image

Contents

1. J J 21 Screen Operating mode Recipe 22 Operating mode GramIMag eG Pe 23 PURE TO sayu nuansa tee aaa Aa Ba 24 Contents Of the form impression J J 24 Arrangement of torm PRIMO UU uuu Raya EE S usss 25 PKP PKS BA e 1313 ISO S roh AA ALL 26 Data Output RS 232 c 26 interface RS 232G ia aaa naa sao M aaa 26 There are 4 kinds of data output via RS 2326 27 Explanation Of the data translo tts n a ete Q tato ase nas 27 Pilli yo naa x TN ES 28 28 Service maintenance disposal 29 ee EE EU 29 Service maintenant e uu u uuu uu 29 Pj Bem 29 Dam ny 30 Declaration of conformilty 31 PKP PKS BA e 1313 3 1 Technic
2. de conformidade EC ProhlaSeni o shode EC Deklaracja zgodnosci O D Konformit ts Wir erkl ren hiermit dass das Produkt auf das sich diese Erkl rung bezieht erklarun mit den nachstehenden Normen Ubereinstimmt GB Declaration of We hereby declare that the product to which this declaration refers conforms conformity with the following standards CZ Prohlaseni o T mto prohla ujeme Ze v robek kter ho se toto prohl en t k je v souladu shode s n e uveden mi normami E Declaraci n de en la presente que el producto al que se refiere esta conformidad declaraci n est de acuerdo con las normas siguientes F D claration de Nous d clarons avec cela responsabilit que le produit auquel se rapporte la conformit pr sente d claration est conforme aux normes cit es Dichiarazione di Dichiariamo con cio che il prodotto al quale la presente dichiarazione si conformit riferisce conforme alle norme di seguito citate NL Conformiteit Wij verklaren hiermede dat het product waarop deze verklaring betrekking verklarin heeft met de hierna vermelde normen overeenstemt P Declara o Declaramos meio da presente que produto no qual se refere esta conformidade declarac o corresponde s normas seguintes PL Deklaracja Niniejszym o wiadczamy ze produkt kt rego niniejsze o wiadczenie dotyczy zgodno ci jest zgodny z
3. KERN amp Sohn GmbH V 4 WAA GEN GEWICHTE 4 LA NCE S WEIGHTS Ziegelei 1 Phone 49 0 7433 9933 0 D 72336 Balingen Fax 49 0 7433 9933 149 email info kern sohn com Internet www kern sohn com Operating instructions Precision balance KERN PKP PKS Version 1 3 06 2013 GB PKP_PKS BA e 1313 KERN PKP PKS C eB 5 Version 1 3 06 2013 Operating instructions Industrial scale with graphic display Table of Contents Technical Dale on i254 092205 0292009 0192256 026200 50080203 0815203 028102820 0122 01096 2 00 04 4 Basic Information General 7 uio mene 7 Mott 7 WY QU AIM V PETRO 7 Monitoring or T est R amp SQOUPCeS uu u uuu uu u xul Easter Wa a cu dao eire tuia Cosa ala a a aaa gala aaa 7 Basic Safety PreGauuiOns 222590 uu eoa a een 8 Pay attention to the instructions in the Operation Manual eee 8 PerSonn el e TG 8 Transportation amp Storage s u 8 nnnm 8 Packaging IraRSpDOrluu uu E 8 Unpacking Setup and Commissioning 9
4. 40 SG temperature Housing B x D x H 180 x 310 x 90 mm Weighing plate 106 150 stainless steel mm Data interface yes RS232 PKP PKS BA e 1313 5 max Adjustment points 2 5 10 12 kg 10 kg 10 kg 5 kg 20 kg Humidity of air max 80 rel non condensing Hecommended adjusting weight F1 not supplied Stabilization time typical Permitted 3 Sec environmental 10 40 C temperature Housing B x D x H 180 x 310 x 90 mm Weighing plate 160 x 200 stainless steel mm Data interface yes RS232 PKP PKS BA e 1313 2 Basic Information General 15 absolutely necessary that you read and understand the operating instructions prior to Installation and commissioning and follow the instructions during the process 2 1 Proper use The balance you purchased is intended to determine the weighing value of material to be weighed It is intended to be used as a non automatic balance i e the material to weighed is manually and carefully placed in the centre of the weighing plate As soon as a stable weighing value is reached the weighing value can be read 2 2 Improper Use Do not use balance for dynamic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the balance Example Slowly draining fluids from a container on the balance
