1. WF21 DK INSTALLATIONS OG BRUGSVEJLEDNING UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS D INSTALLATIONS UND GEBRAUCHSANWEISUNG FR NOTICE D INSTALLATION ET D UTILISATION WESTFIRE DANSK INGENI RKUNST UK WESTFIRE WF21 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS WESTFIRE WF21 This manual refers to the stove type listed below which has been tested in accordance with EN 13240 Congratulations on your purchase of a new wood burning stove from Westfire ApS Please read this manual care fully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing and using fireplaces and wood burning stoves please see the relevant brochure on building regulations that applies to the country in which WF 21 has been approved as well as the relevant brochure on the correct use of wood burning stoves available from your local stove supplier or your chimney sweep INSTALLATION GUIDELINES You must comply with all applicable national and local building regulations when installing your wood burning stove Please see the applicable regulations for full details The regulations state that flammable floors beneath closed hearths must be covered by a fire proof material that extends a minimum
2. left until the handle firmly closes WOOD FUEL IMPORTANT Never use toxic wood such as chipboard impregnated painted wood or finished prepared woods such as pallet Good quality wood is the most important factor in your stove working efficiently and cleanly Always use dry firewood The dryness of the firewood plays an important role since the use of wet wood results in poor fuel economy and may cause a tarry sooty film on the internals of the stove Newly cut wood contains 60 70 water making it totally unsuitable for use as firewood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood SOLID SMOKELESS FUELS Westfire stoves are only CE EN HETAS tested and approved for wood It is possible however to use other types of fuel with due care When using coal smokeless fuel you must use a coal insert and a mix of 80 wood 20 coal Please note coal reduces the lifetime of the stove and the chimney considerably PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS STOVE ITS USE WILL INVALIDATE THE GUARANTEE Overnight burning Westfire stoves are wood stoves wood burns more efficiently and cleanly if is burnt hotter Westfire do not recom mend that their stoves are burnt overnight for this reason As a night time regime we recommend that the fire is loaded when hot and burnt for five minutes with the secondary air valve fully open until the new wood has taken and is burning then close the seco
3. NS3059 partikelmaling Stevmaling efter DIN plus Zertifizierungsprogramm PROVNINGSRESULTATER Pr vning ved nominel ydelse iht EN 13240 afsnit A4 7 er foretaget med br nde og f lgende resultater blev opn et Nominel ydelse 5 0 KW CO emission henf rt til 13 O2 0 19 Virkningsgrad 74 R ggastemperatur 248 C Sikkerhedsprovning er foretaget iht EN 13240 afsnit A4 9 2 2 Ved f lgende afstande til br ndbart materiale er temperaturen mindre end 65 C over rumtemperaturen Afstand til sidev g 300 mm Afstand til bagv g 175 mm Partikelmaling iht NS 3058 og eller stovm ling iht metode DIN plus Partikelemission efter NS 3058 5 80 g kg t rstof middelv rdi maks 10 Partikelemission efter NS 3058 9 53 g kg t rstof maksimalt maks 20 Stovemission efter metode DIN plus mg Nm ved 13 O maks 75 Bem rk venligst at de oplyste v rdier er et uddrag af provningsrapporten For yderligere oplysninger henvises til provningsrapporten se nummer ovenfor Teknologisk Institut er notificeret provningsorgan med ID nr 1235 Arhus den 4 april 2008 Skorstensfejerpategning 14136 Mediegruppen Reklamebureau Max Bjerru Teknikumingeni r P baggrund af ovenn vnte partikelemission attesteres det hermed at fyringsanl gget opfylder emissionskravene i bilag 1 til Bekendtg relse nr 1432 af 11 12 2007 vedr regulering af luftforurening fra br ndeovne og br ndekedler samt visse andre faste anl g til energip
4. approved as well as the relevant documents on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep These instructions cover the basic principles to ensure the satisfactory installation of the UNIQ 21 wood stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recommen dations given in British Standards BS 8303 BS 6461 and BS 7566 as an alternative means to achieve an equiva lent level of performance to that obtained following the guidance given in Approved Document J HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipm
