Home

ChannelPlus H21XL Series 2 User Operating Instructions

image

Contents

1. buttons to adjust R amp S Press ENTER HEADINGS ZONES OR CHANNELS TIME AND DATE v Press the green SET button Press the green SET button gt Press ENTER NONE L O ONATED A nd Hot Water should you require either the Zone or Channel options then please follow and the flowchart opposite select SET DEFAULTS SAMPLE DISPLAYS SET WATER SET HEATING SET HOLIDAY MODE Si a a aaa aE CLOCK OPTIONS a a SEE HEADINGS General Information RESETTING THE CHANNELPLUS H21XL SERIES 2 Electronic equipment can in some circumstances be affected by electrical interference If the display becomes frozen or scrambled or if you wish to revert back to the default settings please use the following procedure RESET PROCEDURE P P LEASE NOTE Using this procedure wi rogramme settings the time setting restore the ChannelPlus to the original factory will remain correct Lower the front flap of the unit On the r hand Channel press the ADVANCE Enter and SELECT Blue buttons together then elease and the programmer will return he preset factory settings lt BOOST RESET SELECT 11 What is a programmer an explantion for householders Programmers allow you to set On and Off time periods Some models switch the central heating and domestic hot water on a
2. Channel will be continuously ON Press SELECT again Programme goes from ON to OFF Channel will be continuously OFF Press SELECT again Programme goes from OFF to AUTO Programme will return to normal ON and OFF times It may not be possible to programme heating and hot water independently on certain systems Setting the Programme Times The programme times have been preset as shown in the chart below DEFAULT TIME SETTINGS AM PM 1st ON 1st OFF 2ndON 2ndOFF 3rd ON 3rd OFF 6 30AM 8 30AM 12 00PM 12 00PM 4 30PM 10 30PM If any changes are required to the programme times please Open cover complete the operation as described in the flowchart left V Press the green SET button Select Set ON OFF times gt SAMPLE DISPLAYS Select the required channel setting a a nan nn nian NY e U SET HEATING SET HOLIDAY MODE AY SET DEFAULTS cis v Repeat process for KS the 2nd and 3rd e time settings V Press the green SET button Ny SETTING WATER WEDNESDAYS Close cover Use the and buttons to adjust required on time Select the day to set SETTING WATER e Enter the required on and off times Press the green OFF 08 30 OFF 12 00 OFF 22 30 PERIOD 1 PERIOD 2 PERIOD 3 SET button ADJUSTING SETTINGS When carrying out any alterations to the programmed times and set
3. HORSTMANN ChannelPlus H21XL Series 2 User Operating Instructions Two Channel Central Heating and Hot Water Programmer The ChannelPlus family of electronic programmers offer a range of advanced features coupled with simplified menu driven programming all designed to help save energy The Horstmann ChannelPlus H21XL series 2 is designed to give independent time control over heating and hot water on a 24 hour programme Each channel offers up to 3 programmed On Off operations per day For day to day operation each channel has a manual 1 or 2 hour boost button as well as an advance button to bring forward the next programmed operation The back lit display automatic clock and menu driven programming are all features designed to make the operation of the ChannelPlus H21XL as simple as possible to use All series 2 ChannelPlus programmers are direct replacements for earlier ChannelPlus models The ChannelPlus H21XL Series 2 Programmer The simple instructions contained in this user guide are designed to help with the programming and operation of the unit Most of the following instructions require the front flap to be lowered Please replace the flap when normal operation is required PRODUCT OVERVIEW DETAIL SHOWN WITH THE FLAP LOWERED 00 00 O ON AU RWN 000 0 0 6 Current time of day Day of week and date Channel Heading Current Channel programme Next On Off time Channe
4. SET DEFAULTS SAMPLE DISPLAYS NY SET WATER SET HEATING SET HOLIDAY MODE i n enia aaaea ag Use the and Press ENTER buttons to adjust SET DEFAULTS J 24 HRS OR AM PM Press the green SET button Press the green SET button TIME AND DATE Ci NY CLOCK OPTIONS HEADINGS Press ENTER CLOCK OPTIONS AM PM BATTERY General Information The programmer is fitted with a non rechargeable non serviceable long life battery which will maintain the clock and programmed time settings with the mains supply disconnected THIS RESERVE SH THE UNIT During power in OULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF erruptions the display will be blank SERVICE AND REPAIR This programme r is NOT user serviceable Please do not dismantle the unit In the unlikely event of a fault developing please refer to the RESETTING THE CHANNELPLUS H21XL section on the right If this fails to resolve the problem please contact a local heating engineer or a qualified electrici an JO Adjusting Channel Headings The programmer has been preset to display the channel heading Open cover g i as Heating a Use the Y Use the and 1 buttons to adjust Press ENTER gt HEATING WATER SET DEFAULTS Press the green SEY itt Bene v Use the and
