1. MIR RHVAS THE PRODUCTS OF CHOICE 6L Oil less Compressor 53103 Operating Instructions Please read and save these instructions before attempting to assemble install operate or maintain the product Protect yourself and others by observing all safety information Failure to comply with instructions could result in injury and or damage DESCRIPTION Oil less compressors are designed for DIY do it yourselfers for a variety of home uses and operate without oil Compressed air units contain moisture therefore ensure you install a water filter or air dryer if your application requires dry air SAFETY GUIDELINES This manual contains useful information for the safe use and maintenance of your compressor Please observe any of the safety recommendations UNPACKING After unpacking the unit carefully inspect it for any damage that may have occurred during transit If you have any concerns please contact your supplier prior to use GENERAL SAFETY INFO Air compressors and tools spray guns filters lubricators hoses etc produce and require compressed air for them to operate Ensure to 1 Read all tool manuals and be mi thoroughiv familiar with the controls and the proper use of the equipment 2 Keep visitors away and NEVER allow children in the work area 3 Wear safety glasses and use ear protection 4 Do stand operate the unit whilst handheld from the handle 5 Prior to each us
2. Motor will restart when cool Replace Replace or repair Check connections eliminate extension cork if used check circuit with voltmeter Replace motor DANGER Do not disassemble check valve with air in tank bleed tank 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or Operate compressor on its own branch circuit 2 Replace or repair DANGER Do not disassemble check valve with air in tank bleed tank Possible Cause s 1 No electrical power 2 Blown fuse 3 Breaker open 4 Thermal overload open 5 Pressure switch bad Compressor will not run 1 Defective check valve or unloaded 2 Poor contacts line voltage low Shorted or open motor winding Motor hums but cannot run or runs slowly Fuses blow circuit breaker trips repeatedly CAUTION Never use an extension cord with this product Incorrect size fuse circuit overloaded Defective check valve or unloaded Low voltage Clogged air filter Lack of proper Eliminate extension cord check with voltmeter Clean filter see Maintenance section Thermal overload protector cuts out repeatedly ventilation room temperature too high Check valve Move compressor to well ventilated area Replace Replace valve assembly DANGER Do not disassemble check valve with air in tank bleed tank malfunction Compressor valves failed Loose bolts tank not level Defective bearing on eccentric or motor shaft Cylinde
3. SS COMPRESSOR 53103 0 6 0 2 4 485 3103 1 RHVAS AIR Authoritv Director Date April 2014 Rhvas Products Leominster HR6 OQF England UK Subject to change Document Ref 6Ltr Air Compressor 53103 Product code 53103
4. e inspect the air system and electrical components for signs of 6 Compressor parts be hot even if the unit is stopped damage deterioration weakness or leakage Repair or replace defective items before using 6 A WARNING Never operate or repair in or near a flammable gas or vapor Never store flammable liquids or gases in the vicinity of the compressor 7 A CAUTION N H X 8 A WARNING Never remove or attempt to adjust the pressure release valve Ensure it is kept clean and free from any contamination 9 A DANGER Never attempt to repair or modify a tank Welding or any modification may weaken the tank resulting in damage rupture or explosion Always replace a worn or damaged tank 10 A WARNING Tanks rust from moisture build up which weakens the tank Make sure to drain tank regularly and inspect periodically for unsafe conditions such as rust formation and corrosion 11 MAIN TECHNICAL DATA 12 LOCATION It is extremely important to install the compressor in a clean well ventilated area The surrounding air temperature should not be more than 100 A minimum clearance of 18 inches between the compressor a wall or anv other obstacle is required so as not to obstruct the airflow to the unit 13 A CAUTION Never use an extension cord with this product Use additional air hose to reach your work area this is
