1. T ASTER OPERATING INSTRUCTIONS Models LMB230V LMB110V PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE Thank you for purchasing an Earlex Steam Wallpaper Stripper In order to obtain the best results please read the instructions before commencing any work Please also make a special note of the safety rules EARLEX LIMITED WILL ACCEPT NO RESPONSIBILITY FOR THE USE OF THIS PRODUCT IF USED FOR ANY OTHER PURPOSES THAN THOSE DETAILED HEREIN RETAIN FOR FUTURE REFERENCE U K Patent No 2 263 996 USA Patent No 5 542 021 Safety Rules Keep away from children and animals Do not pull by the mains lead or the steam hose Be careful of overhead dripping when using on overhead areas tilt the steam plate away from the face and body and regularly empty the steamplate of any collected condensation Do not leave unattended Do not point the steam plate at anyone Do not allow water or steam to enter light switches or sockets e Always use and store upright Always visually check that the hose and steam plate inlet are not blocked before attempting to use Do not strain kink or trap the hose under heavy objects Use only 4lb pressure cap as supplied It is also a safety valve NEVER BLOCK OFF THIS OUTLET NEVER remove the filler cap when unit is boiling switch off and wait for 5 minutes Before standing on the frame ensure all screws are tight and the frame is undamaged Nev
2. PS 0005 PS 0006 PS 0007 PS 0008 A PS 0019 PS 0020 PS 0021 PS 0022 PS 0023 PS 0027 PS 0028 PS 0032 PS 0036 PS 0038 PS 0042 PS 0044 PS 0045 PS 0046 PS 0048 PS 0049 PS 0053 PS 0055 PS 0057 PS 0062 PS 0064 PS 0065 PS 0066 PS 0067 PS 0068 PS 0071 PS 0072 DESCRIPTION QTY Stand Seat Frame Assy not shown 1 GOSS TUDO cii ph E Ires 1 Diagonal Tube 1 Vertical Tube Reel Support 1 Diagonal Tube Reel Support Tube Connector external 18 Tube Connector internal 16 C sk Screw Frame Joints 18 Stand Seat Moulding Steam Tank Assembly Anodised 1 Thermal Fuse O Ring for Element ieu cM DER 2 Hexagon Nut 5 6 Shakeproof Washer 4 Cable Assembly Switch to Cut out 1 Cable Assembly Switch to Element 1 Element Cover C sk Screw Tank to Frame 4 Steam Hose Assembly 1 Elbow Steam Outlet 1 Reel Steam Hose 1 Reel Mains Cable 1 End Plug for Reel Retention 2 Steam Plate Body 1 Adaptor for Hose 1 Circlip iiir ERR Rey 1 Taper Nut 000 16 Instruction Book not shown 1 Foot Moulding 4 End Frame Tube window end 1 End Frame Tube mains ends 1 Cross Tube Tank mounting punched 2 Horizontal Tube Reel Support Cross Tube Stand Seat punched 1 Clip for Steam Plate
3. Push Clip Seat Stand Retention 2 PS 0073 PS 0117 PS 0118 PS 0123 PS 0127 PS 0128 PS 0134 PS 0136 PS 0137 PS 0138 PS 0139 PS 0140 PS 0200 PS 0202 PS 0294 PS 0301 PS 0302 PS 0303 PS 0316 Elements PS 0317 PS 0318 PS 0319 PS 0321 Cross Tube Steam Plate Location 0 Ring Tank Seal Gasket Tank Window Thermostat Lock Nut M6 Protective Cover M6 Stainless Steam Pipe Glass Window 05 Glass Retaining Plate Level Indicator Ball Screw for Retaining Plate Screw for Tank Joint Steam Plate Buffer Steam Plate Swivel Joint Short Stud for Earth Connection Anti Discharge Valve not shown Switch Assy Mains with Indicator Filler Cap Assembly with Chain Heat Shield e223 2 bate ae dons i Heating Element 2750W Heating Element 2200W 2400W 230V 240V Heating Element 2900W Heating Element 1760W Tank Covers PS 0105 PS 0124 PS 0163 Tank Cover Silver Tank Cover Black Tank Cover Orange Cable Assemblies PS 0029 PS 0075 PS 0155 PS 0213 Cable Assy UK Cable Assy Europe Cable Assy 110V Cable Assy Australia c0 0Sd 1200Sd 8210Sd e z 00Sd N E S 2 on SEN ane AOLL SSLOSd SS 8z00Sd y O s D 39NVSO 910Sd MOV1d velOSd W3AT1IS S 00Sd N 2z00Sd VIVYELSNV Lz0Sd NN 9 00Sd LZ00Sd Ouf SZ00Sd NOEZ X MOSZz ZLEOSd
4. SET AOvZI NOEZ X MOOPZ MO0ZZ 8LE0Sd AOEZ X MO06Z 61 0Sd 9000Sd AOLL X MOQZL LZE0Sd 7000Sd 8i10Sd S000Sd a 9700Sd N Sv00Sd amp 9 LOSd f 5 V 80008d c NS i vs z900Sd g NN anes e al Zv00Sd p X Ag amp Pa x Z l0Sd d S900Sd a SQ Pd Sy 810Sd y iG d p s di 6900Sd 0 08d id 600Sd So b 8600Sd vv00Sd 8v00Sd NN c0c0Sd 19008d L 000Sd e N S 000Sd P d 0020Sd v E000Sd velLOSd 9v00Sd 2000Sd c400Sd Mains connection 230V UK only The stripper is supplied fitted with a 13 amp plug top and fuse If a replacement fuse is required this must be rated at 13 amps If in doubt consult an electrician WARNING THIS APPLIANCE MUST BE EARTHED For your total protection it is recommended that a residual current circuit breaker RCCB should be used in conjunction with the stripper Min 15 amp Max 20 amp If any electrical component is damaged or faulty it must be replaced by the manufacturer or its appointed service agent or a similarly qualified person in order to avoid hazard As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue m
