Home

HUNT ENGINEERING API for RTOS-32 Installation and User Manual

image

Contents

1. HUNT ENGINEERING suppomersof _ _ Chestnut Court Burton Row treme DSZ Brent Knoll Somerset TA9 4BP UK Tel 44 0 1278 760188 Fax 44 0 1278 760199 Email sales hunteng co uk http www hunteng co uk http www hunt dsp com HUNT ENGINEERING API for RTOS 32 Installation and User Manual Document Rev B API software Rev 1 9 7 J Thie 24 05 04 COPYRIGHT This documentation and the product it is supplied with are Copyright HUNT ENGINEERING 1999 2001 All rights reserved HUNT ENGINEERING maintains a policy of continual product development and hence reserves the right to change product specification without prior warning WARRANTIES LIABILITY and INDEMNITIES HUNT ENGINEERING warrants the hardware to be free from defects in the material and workmanship for 12 months from the date of purchase Product returned under the terms of the warranty must be returned carriage paid to the main offices of HUNT ENGINEERING situated at BRENT KNOLL Somerset UK the product will be repaired ot replaced at the discretion of HUNT ENGINEERING Exclusions If HUNT ENGINEERING decides that there is any evidence of electrical or mechanical abuse to the hardware then the customer shall have no recourse to HUNT ENGINEERING its agents In such circumstances HUNT ENGINEERING may at its discretion offer to repair the hardware and charge for that repair Limitations of Liability HUNT ENGINEERING makes no warranty as to the f
2. 12 COMPILE PARAMETERS ike gees 12 E EE LE EE E RETR Sea SEHR OE IEEE ERI EE EOS 12 13 13 IMPLEMENTATION 18550 5 14 VIRTUAT OR PHY SIGAL MEMORY 14 PRE EMPTIVE OR CO OPERATIVE MULTI TASKING 14 READ AND WRITE PHREADS 15 ENVIRONMENT VARIABLESG ccseccssecececeessssseecececsensuececececsessseeeeeeeceesesssaeeeeeceesessaeeececeeeesnsaeeeeceeeeeneaaeas 15 MASTERMODE AND INTERRUPTS cccessessscecececeesssececececsesssececeeecseseseaesececsenesaaeeeeceseeeaaseeeeseeeeensaaeas 16 17 API REFERENCE 18 TECHNICAL SUPPORD cicccccscieccecscdscceseceeccescteccnascesecceseccbccesecteseeccceccocscesocecceccoccesetee 19 4 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL Installation Guide To develop RTOS 32 programs the RTOS 32 manual recommends using a development machine running Windows and a target machine running RTOS 32 A Hunt Engineering board would be present in the target machine On the Windows machine you would then develop RTOS 32 programs these programs are then downloaded over RS 232 to the target machine or run off a floppy disk To develop DSP programs for your HERON modules you need to
3. ttosdrv lib from the CD software api rtos32 into the installation directory 3 Copy the four include files and hecodes c from the CD software api heapi into the installation directory 4 Optionally you may want to copy the example directory tree from the CD software examples host_api_examples c6x into the installation directory 5 Define an environment variable HEAPI_DIR and set it to point to your installation directory For example edit autoexec bat and add a line set heapi_dir c heapi Then reboot the machine Uninstall 1 Insert the HUNT ENGINEERING CD 2 A new window should now appear Select Install Drivers amp Tools If the window doesn t appear use Windows Explorer and browse to your CD drive Then double click on 5 3 Next select UnInstall Follow the instructions Alternatively you can uninstall via Windows Go to Start gt Settings gt Control Panel then double click on Add Remove Programs Select HUNT ENGINEERING and click the Add Remove button Follow the instructions If you want to re install the API first reboot 9 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL HERON Carriers Confidence Checks RTOS 32 Confidence Check To confidence check the RTOS 32 part of the installation please have a look at the exam ples They are on the HUNT ENGINEERING CD in the software examples host_api_ ex
4. Log in as Administrator onto your Windows 2000 XP machine 2 Insert the HUNT ENGINEERING CD 3 A new window should now appear Select Install Drivers amp Tools If the window doesn t appear use Windows Explorer and browse to your CD drive Then double click on DSP_CD A Next select Install or Upgrade 5 The InstallShield setup program will now start 6 After two screens destination folder board type you should see x Select components Select the OS support you wish to install Windows support 2 YswWorks support lt Back Cancel Make sure that you select the proper components as explained in the Installation Guide Ie for cases 1 2 and 4 select both Windows support and RTOS 32 support 7 Follow the directions given by setup 6 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL The setup program usually installs the drivers straight away without rebooting After the drivers are installed the setup program will confidence check the installation The HUNT ENGINEERING board must be inserted in this machine or else the confidence checks will fail If you upgrade from an earlier API version first un install the old API installation Then reboot the machine Then follow the instructions above Windows NT Installation The API supports Windows NT V4 0 It has been tested with Service Pack 3 and 4 and without a
