5G GSM STU User/ Installation Manual

image

Contents

1. F7 Function 7 Line Fault output for GSM 5G GSM STU only 0 LF relay on both PSTN AND GSM paths failed factory default LF relay on either PSTN OR GSM paths failed 2 _ LF relay on PSTN path fail only o O BSIA Form 175 LF relay on either path fail with ATS SINGLE ALL identification And ATS test 10 11 4 Reserved oS 5 Reseved o E LE rela vu PSTN foi RPS relay on CSM O OO OOO Reserved S 8 Resewed o E 9 Reserved S B Reserved oo C Reserved ooo D Reserved o Note When F7 3 then pins 10 amp 11 are used as path test alarms and cannot be used as alarm inputs F8 Function 8 AC fail delay Pressing set at the F8 menu option allows the Function 8 value to be configured At factory default the F8 digit is set to 1 0 No delay on AC fail input 15 minute 5 minute delay on AC Fail input Redcare 5G GSM STU Installation manual 04 07 2011 10 redcare 5G GSM STU User Installation Manual Input pin learn mode While the 5G STU is in the fully de commissioned state the polarity of the inputs can be learnt as follows e Ensure the display is showing NC Not commissioned e Arrange the inputs so that they are all in their Non Alarm state as required e Note if the GSM STU is plugged on to a panel then care should be taken not to connect additional voltage states to the inputs as panel damage may result e Once all inputs are set to the normal state Short out the the Sec pins
2. Similarly pin 10 amp 11 restores will be signalled when the STU s ATS input pin 8 is restored Common problems STU constantly shows AL F on the display The STU must have at least 15 mins 5 mins of uninterrupted restore condition on input F to clear the pin 13 AC Fail alarm STU does not show AL 00 The STU will only display AL O00 when all inputs are in the restored state and all outstanding alarms have been acknowledged On many panels it is normal to have at least pin 4 in the alarm state during day service so the display will cycle AL 4 and not show AL 00 5G GSM STU fails to UP on GSM path If the GSM STU fails to up on the GSM path it should be totally powered down and then re powered Wait for 45s until a valid signal strength is showing SS 12 31 and then request fo the STU to be upped If the STU still fails to up on the GSM path then contact the redcare helpdesk to check that the SIM card is correctly enabled and the redcare account is built correctly 5G STU fails to up on PSTN path Check that redcare chirps are present at the STU line terminals when the UP command is sent Check that 50V line voltage is present at the STU line terminals If the STU still fails to UP then contact the redcare helpdesk for further checks Redcare 5G GSM STU Installation manual 04 07 2011 13 redcare 5G GSM STU User Installation Manual Polling over Speech If the customer reports abnormal amounts of redcare chirps on the te
3. Plug in installation alarm pin connections are made automatically when the 5G GSM STU is plugged in to the host alarm panel When fitting the STU check that the signals presented by the alarm panel match those required by the STU for the two sockets SK1 and SK2 The pins have been designated the following functions on the 5G GSM STU SK1_ Function SK2_ Fumetion Pini AlarmInputl Pin9 NotUsed i O Pin2 AlarmInput2 Pin 10_ SignalGround __ Pin3 Alarm Input3 Pin 11_ ATS Via STU LK3 Pin6 Control Output Pin 4 AlarmInput7 Low battery input Pin 16 Alarm Input 8 Via STU LK3 Note The alarm panel cannot make use of Pin 16 Alarm Input 8 as this is reserved for GSM Failure indication Note when the 5G GSM STU is plugged on to a suitable panel the power connections must still be made to the terminals marked 12V amp OV on TB1 For plug in installations be sure that no wires are ever connected to the terminals 1 to 8 on TB1 as this may result in damage to the alarm panel Terminals 9 10 11 T amp F can be connected if these channels are required in addition to those present on the plug in connectors SK1 amp SK2 Output relays Three output relays are provided Control Return Path Signalling RPS and Line Fault The use of any or all of these functions is optional For a basic installation these outputs are not required Note If an output is to be connected to a device whic
