1. Vermason TECHNICAL BULLETIN TB 7525 Bench Top Zero Volt loniser Installation and Operating Instructions Figure 1 Vermason 200200 Bench Top Zero Volt loniser Description The 200200 is a compact and lightweight dual steady state DC auto balancing benchtop ioniser The unit is normally placed at one end of the workbench or area to be neutralised It may also be wall mounted or mounted on a shelf The ionizer s neutralisation time will be best approximately 30 48cm to 91 44cm directly in front of the unit and will increase as the distance from the unit increases Figure 2 Area of Optimum Charge Neutralisation lonizers should be considered as a method for charge neutralisation in cases where grounding cannot be achieved Air ionization can neutralise the static charge on insulated and isolated objects by producing separate charges in the molecules of the gases of the surrounding air When a static charge is present on objects in the work environment it will be neutralised by attracting opposite polarity charges from the ionized air Note that ionization systems should not be used as a primary means of charge control on conductors or people EN 61340 5 2 paragraph 5 2 9 As with all ionizers periodic mainten ance will be needed to provide optimum performance The following list contains important points for the selection process charge neutralisa tion discharge time ion balan
2. way Made in America Status of the unit can be monitored remotely via the RS485 data ports Please contact the factory for the necessary polling utility software Operation Set the fan speed switch on the rear of the unit to the LOW MED or HI position Higher airflow will result in faster neutralisation rates Position the unit so that the maximum airflow is directed at the items or area to be neutralised Turn the unit ON When the unit is first turned on it conducts a self test The audible alarm will sound and then the LED will cycle through RED YELLOW and then GREEN The LED will remain GREEN during normal operation Balance Adjustment The 200200 is an auto balancing unit However tuning or manual adjustment can be accomplished by inserting a small screwdriver or trimmer adjustment tool into the balance adjustment hole located on the right rear of the unit To increase the output in a positive direction turn the potentiometer in a clockwise direction Conversely to increase the output in a negative direction turn the potentiometer in a counter clockwise direction Maintenance Alarms WARNING RISK OF ELECTRIC SHOCK These servicing instructions are for use by qualified personnel only To reduce the risk of electric shock do not perform any servicing of internal parts unless you are qualified to do so The input voltage may be verified or reset by removing the back case by disengaging the 3 sc
3. 050 diameter pure tungsten for improved mechanical strength and ionization stability Fuse 250 mA slow blow High Voltage Power Supply 5 5 kV DC nominal Input Power AC line power internally selectable for 220 230 VAC 50 60HZz lon Emission Steady state DC with sense feedback Mounting Bench top tilt adjust frame Ozone Less than 0 05ppm Weight 2 04 kg NOTE Unauthorized servicing or modifications to your monitor will void the product warranty and may create dangerous conditions Servicing should be performed only at the factory or by a Vermason approved technician Limited Warranty Vermason expressly warrants that for a period of one 1 year from the date of purchase Vermason Bench Top lonisers will be free of defects in material parts and workmanship labour Within the warranty period a unit will be tested repaired or replaced at Vermason s option free of charge Call Customer Service at 0044 0 1462 672005 for a Return Material Authorisation RMA and for proper shipping instructions and address Any unit under warranty should be shipped prepaid to the Vermason factory You should include a copy of your original packing slip invoice or other proof of purchase date Warranty repairs will take approximately two weeks If your unit is out of warranty Vermason will quote repair charges necessary to bring your unit to factory standards Call Customer Service at 0044 0 1462 672005 for a Retur
