorder COMMUNICATION PORT TR 50C CQ rele Optical Communication Port lt v E Top View ITM lel T T Communication Cable Connection Jack Seea a Communication via your Computer Connect TR 50C to your computer and communication can take place between your computer and the data logger The following settings can be also made by using the software T amp D Recorder for Windows TR 5 7xU gt For more details about these functions and operation of the software see T amp D Recorder for Windows TR 5 7xU User s Manual or the HELP menu of the software Recording Start Stop Start and Stop the Recording via the Software Set Recording Conditions Recording Conditions such as Record Starting Date Interval Recording Mode and Temperature Unit of Display C F can be set or changed easily via your computer Download Recorded Data With our exclusive software T amp D Recorder for Windows TR 5 7xU it is possible