InstallatIon manual
Contents
1. device Observe the mounting and installation advices of other used components Please retain this installation manual for future reference Fixing points of the KIOTO Module Every module must be fixed on four specified points see Picture 1 with continuous profiles The frame is designed and statically tested snow load up to 5400pa for all series wind load 2400pa for all series see Table 1 to be fixed on the longitudinal side Do not fix on the narrow side To resist the named snow and wind loads the marked distances in picture 1 must be followed when mounting To adjust possible tolerances of the substructure the distance from the top and bottom side of the module to the mounting profiles should be between 16 and 20 see Table 2 of the module length In case of a longitudinal mounting the specified mounting points must also be adhered to If this is not possible because of the substructure a crossbar system must be used The fixing of the pv modules must be done by clamping from the front side The clamping area at every clamping point must be a minimum 800 mm For the fixing of the screws a torque spanner should be used The rate of acceleration for a screw M8 material V2A is 20Nm Always use adequate corrosion free mounting material EE sg RG Rw 2 28 ST Sapa eae en aay a tye een lyn Sore eee yal ata mc c
2. Also check the substructure in regular intervals for their tightness Never try to open or repair parts of the module or of the junction box on your own All other trouble shootings repairing and maintenance works must be done by qualified skilled staff persons For further information relating to warranties etc please read through the GENERAL TERMS AND CONDITIONS of KIOTO Photovoltaics KIOTO Photovoltaics GmbH Solarstra e 1 9300 Sankt Veit Glan sterreich Art Nr 6903944
3. Mechanically Mounting works must be done when the environment and tools are dry Never use the junction box as handhold Consider local factors for example wind force wind speed and snow load Calculate these values with a security factor before mounting the modules In special cases a static calculation must be undertaken KIOTO modules are designed and tested to resist a suction force e g wind of maximum 2400 Pa and a static pressure force load e g snow of maximum 5400 Pa provided that they are mounted according to the specified points of application Ensure that there is adequate ventilation behind the modules To generate optimal output of the PV generator consider the perfect alignment and mounting angle of the PV modules Shadowing of the modules leads to loss of output Therefore take care that there is no shadowing on the PV array Never mount KIOTO modules in areas where abnormal aggressive conditions could occur When the modules are mounted on roof ensure that the roofs are fire resistant or that an appropriate fire protection layer designed for this use is installed In case of fire never extinguish with water Inappropriate installation could also lead to fire The PV modules must not be installed near flammable gases and liquids e g gasoline stations gas tanks color spraying plants etc Never install the module near naked fire or flammable materials The PV module is no LSG laminated safety glass
4. 6 Tighten the cable screw lock The initial assembly tightening torque is 1 3 0 2 Nm For this a slotted socket wrench with wrench size 13 mm is recommended Picture 9 Safety Note Never disconnect the connectors under load that means while the generator is operating Non compliance can be perilous This safety advice is also printed on the module cables and at the label of the PV modules Please retain this installation manual for future reference Laying of the solar cables Keep the length of cable connections as short as possible to optimize the energy yield and minimize sources of errors Consider this point while planning and sizing the generator Fix loose solar cables after mounting to avoid damaging Use only adequate fixing material conduits in the mounting profiles or UV resistant plastic tubes Take care while handling the cables to avoid damaging especially at low temperatures The cables should not be bent or folded in an extreme way Where possible use flexible cables Please follow supplier instructions Use conduits for laying and fixing of the cables To avoid voltages from indirect lightning strikes lay the feed line and return line very close to each other Always consider the polarity The cables must not lie between the mounting profiles and module backside to avoid damaging the module especially under heavy mechanical load Electrical connection Modules must be covered with a photo resistant
5. material during the whole mounting process Avoid damaging the cables Execute the system grounding according to national and international standards Sizing of inverters should be done before mounting by qualified persons to ensure an optimized energy yield For security reasons and to minimize maintenance works a DC disconnector should be installed between the generator and the inverter This could also be obligatory by law Installation manual security advices KIOTO module series In accordance to safety guideline EN IEC 61730 1 and 2 Connection of the PV module to a grounding system Power 54 series The grounding of the module could be realized in two of four corners of the module At the inside of the module framing in the area of the edge connector you will find an obvious grounding lug with a through hole for M6 minimum M4 screws The chosen grounding lug must be bent out of the module frame carefully about 90 see picture 2 Grounding lugs which are bended out by mistake must be left in this end position The adequately sized grounding cable must be connected with a stainless steel screw M6 x 20mm with two fan shaped washers on the outside and inside of the grounding lug and a self locking screw nut The assembly from the outside to the inside should be screw head fan shaped washer GROUNDING LUG fan shaped washer eyelet self locking screw nut Forthe professional grounding of the complete pv system th
