Home

en Operating Instructions REV200

image

Contents

1. Sl EMENS 4 Meaning of the symbols Change batteries h Time of day Locking of display active d Day CH Q a CC Heating equipment on 24 hour operating modes cI A Operating Instruction Holiday program active MINNI REV200 A MIMIN 1 heating period Remote operation active _Ill MI l if connected HMI 2 heating periods o il Il l C Room temperature mimimiM 3 heating periods Commissioning and quick startup The REV200 features a back lit touch screen display Settings are Activating the batteries made by touching the display fields with the fingers which also switches on the display lighting Tip to simplify programming the unit can be removed from its base 1 Remove the unit from its base 2 Open the cover of the battery compartment 3 Remove the black transit tab from the batteries The unit will switch itself on e Setting the time of day 4 Select the time button 5 Set the correct time of day with the arrow buttons Longer pressing causes the display to accelerate which can be stopped by repeated pressing 6 After 5 seconds the display will automatically return to the initial operating mode The same action is achieved by touching the time button again 4 Time button 5 Arrow buttons e Selecting the day of week 7 Touch the weekday button with the black triangle The display now shows only the weekdays Select the current weekday p 1 Mo 2 Tu etc ge 8 After 5 seconds the
2. display will automatically return to the initial operating mode The same action is achieved by touching the selected weekday button again 6 Weekday button e Selecting the operating mode of the heating periods 9 Select the operating mode j r al Goal e Operating mode Heating periods 07 00 23 00 mmm 06 00 08 00 11 00 13 00 17 00 22 00 a Mo Fr Il ll ll Sa Su IMM 7 day operating mode 24 hour operating mode to 3 1 7 1 5 ee 6 7 MANANAMI Do you want to choose your individual switching 7 day operating mode RE program You can choose a different switching pattern for each weekday e 7 day operating mode Each weekday can be selected individually 2 Weekday button 4 Switching time buttons 1 Touch the 7 day operating mode Auto 1 7 5 Arrow buttons Select the weekday to be programmed 2 3 Touch one of the three 24 hour operating modes 4 Touch the switching time button where you want to change the time The respective pointer on the switching time button and the time of day are flashing Use the arrow buttons to change the displayed switching time Touch the temperature display 7 Use the arrow buttons to change the displayed temperature P SS SSS ES SSE D o E 1 7 day operating mode 6 Temperature display 3 24 hour operating modes Tip check the settings made by selecting the individual days 24 hour operating mode fit fit jiu
3. e 24 hour operating mode This means that the same switching pattern is used for every day Individual weekday settings are not possible n 2 Switching time buttons _ 1 Touch one of the three 24 hour operating modes SS SL ee ee ae 2 Touch the switching time button where you want to change the Peni CRIES Gennes ne Rene KAR RGSS 3 Arrow buttons time The respective pointer on the switching time button and the switching time are flashing 3 Use the arrow buttons to change the displayed switching time Touch the temperature display 5 Use the arrow buttons to change the displayed temperature 4 Temperature button NG 24 hour operating modes Siemens SBT HVAC Products CE1B2212en 17 01 2002 E a Do you want to change the room temperature level With the level button you change from the current room temperature level to the other for a short period of time The active level will be i mor Te Ts Level bution displayed 3 or Use this function to reduce the room temperature level when the apartment is unoccupied 3 5 a The change is only active until the next switching point is reached Do you want continuous operation without changing the Select the required continuous operating mode The respective room temperature level temperature level will be maintained ee 3 Arrow buttons Default value 3 Continuously normal temperature 21 C Continuously economy temperature 16 C Conti
4. l L_ appear on the display Note the settings are retained for a maximum of 1 minute When this symbol appears you need to replace the batteries within the Do not activate the display lighting too often since this reduces next 3 months the batteries life Get 2 new alkaline batteries type AA 1 5 V Open the unit by pressing the button and remove it from its base Change the batteries Fit the unit at the top swing it down and snap on at the bottom Make certain exhausted batteries are disposed of properly The batteries life expectancy is about 2 years NO oo A PON o Siemens SBT HVAC Products CE1B2212en 17 01 2002
5. nuously OFF standby with frost protection 5 C Do you want to change these default values 1 Select the required continuous operating mode 2 Touch the temperature button 3 Change the temperature with the arrow buttons 2 Temperature button 1 Operating mode button Are you going on holiday When absent for a longer period of time it is possible to change to Activating the holiday function the economy temperature and to enter the time of absence 4 start day 2 24 hour button 1 Select operating mode Economy temperature Preselect the start day 1 7 of the holiday period Change the current economy temperature by touching the tem perature button and by changing the value with the arrow but ton 6 After 8 seconds the display will automatically return to the initi al operating mode The same action in achieved by touching the time button again The display keeps showing the number of days and the holiday e Displaying and cancelling the holiday function symbol Every midnight the counter subtracts one day When the counter reaches 00 an automatic change to the previous program will take place WEDDE 3 Arrow buttons 2 Touch the 24 hour button 3 Enter the number of days you are absent 0 99 4 5 4 Temperature button 1 Operating mode button 2 Arrow button Cancelling the holiday function 1 Touch the 24 hour button 2 Use the arrow button to set to OO 3 After 8 sec
6. onds the display will automatically return to the initial operating mode The same action is achieved by touching the 24 hour button again a P way La Q O g pu u Le onl re Lim Q 24 hour button Do you want to return to the default settings Press the reset button at top right for at least 3 seconds this will reset all individual settings and the time of day to their default O values During the reset time of 3 second the display will be fully lit E J 2 J 3 IE 8 IE JEJ 0 indicating that it works correctly SEE F Note after each reset all individual settings such as time of day d gt switching times and temperatures etc must be reentered rth CO Lid TH Co VA PH rege ae a lua ju Esi Ra Lo Reset button nm a ca mm E ea D a par 4 A Cleaning the display maintenance Switching on press the reset button at top right for a maximum of To clean the unit use the antistatic cloth provided or a soft damp 1 second O appears and all other displays will disappear The cloth with no chemical cleaning agent To clean the display the operating fields are now out of operation while all the other functions operating fields can be locked in the background remain fully operational Switching off press the reset button at top right for a maximum of 1 second 0 Locking of the display also serves as a protection against tampering O Reset button Does symbo