1. PM Preset Sequence Sequence timing T supply Belden 8471 installed Installation Procedure 11 The six position pluggable screw terminal labeled J3 Panic LON is provided as the termination point for both Emergency and SmartLink control J2 Control L Connect Emergency Step 1 Strip 6mm 1 4 of insulation from the ends of the two 16 AWG wires Step 2 Remove the 6 position pluggable connector from J3 on the I O PCB Step 3 Twist the two 16 AWG wires together as close to the connector as possible Step 4 Connect the two 16 AWG wires to pins 5 and 6 Step 5 Tighten the screw firmly onto each wire Connect SmartLink Termination is available for up to two separate SmartLink data runs and is FTT 10A topology free and polarity independent utilizing a LonWorks network For systems utilizing SmartLink wall stations ETC recommends terminating the station data run to the SmartPack with the LinkPower supply installed and utilizing the second data bus for SmartLink pack to pack synchronization A clean installation assists with troubleshooting efforts when needed One LinkPower supply S LPS per system is required to power up to four SmartLink wall stations Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 St
2. Low voltage wiring must be routed separately from high voltage wiring Step 3 a All low voltage terminations are conveniently located in the I O compartment of the SmartPack Wall Mount unit Two 12 7mm 1 2 knockouts are provided for low voltage control wiring Pull AC input and load wires through the conduit previously installed Using 90 C copper wire To comply with UL requirements for wiring ampacities Use Copper Conductors Only the torque rating for each Non Class 2 field wire connector and Use 90 C Conductors at the 75 ampacities where readily visible in the field wiring connector Use only 90 C rated copper wiring installed in accordance with all applicable electrical codes a Pull individual loads with earth ground and neutral connections b Pull power supply wiring for predetermined three phase or single phase operation CAUTION The SmartPack Wall Mount unit ships with a debris shield to protect the electronics during installation Leave this shield in place during installation and remove only after installation is complete before energization If debris falls into the fan or electronics remove the debris before applying power to the unit Step 4 Pull all low voltage control wiring as required for the installation through the conduit previously installed to the I O compartment knockouts Installation requirements for low voltage terminations may include the following
3. DMX In required when the SmartPack is to be controlled by a DMX source e DMX Pass thru allows pass thru of the DMX signal to other DMX devices This connection used point is necessary only when using IDC connectors for DMX over CAT 5 cable e SmartLink station wiring is FTT 10A topology free and polarity independent Wiring may be bus star loop home run up to two home run termination points available or any combination of these Emergency receives a contact input which in combination with software settings switches power for selected emergency loads to full and all non emergency lighting loads off SmartPack Wall Mount Installation Connect Wiring Power Supply Connections Three Phase Supply Connections Input Wiring Supply cable Lugs will accommodate 25mm 2 AWG maximum stranded cable Important Note Supply cable gauge must be coordinated with upstream protective switchgear To Circuit Breakers Single Phase Supply Connections North America Input Wiring Supply cable Lugs will accommodate 25mm 2 AWG maximum stranded cable DODDODDO DODDODDODDDDO OD To Circuit Breakers CAUTION The SmartPack Wall Mount unit ships with a debris shield to protect the electronics during installation Leave this shield in place during installation and remove only after installation is complete and before energization If debris fa
4. 10 Load 10 Connect Control Wiring 11 Emergency 11 Connect Emergency 12 Connect 56 12 Connect ESD 13 DMX 512 Acton peg quem ta ws RA aed eee se S 13 Connect DMX eria cee en Rte oe hen A 13 Guidelines for Data 14 Final Installation and 15 Verify Installation 15 Final Installation and Power 15 Select the operating 16 Set a level for a 16 Verify DMX512 Operation 16 S6I VICO coi dida E Tae Ru ERR de UR NE AIRE ATE eee 17 LinkPower Supply Kit 18 Installation Procedure 18 ETC SmartPack SmartSwitch and SmartLink are either registered trademarks or trademarks of Electronic Theatre Controls Inc in the United States and other countries LonWorks and LON are registered trademark of the Echelon Corporation All other trademarks both marked and not marked are the property of their respective owners e gt Introduction Congratulations on y