4. 7 As 1 but Line Fault output SK2 pin 15 and Comms Fail output SK1 pin 7 inverted Once the F2 value has been configured the MODE button returns to the main menu F3 Function 3 Telephone line connection type amp low tone levels Pressing set at the F3 menu option allows the Function 3 value to be configured At factory default the F3 digit is set to 0 The function 3 F3 specifies the type of telephone line to which the STU is connected either Public Switched Telephone Network PSTN or Private Wire PW and the attenuation to be applied to low tone The type of telephone line specified affects the method used by the STU to detect line faults and the attenuation level affects the amplitude of low tone output when the line is detected as being on or off hook Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Tip Connection type 0 will satisfy most PSTN installations but types 2 3 amp 4 can be useful to address some polling over speech POS faults caused by some phone type compatibility issues The Redcare helpdesk should be consulted for further advice Note PW Private Wire private Circuit connection This connection type is only available for specialised applications Once the F2 value has been configured the MODE button returns to the main menu F4 Function 4 Line monitoring Enable Pressing set at the F4 menu option allows the Function 4 value to be configur
5. U to register with the GSM network will result in the wireless path not commissioning Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Checking that the STU is commissioned When the 5G STU is correctly commissioned on the PSTN path the dot on the left hand display will flash every 5 seconds This denotes that commissioning over the PSTN path has been successful When the 5G GSM STU is correctly commissioned over the GSM path the dot on the right hand display will flash every 5 seconds This denotes that commissioning over the GSM path has been successful Additionally the dots will flutter each time a data poll is received over that path Downing the STU The Down STU command can be issued from the ARC For all 5G STU s this disables the port on the Redcare Scanner at the telephone exchange If the 5G GSM STU is contactable by the wireless path the STU will be fully de commissioned and caused to reset and reboot The 5G GSM STU s display will revert to NC Not Commissioned AC Fail F The input marked F on the STU is intended for AC fail This can be connected to the AC fail output on the alarm panel if required By default the STU has a 15 minute 5 minute delay on sending the pin 13 alarm when F is triggered Similarly there is a 15 min 5 min delay on the pin 13 restore The 15 min 5min delay can be removed by reconfiguring F8 menu to 0 No delay This is useful where th
6. ate 00 if no alarms are active or the numbers of the pins outstanding i e 4 pin 4 outstanding SS the GSM Signal Strength is as follows 0 31 or 99 undetermined NC Not Commissioned The STU has yet to receive an UP STU command from the ARC 5G STU configuration The 5G STU is factory supplied with the most common settings for most installations so generally the unit can be installed without the need to carry out configuration However if changes to the default setting are required they can be carried out as follows Note The 5G STU must be in the fully de commissioned state to enter the configuration menu To enter the configuration menu press and hold the MODE button for 5 seconds PP will be displayed on the display The MODE button can be used to step cycle through the main menu as follows PP Pin Polarity OC Message Select Open Close iD Set Hard ID number PE Pin Enable F1 Function digit 1 Control Relay F2 Function digit 2 Line Fault Polarity F3 Function digit 3 Connection Type F4 Function digit 4 Line Monitoring Enable F5 Function digit 5 Serial Parallel F6 Function digit 6 GSM Enable F7 Function digit 7 Line Fault Relay Operation BSIA LD Load Default Reset all variables to manufacturers default Commit to microprocessor memory The SET button is used to enter the sub menu for each function Tip Continually pressing the MODE button will always eventually retu
7. configured to MCD compatibility mode F4 3 This ensures that the STU s regular communication checks do not cause false triggering of the MCD BSIA form 175 mode 5G GSM STU This mode allows the alarm panel to determine whether a single or dual path failure has occurred on the GSM STU This is the default mode of the STU F7 3 Where an EN compliant panel supports this function connect the panels ATS output to the STU s ATS input pin 8 and connect the STU s LF relay to the line fault input on the panel Redcare 5G GSM STU Installation manual 04 07 2011 12 redcare 5G GSM STU User Installation Manual Alarm Panel 5G GSM STU CTRL LF RPS 42346567 91011T F 0 NOCNC INOCNC NOCHC ATS out Line Fail in Tellback in BSIA Form 175 wiring ensures panel detects Single Dual path failure To test the BSIA functionality e Disconnect the PSTN from the STU e The alarm panel display should show Comms Fail SINGLE within 1 minute e Then disconnect the GSM aerial e The alarm panel display should show Comms Fail ALL within 2 minutes e Reconnect the PSTN and Aerial to the STU and the comms fail message should clear from the panels display within 3 minutes When in BSIA mode F7 3 then triggering the ATS input to the STU pin 8 while both paths are registered as working OK will result in a pin 10 path test alarm being transmitted over GSM and a pin 11 path test alarm transmitted over PSTN