5. ed by their subsequent use It is the responsibility of the user to ensure that surfaces to be treated cleaned or stripped are suitable for steam This guarantee does not affect your statutory rights In the event of a fault occuring please contact our helpline before returning the unit to our Service Department at the address below together with a copy of your purchase receipt All repairs will be dealt with speedily If the guarantee card is not returned within 14 days from the date of purchase the guarantee is limited to date of wr product manufacture Earlex Earlex Limited Moorfield Road Slyfield Industrial Estate Guildford Surrey GU1 1RU UK Tel 01483 454666 Fax 01483 454548 Email enquiries earlex co uk Website www earlex co uk Earlex Ltd 2004 PS0057 03 04
6. er use outside when raining Main Features The Earlex SteamMaster is a professional fast action steam wallpaper stripper It has many added features e Each tank is individually pressure tested e Storage spools for the hose and the mains lead e Neon mains On Off switch e Patented stand to enable user to reach the top of the wall e Cooler running steam hose Caution Check the state of your plaster before starting work Steam can loosen weak porous or poorly bonded plaster which also loosens readily if cracked holed or if steam plate is held in one position for too long after the paper is e Always disconnect power supply when filling the machine or when not in use e Do not use any caustic cleaners on the tank e Do not allow to boil dry Do not overfill the reservoir DO NOT USE ADDITIVES e Never detach the hose whilst the unit is switched on e The tank becomes hot in use Do not touch Only move with the carrying frame Steam is produced at 100 C Wear protective clothing and gloves when operating this stripper When standing on the stripper always remain within the confines of the step and do not over reach e DO NOT USE THIS STRIPPER FOR ANY OTHER PURPOSES THAN DETAILED IN THESE INSTRUCTIONS Under no cirumstances should you attempt to repair a unit unless qualified and authorised to do so Use only genuine Earlex replacement parts e Maximum weight for standing on t
7. he unit is 127 kg 20 stone and no more than 1 person at a time soaked Weak plaster can normally be detected by tapping a few areas of the wall A hollow sound indicates that you should proceed only with extreme care stopping immediately if you hear a cracking sound or plaster starts to break loose The steam stripper is safe for drywall plaster board surfaces but whatever the material it is always wise to check a small area before starting work properly Protect your home The heat generated by the boiler unit can mark carpets soft furnishings table tops cabinets etc Dust sheets or newspapers are not suitable heat protectors for delicate surfaces Preparation To achieve fastest paper removal always gently score the areas to be stripped With heavily embossed vinyl coated or painted papers this is essential Either use a proprietary perforator tool or alternatively score the paper with the edge of a wall scraper in a criss cross pattern with 150mm 6 inch spacing As with all decorating work be sure to protect carpets and furniture with covers Operation STEAM IS HOT The SteamMaster is designed for safe fast removal of wallpaper but you must be aware that steam is produced at 100 C so be careful wear protective clothing and protect your hands with heat resistant gloves or mitts Place the unit on a flat surface near to the area to be stripped Remove the steam plate FULLY UNCOIL the hose and main
8. nit Fails to Boil e The thermal cut out has operated Switch off allow to cool refill with water then switch on again e Check the fuse in the plug 230V unit only e f using an extension lead check that the thermal re set button on the extension lead has not tripped out Check that the extension lead is rated at a minimum of 13 amps 230V unit only If the unit still will not operate return the unit to the dealer or authorised agent to check the thermal fuse link and element ONLY QUALIFIED ELECTRICIANS SHOULD UNDERTAKE THIS WORK Unit keeps cutting out e Check that water is above minimum level e Check that the extension lead is rated at 13 amps minimum and fully unwound 230V unit only e Check that no additives have been used Steam escaping from Filler Cap e Check for blockages in hose or steam plate e Clean seating around cap area Descaling We recommend that the tank is cleaned every three months using proprietary descaling products used as per the manufacturers instructions Spare Parts The full range of spare parts is available from Earlex Despatch is available same day by first class post to Companies with credit facilities or for payment by credit card IF YOU REQUIRE ANY FURTHER ASSISTANCE PLEASE CALL OUR HELPLINE ON 01483 454666 Monday Friday 08 30 18 00 Excluding Bank Holidays Spare Parts List and Diagram PART NO PS 0001 PS 0003 1 PS 0003 2 PS 0003 4 PS 0003 5 PS 0004
