immersion heaters - installation and operating instructions.
Contents
1. 2010 any asbestos Service Service Fax Email 0844 8711535 0844 8711528 heatraesadiaservice heateam co uk 36005868_issue_04
2. Thermostat temperature range 10 to 60 C 3 0 INSTALLATION 3 1 The immersion heater should only be installed in a domestic copper cylinder to BS 1566 or copper hot water storage combination unit to BS 3198 32 An asbestos free gasket is supplied with the immersion heater to be fitted against the element head Use of any sealant on the gasket is not recommended 33 The immersion heater screws into a 2 4 BSP thread boss 11 and 14 immersion heaters should be installed horizontally Immersion heaters longer than 14 should be installed vertically When selecting an immersion heater please ensure there is minimum gap of 15 mm between the end of the element and the inside surface of the tank 3 4 Please refer to diagrams overleaf for assembly of the earth post neutral terminal and cable clamp 4 0 ELECTRICAL 4 1 his appliance must be earthed It is suitable for a c supply only Electrical insulation must be carried out by a competent electrician and be in accordance with the latest E E regulations 4 2 Ensure the electrical supply is switched off before making any connection to the unit 4 3 This immersion heater must be wired with heat resistant flexible cord with a minimum cross sectional area of 1 5 mm 4 4 This immersion heater must be wired through a double pole isolating switch with a contact separation of at least 3mm in both poles 4 5 The cable grip should be secured using only the screw provided see overleaf 4 6 This
3. IMMERSION HEATERS INSTALLATION AND OPERATING INSTRUCTIONS These instructions cover Copper Superloy 800 and Superloy 825 immersion heaters Supplied by Heatrae Sadia and Pullin 1 0 INTRODUCTION 1 1 IMPORTANT POINTS Thankyou for purchasing a Heatrae Sadia immersion heater This unit is manufactured in the UK to the highest standards and has been designed to meet all the latest relevant safety specifications The immersion heater must be installed and commissioned by a competent person Please read and understand these instructions before installing the immersion heater Following Installation amp Commissioning the operation of the unit should be explained to the user and these instructions left with them for future reference The immersion heater is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the immersion heater 1 2 PACK CONTENTS Immersion heater thermostat Installation and Operating Instructions brass nut 1 spring washer 2 flat washer 1 cup washer 1 M4 x 8mm screw 1 saddle washer 1 cable grip 1 self tapping screw 15mm 2 self tapping screw 12mm 1 2 0 TECHNICAL SPECIFICATION Rating 3 0kW 240V 2 8kW 230V
4. ew M4x8mm Spring Saddle washer washer Reset pin GREEN YELLOW Thermostat Wiring assembly Connect live BROWN to thermostat Connect earth earth post Connect neutral BLUE Cable clamp assembly i SLS 12mm Screws A 5mm x2 Screw Thermostat Link wire Secure cable clamp firmly NOTE BEAB approval only applies when the components are assembled correctly as shown in the diagrams above 7 0 SPARE PARTS Gasket 2 pack of 10 RDT 7 thermostat horizontal RDT 11 thermostat horizontal RDT 11 thermostat vertical RDT 18 thermostat vertical Gasket screw kit 8 0 GUARANTEE The immersion hea 95611565 95980034 95980035 95980041 95980036 95611009 er is guaranteed against faulty materials and manufacture for a period of 2 years from date of purchase The immersion heater is not guaranteed against damage by frost and excessive scale build up 9 0 ENVIRONMENTAL INFORMATION This product is manufactured from many recyclable materials At the end of its useful life it should be disposed of at a Local Authority Recycling Centre in order to realise the full environmental benefits It does not contain any substances harmful to health it does not contain HEATRAE SADIA The quality name in water heating Heatrae Sadia Heating Hurricane Way Norwich NR6 6EA www heatraesadia com PART OF BDR THERMEA
5. immersion heater must only be installed into a system where it will always be immersed in water such as a cistern fed tank or cylinder 4 7 The installer must check that the tank is full of water before the immersion heater is switched on 5 0 COMMISSIONING 5 1 The immersion heater is supplied with an RDT thermostat factory set to 60 C This is a combined control thermostat range 10 C to 60 C and over temperature thermal cut out 5 2 To maintain safety any replacement thermostat must be of the same type 6 0 USER INSTRUCTIONS 6 1 OVER TEMPERATURE CUT OUT Should excessive water temperature occur the integral over temperature cut out will operate to prevent the water storage cylinder from boiling The over temperature cut out should only be re set by a competent person 6 2 When the cut out operates the re set pin see diagram overleaf will be pushed upwards so that it is level or slightly proud of the of the thermostat cover 6 3 The water storage cylinder must be allowed to cool and the reason for the operation investigated and rectified before re setting the cut out 6 4 The over temperature cut out is re set by lightly pushing the re set pin into the cover until it reaches a stop Earth post assembly Brass nut __ Spring washer Flat washer Earth _ cable Cup ae washer Earth post Neutral terminal assembly Neutral Neutral cable N terminal Scr