5. Wall Mount UL Installation Manual Revision B Copyright Electronic Theatre Controls Inc All Rights reserved 0 LISTED Product information and specifications subject to change Part Number 7021M2120 EN Rev B Released 03 2007 Table of Contents INMPOGUCHON gba d ex bari o 1 Using this 1 Product V riants 2 a tree ace dha quads dea qs 2 Weights and Dimensions 2 Help from ETC Technical Services 3 Prepare for Installation 4 Installation 4 Electrical 4 Verify the Contents of the Shipping Carton 4 Additional Parts and Specialty Tools Required 4 Cable Specification 5 Compliance e utpat deh Eden 5 Cable Routing and Conduit 6 Installation Procedure 7 Install Mounting 7 Mount the SmartPack Wall 7 Connect Wiring 9 Power Supply Connections 9 Three Phase Supply Connections 9 Single Phase Supply Connections North America 9 Earth Ground and Neutral Connections
6. of threads for mounting the SmartPack Note Access holes to tighten bolts screws are shown in the Cable Routing and Conduit Access on page 6 Mount the SmartPack Wall Mount Step 1 Remove the front cover to reveal the SmartPack interior Note The SmartPack Wall Mount unit ships with a debris shield to protect the electronics during installation Leave this shield in place during installation and remove only after installation is complete and before energization Step 2 Mount the SmartPack to the mounting bolts previously installed Step 3 Tighten the mounting bolts securely e Check for a plumb installation and follow all local code restrictions Installation Procedure iN Rough In Conduit and Cable SmartPack Wall Mount dimmer packs include removable plates located on top bottom and both sides to accommodate conduit fittings for power supply and load wiring Additional wiring space is provided in the top of the unit for contractor convenience Two knockouts are provided one on each lower side specifically for low voltage control wiring See Cable Routing and Conduit Access on page 6 Step 1 Step 2 Install conduit for AC Input and load wiring to the pack in the appropriate locations a The SmartPack Wall Mount unit is available with either 6 or 12 dimmers Make sure conduit is sized appropriately for the required wire Install conduit as required for low voltage control wiring
7. 7 LinkPower Supply Remove power from the control electronics a Fora SmartPack Wall Mount switch the Standby breaker OFF b Fora SmartSwitch relay panel switch the circuit breaker OFF at the breaker panel Remove the two screws securing the I O panel to the chassis Fold the I O panel down to reveal the control terminations I O board Angle the LinkPower supply board approximately 10 insert the four pins as found on the LinkPower supply into the receptacle on the I O board Align the LinkPower supply with the four screw mounts located on the I O panel and secure with the four screws provided Do not over tighten the screws Close the I O panel and secure with the two screws Re apply power to the control electronics SmartPack User Manual EY LinkPower Supply Kit This page intentionally blank 19 20 This page intentionally blank SmartPack User Manual 21 This page intentionally blank SmartPack User Manual Corporate Headquarters 3031 Pleasant View Road P O Box 620979 Middleton Wisconsin 53562 0979 USA Tel 608 831 4116 Fax 608 836 1736 London UK Unit 26 28 Victoria Industrial Estate Victoria Road London W3 600 UK Tel 44 0 20 8896 1000 Fax 44 0 20 8896 2000 Rome IT a Via Ennio Quirino Visconti 11 00193 Rome Italy Tel 39 06 32 111 683 Fax 39 06 32 656 990 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany Tel 49 80 24 47 00 0 Fax 49
8. 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong Tel 852 2799 1220 Fax 852 2799 9325 Service Americas service etcconnect com UK service etceurope com DE techserv hoki etcconnect com Asia service etcasia com Web www etcconnect com Copyright 2007 ETC All Rights Reserved Product information and specifications subject to change 7021M2120 EN m Rev B Released 03 2007