5. Config au 9 cont Config Basic settings Communi Basic settings e pea T 3 2 gt Weighing 2x gt Weighing 2x Password Interface a ee Gur 0 JT ON Auto pr gt Aut zero 2x 5 suite 3x Units PKP PKS BA e 1313 15 6 4 Operating mode Counting Select Operating mode in basic settings Nr G 9 2 Counting Before setting Set up Container Set up REF quantity as selected Apply counted quantity Read counted quantity 16 with selected REF quantity REF weight memory Adjust gt Memo gt 2x Referenc pese RA 2 Next Referen vm Set up Container Apply counted quantity Read counted quantity remove all Counting select create REF quantity REF weight Adjust gt Memo du Man tare bp Ji 13 fo 2 e d Referen 2x 3Desen ot r Enter Descrip More signs 7 dud Referen 3x Quantit OK Enter quantity INA Referen eight JK More digits du eps Enter Weight More digits PKP PKS BA e 1313 6 5 Operating mode Totalizing Select Operating mode in basic settings Nr G 9 3 Befo re setti ng without Singel Print Totalizing Totalizing Print daily total Clear different types daily total of printing Confi Adjust Config apply subset remove subs
6. Do not leave permanent load on the weighing plate This may damage the measuring system Impacts and overloading exceeding the stated maximum load max of the balance minus a possibly existing tare load must be strictly avoided Balance may be damage by this Never operate balance in explosive environment The serial version is not explosion protected The structure of the balance may not be modified This may lead to incorrect weighing results safety related faults and destruction of the balance The balance may only be used according to the described conditions Other areas of use must be released by KERN in writing 2 3 Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored he appliance is used outside the described uses he appliance is modified or opened mechanical damage and damage caused by media liquids natural wear and tear he appliance is improperly set up or incorrectly electrically connected he measuring system is overloaded 2 4 Monitoring of Test Resources In the framework of quality assurance the measuring related properties of the balance and if applicable the testing weight must be checked regularly The responsible user must define a suitable interval as well as type and scope of this test Information is available on KERN s home page www kern sohn com with regard to the monitoring of balance test substances and the test weights required for thi
7. Installation Site Location of Use Sd wu Ua Dat 9 9 PAGING me T R 9 8 eme cR 9 Connection of peripheral devices ccc d ce couse ad pus auc eu suuni ve ya aG pU Cura Sus amun 9 Mitia GOmMMISSIONINO uuu nee 9 ATU SUNG uuu oc 10 Adi Si i uuu 10 11 Screen and oDeratlolic a e 11 How totum on off Balance uu uu 12 Basic SEINO S aiana e A E E qvx E Dana us v OlUG E anaa E EN EE 13 Operating mode Counting uuu l lll l lll l eco tao Eau vase aa ngk aja d aran aa a aa aa a ara anaa unus EL aa dude 16 Operating mode Tolali glIng een 17 Operanng mode DISPENSING uuu uu aun uy ay bau k Q ee qa NG a a a a udus 18 Operating mode Check weighing U J J 19 Operating mode PerCe nt uu u 20 Operating mode Animal weighing
8. V Multiplier 1 m o 6g L67m g V measuring object More digits Navigation keys Function keys P ems PSS v es VES e tiny S Oase die o PKP PKS BA e 1313 23 7 Print form 7 1 Contents of the form impression Print Form Variable Fix text Variable Date Fix text 1 Variable Time Fix text 2 Variable Operator Variable Designation Variable Gross Variable Net Variable Tara Variable Pretare Variable Quantity Variable Numerator Variable Balance ID Variable Serial no Variable Piece weight Variable Ref pce weight Variable Target value Variable Deviation Variable AVG Value Variable Surface weight Variable Percent Fix text 20 EN PKP_PKS BA e 1313 7 2 Arrangement of form printout Variable Variable Gross Activated ON Line 2 Column 1 Printout Gross line 2 column 1 1 line 1500 00 g XXXXXXXXXXXXXX 2 line Printout Gross line 2 column 12 XXXXXXXXXXXXXXXXXXXXXXXXXX 1 line XXXXXXXXXXXX1500 0 g xxxxx 2 line Fix text Fix text 1 Activated ON Line 2 Column 1 Designation Gross Printout Designation contents XXXXXXXXXXXXXXXXXXXXXXXXXX 1 line Line 2 column 1 E Gross XXXXXXXXXXXXXXXXXX 2 line Combination of fix text and variable Fix text Gross line 2 column 1 XXXXXXXXXXXXXXXXXXXXXXXXXX 1