5. Service pack but it should work on all varations To install 1 Log in as Administrator onto your NT machine 2 Insert the HUNT ENGINEERING CD 3 A new window should now appear Select Install Drivers amp Tools If the window doesn t appear use Windows Explorer and browse to your CD drive Then double click on DSP_CD A Next select Install or Upgrade 5 The InstallShield setup program will now start 6 After two screens destination folder board type you should see Select components X Select the 05 support you wish to install Windows support VxWorks support lt Back Cancel Make sure that you select the proper components as explained in the Installation Guide Ie for cases 1 2 and 4 select both Windows support and RTOS 32 support 7 Follow the directions given by setup The setup program will try to reboot the PC once After the reboot the setup program will confidence check the installation The HUNT ENGINEERING board must be inserted in this machine or else the confidence checks will fail If you upgrade from an earlier API version first un install the old API installation Then reboot the machine Then follow the instructions above 7 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL Windows 95 98 ME Installation 1 Insert the HUNT ENGINEERING CD 2 A new window should now appear Select Install Dr
6. and with the RTTARGET 32 libra ties 1432 15 and optionally rttheap lib For example in the Microsoft Visual C C 12 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL makefile you would have C C files cl MT Fm Zi D_RTOS32 1 C C files DIR rtos32 rtosdrv lib rtfiles lib rtfsk32 lib rtk32 lib drvrt32 lib rtt32 lib rttheap lib LNKOPT Initialisation RTOS 32 example programs for RTFILES 32 usually include file init c You may want to use the same file for your own project s The file is also used in all HUNT ENGINEE RING API example programs At the beginning of the init c file the following comment Some standard initializations for RTFiles 32 programs This file is linked with most RTFiles 32 demo programs It provides a convenient place to configure RTTarget 32 and RTFiles 32 Also the RTKERNEL 32 library needs initialisation s The standard initialisation as used in RTOS 32 programs is Initialize the kernel and keyboard driver RTKernelInit 5 KBInit The same code has been used in the HUNT ENGINEERING API examples CFG file The HEPC9 and other HEART boards not HEPC8 use MasterMode by default MasterMode is like dma except that the dma engines are on the board HEPC9 itself With RTOS32 MasterMode uses fixed buffers with a fixed physical address which must be defined in your CFG file Below
7. have Code Composer Studio installed This program is not only a debugger but also an IDE Integrated Develop ment Environment and includes a real time kernel DSP BIOS To use Code Composer Studio and develop DSP programs you need to have a Hunt Engineering board inserted in the same machine where Code Composer is installed Combining both of these demands one possibility is to insert the Hunt Engineering board in the development machine and use this combination to develop the DSP code Once this is ready move the Hunt Engineering board over to the target machine and develop the RTOS 32 code Another possibility is to have a dual booting target machine dual booting between RTOS 32 and Windows In this case too the DSP code development and the RTOS 32 code development will proceed seperately A third possibility is to connect the JTAG of the Hunt Engineering board in the target PC to a JTAG interface card in the development PC However not all Hunt Engineering boards support this setup For exam ple the HEPC8 has no JTAG in or out connectors and you cannot use an external JTAG interface board Finally a fourth option is to have only one machine dual booting between Windows and RTOS 32 In the first case Windows development machine and RTOS 32 target machine you should do a Windows RTOS 32 install on the development machine Make sure that the carrier board is in the development machine while installing In the second ca
8. section in the API for Windows Installation and User manual Different PCI slots may have different resources assigned to them One thing to try is to move the HERON carrier board to other unused PCI slots If that doesn t work you can try swapping the HERON carrier board with other PCI boards The HEPC9 board uses MasterMode which is like dma but with the dma engines on board of the HEPC9 Sometimes a motherboard doesn t support MasterMode properly and you can try if the Confidence Tests succeed if MasterMode is disabled In the PC BIOS you may have an ECSD setting Electronic Configuration Setup Data If it exists it must be cleared Clearing this field gives you one 1 chance to install a new board After 1 reboot this ECSD reverts to being set So each time you want to install or re install or re arrange PCI boards you need to clear this ECSD switch again Usually you can access BIOS settings by pressing DEL or F2 very soon after a reboot far before the operating system starts to run You would see a message at the bottom of the screen saying something like press DEL to go to setup Please refer to your motherboard s manual if necessaty With an HEPC8 board verify the following 1 The boot jumpers of the module in slot 1 must be set to boot from FIFO 0 2 The board switch the red one must be set to 0 3 sure that there is a HERON processor module in slot 1 Also ensure that the HERON modul