5. of 30 cm in front of the stove opening and a minimum of 15 cm on either side The fire proof material may be e g a steel plate a glass plate tiles or artificial slate The floor on which the wood burning stove is to be installed must be sufficiently strong to carry the weight of the stove The minimum distances to flammable materials are specified on the EN 13240 plaque on the back of the stove O ORE ERE SOE RON There are no rules regarding the minimum distance to non flammable walls but we recommend leaving a gap of at least 10 cm behind the stove to make cleaning easier Combustion requires air and fresh air must therefore be available in the room in which the stove is installed Air inlets must be positioned in such a way that they cannot be blocked An air inlet may be a vent the vent must be open and the capacity of the vent sufficient when the stove is lit or a fresh air system linked to the stove All wood burning stoves from Westfire are fitted with heat deflection baffles which ensure the maximum efficiency and the clean burn of the stove These baffles should not be removed CHIMNEY CONNECTION The chimney to which the stove is connected must have a diameter of at least 15 cm which corresponds to an area of 175 cm The chimney must be sufficiently long to provide a good chimney draft and to ensure that the smoke from the stove will not cause a nuisance The chimney must be fitted with an easily accessible cleaning hatc
6. wet Smoke or odour Weak chimney draft check for blockages in the flue pipe chimney and check the height of the chimney in relation to the surroundings Soot in the chimney The firewood may be too wet or the intake of secondary air may be insufficient GUARANTEE Your new stove is covered by a five year guarantee against manufacturing defects Your receipt documents the date of purchase The guarantee does not cover damage caused by faulty operation such as overheating or the stove being incorrectly connected or damage which occurs as a result of external physical force The guarantee does not cover damage to replaceable parts transport costs associated with repairs under warranty or the installation dismantling of the stove in connection with repairs under warranty Warning Any unauthorised modification of the appliance is forbidden Only replacement parts recommended by Westfire ApS should be used for repairs CO WESTFIRE WF21 U K VERMICULITE FIRE BRICK INSTALLATION SEQUENCE WESTFIRE UNIQ 21 Installation procedure Right inner top baffle brick 2 positioned on secondary air pipe amp side supports 1 Left Inner Top Baffle Brick 2 Right Inner Top Baffle Brick 3 Rear Brick 4 Left Base Brick 5 Right Base Brick 6 Left Angled Side Brick 7 Right Angled Side Brick 8 Left Side Brick 9 Right Side Brick 10 Top Baffle Brick Left inner top baffle bricks 1 positioned on secondary air pipe amp side
7. will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Build ing Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross section may be too large i e more than 160 mm x 160 mm Remedial action should be taken if required seeking expert advice if necessary If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after instal lation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used These chimneys must be fitted in accordance with the manufacturer s instructions and Building Regulations 11 UK WESTFIRE WF21 A single wall metal fluepipe is suitable for connecting the stove to the chimney
8. but is not suitable for using for the complete chimney The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove Any bend in the chimney or connecting fluepipe should not exceed 45 90 bends should not be used If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at least 20 of the total cross sectional area of the flue or fluepipe Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue pipe Distance to Combustible materials Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance on the separation of combustible material given in Building Regulations Approved Docu ment J and also in these stove instructions Distance to flammable material furniture Hearth The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not inde pendently supported The Westfire WF UNIQ 21 wood stove has been te
9. ent Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury WESTFIRE UNIQ 21 WOODSTOVE UNIQ 21 dimensions 10 WESTFIRE WF21 U K STOVE PERFORMANCE amp TESTING Westfire WF UNIQ 21 has been approved in accordance with EN 13240 PREPARATORY WORK AND SAFETY CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room CHIMNEY Chimney Connection Flue Diameter 150mm 175cm IMPORTANT When installing the WF UNIQ 21 wood stove remove steel retaining bar across top flue exit Remove bolts and take out bar replace and bolt cast onto collar In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught so as to clear the products of combustion and prevent smoke problems into the room Minimum draft WF UNIQ 21 stove has been tested with a draft of 12 Pa Maximum draft 25 Pa Flue gas flow 4 2 g sec Flue gas temperature 240 C approximately 12 Pa NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in BS 5854 1980 may be used as the basis for deciding whether a particular chimney design