8. e alarm panel already has its own built in AC fail delay Note When the 15 minute timer is implemented triggering the F input will display AL F on the display immediately but the pin 13 alarm is only sent after the delay timeout Once the pin 13 alarm has been sent then restoring the pin F input will remain as showing AL F on the display until the 15min timeout has expired and the pin 13 restore has been sent and acknowledged re triggering F during the 15 min restore timer will simply result in the 15 min timer being cancled and restarted on the next F restore Tamper T The input marked T on the STU is intended for tamper This can be connected to a tamper output on the alarm panel if required The tamper alarm is signalled as pin 12 If agreed with the ARC the T input can be used as another general 12th alarm pin MCD compatibility When the STU is installed on a telephone line that shares other analogue data products e g Fax machine analogue modem or EPOS machine then it is recommended that a Redcare Modem Compatibility device MCD is used The MCD is a line powered plug in device that connects in line with the modem of fax machine The MCD ensures that the redcare signalling does not interfere with the modem and the modem signals do not interfere with the redcare signalling The MCD will cause the modem to be disconnected from the line if the STU has an alarm message to send Where an MCD is being used then the STU should be
9. e of the alarm inputs must be designated as an opening closing channel usually channel 4 The RPS output will activate when an opening or closing signal is detected It will de activate when the opening or closing signal has been acknowledged by the Alarm Receiving Centre It is allowable to have more than one input designated as an opening closing channel but each must be acknowledged to de activate the RPS output The RPS relay contacts Normally Open Common Normally Closed are available for connection on terminal block TB1 To use this option a warning device such as a piezo bleeper or external strobe light should be connected through these contacts The maximum current rating of the relay contacts is 1 Amp STU specifications Pin alarm inputs e Logic High 2 5V to 30V e Logic Low 0 5V to 0 8V Logic level outputs e Logic High 3 0V 560A max e Logic Low 0 4V 280pA max With respect to the OV terminal on TB1 Power Rating e 5G GSM 12Vdc 80mA mean 350mA peak Environmental e Operating ambient temperature 5 C to 40 C Relay contacts e 30V 1A Max Physical Size 168 x 115 x 36mm GSM aerial installation The Aerial supplied with the 5G GSM STU is designed for mounting on the top of an alarm panel Drill a suitable hole typically 11mm diameter in the top of the box in which the GSM STU is fitted Prevent swarf from entering the enclosure as it could cause internal short circuits Remove any burrs from the ho
10. ed At factory default the F4 digit is set to 1 0 Disable line monitoring 1 Enable line monitoring PSTN voltage and 20 minute forced poll on hook 2 Enable line monitoring PSTN earth calling mode 2 minute 20 sec forced poll on hook 3 Enable line monitoring PSTN voltage only Tip Type 1 will suit the majority of installations Default Type 2 is for Earth calling PSTN lines that may be associated with large older type PABX s Type 3 can be used where false disconnection of Redcare MCD is to be avoided after long duration gt 20min telephone calls Voltage Check LF if lt 4v Line medium VoltageHigh Off hook Fast 2 minute 20s communication check Slow 20 minute communications check Once the F2 value has been configured the MODE button returns to the main menu F5 Function 5 Pin serial data enable Pressing set at the F5 menu option allows the Function 5 value to be configured At factory default the F5 digit is set to 0 Tip The Serial alarm input is for future use and not to be used on 5G STU at this time All 5G STU s should use the O setting only Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual F6 Function 6 GSM enable 5G GSM STU only Pressing set at the F6 menu option allows the Function 6 value to be configured At factory default the F6 digit is set to 1 0 GSM path disabled GSM path enabled 2 F Reserved