9. Mount unit ships with a debris shield to protect the electronics during installation Remove this shield only after installation is complete and before energization If debris falls into the fan or electronics remove the debris before applying power to the unit Final Installation and Power Up Step 1 Attach the ground wire with the ring terminal from the chassis to the grounding stud on the I O panel and secure Step 2 Close the I O panel and secure with two screws a All wires should be dressed neatly b Ensure the wires are not crimped in the I O Panel while closing Step 3 Attach the ground wire with the spade connector to the front cover and secure the front cover to the unit Step 4 Apply power to the unit a Ifthe standby breaker is off turn it on UI 3PEREEEEBEEEEE Note Use the Standby Control power switch to start up and shut down operation of the SmartPack When the breaker is in the ON position the blue Power LED is illuminated indicating the power is on WARNING When the Standby Control power switch is in the OFF position the unit is still connected to the power supply When working on exposed load circuit wiring the load cables must be unplugged or the unit disconnected from the power supply Installation Procedure 15 Test Loads via Menu After power is applied to the unit select the operating language and test each load using the TEST MENU Select the operati
10. SL620W LPS 7021A1100 LPS 20 amp breaker D SL1210W 7021A1101 12 channel 30 or 1 SL1210W LPS 7021A1101 LPS 10 amp breaker Cover removed for clarity 6 or 12 dimmer channels available Variable speed cooling fan Capable of dimming multiple load types UL cUL Listed 32 built in presets and a sequencer for stand alone operation compartment DMX512 In DMX512 Thru Emergency contact input SmartLink Optional LinkPower supply for wall station support optional supplies power for up to four SmartLink wall stations requires 15 rack units of space LinkPower supply kit 19 Rack Mount kit Weights and Dimensions Installed Weight Dimensions mm inches SL620W SL620W LPS SL1210W SL1210W LPS 21kg 46lbs 666mm x 435mm x 157mm 26 24 x 17 14 x 6 20 22kg 48lb SmartPack Wall Mount Installation Help from ETC Technical Services Introduction If you are having difficulties your most convenient resources are the references given in this manual To search more widely try the ETC web site at www etcconnect com If none of these resources is sufficient contact ETC Technical Services directly at one of the offices identified below Emergency service is available from all ETC offices outside of normal business hours When calling for help please have the following information handy Model of SmartP
11. for each Non Class 2 field wire connector and Use 90 C Conductors at the 75 ampacities where readily visible in the field wiring compartment Class2 adjacent to each Class 2 field wiring connector Use only 90 C rated copper wiring installed in accordance with all applicable electrical codes Your supply gauge must be coordinated with upstream protective switch gear For use with emergency lighting loads the SmartPack unit must be supplied with normal emergency power DMX512 Recommended Belden 9729 Alternatives include Carol C0910 General 0E8990 Olfex 9729 Omni D62402 Quabbin 8604 Olympic 2998 Pro Plex PC224T CAT 5 cable is also approved for DMX distribution when installed in grounded metal conduit To use CAT 5 cable you will need to purchase a CAT 5 termination kit 4100A1013 Please contact your ETC equipment provider or ETC technical services for assistance SmartLink Belden 8471 plus 1 14 AWG ESD drain wire recommended drain wire not required if installed in grounded metal conduit For use with wall stations and SmartLink enabled pack to pack communications SmartL ink is FTT 10A topology free and polarity independent Emergency Compliance 2 16 AWG twisted UL Listed UL 508 file E152039 FCC Contact input for emergency lighting loads This device complies with part 15J of the FCC Rules Operation is subject to the following two conditi
12. ack Wall Mount Other components in the system if any including SmartSwitch Relay Panel LinkPower supply quantity and type of SmartLink wall stations etc DMX control source used for system wide control Americas ETC International Technical Services Department 3031 Pleasant View Road Middleton WI 53562 800 775 4382 USA toll free 1 608 831 4116 service etcconnect com Asia ETC Asia Ltd Technical Services Department Room 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong 852 2799 1220 service etcasia com United Kingdom Electronic Theatre Controls Ltd Technical Services Department Unit 26 28 Victoria Industrial Estate Victoria Road London W3 6UU UK 44 0 20 8896 1000 service etceurope com Germany Electronic Theatre Controls GmbH Technical Services Department Ohmstrasse 3 93607 Holzkirchen Germany 49 80 24 47 00 0 techserv hoki etcconnect com Prepare for Installation For proper operation of your SmartPack unit ensure that the intended installation location conforms to the following environmental and electrical requirements Installation Environment Dry room 30 95 humidity non condensing 0 35 C 32 95 F ambient temperature Dust free Wall mounting location must support 23kg 50165 Minimum 254mm 10 clearance in front of unit for airflow vents Electrical Requirements 208Y 120 VAC 50 60Hz Three phase 4wire and grou