5. r or piston ring is worn or scored 1 Tighten bolts shim tank to level position 2 Replace vibration Replace or repair as necessary Tighten Disassemble check valve assembly clean or replace Check all connections with soap and water solution and tighten Loose drain cock Check valve leaking Loose connections at pressure switch or regulator Tank pressure drops when compressor shuts off Excessive air usage compressor too small Clogged intake filter Air leaks in piping on machine or in outside system 4 Broken inlet valves Piston ring worn Decrease usage or purchase unit with higher air delivery CFM Clean or replace Replace leaking components or tighten as necessary Replace compressor valves Replace piston and cylinder Compressor runs continuously and air Output is lower than normal low discharge pressure 1 Drain tank 2 Move to area of less humidity use airline filter NOTE Water condensation is not caused by compressor malfunction Excessive moisture in 1 Excessive water in tank discharge air 3 High humidity Compressor runs continuously and safety valve opens as pressure rises Excessive starting and stopping auto start Air leaking from unloader 1 Defective pressure 1 Replace switch switch 5 Replace safety valve with genuine replacement 5 Defective safety valve part 2 Excessive _ Drain more often condensation in tank Remove and replace check valve 2 DANGERI Do no
6. t disassemble check valve with air in tank bleed tank 2 Check valve stuck in an open position on pressure switch PARTS DIAGRAM 4 PRT Z4 as PARTS LIST 6 1 Ta 90 quick coupler quick coupler pressure gauge 40 motor bracket bearing 6204 RS regulate valve three way connecter 59 60 safety valve ii ii POWER RHVAS THE PRODUCTS OF CHOICE Customer care Line 01568 620444 GUARANTEE This product has been manufactured to high qualitv standards and is guaranteed against manufacturing faults for a period of 12 months from the date of purchase Normal wear and tear including accessorv wear is not covered under the guarantee This guarantee is invalid if the compressor has been overloaded or subjected to neglect improper use or an attempted repair other than by an authorised agent This product is not sold for commercial heavy duty professional or hire use anv such uses voids anv guarantee DECLARATION OF CONFORMITV The following product is covered this declaration Manufacturers model No ZBW60 6 Rhvas Product Code 53103 Tested to EN 1012 1 1996 covering the following EU Directives EN 60204 1 2006 4 A1 2009 LVD 2006 95 EC 2006 42 Machinerv Directive The documentation required to demonstrate the above are available for inspection The CE mark was first applied in 2010 Signed AM Riga 6L OIL LE
7. to avoid power loss and possible motor damage Use of an extension cord voids the warranty 14 OPERATION a The red button on top of the pressure switch is the main ON OFF control With the button pressed down the compressor will operate and fill the tank with air Once it has reached capacitv it will automaticallv switch off In the position the compressor will automaticallv switch on and off to keep the tank filled with air To switch OFF the compressor pull the red button in an upward direction b regulator controls the amount of air pressure required Turning the regulator clockwise increases the pressure anticlockwise decreases the pressure to the required level for the tool being used c Ihe safety valve automatically releases air if the tank pressure exceeds the preset On Off Switch maximum d Ensure the compressor has had time to fill the tank and warm up prior to initial use e The tank pressure gauge shows pressure level in the tank ACAUTION The compressor is equipped with an automatic reset thermal overload protector this will shut off the motor if it becomes overheated If the thermal overload is activated turn off the compressor and unplug from the mains The motor must be allowed to cool down before start up is possible TROUBLESHOOTING CHART Svmptom Corrective Action Plugged Check fuse breaker or motor overload Replace blown fuse Reset determine cause of problem

Download Pdf Manuals

image

Related Search

Related Contents

Rosewill RPLC-200KIT  Porter-Cable PXCMLC3706056 Use and Care Manual  scala rider Qz User Guide IT  Dossier de presse - Les Subsistances  Incubatrice Mini Advance ad alto rendimento Istruzioni per l`uso Indice  Orion de Siemens, 1 MB  X Series User Manual - National Instruments    ダウンロード  Kenwood DPX-7010MD DVD Player User Manual  