1. output 1 Code 4 8 digits Enter NEW MASTER programming code 4 8 digits for all multi codes User number 00 99 EAA EA e Lal Code 4 8 digits Enter up to 10 user codes for relay output 2 User number 0 9 Programming Relay output modes Output 1 in momentary mode Can be 1 3 i i digits 1 999 seconds Output 1 in latching or toggle mode Output 2 in momentary mode Can be 1 3 i i digits 1 999 seconds Output 2 in latching or toggle mode Restore Defaults 1 Disconnect the power supply 2 Put the DAP jumper in the ON position 3 Re connect the power supply The buzzer will be activated 4 Put the DAP jumper back in the OFF position 5 The keypad is now in programming mode ready to receive data Additional keypad information EG IN EGRESS INPUT A Normally Open N O input terminal refers to ground with the help of a normally open button to activate the Output 1 for the same time period as the user code Egress button is usually put inside the house near the door More than one egress buttons can be connected in parallel to the terminal Leave this terminal open if it is not used KEY ACT KEYPAD ACTIVE OUTPUT An NPN transistor open collector output It switches to ground for 10 seconds on each key touching This can be used to turn on lights CCTV camera or buzzer to notify a guard The rating of this output is lc max 100mA sink Vc max 24VDC DU OUT DURESS OUTPUT
2. An NPN transistor open collector output It switches to ground after the Duress Code is entered Use it to trigger an alarm zone or turn on a buzzer to notify a guard Ic max 100mA sink Vc max 24VDC Fault finding amp FAQs Q The unit will not power up No LEDs on A Check power supply voltage is within 11 5V 12 5V DC Q The unit powers up but there is a bleeping from the door station A This means the unit is not able to detect the network for some reason Check the SIM card is activated and has calling credit Power off the unit remove the SIM and check it in a mobile phone to verify it can make a call Check the SIM does not ask for a PIN code when put in a phone If it does then disable the PIN code request Check the SIM is a standard GSM SIM not 3G or 4G only SIM If you are unsure contact your SIM card provider to verify Frequency of operation should be any one of the international quad band standards 850 900 1800 1900 MHz Check the reception is good Poor reception is not sufficient Check the antenna has been mounted as high as possible not near large metal objects or wet green shrubs etc Check the antenna connection Visually inspect that the centre pin inside the antenna is intact and has not been pushed back inside the fitting Q The unit calls the first number but there is not enough time to answer before it diverts to the next number A Increase the no answer time as per programming
3. GSM 3AB amp ABK V2 5 Installation Installation Manual 1 Before you install this equipment please read this full manual 2 Ensure that there is good network reception at the location where it will be installed Remove Call Button Optional keypad module Hinge front door Speech Unit 4 5 feet Pillar Side View Wiring r Power LED GSM LED CPU LED For illumination connect to back box lighting connectors Output Exit button Connections SK model OUT1 OUT2 Antenna connector Finger tighten only SIM card 3 Remove the top two security screws as shown Do NOT remove the bottom screws The front door will hinge downwards to allow access for mounting holes and connection terminals Note The protective film on the front of the intercom should not be removed until fully installed 4 Use appropriate wall fixings 8 10mm anchors 75mm deep with M5 screw are recommended as a minimum 5 Install the antenna as high as possible on the top of the pillar to ensure line of sight in all directions for best possible reception Keep antenna high as possible and above electronics audio equipment to eliminate interference 6 Carefully follow the wiring instructions Additional wiring suggestions for electric strike lock and magnetic lock are shown overleaf holder SIM card 7 Register your SIM card with the n
