Home
Installation and Operating Instructions
Contents
1. requirement user s hee Appropriate Af fitting XX Bar mixers N maximum thickness of wall is about 20mm Fig 10 Enough room must be left on the connector to Locking nuts fit the compression nut and olive At the front Connector end an allowance MUST be made to accept the shower union and collar Flush out the pipework in accordance with Water Regulations and Byelaws Connect 15mm pipework using standard compression nuts and olives fig 11 NS Collar Flanges Seals Screw the supplied collars onto the fittings until eee tight to the wall 20mm ma thickness Offer the shower valve to the fittings and j checking that the sealing washers are place S screw the unions onto the fittings Fig 11 If installing with a combi multipoint system make sure the flow limiters are fitted NA LEAR TESTING Fit the hose to the outlet and direct it to vvaste Open the supplies and test for leaks in the valve connections Remedy any leaks if necessary COMMISSIONING N Make sure that both the hot and cold water supplies are fully open and at or near to their design temperature and pressures and are within the requirements as stated Check the temperature knob right hand side is rotated fully anti clockwise press the override button to achieve maximum temperature setting Make sure the showerhead is directed to waste Start the wat
2. 1 5 High volume of cold water drawn off elsewhere Action Cure 1 1 1 Refer to commissioning section 1 2 1 Turn temperature control anti clockwise 1 3 1 Turn temperature control anti clockwise 1 4 1 Turn off shower and consult a competent plumber or contact Triton Customer Service 1 5 1 Reduce the simultaneous demand from the supply 2 Water too cold 2 1 Temperature control incorrectly commissioned 2 2 Not enough hot water flowing through shower 2 3 Decrease in the ambient cold water temperature 2 4 Insufficient hot water supplies from the heating system 2 5 Hot water supply blocked or restricted 2 6 Flow limiter not fitted HP systems only 2 1 1 Refer to commissioning section 2 2 1 Turn the temperature control clockwise 2 3 1 Turn the temperature control clockwise 2 4 1 Make sure heating appliance is set to maximum or has sufficient stored hot water 2 4 2 Make sure heating appliance is igniting by trying a hot water tap elsewhere 2 5 1 Turn off shower and consult a competent plumber or contact Triton Customer Service 2 6 1 Fit the supplied flow limiter in the showerhead see instantaneous gas water heaters 3 High water 3 1 Flow limiters not fitted flow and or poor performance on a mains fed system 3 1 1 Fit the supplied limiter in the showerhead or inlets depending upon model see high pressure systems Bar mixers FAULT FINDING T
3. INSTALLATION Note The outlet of the shower MUST NOT be connected to anything other than the showerhead supplied DO NOT use jointing compounds on any pipe fittings for the installation DO NOT solder fittings near the mixer unit as heat can transfer along pipework and damage components Note Suitable service valves complying with Water Regulations and Byelaws MUST be fitted on the hot and cold water supplies to the shower as an independent means of isolating the water supplies should maintenance or servicing be necessary When connecting the pipework avoid using tight 90 elbows Swept or formed bends will give the best performance Straight fittings The supply pipes can be routed either from the side rising rear or falling and must end in suitable fittings fig 9 to accept the long thread connectors The straight connectors can be used to connect to BSP female elbow fittings in solid wall installations The inlet centres on the shower valves must be aligned horizontally and centred to 150mm The hot and cold supply pipes must be anchored rigidly to support the valve and to prevent any movement after installation If installing in hollow walls or laminate cubicles fittings are supplied to compress onto the wall to support the mixer valve fig 10 Ve Fig 8 diagrammatic view not to scale Showerhead can be mounted either side of the mixer Height of showerhead to suit
4. 20 C FTDITAN CTANRADAR FIHADANITEE TRITON STANDARD GUARANTEE With the exception of accessories Triton guarantee the product against all manufacturing defects for a period of 5 years for domestic use only from the date of purchase provided that it has been installed by a competent person in full accordance with the fitting instructions All accessories such as shower heads hoses and riser rails carry a 1 year parts only guarantee against manufacturing defects Any part found to be defective during this guarantee period we undertake to repair or replace at our option without charge so long as it has been properly maintained and operated in accordance with the operating instructions and has not been subject to misuse or damage This product must not be taken apart modified or repaired except by a person authorised by Triton This guarantee applies only to products installed within the United Kingdom and does not apply to products used commercially This guarantee does not affect your statutory rights What is not covered 1 Breakdown due to a use other than domestic use by you or your resident family b wilful act or neglect c any malfunction resulting from the incorrect use or quality of electricity gas or water or incorrect setting of controls d failure to install in accordance with this installation guide 2 Claims for missing parts once the product has been installed 3 Repair costs for damage caused by foreig