11. ed the MODE button returns to the main menu iD hard ID number Pressing SET at the iD menu option enters the hard ID sub menu At factory default the unit has the last 4 digits of the serial number as its Hard ID Tip The 4 digit Hard ID forms part of the secure encryption key for signalling and there is generally no need to change this number The 4 digit number is Hexadecimal and can be in the range 0001 to FEFF Should a change be required the following procedure can be used When the Hard ID sub menu is entered the first 2 digits of the current Hard ID are displayed A lit Dot above the digit denotes the digit that will be changed with each press of the SET button The MODE button cycles to the next digit After setting the first 2 digits the last 2 digits are displayed again with a lit dot to denote the digit that will change with the SET button Once all 4 digits have been configured the MODE button returns to the main menu PE pin enable Pressing SET at the PE menu option enters the Pin Enable sub menu At factory default the all inputs are enabled Tip There is generally no requirement to disable inputs unused inputs can simply be left disconnected Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Should a change be required the following procedure can be used The input pins can be changed by using the MODE button to step through pins 1 to 11t amp F and using the SET but
12. for 2 seconds and then short out the Lrn pins until Pr is briefly displayed lt 6 secs e The inputs are now learnt with the required polarity ff mQ I S Ai i As g Security Position Learn Position Alternatively menu PP can be accessed to invert any inputs as required GSM STU pin 8 Pin 8 on the GSM STU is reserved for signalling low signal strength alarms A Signal strength which drops below 5 for a duration of 50secs will trigger a 3 mins timeout before a pin 8 alarm is activated and LF relay operates If the Signal strength is 5 or more for greater than 50secs during the final 3 min timeout then the timeout will be reset and pin 8 will not be activated After pin 8 is activated a signal strength of 5 or more for greater than 50 secs will restore pin 8 condition and LF relay Occassionally the display may show SS 99 This indicates that the GSM module can t determine the real value for Signal Strength eg because it s transmitting or busy If this indication persists for longer than 50 secs it will be treated as a Signal Strength less than 5 Upping the STU Once the STU is connected to the telephone line and powered up the STU must be upped from ARC Note on the GSM STU wait till the STU is registered with the wireless network before upping i e wait till the display shows SS gt 00 This generally takes about 45 seconds following power up Failure to wait for the ST
13. h produces transient voltages such as a bell the device should be suppressed using a suitable protection diode Control output relay CTRL This relay can be switched on or off by the alarm receiving centre ARC operator by sending and output ON or output OFF command to the STU through the redcare network The output can typically be used to remotely reset an alarm panel or to operate other devices such as lights or door latches at the site Line fault output LF The Line Fault Output is used to indicate at the protected premises that either or both the GSM and landline PSTN or Private Wire communication paths have failed The Line Fault relay contacts Normally Open Common Normally Closed are available for connection on TB1 The maximum current rating of the relay contacts is 1 Amp Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual For plug in installations Line Fault connections are made automatically when it is fitted in the host alarm panel The host panel must be programmed to accept this function At default the 5G GSM STU Line Fault output is set to comply with BSIA form 175 mode of working Other options are available as later described Return Path Signalling RPS The RPS output is used to indicate at the protected premises that the opening closing signal has been sent to and acknowledged by the Alarm Receiving Centre To use the RPS function at least on