6. INSTALLATION MANUAL Module series Version 4 0 June 2012 KIOTO Photovoltaics GmbH Solarstra e 1 9300 Sankt Veit Glan sterreich Please read this installation manual accurately before using the photovoltaic components The non observance could lead to damage to persons and or goods Further the guarantee and the product warranty could expire The installation of photovoltaic modules requires technical knowledge therefore this must be done by skilled and qualified persons The general handling of the product the using and the exact installation are beyond the control area of KIOTO Photovoltaics GmbH Therefore KIOTO cannot take responsibility for any damage loss or cost which is caused by inappropriate installation inappropriate handling of the product or wrong use General module handling Do not open or demount the module Do not remove any parts from the module Do not remove or damage any product markings Do not step on the module Do not drop the module Avoid any form of external force exposure Do not expose the module especially the module backside to any lacquer paint glue chemicals or other abrasive liquids Do not handle the module at the junction box Do not pull on the module cable by heavy handling Do not drill any holes in the framework or other components of the module Donotinterfere with the internal electrical connection of the module Contact your pv retaile
7. able and connectors plugs Only use cables and connectors plugs which are approved and tested for photovoltaic applications The choice of cables for the use in the pv generator must be based on sizing by a skilled person Cables with a cross section from 4mm to 6mm are recommended The optimum cross section should be determined by the maximum short circuit voltage and the complete length of the wiring line voltage drop Only use high quality cables to assure a failure free operating Ensure good isolation and whether UV durability of the cables The rated voltage of the solar cable must be 1000V minimum If possible use flexible cables to ensure consistency against movements wind etc This will make the laying of the cables easier please find detailed information in the next clause Only use tools which are approved for cutting isolating etc of the cables or employ qualified persons staff Further information about the connectors are available at the Tyco Electronics documentations o SOLARLOK Application Specifications 114 18488 1 o SOLARLOK Instruction Sheet 411 18305 1 o SOLARLOK Interconnection System Installation Manual 1654276 1 Please retain this installation manual for future reference Connectors plugs Only use connectors plugs which are approved and tested for photovoltaic applications Connect the plugs only in dry state and ensure a proper connection Safety advice Never disconnect the plu
8. e installer is responsible If a grounding system is already in use at the affected building the pv generator has to be integrated in this protection system against direct lightning strikes National standards have to be considered and executed Picture 10 Please retain this installation manual for future reference 10 Connection of the PV module to a grounding system Power 60 series The grounding of the module could be realized all four corners of the module At the inside of the module framing in the area of the edge connector you will find an obvious drill hole for ISO 7981 screws The adequately sized grounding cable must be connected with a stainless stell A2 ISO 7981 screw 3 9 x 6 5mm with a form C rounded head with two fan shaped washers on the outside and inside of the eyelet The assembly from the outside to the inside should be screw head fan shaped washer eyelet fan shaped washer frame Forthe professional grounding of the complete pv system the installer is responsible If a grounding system is already in use at the affected building the pv generator has to be integrated in this protection system against direct lightning strikes National standards have to be considered and executed Erdungskabel mit Kabelschuh 2x F cherscheibe Blechschraube nach ISO 7981 A4 Form C eo Picture 11 Installation manual security advices KIOTO module series In accordance to sa
9. ec E Mounting profile 45 EM peep ae EEE NOLO NE Anim ROWE Tey ENR AY Et OTe GENER ERI BASS BES mm BONN ES LIB L o Q E E Picture 1 Power 36 Series Power 54 Series Power 60 Series tested mechanical load 5400pa 2400pa 5400pa 2400pa 5400pa 2400pa snow load wind load Table 1 Power 36 Series Power 54 Series Power 60 Series min distance 240mm 240mm 266mm max distance 300mm 300mm 333mm module length 1507mm 1507mm 1666mm Table 2 Installation manual security advices KIOTO module series In accordance to safety guideline EN IEC 61730 1 and 2 Electrical connection of the PV generator Athigh direct current voltages as can occur in serial connections the risk of short circuits and electric arcs is higher To avoid this always use an adequate cross section for cables and connectors which are approved for the maximum specified value of open circuit voltage KIOTO modules are equipped with Tyco Solarlok junction box and cables that are designed specifically for the product The solar cable is an isolated whether and UV resistant product with a dimension of 4mm Type LTCC according to the Tyco specifications Atstrong currents as can occur in parallel connections the risk of warming of the connections is higher To avoid this risk use an adequate sizing of the cross section The solar cables must be approved for the possible maximum short circuit current Detailed information about the connection technique solar c
10. fety guideline EN IEC 61730 1 and 2 11 Initiation of the PV generator Before initiation of the generator please check all components observe the installation instructions of other components the electrical connection and all plugs that they are connected correctly and ensure that the connection is tight Solar generators with a direct current voltage from more than 50V must be installed initiated by qualified persons The open circuit voltage of every serial connection should be checked after initiation Follow the rule Result of the measurement sum of the open circuit voltages of the single modules Consider the actual time sun irradiation shadowing and other factors while measuring the open circuit voltage otherwise the result of the sum and the single results could deviate considerably Maintenance Clean the modules as necessary according to the degree of pollution with plenty of water a smooth cloth and without any detergent If other additives or devices like aggressive chemicals scrubbing agents sharp blades or steel wool are used the guarantee and product warranty will be invalid Never wipe off or scrape off pollution in a dry state of the module surface Check the module wiring and the single module plugs to ensure they are clean corrosion free mechanically ok and tight in regular intervals Attention Never disconnect the plugs under load Free the modules if necessary from high snow loads