5. hot water at a minimum switch on flow rate of 3 litres per minute At flow rates between 3 and 8 litres per minute the appliance must be capable of raising the water temperature to a minimum of 52 C Water temperature at the inlet to the mixer must remain relatively constant when flow rate adjustments are made refer to the water heater operating manual to confirm compatibility with this mixer shower This mixer is supplied with an integral single check valve and integral filter in each inlet Inlet connections are to 15mm compression or BSP female fittings not supplied SAFETY WARNINGS a Layout and sizing of pipework must be such that when other services are used pressures at the shower control inlets do not fall below the recommended minimum b DO NOT choose a position where the shower could become frozen lt DO NOT connect this mixer shower to any form of tap or fitting not recommended by the manufacturer d The showerhead MUST be regularly cleaned to remove scale and debris e Conveniently situated service valves in each inlet supply MUST be fitted as an independent method of isolating the shower should maintenance or servicing be necessary f If it is intended to operate the shower in areas of hard water above 200 ppm temporary hardness a scale inhibitor may have to be fitted For advice on the Triton scale inhibitor please contact Customer Service g DONOT operate the shower outside the guide
6. premises Where thermal store systems and instantaneous gas water heaters are used if excessive draw offs take place the boiler may not be able to maintain an adequate output temperature This could result in the shower temperature becoming noticeably cooler Water temperature requirements Maximum hot water temperature 80 C Recommended maximum 65 C Minimum hot water temperature 52 C Maximum cold water temperature 20 C BS 6700 recommends that the temperature of stored water should never exceed 65 C A stored water temperature of 60 C is considered sufficient to meet all normal requirements and will minimise the effects of scale in hard water areas Temperature adjustment range The mixed water temperature can be adjusted from cold through to a top limit which can be preset during installation This is with full anti scald protection throughout the range 35 C to 40 C providing the hot water temperature at the inlet remains 10 C above the outlet temperature Bar mixers gt TYPICAL SUITABLE INSTALLATIONS a Instantaneous gas heated systems e g combination boilers fig 2 The shower control MUST be installed with a multipoint gas water heater or combination Combination boiler of a fully modulating design i e boiler to maintain relatively stable hot water temperatures Fig 2 diagrammatic view not to scale A drop tight pressure reducing valve MUST be fitted if the supply pressure
7. reducing valve to the cylinder Expansion vessel Pressure reducing valves The layout and sizing of pipework MUST be Balanced cold mains supply such that nominally equal inlet supply pressures are achieved and the effects of other draw offs are minimised Cold mains supply sa A Bar mixers c Mains pressurised thermal store gt systems fig 4 Fig 4 diagrammatic view not to scale Packages of this type fitted with a tempering valve blender valve can be used A drop tight pressure reducing valve MUST be fitted if the supply pressures exceed 5 bar running An expansion vessel shown in fig 4 MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal store check with thermal store manufacturer Service valves lt d Gravity fed systems fig 5 The shower control MUST be fed from a cold ji s P xpansion water cistern and hot water cylinder providing vessel nominally equal pressures There must be a H P minimum of between 1 and 5 metres head of y 3 t water depending on the shower model The valve Flow minimum head distance is measured from the Stop base of the cold water cistern to top of the showerhead fig 5 Cold mains supply A Pumped gravity fed systems va fig 6 Fig 5 diagrammatic