14. le pass the RF cable through it and place the antenna in position It is advisable not to bond the antenna onto the box at this stage Wait until the system has been tested as it is difficult to remove once attached Try to route the RF cable away from any other wiring within the box to reduce the likelihood of interference Carefully connect the RF cable to the GSM module on the 5G GSM STU The connector is a micro miniature co axial MMCX screened type and is easily damaged Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Telephone line selection LK1 The 5G STU is supplied ready to connect to the Public Switched Telephone Network LK1 is not fitted If the 5G STU is to be connected to a Private Wire RedDIRECT a suitable link must be fitted in the position marked LK1 under the TNV cover For RedDIRECT PW working the 5G STU must be configured with F3 set to 1 Note the LK1 link provide 600 ohm line matching for PW working and is only generally used on legacy RedDIRECT circuits or for test purposes For normal PSTN connection LK1 is NOT required If you have any doubts about the type of telephone line to which the STU is being connected contact Redcare for advice 5G STU displays The current status of the STU is displayed on the 2 X 8 segment displays The STU will cycle through the messages in 1 second steps AL This is followed by the ALarm pins that are active in the Alarm st
15. lephone line during calls then in some instances reconfiguring the STU to F3 3 may help Alternatively contact the redcare helpdesk for further advice Panel permanently shows comms fail when a 5G GSM STU is used in plug on mode Asmall number of alarm panels may have the Comms Fail 7 or Line Fault 15 connections inverted on the plug on Molex pins Where this is the case use the alternative settings on the STU s F2 menu to correct this Support Redcare Helpdesk 0800 671 240 Glossary of terms 21CN 21st Century Network BT s upgrade of telephone exchange technology 3G STU 3rd Generation Subscribers Terminal Unit 5G STU 5th Generation Subscribers Terminal Unit AC Alternating Current ADSL Asymmetric Digital Subscribers Line ARC Alarm Receiving Centre BSIA British Security Industry Association UK Trade Association BT British Telecommunication PLC BT92A Block Terminal 92A Redcare specific connection point EPOS Electronic Point of Sale machine Credit card reader etc ESD Electro Static Discharge Form 175 BSIA document specifying dual path alarm signalling criteria GSM Global System for Mobile communications Groupe Sp cial Mobile LED Light Emmitting Diode MC Modem Compatibility Device Redcare specific MMCX Micro Minature Coaxial Connector NOCNC Normally Open Common Normally Closed Relay contact designations Polling Message interchange PSTN Public Switched Telephone Network PW Private Wire also Private Circui
16. nce a BT RedCARE Service Order must be submitted to BT RedCARE by the Alarm Receiving Centre This ensures that the appropriate exchange connections have been made and a BT RedCARE block terminal 92A where required has been provided at the customer s premises It is strongly recommended that a site survey is carried out to check for suitable GSM signal strength at the proposed GSM STU location The 5G GSM STU uses SMS messaging across the 02 GSM mobile phone network and for reliable operation a signal strength of 12 or greater 90dB should be available at the location of STU installation Safety statement The circuit board area under the cover is classed as a Telecommunication Network Voltage TNV 3 circuit All other interconnection points are classed as Safety Extra Low Voltage SELV circuits It is only necessary for this cover to be removed during installation of the PSTN wiring A protective earth connection is required to the terminal block TB5 The 5G STU is designed for host independent fitment The host alarm panel or box into which the 5G GSM STU is installed must provide a RESTRICTED ACCESS LOCATION in accordance with the requirements of BS EN 60950 Suitable user protection to ensure compliance with BS EN 60950 should be present on the host or its fitted equipment A hazardous voltage is one which exceeds 42 4V peak AC or 60V DC If you have any doubt seek advice from a competent engineer before installing this or other ada