9. 9 8 Linux support updated to full 1 9 7 3 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL TABLE OF CONTENTS REVISION HISTORY 3 INSTALLATION GUIDE 5 HERON CARRIERS INSTALLATION 2 0 ccccccscsssssssssccccccccscecescsccccesceecesesscscces 6 GENERA Lio Oak ood chive gs ence ETE EEE 6 Windows 2000 LXP sala O 6 Windows NT InstQllation 7 Windows 95 98 ME Installation cccccccccccccccscsscssccsccscsessssscsssccecessesssassesccsssesssasssecesesessssssassesseseeessaes 8 cess ec boeken docs vibe tous deve 8 532 MANUALANS 8 WININST ALT EE E 9 HERON CARRIERS CONFIDENCE CHECKS 10 RTOS 32 CONFIDENCE CHECK cccccccessessscecececsessauececececsessaececececseseaeaeeececseneseaeeeceeseseaaeeeeeesesensaaees 10 WINDOWS CONFIDENCE CHECK 10 HERON CARRIERS TROUBLESHOOTING scscsccccssssssssscsccccceecesesssceces 11 GENERAL FOR ALL WINDOWS VERSIONS ccsscesseesseeseceseeeseceaecaeecseecseesaesseesseeeseensecesecaeenaeessecsaeeneenes 11 HOW TO USE THE API WITH 32 12 12
10. E Switch NoPCIMasterMode switches 1 Switch Last Status 9 0 FifoA amp hDevice switches if Status return error HeGetLastOsError hDevice Similarly you can tell the driver not to use interrupts By default the driver uses interrupts but with some motherboard chipsets interrupts don t work properly sometimes In such cases you can try to switch off interrupts As with MasterMode telling the driver not to use interrupts is done via the HeOpenS function this time with a different switch DWORD switches 2 switches 0 HE Switch NoInterrupts switches 1 Switch Last Status 9 0 FifoA amp hDevice switches if Status OK return error HeGetLastOsError hDevice The switches array can be any length but the last valid array element must have the value HE_Switch_Last The parser in the HeOpenS function will process switches until it reads the HE_Switch_Last value To switch both MasterMode and interrupts off you can combine the above into one switches array HE DWORD switches 3 switches 0 Switch NoInterrupts switches 1 HE Switch NoPCIMasterMode switches 2 HE Switch Last Status 9 0 FifoA amp hDevice switches if Status HE OK return error HeGetLastOsError hDevice The order of the switches is not im
11. amples directory Copy the examples onto your harddisk to a convenient location If you installed the HUNT ENGINEERING API with library and examples you will already have the examples directory in c heapi etc Assuming you installed into c heapi The examples double as a confidence check as well Each of the examples has an RTOS 32 sub directory where RTOS 32 specific makefiles etc are located They assume you use a floppy disk to run the examples on the RTOS 32 target machine PDF documents in the example directories will explain further how to compile link and run the examples Windows Confidence Check Program If you selected Windows Support then the setup program will automatically have done a number of confidence checks You can do the confidence checks manually also The Windows Confidence check program is installed automatically on any Windows version It is started up as follows Start gt Programs gt HUNT ENGINEERING gt Confidence checks Please review the HUNT ENGINEERING s API amp Tools Windows installation manual for more information on the Confidence Check program 10 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL HERON Carriers Troubleshooting General for all Windows versions For troubleshooting please review the Troubleshooting section in the API for Windows Installation and User manual The following suggestions are just a summary from what is described more fully in the Troubleshooting
12. an 1 HeRead at a time and you cannot issue more than 1 HeWri te at a time with the same fifo But you can issue 1 HeRead and 1 HeWrite at a time on the same fifo or 1 HeRead on e g FifoA and 1 HeRead on e g FifoC at the same time After a HeRead or HeWrite has been executed you need to confirm the end of the transfer using HeTestlo or HeWaitForlo before you can issue the next HeRead or HeWrite Read and write threads run at a high priority The priority for fifo threads is 51 the priority for HSB threads is 50 In case you want to change this please use any or all of 14 environment variables as specified in the next section Environment variables The HUNT ENGINEERING API for RTOS 32 recognizes 14 environment variables that can be used to set a read or write thread s priority Variable HE_RDPRI_HSB sets the HSB read thread priority default 50 Variable HE_RDPRI_FIFOA sets the FIFOA read thread priority default 51 Variable HE_RDPRI_FIFOB sets the FIFOB read thread priority default 51 Variable HE_RDPRI_FIFOC sets the FIFOC read thread priority default 51 Variable HE_RDPRI_FIFOD sets the FIFOD read thread priority default 51 Variable HE_RDPRI_FIFOE sets the FIFOE read thread priority default 51 Variable HE_RDPRI_FIFOF sets the FIFOF read thread priority default 51 Variable HE_WRPRI_HSB sets the HSB write thread priority default 50 Variable HE_WRPRI_FIFOA sets the FIFOA write thread priority default 51 Var