13. dure 13 Data Termination The I O board includes termination switches for both SmartLink data runs and DMX 512 Follow termination guidelines as indicated in the graphic below Switch UP termination ON Switch DOWN termination OFF Guidelines for Data Termination SmartLink silk screened as LON data termination Fora single pack installation set switch 1 and 2 to the UP position If multiple packs are installed only one pack should terminate LON switch 1 and 2 UP All other packs should have LON switches 1 and 2 set DOWN e If there no SmartLink data runs set switch 1 and 2 DOWN DMX 512 data termination If the pack is the last or the only DMX device on the data run set switch UP Ifthe pack is not the last DMX device on the data run set switch DOWN SmartPack Wall Mount Installation Final Installation and Power Up Verify Installation Is the SmartPack unit securely mounted with all mounting bolts tight Is there sufficient clearance 25 4cm 10 in front of the unit Check wiring Are all power supply and load cables landed and properly terminated Areall unused cable access openings covered with plugs and all removable plates reinstalled Do all control cables meet specifications Are all data terminations in the I O compartment terminated Remove all metal shaving and debris from the unit SmartPack Wall
14. ep 8 Cut the Belden 8471 cable if necessary so that an 20cm 8 tail extends from the edge of the panel Strip 18cm 7 of the outer cable jacket off If pulling two 8471 cables label each pair with data type and run designation Example SL1 and SL2 Strip 6mm 1 4 of insulation from the ends of the Belden 8471 wires Insert the white wire from SL1 data run into pin 1 NETB terminal on the pluggable connector and tighten the screw firmly onto the wire Insert the associated black wire from SL 1 data run into pin 2 terminal on the pluggable connect and tighten the screw firmly onto the wire Repeat steps 5 6 to terminate the second data run SL2 if required to the remaining pins 3 and 4 terminals on the connector Tighten the screw firmly onto the wire Reinstall the 6 position pluggable connector to J3 on the I O PCB SmartPack Wall Mount Installation Connect ESD Ground For installations with SmartLink data runs Belden 8471 installed in grounded metal conduit there is no need to run or terminate an additional ESD drain wire For installations not installed with grounded metal conduit follow the instructions below for ESD termination Step 1 Locate the grounding lug on the tray of the I O panel just to the right of the I O termination board Step 2 Loosen but do not remove the set screw on the grounding lug Step 3 Strip 6mm 1 4 of insulation from the ends of the 14 AWG drain wire s and tw
15. ing should be between 18 21 Volts Check the voltage between Net B and ground This reading also should be between 18 21 Volts Checkthe voltage between Net A and Net B This reading should be between 36 42 Volts D 2005 ETC INC MADE IN USA If neither LED is illuminated the data connections are properly installed and stations are receiving the data and power required for operation If CR1 is illuminated but not CR2 Net A is shorted to ground If CR2 is illuminated but not CR1 Net B is shorted to ground If both are illuminated Net A and Net B are both shorted to ground Service If you have any difficulties installing your system or with system startup please contact ETC Technical Services at the office nearest you ETC contact information is located on page 3 of this document Installation Procedure 17 Appendix A LinkPower Supply Kit One LinkPower supply is required to power up to four wall stations over the SmartLink network A SmartLink system is limited to one LinkPower supply up to four wall stations and up to four SmartLink enabled SmartPack and or SmartSwitch products Due to the similar design for the SmartPack Wall Mount and the SmartSwitch relay panel control terminations the following instructions may be used for either product Installation Procedure The LinkPower supply kit S LPS 7021K1010 includes a LinkPower supply and four Screws Step 1 Step 4 Step 5 Step 6 Step