17. pters into the host equipment Static sensitive devices Static electricity is present in our everyday lives A static charge is generated by friction and whenever two dissimilar materials are separated The imbalance of electrons causes a potential difference of many hundreds of volts On discharge a large current flows for a short time Many electronic components can be damaged by such static charges Component failure may not be immediate or catastrophic Electro Static Discharge ESD can cause hidden damage to components which will affect their reliability It is recommended that precautions are taken against damage due to static electricity during the installation and maintenance of the 5G GSM STU Suitable ESD protection measures include ensuring that you are earthed via a wrist strap and a 1M resistor whenever you handle the unit 5G GSM STU siting When surveying the site please remember that the GSM STU operates in a similar way to an ordinary mobile telephone therefore any restrictions on the use of mobile telephones in the area will also apply to the GSM STU Premises such as hospitals petrol stations airports blasting areas etc may operate a mobile telephone restriction in certain areas Always ensure that the chosen site is free of any mobile telephone restrictions and advise the end user so that they are aware should any restrictions come into force in the future Note It is recommended to perform a signal strength
18. redcare 5G GSM STU User Installation Manual This manual contains information on the Redcare 5G GSM STU It contains more detailed information than that provided in the Quick start user guide provided with the GSM STU The following products are covered e Redcare 5G GSM STU GSM Antenna GSM Engine TNV Cover MMCX Connector PL2 Debug Point PL1 Serial Port PL3 Sec Ln LK1 Private Wire Link LK3 Alarm 8 Panel Link Set Key 8 Segment Underside Plug In Main Terminal Block TB1 LED s Connectors Fig 1 5G GSM STU Description The 5th Generation Subscribers Terminal Unit 5G STU is a communicator for signalling alarm signals between a protected premises and an Alarm receiving centre ARC The 5G STU uses the extremely reliable BT redcare network to convey the messages over a Redcare enabled BT analogue PSTN line A secondary communications path is provided using SMS signalling over the GSM network Even if an intruder cuts the line and jams the radio signals an alarm message will still rapidly be sent to the ARC The 5G GSM STU is fully compatible with BT s 21CN network upgrade program and connects to any BT redcare enabled telephone line The 5G STU is fully ADSL compliant and does not require an additional ADSL microfilter BTE Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Pre installation requirements Before a 5G STU installation can comme
19. rn to the main menu and to the exit point Tip The main menu can only be exited at the LD or prompts see these sections for exiting configuration mode Tip If the state of configuration is unknown then it can be reset to the factory default settings from the LD load default menu option Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual PP pin polarity Pressing SET at the PP menu option enters the pin polarity sub menu At factory default all inputs are set to positive applied triggering The input pin polarity can be changed by using the MODE button to step through pins 1 to 11 t amp F and using the SET button to toggle the input polarity for that pin The following display symbols are used to denote positive applied or positive removed triggering V Pos Pos Applied Removed Once all pins have been configured the MODE button returns to the main menu OC Open Close message select Pressing set at the OC menu option enters the OPEN CLOSE sub menu At factory default all inputs are set to send ALARM RESET messages except pin 4 that is set to send OPEN CLOSE messages The message type for each pin can be changed by using the MODE button to step through pins 1 to 11 and using the SET button to toggle the message type for that pin The following display symbols are used to denote the pin message type O Open Close A Alarm reset Once all pins have been configur
20. t a point to point communications line REN Ringer Equivalence Number RF Radio Frequency SELV Safety Extra Low Voltage STU Subscribers Terminal Unit A Redcare Alarm communicator TNV Telephone Network Voltage UP STU The process of bringing a STU into service Commissioning BT Offices worldwide The services described in this publication are subject to availability and may be modified from time to time Services and equipment are provided subject to British Telecommunications plc s respective standard conditions of contract Nothing in this publication forms any part of any contract British Telecommunications plc 2011 Registered office 81 Newgate Street London EC1A 7AJ Registered in England No 1800000 PHME 62558 Designed by Howell Wong Costello Redcare 5G GSM STU Installation manual 04 07 2011