11. gs under load when the generator is in operation Non compliance with this could have serious consequences This safety device is also printed on the delivered cables and the label of the PV modules The connector system is fully latched only when the latches have clicked onto the mating connector or junction box Wrong connection Biggap Latch open Picture 2 Correct connection Small gap Latch closed Picture 3 Assembly steps connector 1 Using the appropriate wire stripping tool strip the wire 9 mm 1 mm without damaging the strands o CN Picture 4 2 Insert the stripped wire into the terminal wire crimp barrel until it stops While holding the wire in place squeeze the crimp tool handles together until the ratchet releases eam Picture 5 Installation manual security advices KIOTO module series In accordance to safety guideline EN IEC 61730 1 and 2 3 Press the seal and cable pinch ring assembly into the connector housing until it stops If you use the pre assembled connector kit please go to 5 N Picture 6 4 Screw back shell nut onto connector housing U Picture 7 5 Push contact with cable into the connector housing until you hear the contact give an audible click and you feel the contact reach the end position To verify contact engagement give a slight gentle pull back on the cable to be sure that the contact is locked I GEB Picture 8
12. or sunlight The electrical tools use for mounting should be approved isolated and voltage proofed according to system voltage Do not bring electrically conducting parts not isolated tools jewelry or others in contact with the PV module the cable heads or the electrical plugs during the mounting In case of a roof mounting additional installations like fuses dc disconnectors earth fault detection etc may be necessary In this case use a qualified skilled person Never use the PV modules near or in rooms where flammable liquids or gases are stored or where theses liquids or gases could escape When modules are connected in serial only modules with the same current should be used When you are using a parallel connection only modules with the same voltage should be used Never operate the modules with a higher voltage than the maximum system voltage The maximum allowed number of modules used in a serial connection is an outcome of the maximum input voltage maximum input current of the used inverters charge regulators the used module type and the local temperature conditions The system voltage of 1000V must not be exceeded Installation manual security advices KIOTO module series In accordance to safety guideline EN IEC 61730 1 and 2 The maximum reverse over current is 15A When connecting more than two strings in parallel this value could be exceeded Therefore string fuses with a rating of maximum 15A have to be added
13. r if problems occur Please consider the maximum system voltage of 1000V Never align simulated sunlight on the module or parts of the module Observe the mounting and installation instructions of other used components Product marking product label The product label is placed on the backside of the module and contains all required important electrical and product specific values The information on the label relates to EN 50380 2003 and Standard Test Conditions 1000W m 25 C AM 1 5 The product label must not be damaged or removed otherwise the quarantee and product warranty will be invalidated Please retain this installation manual for future reference Technical data of the KIOTO Module Series KPV PE QCells KPV PE NEC KPV ME NEC KPV ME EC xxxWp in 5Wp Steps The modules are configured for the use in DC systems The use of the modules relates to class A dangerous voltage IEC 61730 higher than 50V DC EN 61730 higher than 120V dangerous power applications higher than 240W which are general accessible according to EN IEC 61730 1 and 2 Protection class II regulations are also fulfilled Maximum reverse over current verified according to IEC 61730 2 MST 26 of the module 15A Nominal current of the diodes SL1515 according to producer designation 16A Under open space conditions the PV modules could produce higher voltage and or current than specified on the product label To consider this in
14. the rating dimensioning of other system components electrical lines fuses etc which are in direct connection to the PV generator the values of Isc and Uoc should be multiplied by the security factor of 1 25 or the sizing should be done by qualified skilled persons staff Permitted ambient temperature for use and storage 40 C to 85 C Further technical information is available on the product specific data sheets Installation instructions for mounting Consider general health and safety requlations relating to mounting equipment on roofs and or buildings Secure the modules so that they cannot fall down during mounting and in further operation Take care and consider the wind and snow load figures for the affected area In addition observe the following Electrically The following should provide a basis to avoid fire formation of sparks and deadly electrical shock therefore they have to be followed stringently Remember in de energized state high contact voltage could occur and or deadly electric arc can be generated Cover the single modules during the mounting with a photo resistant material Description Modules are producing electrical energy as soon as the front side is exposed to light This could happen in connected and disconnected state Therefore high voltages which could be perilous are generated Never touch cable heads especially exposed ones during the mounting especially when the module is exposed to light