WRS2i Operating Instructions FINAL
Contents
1. communication with the thermostat The receiver should also be installed at least 1metre from any electronic devices such as radio TV microwave or wireless network adaptor The unit can be fitted to 1 Recessed conduit boxes 2 Surface mounting boxes 6 To connect the WRS2i receiver to a TRFi TRFPi CRFi or CRFi 230 wireless thermostat The wireless connect LED will be constant Red amp Blue once power has been applied Press the J YCH 1 Connect button on the WRS2i receiver 3 Installation The Red LED on the WRS2i will begin to flash Slacken the fastening screw on the bottom of the receiver with a philips screwdriver The receiver is hinged and can be opened 180 degrees Mount the unit as described in section 2 Wire the unit as described in section 1 Close the receiver and tighten the fastening screw Press the J Y connect button on the wireless thermostat The Red LED will turn off The thermostat is now connected to Channel 1 of the WRS2i receiver Press the J Y CH 2 Connect button on the WRS2i receiver The Blue LED on the WRS2i will begin to flash 4 Button LED description Press the J Y connect button on the wireless thermostat The Blue LED will turn off CH2 The thermostat is now connected to Channel 2 of the WRS2i receiver Manual override CH 1 connect H gt CH 2 connect 7 To disconnect the WRS2i receiver from a TRFi TRFPi CRFi or CRFi 230 wireless thermostat On the wireless ther
2. this button may be pressed Power Supply 230 Vac 50Hz Class Il appliance E to initialise the pairing process with the wireless thermostat Once Contact Rating 250 Vac 16 3 A Pollution degree 2 Resistance to pressed the Red LED will begin to flash Ambient Temp 0 50 C voltage surge 2500V as per EN 60730 CH 2 Wireless connect Once voltage has been applied this button may be pressed to initialise the pairing process with the wireless thermostat Once Internal wiring diagram for WRS2i pressed the Blue LED will begin to flash oO CH 2 CH1 L N ON ON MAINS SUPPLY CH 1 Manual override This button will manually override Channel 1 of the system on start up or if the wireless thermostat has been disconnected CH 2 Manual override This button will manually override Channel 2 of the system on start up or if the wireless thermostat has been disconnected Wireless connect indicator This Red or Blue LED will flash on receiving wireless signals If the Red LED is constantly on there is no thermostat connected to Channel 1 If the Blue LED is constantly on there is no thermostat connected to Channel 2 5 Resetting the WRS2i receiver Press the W reset button located on the front of the receiver 2 Mounting The WRS2i receiver should be wall mounted in an area within 20 metres distance of the wireless thermostat It is important that the receiver is mounted more than 1 metre away from metal objects as this will affect
3. WRS2i OE PPM 082114A WRS2i 2 Zone wireless receiver Before commencing any work on the electrical connections you must first disconnect the device from the mains eae amp wirin AN None of the 230V connections must v2 g be live until the installation has been 2 Mounting completed and the housing is closed 3 Installation Only qualified electricians or authorised 4 Button LED description service staff are permitted to open the 5 Resetting the WRS2i receiver terminal box 6 To connect the WRS2i receiver to a TRFi TRFPi CRFi or CRFi 230 wireless thermostat 7 To disconnect the WRS2i receiver to a TRFi TRFPi CRFi or CRFi 230 wireless thermostat Ensure that this wireless receiver is installed 1 Metre from any metallic object television radio or wireless internet transmitter Caution There are parts that carry mains voltage behind the cover The terminal box must not be left unsupervised when open Prevent non specialists and especially children from gaining access to it If the device is used in a way not Pri tion iti specified by the manufacturer it s Horto Operation It 1s safety might be impaired neccessary to complete all sections described below This 2 channel wireless receiver is designed to provide ON OFF Important Keep this document control for 2 zones This receiver has 230Vac contacts 1 Specifications amp wirin Sp g CH 1 Wireless connect Once voltage has been applied
4. mostat Press the button for 5 seconds dEL will appear on the display Press the Ml reser button On the WRS2i receiver Press the reset button on the front of the WRS2i Reset button gt CH 1 System ON lt _ gt CH 2 System ON CH 1 Manual override Wireless connect Red amp Blue LED The wireless thermostat is now disconnected from the WRS2i EPH Controls Ltd 4 Doughcloyne Court Doughcloyne Ind Est Wilton Cork Ireland EPH Controls Ltd Unit 14 New Barn Farm Brick Kiln Road Raunds Northants NN9 6HY sales ephcontrols com www ephcontrols com sales ephcontrols com www ephcontrols com
Download Pdf Manuals
Related Search
Related Contents
614 User`s Guide 《取扱説明書》 取付け終了保守点検 取付け開始 取り付け前に User Manual Graphica LEDC88004-6G Guide d`installation - Silex Technology America Questions relatives aux procédures administratives FARO 取扱説明書 AVeL Link Player Copyright © All rights reserved.
Failed to retrieve file