8. same fixed price and the customer will be expected to pay the engineer before he leaves If payment is not made on the day an administration charge will be added to the fixed charge 9 debt is outstanding from a previous visit or from any other Triton Triton reserves the right to withhold service until the debt as been settled 10 Triton takes the health safety and wellbeing of its employees very seriously and expects customers to treat all staff members with respect Should any employee feel threatened or receive abuse either verbally or physically Triton reserves the right to withhold service and will support the employee with a legal prosecution Replacement Parts Policy Availability It is the policy of the manufacturer to maintain parts availability for the duration of production and a period of five years thereafter in accordance with industry standards Spare parts are available via our website www tritonshowers co uk or by telephoning Triton Customer Service Spares Department Payment should be made by credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or money order Telephone orders are based on information given during of the call Before contacting Triton please verify your requirements using the information contained in the supplied user guide Triton cannot accept liability for incorrect part identification
9. view not to scale The shower control MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressures Stop valve The mixer unit may be used with a gravity fed system with a pump to boost pressures as shown There must be a minimum of 0 15 metre head to activate the pump fig 6 Cold supply Minimum head Cold Hot supply water D mains supply Alternative supply El Hot vvater cylinder Bar mixers Fig 6 diagrammatic view not to scale Stop valve Cold supply Minimum Gate nead valve ADN Cold Hot supply water mains supply Alternative supply Hot water cylinder Service Service valve valve 07 ca i ae Hamed i valve Other draw offs isolating switch or pull switch both LE __ _ _fused at3A _ Ring main S J N Fig 7 Threaded Filter retainer Q Long thread i fitting Flow regulator check facing N INSTANTANEOUS WATER HEATERS APPLIANCE CAPABILITIES In order to provide the best performance from the shower when connected to an instantaneous water heater the appliance must be capable of raising the temperature of the incoming water to a minimum of 52 C 125 F and delivering a flow r
10. TRITON TYNE Thermostatic bar mixer shower Installation and Operating instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180431E February 2013 Bar mixers CONTENTS Page 1 Safety 1 Maim Components ses est ta 2 Site reqUirementS 5 iscsssscsessessesceseacdedsoceescceessesasteesssesoivasassessesdeseteese 3 4 5 Instantaneous water heater appliance capabilities 6 Preparing the Mixer 6 Siting of RE SON Ec ese sea tot 7 Installationisccsccscccsscssssesssscsssessstesssssssetseseeosesvecossesseeas cdesassatssscoseazs 7 8 8 COMMIUSSIOMNIAGS 8 9 Operating the SHOWET 9 Cleaning 9 S Pare parts i 11 a ae 11 12 Guarantee Service POLICY rear cover To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service before installation Telephone 0844 980 0730 Fac
11. ate of not less than eight litres per minute Flow limiters supplied MUST be inserted into the long thread straight connectors as follows Insert the filter then the flow limiter Fig 7 and secure in place with the threaded retainer With the flow limiter fitted and when the system is in use the On Off flow control should be turned fully anti clockwise to the full flow setting PREPARING THE MIXER VALVE WARNING The shower must not be positioned where it will be subject to freezing conditions Check the contents to make sure all parts are present Before installing make sure all the openings on the valve are carefully covered to stop ingress of any debris etc while routing the supply pipework The shower valve is suitable for installation on a solid wall a stud partition wall dry lined wall or fixing to a laminate cubicle or panel The hot and cold water pipes should be securely attached within the wall or panel to support the valve and prevent movement after installation The hot water inlet has a red symbol next to the inlet and must be on the left hand side Bar mixers SITING OF THE SHOWER Refer to fig 8 for correct siting of the shower Position the shower and showerhead on the wall so that all controls can be comfortably reached while using the shower The showerhead can be positioned either side of the shower The unit must be positioned horizontally with the outlet port at the bottom
12. er flow by turning the flow control left hand side anti clockwise Allow the shower to run at the maximum temperature setting until the water temperature has stabilised Using the temperature control knob rotate until your desired maximum showering temperature is reached The mixer valve contains a maximum temperature override button set at 38 C The mixer valve is factory set to give a maximum outlet temperature of 38 C This should be checked on site to make sure the setting has not been altered and also to make sure of user safety Bar mixers Adjusting the maximum temperature override setting When you are satisfied with the showering temperature remove the temperature control knob by removing the end cap and unscrewing the retaining screw fig 12 Reposition the control on the spline so the peg inside the control engages against the stop fig 13 on the temperature control body Refit the controls and secure in place with the screw OPERATING THE SHOWER To start the shower rotate the On Off flow control left hand side fully anti clockwise for maximum flow To stop the water flow rotate the On Off flow control fully clockwise To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or anti clockwise for a hotter shower To overcome the maximum temperature stop depress the button on the temperature control CLEANING THE FILTERS T