13. ask with the highest priority will be made to run just like the pre emptive case Why is this important Well consider a low priority task that wants to test if a read or write transfer has completed while status HE OK status HeTestIo pIoStatus With co operative multi tasking this inifinite loop would prevent any other task from run ning Therefore the HeTestlo function is programmed in such a way that a task switch can occur The RTKScheduler function is called within HeTestlo Thus you need to be aware that HeTestlo and also HeWaitForlo may trigger task switches In the case of the HeWait Forlo function it is RTKWait function that may possibly cause a task switch With pre emptive multi tasking you have no such worries A task switch may occur at any time and infinite loops as shown above pose no problems 14 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL Read and Write Threads The HeRead function will not perform a read transfer itself but instead will ask a read thread to perform the read transfer Similarly the HeWrite function will not perform a write transfer itself but instead will ask a write thread to perform the write transfer read or write thread is associated with HE_IOSTATUS not with _ When the HE_IOSTATUS is used for the first time ie the first HeRead or HeWrite using that HE_IOSTATUS the associated thread is actually started up You cannot issue more th
14. asking but also with co operative multi tasking However you have to be much more careful when using co operative multi tasking The API uses threads to execute read and write requests For example the HeRead function will merely initiate a read transfer by asking a read thread to perform the transfer The HeRead then returns with return value He_IoInProgress Similarly the HeWrite function only initiates a write transfer You must use HeTestlo to test if the transfer has completed ot HeWaitForlo to wait for the transfer to complete The read and write threads run at a high priority 51 Interrupts are used to inform the read and write threads that any data can be read or written The interrupt routine uses semapho res to implement this If there s no data to read or write the read and write threads sit idle waiting for the interrupt semaphore With pre emptive multi tasking as soon as an interrupt comes in the interrupt semaphore is signalled if the read or write thread has the highest runnable priority they will immediate ly start to run If not they will start to run after higher priority runnable tasks have changed state to waiting or have completed With co operative multi tasking the interrupt semaphore is signalled as well However the reads and write threads will have no chance to start running until the current thread makes a kernel call that may trigger a task switch Once the kernel call is made the t
15. e in slot 1 is plugged in properly To be sure take the HERON cartier board out of the PC then remove the slot 1 module and re insert Now re insert the carrier board in your PC and try again 11 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL How to use the API with RTOS 32 When to use the API The HUNT ENGINEERING API offers a platform independent target independent way of accessing a HUNT ENGINEERING board You can write your own programs that use the API to boot DSP programs onto a board However the Server Loader may provide all functionality you need and you may not have to develop API applications The Server Loader is a HUNT ENGINEERING tool that can boot a network of DSP processors The Server Loader uses a network file that describes what processors must be booted with what file A network file is a simple and short ASCII file ASCII files can be created with for example edit on MS DOS notepad on Windows or on Linux In cases where you want the Server Loader to only boot the network and process messages from your DSP application yourself you can use the Server Loader library Please refer to the Server Loader manual for more information Include file All API applications must include lt gt in all source files that call API functions This include file is located in the root of the API installation directory The install program will have created an environm