16. ist together Step4 Insert the 14 AWG wires into the grounding lug and secure with the set screw DMX 512 Two 8 position receptacles are provided on the I O termination board one for DMX IN and the other for DMX Thru Prior to connecting DMX follow the instructions for Belden 9729 cable preparation as defined on the single sheet instructions packaged with the 8 position pluggable screw connector A cable preparation kit for installation of CAT 5 cable is available contact ETC for assistance Connect DUX J5 DMX As shown with Belden 9729 color code PASS THRU Pin 1 Com Pin 2 DMX Black Pin 3 DMX Red DMX In and DMX Pass thru are on the same pluggable screw connector as shown For use with CAT 5 cable contact ETC for a CAT 5 termination and IDC connector kit ETC part number 4100A1013 sold separately 7021B4602 REV E 2007 ETC Inc Made in the U S A Assembly 702185602 Step 1 For DMX In and DMX Pass thru using Belden 9729 as recommended prepare the cable as described in the DMX Cable Preparation kit instructions provided Step 2 Using the 8 position pluggable screw connector provided in the cable preparation kit connect Shield COM DMX and DMX as indicated in the graphic above Step 3 DMX Pass Thru using Belden 9729 can utilize the same pluggable screw connector as DMX In Connect Shield COM DMX and DMX as indicated in the graphic above Installation Proce
17. l Mount Installation Connect Control Wiring SmartLink enabled Link Power Supply optional Emergency SmartLink DMX In DMX Pass thru ESD ground lug Emergency SmartLink DMX In and DMX Pass thru are connected in the I O compartment of the SmartPack Wall Mount unit Each connection uses a pluggable screw terminal which can be removed for easy wiring The RJ45 connection labeled J2 on the I O board connects the I O control board to the control CPU board for data communication to the SmartPack This connection has been completed at the factory prior to shipment The LinkPower supply provides power for up to four SmartLink wall stations SmartPack is available with or without the LinkPower supply For field installation of the LinkPower supply reference LinkPower Supply Kit page 18 Emergency SmartLink SmartLink is a control protocol that provides added functionality to the SmartPack Wall Mount dimmer pack for inter connectivity and shared communication between SmartPack dimmer packs and SmartSwitch Relay Panels The Emergency feature is a contact input to the product which in combination with software settings allows a third party device to trigger a selected group of loads to full while turning other loads off and disabling other control inputs SmartPack SmartPack SmartPack SmartPack
18. lls into the fan or electronics remove the debris before applying power to the unit Installation Procedure A Earth Ground bus Neutral bus Load Connections Earth Ground and Neutral Connections Step 1 Connect the earth ground conductor for each load to the Earth Ground bus Step 2 Connect the neutral conductor for each load to the Neutral bus Load terminals Load Connections Step 1 Step 2 Prepare load conductors by stripping 13mm 1 2 of insulation from the end of each wire Terminate load conductors to the load terminals a Align a 5mm 3 16 slotted screwdriver with the top of the load terminal and press down firmly until the terminal gate opens b Insert the wire into the terminal and remove the screwdriver These wires are factory installed by ETC prior to shipping the unit Take special care not to crimp onto the wire insulation Load conductors here Step 3 Repeat for the remaining loads CAUTION The SmartPack Wall Mount unit ships with a debris shield to protect the electronics during installation Leave this shield in place during installation and remove only after installation is complete before energization If debris falls into the fan or electronics remove the debris before applying power to the unit SmartPack Wal
19. nd 40A per phase 120 240 VAC 50 60Hz North American Single phase 3wire and ground 60A per phase Not suitable for use on Delta IT supplies This equipment must be connected to a suitable safety earth ground Verify the Contents of the Shipping Carton SmartPack unit with cover attached Warning labels If necessary please replace the warning label on your SmartPack unit with the label in the appropriate language for your installation DMX Cable Preparation Kit with 8 pin connector kit part number 4100A1012 SmartPack User Manual and Mounting Template Additional Parts and Specialty Tools Required 4 x 6 8mm 1 4 3 8 bolts or screws 50 100mm 2 4 long and suitable wall plugs are suggested Mounting hardware and surface must support 23kg 50 Ibs Conduit punch Conduit or bushes 12 7mm 1 2 diameter 3 8 slotted screwdriver for line terminals Phillips screwdriver for covers Jewelers slotted screwdriver for data terminations 5mm 3 16 slotted style screwdriver for load terminals Wire strippers SmartPack Wall Mount Installation Cable Specification Purpose AC Input 3 4 wire and ground 208Y 120 VAC 50 60Hz 40 amps per phase AC Input 1 3 wire and ground 110 240 VAC 50 60Hz 60 amps per phase Cable Type Description 25mm 2 ANG maximum stranded cable Using 90 C copper wire To comply with UL9 requirements for wiring ampacities Use Copper Conductors Only the torque rating