13. he following is recommended for a professional qualified installer only Problem Symptom Cause 4 Water does not flow or shower pattern collapses when another outlet is turned on 4 1 Water supplies cut off 4 2 Shower unit blocked 4 3 Blockage in pipework 4 4 Showerhead blocked 4 5 System not capable of supplying multiple outlets at the same time Action Cure 4 1 1 Check water elsewhere in house and if necessary contact local water company 4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn the shower off and consult a suitably competent plumber 4 4 1 Clean showerhead 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valves are fully open 4 5 3 Check if sufficient water pressure 5 Water too cold 5 1 Running pressure in excess of maximum recommended 5 1 1 Fit a pressure reducing valve 6 Shower controls noisy while in use 6 1 Running pressure in excess of maximum recommended 6 1 1 Fit a pressure reducing valve 7 1 Flow control washer worn 7 Shower will not shut off 7 1 1 Renew flow control washer Bar mixers UK SERVICE POLICY In the event of a product fault or complaint occurring the following procedure should be followed 1 Telephone Customer Service 0844 980 0750 having available your details including post code the model number and power rating of the product together with the date of purchase and where ap
14. lines as laid out in site requirements Replacement parts can be ordered from Triton Customer Service See spare parts for details and part numbers Bar mixers COMPONENTS Fig 1 1 Tyne thermostatic mixer valve 2 Long thread straight inlet connector 3 Bar valve bracket optional Showerhead Riser rail assembly Bar mixers SITE REQUIREMENTS The installation must be in accordance with Water Regulations and Byelaws Running water pressure Gravity fed 0 1 bar min to 5 0 bar max Mains 1 0 bar min to 5 0 bar max Maximum static water pressure Gravity and mains 10 bar DO NOT connect the mixer shower to a gravity hot supply and a mains cold supply or vice versa For the best performance within the specified running pressure range a minimum flow of eight litres per minute should be available to both inlets While the mixer shower is operational open outlet inlet pressures must not be capable of exceeding 7 bar For effective operation of the internal seals the maximum static pressure must not be exceeded Note On sites where the running pressure is above 5 bar the use of a suitably sized pressure reducing valve fitted in the cold mains supply pipework can provide nominally equal pressures at the mixer shower The pipework should be installed such that the flow is not significantly affected by other taps and appliances being operated elsewhere on the
15. n objects or substances 4 Total loss of the product due to non availability of parts 5 Compensation for loss of use of the product or consequential loss of any kind 6 Call out charges where no fault has been found with the appliance 7 The cost of repair or replacement of pressure relief devices showerheads hoses riser rails and or wall brackets isolating switches electrical cable fuses and or circuit breakers or any other accessories installed at the same time 8 The cost of routine maintenance adjustments overhaul modifications or loss or damage arising therefrom including the cost of repairing damage breakdown malfunction caused by corrosion furring 9 Call out charges where the water supply cannot be isolated this includes consequential losses arising from unserviceable supply valves For the latest Terms amp Conditions please see www tritonshowers co uk d Triton Showers Triton Road Nuneaton Warwickshire CV11 4NR Triton is a division of Norcros Group Holdings Limited Customer Service 0844 980 0750 Trade Installer Hotline Z 0844 980 0730 Fax 0844 980 0744 www tritonshowers co uk E mail serviceenquiries tritonshowers co uk TRITON reserve the right to change product specification without prior notice E amp OE TRITON SHOWERS 2013