9. not re set allow a further cooling period When you have finished using the unit allow any remaining water to cool and then empty the unit We recommend flushing the tank out with clean water before storing NEVER LEAVE WATER IN THE UNIT WHILST BEING STORED Storage Spools These are designed for easy and compact storage The mains lead and hose must be fully unwound before commencing to operate the unit To recoil the mains lead Fit the plug into the socket on the side of the spool and then wind the mains lead onto the spool To recoil the hose Place the steam plate end of the hose into the side aperture of the spool and then wind the hose onto the spool Storage Steam Plate The handle of the steam plate is shaped to locate between the frame and the tank Slide the plate into position with the handle against the tank and the thread towards the base Filler Cap To fit screw onto the filler neck hand tight Do not overtighten To remove ensure unit is switched off and has stopped boiling Wait for 5 minutes Slowly unscrew the cap any remaining trapped steam will be released from beneath cap Caution steam is very hot wear a glove and keep face clear Refill to the level indicator as before and follow above instructions DANGER FROM STEAM Other Uses The SteamMaster can also be used to e Remove Artex e Lift stuck down vinyl tiles e Sterilise soil e Kill garden weeds TROUBLE SHOOTING U
10. s lead Connect the thread on the steam plate to the end of the hose This only needs to be hand tight DO NOT OVERTIGHTEN If the steam plate is fitted with a metal swivel joint tighten hose nut to thread using two spanners The plate can remain permanently attached to the hose thereafter To fill the unit remove the filler cap and fill to the maximum water level as shown on the glass panel at the end of the tank This must be clean water preferably hot DO NOT USE ADDITIVES DO NOT OVERFILL Replace the filler cap connect the mains lead from the unit to the socket and switch on The mains switch on the unit has a neon light and will light when the unit is on It will take between 10 and 20 minutes for the 230V unit or 25 35 minutes for the 110V unit to start producing steam depending on the temperature of the water used DO NOT LEAVE UNATTENDED Once steam is being produced at the steam plate you are ready to commence operation Prior to the steam being produced a small amount of bubbling will occur at the steam plate WARNING Beware of hot water discharge prior to steam emission When the steam has been produced lift the steam plate above the level of the tank outlet to allow condensed steam to run back down the hose and into the tank If you are right handed hold the steam plate in your left hand and place flat against the wall where you wish to commence removing Leave the plate against the wall for approxima
11. tely 10 seconds If you are left handed you may find it easier to operate with the other hand Move the steam plate to the section immediately next to where you have just been working and use a wallpaper scraper to remove the section that has just been steamed By working in this way you should be able to remove paper continually You may have to leave the plate against the wall for longer periods with some papers or re steam if not completely removed The 230V unit will operate for approximately 1 1 2 hrs and the 110V unit will operate for approximately 3 1 4 hrs before requiring refilling The water level is shown through the glass level indicator and should not be allowed to fall below minimum Switch the unit off when this level has been reached If you require further use of the steamer ensure unit is switched off and has stopped boiling Wait for 5 minutes Slowly unscrew the cap any remaining trapped steam will be released from beneath cap Caution steam is very hot wear a glove and keep face clear Refill to the level indicator as before and follow above instructions YOU MUST NEVER ALLOW THE UNIT TO BOIL DRY There is a safety thermal cut out device fitted to the unit If the unit is allowed to boil dry this will operate and prevent further use Switch the unit off and allow it to cool for at least 5 minutes refill with water and then switch on again the thermal cut out should automatically re set If this has
12. ust be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red EC Declaration of Conformity earth green amp yellow ERKEEEEEI live brown L o neutral blue Mains connection 110V UK only The stripper is fitted with a 16 amp industrial plug for insertion into a suitable transformer or generator supplying 110V a c outlet If this mains cable becomes damaged it should be replaced with our Part No PS0155 Extension Leads 230V If you are using an extension lead it must be rated at a minimum of 13 amps and fully unwound Do not operate with a lead rated at less than 13 amps as this will cause premature failure of the element which is not covered by guarantee We declare that the units LMB conform to 73 23 EEC BSEN60335 2 15 amp 89 336 EEC EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 ha Tim Hopper Technical Director GUARANTEE This product is guaranteed for a period of 2 years for ordinary use and 6 months for hire purposes or where the unit is lent to other users The tank is guaranteed against corrosion for 3 years The guarantee is against faulty materials or workmanship Whilst every possible care is taken by Earlex to ensure that our products leave the factory in good working order Earlex cannot under any circumstances accept liability for problems or damage caus