5. 2009 end period Press ENTER e gt Close cover Display when holiday mode is set Press the green z SET button v THURS 16 SEPT Press the green SET button Adjusting Default Settings The ChannelPlus H21XL Series 2 has a number of default settings which are normally installed These settings are designed to reduce the need for user intervention upon installation of the programmer However it is possible to customise the user display by following the procedures in the following pages The factory default normally installed are illustrated below Time and Date Clock Options Time and calendar Time displayed in Channel heading set to are factory set 24hr clock format standard installation i e Hot Water and Heating YoY V 10 42 ewan 22 42 ifm WATER HTG WATER HTG Auto Alida Auto Allday On until On until On until On until 11 40 22 30 11 40 22 30 The programmer has 24 hour Heating Water been set with the current or Zones time and date during AM PM Channels manufacture No alteration should be required to the time and date However if any modification is required please refer to the flowchart on page 9 Adjusting Time and Date The ChannelPlus H21XL Series 2 programmer has been set with the current time and date during manufacture No alteration should be required to the time and date however if any modific
6. ation is required please refer to the flowchart below PLEASE NOTE Any alteration to the current time or date will cancel any Holiday programme set It will also Open tover cause any Boost or Advance operations to be cancelled V Press the green SET button gt Use the and buttons to select SET DEFAULTS Use the and buttons to adjust P amp S Press ENTER TIME AND DATE SAMPLE DISPLAYS Ny SET WATER Use the and SET HEATING Press ENTER gt OORT THE CURRENT TIME SET HOLIDAY MODE a SET DEFAULTS Use the and buttons to adjust Ea Press ENTER THE DAY SET DEFAULTS v TIME AND DATE Use the and i i eeeenneener Press ENTER gt Bmore CLOCK OPTIONS THE MONTH HEADINGS Use the and buttons to adjust KS Press ENTER THE YEAR V 23 00 30 SEP 2009 Press the green 5300 Press ENTER gt vert pcan rae 4 0 SEP 200 Press the green Adjusting Clock Options The programmer has been preset to display the time in 24 hour Open cover clock format should you prefer AM PM format then please use Press the green SET button Use the and buttons to adjust KS Press ENTER CLOCK OPTIONS the procedure given in the flowchart Use the and opposite gt Bien em ors ras
7. etting or adjusting has not been finished please start the procedure again TIME OF DAY The ChannelPlus H21XL incorporates a factory set clock and calendar which means that no adjustments should be necessary to the time of day and BST GMT time changes take place automatically Manual Overrides BOOST FUNCTION 1 OR 2 HOUR TEMPORARY OVERRIDE The boost facility will allow the user to either activate a channel which is currently OFF for 1 or 2 hours or to extend a current ON period by 1 or 2 hours To indicate the boost being activated the BOOST button under the selected channel will stay illuminated for the duration of the boost extension period The display will also indicate the extension to the time visually on the display Press BOOST button a third time to cancel the period and return to the normal programme Press BOOST button twice for 2 hours of Press BOOST button once for 1 hour of hot water or central heating hot water or central heating ADVANCE FUNCTION BRINGS FORWARD THE NEXT ON OR OFF OPERATION The advance facility will allow the user to either bring a channel ON which is currently OFF or switch a channel OFF which is currently ON To indicate the advance feature being activated the ADVANCE button under the selected channel will stay illuminated until the next programme switching time the user display will change to also indicate the status of the channel and t
8. he next switching time To cancel the advance press the ADVANCE button again This will return the unit to its normal programme Press ADVANCE button once to move to the next ON OFF time Programme Override Facilities With the ChannelPlus H21XL Series 2 programmer operating in the normal running mode it is possible to alte r the functionality of the programme on each individual channel by means of the blue select buttons under the front flap The options include AUTO 1 Programmer follows all programmed ON and OFF times ALL DAY Channel operates from 1st ON time until 3rd OFF ignoring all switching ti mes in between ON Channel will be constantly ON OFF Channel will be constantly OFF there is the ability to turn off heating st during summer without altering the programme times 1 or 2 hour boost ill available All of the settings a alteration by the us The diagram below AUTO mode to begi bove will be permanent i e unaffected by programme times until er illustrates how to alter the setting it assumes that the channel is in the n with As both channels are totally independent it is possible to have them set differently if necessary Press SELECT Press SELECT once Programme goes from AUTO to ALL DAY Channel will operate from first ON until last OFF period again Programme goes from ALL DAY to ON