16. plicable details of the particular fault 2 If required the Customer Service Advisor will arrange for a qualified engineer to call 3 All products attended to by a Triton service engineer must be installed in full accordance with the Triton installation guide applicable to the product Every product pack contains an installation guide however they can also be bought via our Customer Service Spares Department 4 Our engineer will require local parking and if a permit is required this must be available to the engineer on arrival at the call 5 It is essential that you or an appointed representative who must be over 18 years of age is present for the duration of the service engineer s visit If the product is in guarantee you must produce proof of purchase 6 Where a call under the terms of guarantee has been booked and the failure is not product related i e scaling and furring incorrect water pressure pressure relief device operation electrical plumbing installation fault a charge will be made A charge will also be issued if nobody is at home when the service engineer calls or adequate parking permit is not available 7 If the product is no longer covered by the guarantee an up front fixed fee will be charged before the site visit 8 Should proot of purchase not be available on an in guarantee call or should the service engineer find that the product is no longer under guarantee the engineer will charge the
17. s exceed 5 bar running An expansion vessel shown in fig 2 MUST be fitted and regularly maintained to prevent the shower mixer being damaged by excess pressures This may already be installed within the boiler check with manufacturer and is in Expansion ead vassal CH return addition to the normally larger central heating poran expansion vessel supply Stop Pressure The layout and sizing of pipework MUST be tap reducing valve such that nominally equal inlet supply pressures are achieved and the effects of other draw offs Ne minimised The hot supply temperature MUST remain a minimum of 10 C hotter than Fig 3 diagrammatic view not to scale the required blend temperature for optimum performance b Unvented mains pressure systems fig 3 The shower control can be installed with an unvented stored hot water cylinder Safety devices not shown For systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing 4 valve when the mains pressure is over 5 bar The drop tight pressure reducing valve must be set at the same value as the unvented package Unvented hot water pressure reducing valve storage unit Note An additional expansion vessel fig 3 may be required if a second pressure reducing valve is installed This does not apply to packages with a cold take off after the pressure
18. simile 0844 980 0744 E mail technical tritonshowers co uk Bar mixers INTRODUCTION This book contains all the necessary fitting and operating instructions for your Unichrome Tyne thermostatic bar mixer shower Please read the instructions carefully Read through the whole of this book BEFORE beginning your installation The shower installation MUST be carried out by a suitably competent person and in sequence of this instruction book Care taken during the installation will provide a long and trouble free life from your shower For best performance within the specified running pressure range a minimum flow of eight litres per minute should be available to both inlets The mixer shower MUST NOT be subjected to water temperatures above 80 C The mixer is designed for use with traditional low pressure gravity water systems using a cold water cistern and hot water cylinder All the models are suitable for the higher pressure systems found in the UK up to a maximum of 5 bar running pressure IMPORTANT When installing this mixer with a combination boiler or multi point a flow restricter MUST be installed in the unit The mixer is suitable for fully modulating type combination boilers and multi point hot water heaters It is also suitable for thermal storage unvented systems and pumped gravity systems IMPORTANT Before installing with a gas instantaneous water heater make sure it is capable of delivering
19. urn off the water supplies before starting To gain access to the filters remove the unit from the inlet fittings Remove the sealing washers from the union inlets and unscrew the filter cap on each inlet fig 14 Remove the filter and wash the filter thoroughly under running water to remove all debris Replace the filter into the recess on the cap and screw the unit back into each inlet union Reassemble the shower to the inlet fittings Maximum temperature stop Valve spindle Filter cap Filter A Ne Bar mixers SPARE PARTS N PLEASE NOTE fitting has Left Hand thread Ref Description Part No Ref Description Part No 1 Closure knob 83307490 8 Inlet assy complete 2 83315250 2 Mechanic headwork 83307320 9 Bar bracket optional UNBMXBKT 3 Thermostatic cartridge 83307500 4 Regulation 83307510 5 Non return valve 83307290 6 Tim Pack 86001150 7 Straight inlet connector UNPIPCON Bar mixers FAULT FINDING The following can be carried out by a competent person Problem Symptom Cause 1 Water too hot 1 1 Temperature control incorrectly commissioned 1 2 Not enough cold water flowing through shower 1 3 Increase in the ambient cold water temperature 1 4 Cold water supply blocked