16. ent variable HEAPI_DIR that points to your installation directory Therefore to make sure that the compiler knows where to find heapi h please add this path to the makefile s include path For example for Microsoft Visual C C INCLUDE RTTARGET include 8 DIR INCLUDE The bold italic part is what needs to be added to a standard RTOS 32 makefile for Microsoft Visual C C Compile parameters The HUNT ENGINEERING API covers several different operating systems In your application you have to select for what operating system you want to compile To select an RTOS 32 application set parameter _RTOS32 to 1 For example you could do this in the makefile on the compiler line For example for Microsoft Visual C C cl MT Fm Zi D_RTOS32 1 oreads exe This defines the _RTOS32 parameter to be one Also the HUNT ENGINEERING API library for RTOS 32 is a multi tasking library Therefore the compiler has to be notified to use multi tasking support For the Microsoft Visual C C compiler this means that the parameter must be used Libraries The HUNT ENGINEERING API library for RTOS 32 is a static library that uses multi tasking and file support rtosdrv lib That means that an RTOS 32 API application must be linked with the multi tasking RTFILES 32 libraries rtfiles lib and rtfsk32 lib with the RTKERNEL 32 libraries rtk32 lib and drvrt32 lib
17. iable HE_WRPRI_FIFOB sets the FIFOB write thread priority default 51 Variable HE_WRPRI_FIFOC sets the FIFOC write thread priority default 51 Variable HE_WRPRI_FIFOD sets the FIFOD write thread priority default 51 Variable HE_WRPRI_FIFOE sets the FIFOE write thread priority default 51 Variable HE_WRPRI_FIFOF sets the FIFOF write thread priority default 51 You can use environment variables with RTOS 32 via a configuration file For example in the reads example you could use the reads cfe configuration file and set the FIFOA tread thread priority to 60 in this file set HE 60 Please also refer to the RTOS 32 manual Part I Chapter 3 page 34 15 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL MasterMode and Interrupts Some HUNT ENGINEERING boards such as the HEPC9 support MasterMode This feature is easiest described as on board DMA Boards such as the HEPC9 have their own engines which ate used and accessed by the HEPC9 drivers Not all motherboards chipsets work perfectly with the MasterMode feature and the RTOS32 software allows you to switch it off ie tell the drivers to not use MasterMode Switching off MasterMode is done in your application program when opening a FIFO Use the HeOpenS function which takes a list of switches as option One of the switches then specifies to not use MasterMode A small example DWORD switches 2 switches 0 H
18. itness of the product for any particular purpose In no event shall HUNT ENGINEERING S liability related to the product exceed the purchase fee actually paid by you for the product Neither HUNT ENGINEERING nor its suppliers shall in any event be liable for any indirect consequential or financial damages caused by the delivery use or performance of this product Because some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty lasts the above limitations may not apply to you TECHNICAL SUPPORT Technical support for HUNT ENGINEERING products should first be obtained from the comprehensive Support section http www hunteng co uk support index htm on the HUNT ENGINEERING web site This includes FAQs latest product software and documentation updates etc Or contact your local supplier if you are unsure of details please refer to http www hunteng co uk for the list of current re sellers HUNT ENGINEERING technical support can be contacted by emailing support hunteng demon co uk calling the direct support telephone number 44 0 1278 760775 or by calling the general number 44 0 1278 760188 and choosing the technical support option 2 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL Revision History API ver 1 7 First API version to support RTOS 32 API ver 1 9 8 RTOS32 support updated to full 1 9 8 VxWorks support updated to full 1
19. ivers amp Tools If the window doesn t appear use Windows Explorer and browse to your CD drive Then double click on DSP_CD 3 Next select Install or Upgrade 4 The InstallShield setup program will now start 5 After two screens destination folder board type you should see Select components X Select the 05 support you wish to install Windows support VxWorks support Make sure that you select the proper components as explained in Installation Guide for cases 1 2 and 4 select both Windows support and RTOS 32 support 6 Follow the directions given by setup The setup program will try to reboot the PC once After the reboot the setup program will confidence check the installation The HUNT ENGINEERING board must be inserted in this machine or else the confidence checks will fail If you upgrade from an earlier API version first un install the old API installation Then reboot the machine Then follow the instructions above DOS Installation There is no HUNT ENGINEERING API support for DOS with RTOS 32 RTOS32 Manual Install There ate perhaps cases where you wish to install the RTOS 32 files manually Or perhaps you just want to understand what and where the RTOS 32 related files are 1 Create an installation directory for example somewhere on your harddisk 8 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL 2 Copy