9. from power supply The weighing process must then be restarted from the beginning Help Fault Possible cause The displayed weight does not glow e The balance is not switched on hemains supply connection has been interrupted mains cable not plugged in faulty e Power supply interrupted The displayed weight is permanently e Draught air movement changing e Table floor vibrations e Weighing plate has contact with other objects e Electromagnetic fields static charging choose different location switch off interfering device if possible The weighing value is obviously e The display of the balance is not at zero wrong e Adjustment is no longer correct e Great fluctuations in temperature e Electromagnetic fields static charging choose different location switch off interfering device if possible Should other error messages occur switch balance off and then on again If the error message remains inform manufacturer 30 PKP_PKS BA e 1313 11 Declaration of conformity N KERN amp Sohn GmbH D 72322 Balingen Frommern Tel 0049 0 7433 9933 0 A WAAGEN GEWICHTE BALANCES WEIGHTS Postfach 4052 Fax 0049 0 7433 9933 149 E Mail info kern sohn de Internet www kern sohn de Declaration of conformity EC Konformitatserklarung EC Declaration of Conformity EC Declaration de conformite EC Declaracion de Conformidad EC Dichiarazione di conformita EC Conformiteitverklaring EC
10. line Variable gross value line 2 column 12 Gross 1500 0 2 line X space character The fields line and column are position printing input fields Field Variable is a selection field of fixed printing possibilities Field Fix text offers the possibility to specify texts for printout The field designation is a text input field to add information such as gross tare net pcs to the values Field Activated on takes over this line into the print form PKP PKS BA e 1313 25 8 Interfaces 8 1 Data output RS 232 C Technical data 8 bit ASCII Code 1 start bit 8 data bits 1 stop bit no parity bit Baud rate selectable from 2400 4800 9600 Baud factory setting and 19200 Baud e Sub D plug 9 channel required For operation with interface faultless operation is only ensured with the correct KERN interface cable max 2m Pin allocation of the balance output socket front view Sub D jack 9 channel 5 1 Pin 2 Ou QOO E I 6 6 545 Pin 3 Pin 5 9 6 8 2 Interface RS 232C Data output via interface RS 232C General Transmit data Heceive data Signal ground The previous condition for the data transfer between balance and a peripheral device e g printer PC is that the appliances are set to the same interface parameters e g baud rate parity 26 PKP PKS BA e 1313 8 2 1 There are 4 kinds of data output via RS 232C D
11. poni szymi normami RUS o K Electronic Balance KERN PKP PKS Directive 7 Standards 2004 108 EC EN 55011 2009 A1 2010 EN 55022 2010 AC 201 1 EN 55024 2010 EN45501 1992 10 AC 1993 08 OIML R 76 1 2006 OIML R 76 2 2006 EN60950 Datum 08 04 2013 Date Signatur Signature Ort der Ausstellung 72336 Balingen Albert Sauter Place of issue KERN amp Sohn GmbH Geschaftsfuhrer Managing director KERN amp Sohn GmbH Ziegelei 1 D 72336 Balingen Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 E Mail info kern sohn com Internet www kern sohn com PKP_PKS BA e 1313 31
12. al Data Models PKS 2000 2 3600 2 Weighing range max 360 g 2 000 g 3 600 g 10 000 g Taring range subtractive 360 g 2 000 g 3 600 g 10 000 g Smallest piece weight 0 001 g 0 001 g 0 01 g 0 019 50 100 150 100 200 300 0 5 1 0 1 5 1 0 2 0 3 0 Adjustment points 200 g 360 g 2 0 kg 3 6 kg 2 5 10 kg Hecommended adjusting weight F1 200g 2009 1009441 20000 2 kg 1 kg 10 kg not supplied Humidity of air max 80 rel non condensing Stabilization time Allowable ambient 10 40 C temperature Housing B x D x H PRA 167 x 250 x 85 Vibration filter Weighing plate 130 x 130 150 x 170 stainless steel mm Data interface yes RS232 4 PKP PKS BA e 1313 Models PKP KERN PKP 300 3 PKP 420 3 PKP 3000 2 PKP 4200 2 Readability d 0 001 g 0 001 g 0 01 g 0 01 g YYelgning range 300 g 420 g 3 000 g 4 200 g max subtractive 420 g 3 000 g 4 200 g Reproducibility 0 002 g 0 002 g 0 02 g 0 02 g 0 005 g 0 005 g 0 05 g 0 05 g Smallest piece weight 0 001 g 0 001 g 0 01 g 0 01 g 50 100 200 100 200 300 1 0 1 5 2 0 3 0 1 0 2 0 3 0 4 0 P 300 400 kc kc Hecommended adjusting weight F1 200 g 100 g 2000 2000 2 0 1 0 2kg 2kg not supplied Humidity of air max 80 rel non condensing 62 O O Stabilization time typical Permitted 3 sec environmental