10. ever use mentholated spirit petrol or other flammable liquids To light the stove 1 Place a few smaller pieces of dry wood kindling in the stove on top of the non toxic firelighters 2 Fully pull open the air slider secondary air 3 Light the firelighters and push the door closed until it is 1 2cm open do not lock the door shut 4 Once the fire has caught add two pieces of wood measuring approx 20cm with a combined weight of approx 1 2kg and again push the door closed until it is 1 2cm open do not lock the door shut 5 After approximately 5 minutes when the fire is burning brightly shut the door leave air slider fully open 6 After approximately another 7 minutes close the air slider by 10 90 open At nominal heat output expect to refuel your stove approximately once an hour WF 21 is designed for intermittent combustion wood must be added often and the stove is not designed for 24 hour use WF 21 is equipped with a control valve for secondary air designed to ensure a plentiful supply of oxygen during firing When lit the stove will get very hot and due care must therefore be exercised Please use a glove when operat ing levers and dampers In the event of a chimney fire Close the air damper and the stove door and call 999 or your local fire depart ment BASIC POSITIONS OF DAMPERS DURING OPERATION ai 90 open You will need to become familiar with your stove in order to be able to regulate the seconda
11. h WF 21 has been approved in accordance with EN 13240 The nominal heat output of this stove is 5 kW WF 21 has a test weight of 81 kg Minimum draft The stove has been tested with a draft of 12 Pa Max draft 25 Pa Flue gas flow 6 3 g sec Flue gas temperature 248 C WF 21 is fitted with both a top and rear outlet The chimney may be equipped with a regulation damper in the flue pipe to allow the draft to be regulated on windy days The damper must not be able to close fully and must have a clearance of at least 20 cm of the total clear opening of the pipe WESTFIRE WF21 U K Other types of dampers may also be used such as allowing air to enter the chimney by bypassing the stove More than 1 appliance on a flue system is not allowed in the UK under any circumstance OPERATING INSTRUCTIONS The heat resistant paint on the stove will harden the first time you light up the appliance This process produces a good deal of smoke and odour and the room should therefore be well ventilated The stove door should be kept open during the first couple of firings and only closed once the stove has cooled down to prevent the packing cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened the stove door must be kept closed except when lighting the stove adding firewood or removing ash in order to prevent flue gas from escaping Firelighters should ideally used when lighting the stove N
12. mney given in the instruction booklet Commissioning and handover Ensure loose parts are fitted in accordance with the instructions page 15 amp 16 Vermiculite fire brick installation sequence before handover Operation of primary and secondary air controls must be fully explained On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out when a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and emitted safely to atmosphere Do not run at full output for at least 24 hours On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use a firequard to BS 6539 in the presence of children aged and or infirm persons Operating your stove WF UNIQ 21 Initial lighting The heat resistant paint on your stove will cure and harden the first time you light your appliance The curing process produces a good deal of smoke and odour it is therefore important that the first time you light your stove the room should be well ventilated During the process it is important to open and close the st
13. ndary air valve to its operational position On returning to the stove in the morning the fire will have burn out reload with some paper or firelighter and some kindling and open all the values fully open and the stove will relight quickly Beware as the ash bed will have hot embers Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use Maintenance UNIQ 21 wood stove needs to have the ash removed from the stove at regular intervals Make sure the stove is completely cold before cleaning out ash embers can remain hot for over 24 hours To clean the outside of the stove use a dry cloth Annual service The inside of the stove should be serviced cleaned once a year To clean the inside remove all ash soot and tar residue from the combustion chamber Remove insulated chamber panels and baffle dirt and soot will collect 15 MU Ja KW Li NSS NSIS PMA DANAK TEKNOLOGISK hk Ne IN S TIT U T TEST Reg nr 300 Teknologiparken Kongsvang All 29 DK 8000 A TEKNOLOGISK INSTITUT Phone 45 72 20 10 00 Akkrediteret provningsorgan DANAK akkreditering nr 300 aks 1220 1049 Info teknologisk dk PROVNINGSATTEST Uddrag af rapport nr 300 ELAB 1164 EN og 300 ELAB 1164 NS Emne Br ndeovn Westfire Type WF 21 Rekvirent Westfire ApS T mrervej 3 6800 Varde DK Procedure X Pr vning efter DS EN13240 A2 2004 X Pr vning efter NS3058 1 NS 3058 2 og