20. ly the platform and carrier board independent API interface is explained in this manual 18 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL Technical Support Technical support for HUNT ENGINEERING products should first be obtained from the comprehensive Support section http www hunteng co uk support index htm on the HUNT ENGINEERING web site This includes FAQs latest product software and documentation updates etc Or contact your local supplier if you are unsure of details please refer to http www hunteng co uk for the list of current re sellers HUNT ENGINEERING technical support can contacted by emailing support hunteng co uk calling the direct support telephone number 44 0 1278 760775 ot by calling the general number 44 0 1278 760188 and choosing the technical support option 19 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL
21. portant There are other switches than HE Switch NoPCIMasterMode and HE Switch _NoInterrupts and they are defined in heapi h For RTOS32 however only the 2 switches mentioned here are relevant The default of the API is to use MasterMode and and to use interrupts In almost all cases this is the best option and gives highest performance It is only when you have trouble using MasterMode and or interrupts that you may need to try switching these off 16 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL Examples The HUNT ENGINEERING CD has a number of examples that show how you could use the API The examples are located on the CD in software examples host_api_examples c6x examples There will be PDF files in the example directories that explain how the examples work Each example directory has a number of sub directories each sub directory dedicated to a certain operating system In sub directory rtos32 you will find a PDF file that explains how to compile and build the example for RTOS 32 using the Microsoft Visual C C compiler 17 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL API Reference The API Reference Manual can be found in the manuals directory on the HUNT ENGI NEERING CD The Reference Manual explains in detail how to use the API shows all possible return values contains an overview of all functions in the API library plus a per function explantion and so on Essential
22. se Windows development machine and dual booting target machine you should do a Windows install on the target machine and an RTOS 32 install on the develop ment machine Make sure that the carrier board is in the target machine during installation In the third case Windows development machine and RTOS 32 target machine connected via JTAG you should do a Windows RTOS 32 install on the development machine Make sure that the carrier board is in the development machine during installation In the fourth case dual booting Windows and RTOS 32 single machine you should do a Windows RTOS 32 install Make sure that the carrier board is in the PC while installing 5 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL HERON Carriers Installation General RTOS 32 installation is integrated into the standard HUNT ENGINEERING Windows installation program As per the previous section you must decide whether to install for RTOS 32 only Windows only or RTOS 32 Windows The HUNT ENGINEERING CD install program will install and confidence check the API for Windows 95 98 ME NT W2K and DOS installations If for any reason you experience problems with installation or confidence checking use this section for a step by step installation check Windows 2000 XP Installation The API supports Windows 2000 installing WDM drivers This has been tested with Windows 2000 and Windows XP and the API works fine on both To install 1
23. the default entries in a CFG are shown Locate Nothing FifoABuffer HighMem 128k 32k ReadWrite Locate Nothing FifoBBuffer HighMem 128k 32k ReadWrite Locate Nothing FifoCBuffer HighMem 128k 32k ReadWrite Locate Nothing FifoDBuffer HighMem 128k 32k ReadWrite Locate Nothing FifoEBuffer HighMem 128k 32k ReadWrite Locate Nothing FifoFBuffer HighMem 128k 32k ReadWrite Obviously FifoABuffer is for Fifo A FifoBBuffer for Fifo B and so on The buffers are only used if you use the associated fifo and if you use MasterMode with that fifo The minimum size of the buffer has to be 16 kB The maximum size may be anything but the maximum that can be used is 128 kB and the API only uses the buffer in multiples of 4 kB 13 HUNT ENGINEERING API RTOS 32 Installation and User MANUAL implementation Issues Virtual or Physical Memory RTOS 32 has the option of using virtual or physical memory The HUNT ENGINEE RING API can be used with either option PCI cards such as the HEPC9 and HEPC8 use a memory mapped interface The HeOpen function will automatically try to find the HUNT ENGINEERING board you specified and map the interface memory area into the system using RTFindPhysMem RTReserveVirtual Address RTMapMem There is no need for you to make any provisions in your configuration files HUNT ENGINEERING board Pre emptive or Co operative Multi Tasking The HUNT ENGINEERING API can be used with pre emptive multi t

Download Pdf Manuals

image

Related Search

Related Contents

型 名 BM-RS。S/BM・RE08 修理メモ 量 お名前 駐  New Balance 5K 5100 User's Manual  SR2006-Mode d`emploi  Bedienungsanleitung  VIS flora survey public user manual  Oregon Scientific RGR-126 weather station  CytoTrack Proliferation Assay Kit  SERVICE BULLETIN No. 300-2-95  Prime-Line B 558 Instructions / Assembly  2011 Caldera Utopia et Paradise 50Hz Manuel d`utilisation Rev A  