13. amage 8 PKP_PKS BA e 1313 5 Unpacking Setup and Commissioning 5 1 Installation Site Location of Use The balances are designed in a way that reliable weighing results are achieved in common conditions of use You will work accurately and fast if you select the right location for your balance Therefore observe the following for the installation site Place the balance on a firm level surface Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight Protect the balance against direct draughts due to open windows and doors Avoid jarring during weighing Protect the balance against high humidity vapors and dust Do not expose the device to extreme dampness for longer periods of time Non permitted condensation condensation of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment In this case acclimatize the disconnected appliance for ca 2 hours at room temperature Avoid static charging of the material to be weighed weighing container and windshield If electro magnetic fields or static charge occur or if the power supply is unstable major deviations on the display incorrect weighing results are possible In that case the location must be changed 5 2 Unpacking Carefully remove the balance from the packaging remove plastic cover and setup balance at the intended workstation 5 2 1 Placing Level ba
14. ata output using the PRINT key The printing process can be triggered by pressing the PRINT key The settings AUTOPRINT and AUTOPRINT should be disabled for this process AUTOPRINT data output according to weight application The setting AUTOPRINT is located on the menu item Data transfer G10 for basic settings where you can turn it on or off When AUTOPRINT is active the current weighing value will be sent via the RS 232 date interface after unloading and subsequent loading of the balance as soon as the balance is in resting position Permanent PRINT continuous data output The setting Permanent Print is located on the menu item Data transfer G10 for basic settings where you can turn it on or off When Permanent Print is active the current weighing values will be sent continuously via the RS 232 data interface Data output and remote control commands The setting Remote Control Command is located on the menu item Data transfer G10 for basic settings where you can turn it on or off Hemote control commands transferred as ASCII characters to the balance can be used to trigger the following functions on the balance always finish with CR LF t Taring W The balance sends a weighing value also unstable via the serial interface 5 The balance sends a stable weighing value the serial interface After receiving either character w or s the balance will send without a printer pause between the characters 8 2 2 Explanatio
15. ate Config Communi Interface gt of tran Auto pr 2x 2Numerat Ed 9 8 emb v sS Navigation keys Function keys A ENN E Ue ees a GARA Ba akan A Ra Res gd Pas REN ianh Saka 13 A 0 U A D a r 2 Basic settings G11 create Operator setting create manual weighing 99 RS 232 data transfer S13 stability S m Adjust gt Adjust Config Adjust Adjust gt Memor Config i Config gt Communi Config Man tare gt Operator Config Man tare ehing Interface Type of transf Next operator Next Man tare peo Lf epe dun MN fa ft Baudrat ii k r Enter Enter Descript Descript Datenbit igi signs 8 Gia Select Operating mode v More signs ha v Operator gt Active Config 2x2 Weighing dud five von More signs 3x Mode w Man tar Active 14 PKP_PKS BA e 1313 Basic settings GLP printout 5 Auto Zero Zero passing 619 r acusa print with units 617 activate 618 activate device code autom tared new print at zero Balance must be zero tracking relieved MER Adjust Adjust Adjust Config
16. ed from the hook and carry out the weighing Always ensure that all suspended objects are stable enough to hold the desired goods to be weighed safely danger of breaking N Never suspend loads that exceed the stated maximum load max danger of breaking CAUTION Always ensure that there are no persons animals or objects that might be damaged underneath the load e After completing the underfloor weighing the opening on the bottom of the balance must always be closed dust protection 28 PKP PKS BA e 1313 9 Service maintenance disposal 9 1 Cleaning Before cleaning please disconnect the appliance from the operating voltage Please do not use aggressive cleaning agents solvents or similar agents but a cloth dampened with mild soap suds Ensure that no liquid penetrates into the device and wipe with a dry soft cloth Loose residue sample powder can be removed carefully with a brush or manual vacuum cleaner Spilled weighing goods must be removed immediately 9 2 Service maintenance The appliance may only be opened by trained service technicians who are authorized by KERN Before opening disconnect from power supply 9 3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used PKP PKS BA e 1313 29 10 Instant help In case of an error in the program process briefly turn off the balance and disconnect