9. l ON indicator ADVANCE and ENTER button ILLUMINATED WHEN ACTIVE ADVANCE and PLUS button ILLUMINATED WHEN ACTIVE BOOST button ILLUMINATED WHEN ACTIVE BOOST and MINUS button ILLUMINATED WHEN ACTIVE Programme Select buttons Coloured Blue SET button Coloured Green Front Flap Lowered Display Information Holiday The ChannelPlus H21XL Series 2 Day function programmer has a fully graphical backlit Mme Date active display In the normal run mode the display is divided into 2 sections each section represents a controlled channel j j j j f FRI o The information d splayed will change channel 10 42 bimar depending upon the settings made and header 7 WATER aro which mode you are in During different ON On uni programming modes and or setting screens the current time day date holiday indicator will only appear when necessary this is to reduce confusion Channel Channel during the programming process This is Zone Zone explained further in later sections of this status status guide ACTIVATING THE BACK LIT DISPLAY The display will illuminate for approximately 1 minute whenever a button is pressed To illuminate the display for viewing purposes only press the green menu button under the front flap twice SETTING AND ADJUSTING When setting or adjusting the programmer will automatically return to the running mode if no buttons are pressed for approximately 1 minute If the s
10. nd off at the same time while others allow the domestic hot water and heating o come on and go off at different times Set the On and Off time periods to suit your own lifestyle On some programmers you must also set whether you want the heating and hot water to run continuously run under the chosen On and Off heating The time on the programmer must be correct Some types and Autumn at the changes between Greenwich Mean Tim You may be able to temporarily adjust the heating program periods or be permanently off have to be adjusted in Spring e and British Summer Time me for example Override Advance or Boost These are explained in the manufacturer s instructions The heating will not work if the room thermostat has switc hed the heating off And if you have a hot water cylinder the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct tempera HORSTMANN ture Email sales horstmann co uk Website www horstmann co uk Horstmann Controls Limited Bristol BS4 1UP C Leaflet number P82721 Issue 2
11. tings the programmer will return to its normal run mode in 1 minute if no adjustments are made in that time Setting the Holiday Mode The holiday mode can be used to suspend the program function of the ChannelPlus programmer it can be set in advance of your departure date and for as long a period as required The holiday function operates from mid day to mid day this means it can be easily set to ensure your home is warm for your return When the holiday mode has been set a smiley face will appear on the display When the holiday mode is active only the day date and smiley face will be displayed To cancel an active holiday period please press any of the Select buttons under the front flap y PLEASE NOTE Any alteration to the current ea thee saat time or date will cancel any Holiday Press the green HIB uttons to select 4 1 programme set SET button HOLIDAY MODE N B Do not use the holiday programme when conditions are Use the and v such that frost damage to the heating buttons to adjust C press ENTER system is possible unless a frost START DATE protection thermostat is fitted to your system Use the and Press ENTER gt OORT START MONTH SAMPLE DISPLAYS Use the and buttons to adjust Ea Press ENTER START YEAR Enter holiday dates SETTING HOLIDAY MODE START AT MID DAY ON arta FINISH AT MID DAY ON gt Repeat process for 21 SEPT

Download Pdf Manuals

image

Related Search

Related Contents

MANUEL D`UTILISATION TVmove®  American Standard Bathroom Aids ICU Sink System User's Manual  Cordless Sweeper Barredor Inalámbrico Balai Sans Cordon  Home Decorators Collection 0280700610 Instructions / Assembly  HOME AUDIO SYSTEM  JARtool User Manual PDF File    1600 Series LED Remote Display  Troubleshooting Avaya Aura System Manager 1.0    

Copyright © All rights reserved.
Failed to retrieve file