4. MS Commands Press to open OR Press to hold open and Press 1 to release again Only some gate systems allow hold open control depending on manufacturer Default pass code 5678 is shown in all examples This may have been changed by your installer Trigger Gate Latch or hold Unlatch Door open gate door gate door SEND SMS SEND SMS SEND SMS 33 56 8 34 56 8 35 56 8 ul a ieee e HOLD OPEN FEATURE OR PARTY MODE Some gate systems allow hold open control depending on 2 3 manufacturer Send the following SMS commands to control the gates Calling the intercom options Dialling MY GATE u END n Option 1 If your number is saved inside the intercom memory just dial it and it will activate the door or gate without answering your call The intercom will end the call for you If limit switch fitted Check stored check gate status numbers SEND SMS SEND SMS DOH 21 Reply will indicate O dial out number opened or closed Dial in number for caller ID access 33 5678 1P F S 6 aa e O Option 2 If your number is not saved in the intercom memory it will answer the call Enter the code on your telephone keypad to activate the door or gate default code shown
5. etwork and check it works in a mobile phone first If you are using a Pre Optional pay or Pay amp Go SIM it will input a need topped up first Your from gate SIM should be GSM compatible 8 Ensure the power is OFF before inserting the SIM card 9 Carefully slide the SIM holder in the OPEN direction Advanced insert the SIM and slide in the KeyPad CLOSED direction to lock it in place Do NOT Force or use a screwdriver 10 After a final check of wiring switch on the power 11 Allow 20 30 seconds for the unit to boot up and detect the network Once successful connection has been made the unit will sound a confirmation tone and the status LED will begin flashing If there is a fault or problem the unit will emit a series of bleeps or warning tones If this occurs check 1 That the SIM card has been activated and has credit 2 That the SIM card does not require a PIN code disable this in a phone 3 That the SIM card can make and received a call on a phone 4 Switch off power remove and reseat the SIM card and try again Programming Programming is best done by SMS text It can also be done by DTMF froma normal telephone 1 First check reception Send the following SMS to the unit 20 The unit should send a reply SIGNAL LEVEL where will be a number between 1 and 4 For successful operation the reception should be at least 3 or 4 If it is lower the unit will experience audio quality pr
6. hone numbers for caller ID access N 999 Restore defaults N Check stored numbers Note no pass code needed for this N command O dial out number Dial in number Remember to begin each new SMS with pass code 12 1234 Note DTMF Programming is done by calling the unit amp entering the pass code first then after a long single confirm tone commands can be entered A fault is indicated by 3 short bleeps A A A Keypad Programming only ABK models The amber LED indicates standby mode flashing or programming mode ON Green LED indicates output 1 active Red LED indicates output 2 active Enter Programming mode o Lo Lo fo Choosing single user mode or multi user The unit is now in programming mode Amber LED will remain ON 0000 is default programmers code Note Pressing again will exit programming mode For most installations it is sufficient to add a single keypad code for all users However you can program up to 99 codes for relay 1 and 10 codes for relay 2 To do this you need to first put the unit into multi mode 9 0 0 Set to SINGLE USER mode and refresh system 8 Le Lo 1 a seto mutt usen mose and renesn system Programming User codes for SINGLE USER mode 0 Enter NEW MASTER programming code Enter user code for relay 1 Enter user code for relay 2 Programming User codes for MULTIUSER mode OEE EE Enter up to 100 user codes for relay
7. instructions Q The unit calls the first number but voicemail comes on before it can ring the second number A Decrease the no answer time as per programming instructions Q The caller ID part does not work A Be sure to program the caller ID part under 72 feature If your number is a private or number withheld then it will not work Even if you have already programmed a number to receive a call from the intercom if you also want that number to have caller ID access it must be programmed under the 72 feature also Ensure the number is entered as you would normally dial it from another phone Do not put the country code in front of the number Enter the country code in which the unit is operating in separate under the 71 feature International callers ringing the intercom may not work Q There is no audio from the gate but the person at the gate can hear ok A This can be due to low reception Check reception level by 20 Change SIM card if necessary to another network which may have better coverage Purchase a high gain antenna This may also be caused by either a defective microphone or incorrect microphone wiring or a short circuit by whiskers between the centre core and the shielding or excessive microphone cable length Q The audio quality that can be heard on the remote telephone is poor or humming buzzing A A small amount of GSM buzz can be considered normal on GSM intercoms but not so much that ca