17. et Basic settings Setting mod Basic settings Basic settings Setting mod Setting mod Print daily tot 2x Singlep Print daily tot Print daily tot Clear daily tot NEM pe pom III Legend AT CE pe ee LE aao Navigation keys _ Functionkeys PKP PKS BA e 1313 17 6 6 Operating mode Dispensing Select Operating mode in basic settings Nr G 9 7 Dispensing Before setting Dispensing without with memory memory Enter Target Adjust weight gt Memo 0 Man tare 2x gt Di pense More OTRA digits next Dispense LOK didit Set up More Container digits NOBEL Dispensing to target weight remove all Set up Container Dispensing to target weight 18 y 4 target weight dispensing aid select Config AH Basic settings Setting mod Subt Norm Adjust gt Memo n Dispense n Limit OK ie in Enter Differ Man tare 2x 2Disp ense k E Dispense n 2x gt Descrip JK More digits Enter Descrip Dispensen More Limit signs Enter Differ Dispense n 3x Weight JK Enter weight More digits em vert ng EKOE an vo p Navigation keys Function keys a 6 25 5 PKP PKS BA e 1313 6 7 Operating mode Check weighing Select Operating mode in basic settings Nr G 9 5 Basic s
18. etti ng Checkweighing Checkweighing with memory weight guantity Z Limit gt Memo Enter Monitore Differ 2x2 Monit oF Adjust Adjust Memo Contis um d Man tare 2x 2 or Setting mod 9 next Monitor lt 2 mE o 2 digits rm gt L q OQ O 33 AJ D 79 Enter Monitor n Differ 3x Weight teenager Yo test material Enter Weight More read result PKP PKS BA e 1313 19 6 8 Operating mode Percent Select Operating mode in basic settings Nr G 9 6 Befo re setti ng with with with apply target object target weight memory target weight apply Enter weight OR gt Memo commemo gt t 22 Man tare i am 2x 2 Percent Percent Percent test material next Percent Percentn 2x 2Desc ti Enter Descrip More signs spy Percent 3x Weig t Enter target weight 20 PKP_PKS BA e 1313 6 9 Operating mode Animal weighing Select Operating mode in basic settings Nr G 9 8 Befo re setti ng Animal weighing Animal weighing Set up Container Put animalin container read result Print clear With Print the fixed value will be deleted Navigation keys Function
19. ghing operation 5 7 Adjustment With an adjustment weight the weighing accuracy can be checked and re adjusted at any time Attention In the verified balances the adjustment is not possible Procedure when adjusting Observe stable environmental conditions A short warming up time of ca 15 minutes is recommended for stabilization 10 PKP PKS BA e 1313 6 Operation 6 1 Screen and operation Time Range display Network operation rechargeable battery operation Operation mode Info line Item description Operator Info fields for functions and confirmation Weight value or operating mode relative indications Weighing stoppage Zero setting display 10 Navigation keys 11 Functional and acknowledgement buttons _ 5 1313 11 6 2 How to turn on off balance Turn balance on off by using the ON OFF button 12 PKP PKS BA e 1313 6 3 Basic Settings Basic settings adjust setting the balance language Adjust Adjust Adjust 2x Language Config gt Memor oe OK Display possible weights 1 i asic settin Basic settings ES English Francais Italiano 1 A 75 Date Time Date Time TR Display 3 Set time G5 setting date G6 G7 e setting time create item NG i i it Man tare 2 tem Place calibration weight remove weight contrast G4 settings numerator activ
20. keys PKP PKS BA e 1313 21 6 10 Screen Operating mode Recipe Select Operating mode in basic settings Nr G 9 4 Basic setti ng Recipe Recipe Print Clear from recipe apply recipe daily total apps recie 2 gt Normal W m Adjust Enter Adjust Normal cen dispensing parameter s Set up Man tare 2x Recipe Y Container Wi EAT Basic settings digits Setting mod Recipe n Descript Display Enter target weight Descrip Compone Print daily tot Lirnit Dispensing to target weight tot More Differ signs digits 3x Compon YY Enter Differ Compone gt Descript Compone n Enter x Limit i Basic settings Setting mod Lerma 9 Print daily tot 2x Singlep LJ 3x2 Print Clear LUI 4 Value Subt Norm pum As Value Taring 1 i Enter ep 1 un Print total Target weights are continuously printed Descrip More digits P Neth lt 22 PKP_PKS BA e 1313 More signs im N More ompone v Y 6 11 Operating mode Grammage Select Operating mode in basic settings Nr G 9 9 Basic setti ng with with variable apply paper format factor var factor apply measuring object sample determination of the factor Example 1 m 0 6g