14. ove door periodi cally every 30mins during the first couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the Heat resistant paint has hardened the stove door must be kept closed except when lighting the stove adding firewood or removing ash in order to prevent flue gas from escaping Lighting your appliance Quality Firelighters should be used when lighting the stove Never use mentholated spirit petrol or other flam mable liquids Lighting your stove with fire lighters will be more reliable and easier than paper To light your stove 1 Place a few smaller pieces of dry wood kindling in the stove on top of the non toxic firelighters 2 Fully pull open the air slider secondary air 3 Light the firelighters and push door to closed position but do not close latch door should remain open approximately 1cm 4 Once the fire has caught add two pieces of wood measuring approx 20cm with a combined weight of approx 1 4kg and close the door 5 After approximately 10 15 minutes when the fire is burning brightly and hot closed the door fully If the fire falters and dies down unlatch door for another 5 10 mins 6 After approximately another 10 minutes close the secondary air slider by 10 for the stove to burn cleanly plenty of secondary air is needed do not be tempted to shut the fire down too early as this may cause smoke At nominal heat output expect to refuel you
15. r stove approximately once an hour WF UNIQ 21 stoves are all equipped with a control valve for secondary air designed to ensure a plentiful supply of oxygen during firing When lit the stove will get very hot and due care must therefore be exercised Please use a glove when operating levers and dampers RE FUELING To re fuel in the cleanest way Before refuelling open secondary air value fully and leave for 5 minutes Open door gently add two pieces of wood measuring approx 20cm with a combined weight of approx 1 4kg and close the door Leave the air values open for 10 minutes to allow the fire to reach a good temperature Then close secondary air valve to 90 open In the event of a chimney fire Close the air damper and the stove door and call 999 or your local fire department If your stove is over heating close all dampers and door must be closed and left until the stove has return to nominal temperatures 14 WESTFIRE WF21 U K Pre heated Tertiarv air 01 Handle Turn awav from glass to open Secondary air lever push in for fully closed pull out for fully open CONTROLS on WESTFIRE UNIQ 21 When lighting stove unlatch door 1 cm to allow extra air into stove Door operation When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from possible heat The handle twists right away from the fire When shutting the door push the door closed and twist
16. roduktion Der tages forbehold for trykfejl WESTFIRE 2009 T MRERVEJ 3 DK 6800 VARDE TELEFON 445 7522 5352 FAX 45 7522 1352 WWW WESTFIRE DK E MAIL INFO WESTFIRE DK
17. ry air intake correctly as factors such as the qualitv and height of vour chimnev the qualitv of vour fuel and the external conditions play a large role It is easy to see whether the stove is functioning correctly however Incomplete combustion may lead to a build up of hard shinv soot on the inside of your stove This is prevented by the introduction of additional secondary air Itis important to check the draft conditions before lighting vour stove This mav be done for instance bv crum pling a piece of newspaper placing it in the combustion chamber and lighting it The draft conditions are good if the smoke is drawn awav through the chimnev FUEL Never use toxic wood such as chipboard impregnated or painted wood Alwavs use drv firewood The drvness of the fire wood plavs an important role since the use of wet wood results in poor fuel economv and mav cause tarrv soot to form UK WESTFIRE WF21 Newly cut wood contains 60 70 water making it totally unsuitable for use as firewood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood MAINTENANCE Ash must be removed from the stove at regular intervals The stove must be completely cold before being cleaned The outside should be cleaned using a dry cloth The inside of the stove should be cleaned once a year To clean the inside remove all ash soot and tar residue from the combustion chamber The smoke plate should be removed a