21. t be connected to a suitable power supply The installer must ensure that the rating of the power supply is greater than the combined rating of the 5G STU and any other apparatus drawing power from the power supply The 5G GSM STU supply requirements are detailed on page 5 Note when the 5G GSM STU is plugged on to a suitable panel the power connections must still be made to the terminals marked 12V amp OV on TB1 REN The Ringer Equivalence Number REN for the 5G STU is 1 0 As a guide to the number of apparatus that can be simultaneously connected to a line the sum of REN values for each apparatus should not exceed 4 0 A BT provided telephone is assumed to have a REN value of 1 0 unless otherwise marked If the 5G STU is used with an MCD the combined REN will be 11 2 Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Training courses Redcare offer a free training course for installers of the Redcare service For further information call General Enquiries Tel 0800 800 828 5G GSM STU inputs The STU has 11 screw terminal inputs plus tamper T amp AC fail F for connection to the monitored equipment such as an alarm panel 3 inputs on the Fire STU Note on GSM STU pin 8 is reserved for low signal strength and pin 10 amp 11 maybe reserved for path test alarms in BSIA mode F7 3 The alarm inputs are triggered by changing their voltage state 5G GSM STU plug in option For
22. test during a pre installation site visit Redcare 5G GSM STU Installation manual 04 07 2011 redcare 5G GSM STU User Installation Manual Determine where the GSM STU enclosure will be eventually situated Place an 02 mobile phone or GSM STU at the location it is to be installed switch it on and observe the signal strength For reliable operation a signal strength of 12 or greater 90dB should be available at the location of STU installation If the signal strength is weak try to find a better position for the 5G GSM STU unit If required a higher gain extension antenna with an extension cable is available at extra cost from BT Redcare Part No 47536 https www btinstallershop com home aspx Telephone line connections Connect the 5G GSM STU to the BT RedCARE block terminal Only one 5G STU may be connected to any one telephone line WARNING the block terminal contains telecommunication network voltages Please note that it is important to use the correct method of connecting the STU to the BT Block Terminal 92A The Block Terminal provides an insulation displacement connection IDC block for the incoming phone line No connections other than those made by BT should be made to this IDC block The STU should be connected to the screw terminals as shown The 5G GSM STU is not polarity conscious on its line terminals STU wiring BT wiring Fig 2 BT Redcare Block Terminal 92A Power supply The 5G GSM STU mus
23. ton to toggle the input to Enabled or Disabled for that pin The following display symbols are used to denote pin enabled or disabled is enabled _is disabled Once all pins have been configured the MODE button returns to the main menu F1 Function 1 Control Output Relay Pressing set at the F1 menu option allows the Function 1 value to be configured At factory default the F1 digit is set to 0 The function 1 F1 value has the following functionality 0 Control output relay NOT energised at power up 1 Control output relay energised at power up Once the F1 value has been configured the MODE button returns to the main menu F2 Function 2 Line Fault relay Presing set at the F2 menu option allows the Function 2 value to be configured At factory default the F2 digit is set to 1 The function 2 F2 value has the following functionality 5G Classic STU 0 Line Fault relay de energised when landline path has failed 1 Line Fault relay energised when landline path has failed 5G GSM STU O Line Fault relay de energised when both landline and GSM paths have failed 1 Line Fault relay energised when both landline and GSM paths have failed 2 As O but Line Fault output SK2 pin 15 inverted 3 As 1 but Line Fault output SK2 pin 15 inverted 4 As 0 but Comms Fail output SK1 pin 7 inverted 5 As 1 but Comms Fail output SK1 pin 7 inverted 6 As O but Line Fault output SK2 pin 15 and Comms Fail output SK1 pin 7 inverted

Download Pdf Manuals

image

Related Search

Related Contents

EW3595 Auriculares Bluetooth con radio FM y ranura para tarjeta  自動火災報知設備の点検に先立って、他の設備  USB930HxADBD Adapter Board User's Manual  Page 1 Page 2 は じめに 弊社 株式会社テクニカルプラニングは平成2年  取扱説明書 - ソニー製品情報  CB24 28 Installation and Servicing Instructions  Sondar 2000 Ultrasonic Level Meter Manual  FUJ"RY6Kー    Anleitungen - Billiger.de  