4. F and unplug the power cord Then remove the rear screen by disengaging the 4 screws on back After cleaning the emitter electrodes reattach the rear screen using the 4 screws Plug in the power cord and turn the unit back ON The emitter electrodes should not require replacement during the life of the unit with normal handling Replacement emitter electrodes can be ordered if necessary The best practice would be to verify the balance of the unit with a charge plate monitor after cleaning Neutralisation Decay Times The comparative efficiency of benchtop lonisers is determined by a standard test published by the ESD Association Standard 3 1 Typical positive and negative decay times from 1000 volts to 100 volts measured using this standard are shown in Figure 4 The performance of the ionizer was measured with the unit positioned as shown with the fan speed on high and without a filter Tias zaa ia ase 23a 17B 238 ee a ee ee eee ee PS FSC sls J6s 155 183 228 Figure 4 Decay time in seconds from 1000 volts to 100 volts on a 15 24cm x 15 24mm charged plate per ANSI EOS ESD S3 1 Specifications Air Flow Three speed fan 125fpm 250fpm 50 100cfm Balance 3 volt typical 5 volts maximum Temperature range 18 33 C to 26 67 C R H 15 to 65 Chassis Stainless steel Dimensions with stand 24 13cm high x 15 24cm wide x 7 874cm deep Emitter Points
5. ce product sensitivity solution to static problem environmental considera tions airflow physical dimensions EN 61340 5 2 paragraph 5 2 9 2 Installation Remove the ionizer from the carton and inspect for damage Included with the unit should be 1 Stand assembly with hardware 4 Rubber feet 1 Emitter point cleaner 1 NIST Certificate The input voltage should be set to your specification prior to shipping It can be verified or reset by referring to the Maintenance section of these instructions Attach the stand to the unit by placing the plastic spacers between the unit and the stand and securing in place using the knurled knobs If desired attach rubber feet to each corner of the bottom of the stand Press feet firmly in place Before installing the unit verify that the AC outlet is properly connected to earth ground The unit must have a good earth ground to maintain proper balance Install the unit in the desired location making sure that the airflow will not be restricted Be sure the ON OFF switch located on the rear of the unit is in the OFF position Plug the power cord into the unit and then into the appropriate AC power source This equipment has a grounding type plug that has a third grounding pin This plug will only fit into a grounding type power outlet If the plug does not fit into the outlet contact qualified personnel to install the proper outlet Do not alter the plug in any
6. n Material Authorisation RMA and proper shipping instructions and address Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of liability Electronic ionisers use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will Vermason or any seller be responsible or liable for any injury loss or damage direct or consequential arising out of the use of or the inability to use the product Before using users shall determine the suitability of the product for their intended use and users assume all risk and liability whatsoever in connection therewith UNIT C 4TH DIMENSION FOURTH AVENUE LETCHWORTH HERTS SG6 2TD UK Phone 0044 0 1462 672005 Fax 0044 0 1462 670440 e mail Service Vermason co uk Internet Vermason co uk TB 7525 Page 2 of 2 2008 Vermason
7. rews on back NOTE The AC power cord MUST always be disconnected before the unit is disassembled Input voltage is selected with the two internal jumpers as shown below Figure 3 220 Volt Jumper Setting UNIT C 4TH DIMENSION FOURTH AVENUE LETCHWORTH HERTS SG6 2TD UK Phone 0044 0 1462 672005 Fax 0044 0 1462 670440 e mail Service Vermason co uk Internet Vermason co uk TB 7525 December 2008 Page 1 of 2 2008 Vermason If the supply voltage drops from 200 Volts to below 170 Volts the unit will shut down the audible alarm will beep and the LED will blink RED The unit will automatically reset when the minimum voltage is restored Under normal conditions the ioniser will attract dirt and dust especially on the emitter electrodes To maintain optimum neutralisation efficiency and operation cleaning should be performed on a regular basis In the event of circuit failure the unit will enter shutdown mode When the unit enters shutdown mode ionisation will be stopped the LED on the front of the unit will change to a steady of RED and the audible alarm will sound continuously If the ioniser enters shutdown mode it must be turned OFF and then back ON to reset the unit NOTE The AC power cord MUST be disconnected before the unit is disassembled for maintenance The emitter electrodes should be cleaned using the alcohol cleaners included or a swab wet with Isopropyl alcohol First turn the unit OF