18. s dirt and soot will collect behind it The packing cord in the door will wear over time and should therefore be checked The stove the flue pipe connection and the chimney should be checked regularly by a qualified engineer The chimney should also be checked for blockages before relighting the stove if it has not been used for an extended period of time The lacquer may wear thin in exposed places due to overheating This and other lacquer damage may be repaired using a special senotherm lacquer spray available at all stove outlets Ash must be stored in a non combustible container and must not be mixed with other combustible waste The combustion chamber is lined with Skamol These panels will wear over time and will therefore need replac ing The same is true for the smoke plate A Skamol panel may crack if hit too hard by a piece of firewood This has no effect on the function of the stove this is not the case with the smoke plate The Skamol panels will only need to be replaced once they become very worn and are no longer whole or if they crack in several places The air damper and the stove door must be closed in the event of overheating OPERATING PROBLEMS Soot forms on the window The firewood may be too wet or the intake of secondary air may be insufficient The wood burns too quickly The chimney draft may be too strong or there may be a leak near the door of the stove The stove fails to heat fully The firewood may be too
19. sted and is suitable to be installed on a 12mm non combustible plate such as Westfire 12mm glass plates or 20mm slate plates Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Docu ment J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to the hearth should comply with the guidance on the separation of combustible material given in Building Regula tions Approved Document J and also in these stove instructions If the stove is to be installed on a wooden floor it must be covered with a non combustible material at least 12mm thick in accordance with Building Regulations Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber Combustion air supply In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air This is particularly necessary if the room is double glazed or a flue draught stabiliser is operating in the same room as the appliance The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Air inlets must be positioned in such a way that they cannot be blocked An air inlet ma
20. supports Right inner top baffle brick 2 positioned on secondary air pipe amp side supports Top baffle bricks 2 amp 3 fitted Rear brick 3 line up tertiary air holes Front face of brick has smaller surface area Left amp right base bricks 4 amp 5 fitted with metal base brick tensioner positioned at side Left and right angled side bricks 6 amp 7 fitted Left and right angled side bricks 6 amp 7 fitted Left and right side bricks 8 amp 9 fitted Left and right side bricks 8 amp 9 fitted Top baffle brick 10 smallest straight edge resting on top edge of rear brick fitted and supported with two side pins UK WESTFIRE WF21 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS WESTFIRE WF UNIQ21 WF UNIQ21 WALL HUNG WF UNIQ21 PEDESTAL This manual refers to the stove type listed above which has been tested in accordance with EN 13240 Congratulations on your purchase of a new wood burning stove from Westfire ApS Please read this manual care fully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems Please note that all local regulations including those referring to national and European Standards need to be complied with when installing this appliance For further information on installing and using fireplaces and wood burning stoves please see the relevant build ing regulations that apply to the country in which UNIQ 21 has been
21. y be a vent the vent must be open and the capacity of the vent sufficient when the stove is lit or a fresh air system linked to the stove WESTFIRE WF21 U K WF UNIQ 21 stoves are available with a closed air supplv collar additional item this enables the stove to take combustion air directiv from outside with a 100 mm pipe from the stove There are no European rules regarding the minimum distance to non flammable walls Westfire recommend leav ing a gap of at least 10 cm behind and to sides of stove WF 21 Dimensions 155mm 85mm JT WE UNIQ 21 155mm IL 610mm 73mm Fl WF UNIQ 21 WALL HUNG Westfire Insulated chambers 80mm 80mm 696mm 208mm 8mm hole x 8 208mm Steel wall bolts must be used 35mm 190mm WF 21 WALL HUNG BRACKET Top of bracket is 18mm below top of stove The Westfire WF UNIQ 21 wood burning stove is lined with heat deflection panels and baffles these panels are designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove These baffles should not be removed apart from for cleaning the stove Any defective panels should be replaced Connection to chimney 13 UK WESTFIRE WF21 Westfire WF UNIQ 21 wood stoves have both rear and top flue connector that allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for Connection to chi

Download Pdf Manuals

image

Related Search

Related Contents

User Manual - Sütron electronic GmbH  Philips SJM2110 6 ft A/5-Pin mini B connectors USB MP3 cable      AX80 取扱説明書 No.6 マルチコントロールボックス  Manual - Index of  Lexicon 212 Car Amplifier User Manual  5 万女射線を照射する医療機器の取扱説明書 には、 照射する放射腺の  USER`S MANUAL . . . . . . . . . . . . .3  Avaya 1600 Series IP Deskphones Application Note  