8. oblems or other issues Increase height of antenna change network or fit higher gain antenna 2 Program the numbers you wish the unit to dial when the call button is pressed up to a maximum of 3 numbers Each SMS must start with the pass code default 1234 in the following format 12 1234 followed immediately by a command E g to program the telephone number 0987654321 enter the following SMS 12 1234 1 10987654321 Up to 3 numbers can be sent together in a single SMS as follows 12 1234 1 1tel number1 12tel number2 1 3tel number3 11 Telephone number 1 12 Telephone number 2 13 Telephone number 3 Pass code Data Function code 3 It is recommended to change the no answer time if there is more than 1 number stored This stops the unit ringing a number after a set time and can be used to prevent voicemail answering the call Send the following SMS 42 1234 52 Where can be 2 digits from 10 99 seconds default is 20 The unit can allow up to 100 telephone numbers to be stored for users to be able to ring the system for automatic entry This uses caller ID like a phone to determine the identity of the caller First the unit must know what country it is operating in 4 Program the country code as follows 4 ox Where can be 1 3 digits For uk insert 44 for Ireland 353 Do not 1201284871 22 use any leading zeros 5 Enter the telephone numbers required to have access control Do not enter country c
9. ode just the complete number as you would dial it Up to 3 numbers can be sent together in the same SMS Just 12 1234 720987654321 add 72 then the number then each time The pass code only needs to be put at the beginning of each new messge Additional Programming Parameters Code Description Default 0177 Change programming password 02727292 Change access control password allows users not in caller ID list to call intercom and use pass code to activate relay 0377 Change monitoring mode password dial to listen in mode Delete a button calling number where n number 1 2 or 3 Speaker volume Where level 0 4 Microphone volume Where level 0 4 Relay time Where 1 9999 seconds Max call time Where 005 999 seconds 3 digit code Max monitoring time for listen in mode when calling the intercom 00 60 mins 00 no limit Unit can call or SMS service number by set duration to prevent SIM card deactivation if seldom used 00 60 days 00 no inform 58 Choose between scheduled call to service number or send SMS to service number 1 for SMS 2 for call 77number Store service number to receive scheduled SMS or call from intercom Delete service number Dial in mode for withheld numbers or non stored numbers 1 65 answer the call amp wait for pass code 2 answer the call amp automatically activate 2 way speech 13 Delete phone number for caller ID access N Delete all p
10. uses inability to hear the person speaking This can be caused by the GSM antenna being mounted too close to the speech panel or not mounted high enough Try earthling the speech panel chassis to OV of the power supply This is also a symptom of poor reception Try above steps on checking and improving reception Q The or key does not work when the intercom calls a phone A Check if you can hear the relay clicking at the gate when the or key is pressed during a call If it can be heard then the system is working check wiring between the relay and the lock or gate panel If the relays do not make a clicking sound then check this feature on a different mobile cell phone or landline If it works on a different phone check the settings on the phone in question under DTMF tones Failure of DTMF tones to operate correctly is also a symptom of low reception Check steps above on improving reception Try pressing the buttons longer when attempting to activate the gates or door User Manual For GSM 3AB GSM 3ABK Wireless Intercom This GSM intercom system will call up to 3 telephone numbers in sequence when the call button is pressed There are several modes of operation depending on how the unit has been programmed by your installer The following instructions will assume default programming Intercom calling your phone My Gate Call button CALLING pressed ANSWER DECLINE x Answer call Sending S

Download Pdf Manuals

image

Related Search

Related Contents

RAIJINTEK Arcadia  020_オフサルミックヤグレーザ(46KB、PDF形式)  beim GraphicConverter  Canon Museo Silver Rag 300g/m 48.3cm, 25sht  ABRIDOR PUERTA CORREDERA GUIA DEL USUARIO Manual  Sartocon® Slice  Simon XT V2 Quick Operation Guide  Mode d`emploi toises en bois  KNEE BRACE - Breg Inc.  Presto Dual Basket ProFry User's Manual  