20. ng language Step 1 Apply power to the unit Available languages for SmartPack will scroll in the display at 3 second intervals Step 2 Press when the preferred language is displayed e Set Language English e Choisir la langue Fran ais Sprache ausw hlen Deutsch Seleccionar idioma Espa ol Set a level for a dimmer Step 1 Press 26 to enter the Test menu Step 2 Use or yw to scroll the selection of dimmers choose one or ALL dimmers Test Dimmer All Level 100 Step 3 Use or to set a level press The menu will progress to the next dimmer Step 4 Press 8 Exit Test Mode displays Exit Test Mode and retain all Test levels scroll to Keep Test On and press y Exit Test menu clearing all Test levels and return to the previous menu scroll to Test all off press y e Press lt to return to the Test menu e Press lt lt to exit the Test menu clearing all Test levels and return to the main menu Verify DMX512 Operation Test each load with DMX512 using a control console or DMX512 test device SmartPack Wall Mount Installation Troubleshooting SmartLink After all SmartLink control stations are installed and connected to the SmartLink enabled product check for shorts and cross connections with a digital voltmeter at the station LinkPower pigtail connection and the station ground connection meter points Check the voltage between Net A and ground This read
21. ons 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Prepare for Installation Cable Routing and Conduit Access A CAUTION In order to maintain safety and proper airflow and cooling do not leave any panels removed unless facing an adjoining SmartPack Removable plates on either side Removable plates on top and bottom Remove appropriate plate to punch Remove appropriate plate to punch conduit conduit access as needed for AC input access as needed for AC input and load and load wiring Remove plate wiring Remove plate permanently if permanently if SmartPack is mounted SmartPack is mounted below another to the side of another SmartPack SmartPack or SmartSwitch Rear Earth Ground and Neutral bus Load terminals AC Input l
22. our purchase of the ETC SmartPack Wall Mount dimming pack C US SmartPack continues ETC s tradition of providing the highest quality products for the LISTED entertainment and architectural lighting market Using this Manual Use this manual during the installation of the SmartPack Wall Mount unit This manual includes instructions for installing SmartPack units to operate stand alone or on a SmartLink control network For user configuration and system operation instructions please refer to the SmartPack User Manual The following symbols are used in this manual to alert you to danger or important information Note Provides important information about your installation CAUTION A Caution statement indicates situations where there may be undefined or unwanted consequences of an action potential for data loss or an equipment problem WARNING A Warning statement indicates situations where damage may occur people may be harmed or there are serious or dangerous consequences of an action WARNING RISK OF ELECTRIC SHOCK This warning statement indicates situations where there is a risk of electric shock Please email comments about this manual to TechComm etcconnect com Introduction 1 Product Variants The instructions in this manual apply specifically to the following SmartPack Wall Mount models Part Number Channel Count Voltage Breaker Type Supply SL620W 7021A1100 6 channel
23. ugs o 919 ej 7 2 2 5 Ole jer ae 9 2 D LH Ww 5 o 2 4 2 E E S am TW o o U U GHARTPASK BES Knockouts in the lower side Bottom panels accommodate conduit Access holes for or bushes for low voltage mounting bolts or screws control wiring to the I O compartment Rear 6 SmartPack Wall Mount Installation Installation Procedure Install Mounting Hardware Step 1 Affix the mounting template included in the shipping carton to the wall to guide the placement of the mounting bolts or screws an 127mm 5 0 305mm 12 07 SmartPack Wall Mount units may be mounted up to two high by any width Allow clearances as described on page 4 SmartPack Wall Mount can mount next to the SmartSwitch Relay Panel which share the same dimensions and cable access for installation convenience Step 2 Install the hardware required for mounting the SmartPack using the four measured keyholes on the full scale mounting template as a guide Four 6 8mm 1 4 3 8 bolts or screws 50 100mm 2 4 long and suitable wall plugs are suggested mounting hardware Both the surface and the mounting hardware must support 23kg 50165 Expose at least 25mm 1