21. lance with foot screws until the air bubble of the water balance 15 the prescribed circle 5 3 Mains connection Power is supplied via the external mains adapter The stated voltage value must be the same as the local voltage Only use original KERN mains adapters Using other makes requires consent by KERN 5 4 Connection of peripheral devices Before connecting or disconnecting of additional devices printer PC to the data interface always disconnect the balance from the power supply With your balance only use accessories and peripheral devices by KERN as they are ideally tuned to your balance 5 5 Initial Commissioning A warming up time of 2 hours after switching on stabilizes the measuring values The accuracy of the balance depends on the local acceleration of gravity Strictly observe hints in chapter Adjustment PKP PKS BA e 1313 9 5 6 Adjustment As the acceleration value due to gravity is not the same at every location on earth each balance must be coordinated in compliance with the underlying physical weighing principle to the existing acceleration due to gravity at its place of location only if the balance has not already been adjusted to the location in the factory This adjustment process must be carried out during the initial start up after change in location and variation of surrounding temperature To receive accurate measuring values it is also recommended to adjust the balance periodically in wei
22. n of the data transfer Each data transfer is structured as follows 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 N NN N N B B B B B B P B B PB B 0 0 0 Bit Nr 21 22 23 24 25 26 E E E E CR LF N Numerator B Blank or for autotare on in zero range 0 g Blank or weighing value giving unit according to loading of the balance E E Unit CR Carriage Return Line Feed PKP PKS BA e 1313 27 8 3 Printer The serial interface RS 232 facilitates the connection of a printer The printout shows the weight in grams In counting mode either the piece number or the weight details will be printed out In percentage mode the percentage proportion or the weight details will be printed out Printout will take place after pressing the PRINT key It is possible to number each printout continuously with the help of the numerator The numerator will be reset to 000 each time the balance is turned off or the CLEAR function is actuated 8 4 Underfloor weighing Objects which are unsuitable for placement on the weighing tray due to their size or shape can be weighed with the help of the underfloor weighing facility Proceed as follows e Switch off balance e Turn over the balance and in doing so take care that the weighing plate is not loaded e Open the closing lid on the bottom of your balance e Mount the hooks for underfloor weighing balance over an opening e Suspend the goods to be weigh
23. s Our accredited DKD calibration laboratory offers fast and inexpensive adjustment for test weights and weighing balances reset to national normal weight PKP PKS BA e 1313 7 3 Basic Safety Precautions 3 1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning even if you are already familiar with KERN balances Versions in other languages are non binding translations The only binding version is the original document in German 3 2 Personnel training The appliance may only be operated and maintained by trained personnel 4 Transportation amp Storage 41 Testing upon acceptance When receiving the appliance please check packaging immediately and the appliance itself when unpacking for possible visible damage In case of visible damage have the damage verified by the messenger s signature Do not alter goods or packaging and do not remove any parts of the delivery Report the damage immediately within 24 hours in writing to the parcel service 4 2 Packaging return transport 7 gt Keep all parts of the original packaging for a possibly required return Only use original packaging for returning Prior to dispatch disconnect all cables and remove loose mobile parts Reattach possibly supplied transport securing devices 4 UU Q 5 Secure all parts such as the glass wind screen the weighing platform power unit etc against shifting and d